Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹42.0 L+₹79,913.90 (1.94%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹44.2 L+₹3.0 L (7.16%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance Quoting Higher Rate | |
| 4 | L4₹45.3 L+₹4.1 L (9.88%)Rejected-Finance | L4 | Rejected-Finance Quoting Higher Rate | |
| 5 | Rejected-Technical | - | Rejected-Technical Insufficient Documents follow tech2 |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
15 Jan 2020, 3:00 pmClosed
Superintending Enginee
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
EI works of Main building of Deshbandhu Mahavidyalaya, Chittaranjan. - E I Work incl fittings and fixtures and installation of Lightning Arrester.
2019_WBPWD_262936_1
WBPWD/SEWEC /AED /NIQ-48/2019-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Asansol
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.0 L
Office of the Superintending Engineer, Western Ele
29 Jun 2020
30 Dec 2019
17 Jan 2020
30 Dec 2019
15 Jan 2020
3 Jan 2020
30 Dec 2019 - 2 Jan 2020
2 Jan 2020
Amount
SUB-HEAD 1--DISTRIBUTION WIRING Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling and horizontal run portion] and in19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall] to light / Fan / Call bell point with piano key type switch on sheet metal switch board with bakelite top cover flushed in wall as per GS with following average run.
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in suitable size PVC casing capping (Precision make) [for ceiling, horizontal & vertical run portion] on wall to light / Fan / Call bell point with piano key type switch on sheet metal switch board with bakelite top cover on wall/surface as per GS with following average run.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC)and in19mm bore, 3mm thick polythene pipe embedded in wall to light / Fan / Call bell point with piano key type switch on sheet metal switch board with bakelite top cover flushed in wall as per GS with following average run.(Board concelled)
8 Mtr [ 1 (iii) / E- 20 ]
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19 mm bore, 3mm thick polythene pipe [for vertical run embedded in wall],to light/fan/call bell points with Modular type switch as per GS with following average run.
8 Mtr. [ 5 (c) / E- 25 ]
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 20 mm dia pvc rigid conduit on wall to 240 V 6A 5 pin plug point with sheet metal switch board incl bakelite top cover 3 mm thick flushed in wall as per GS.
On Board
Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS.
On Board [ 3 (i) / E- 20 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in 20/25 mm dia PVC rigid conduit on wall (for Hoz. Run only) and 19 mm dia 3 mm thick polythene pipe embedded in wall (in drop conceal manner) in wall as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2 x (2.5 sqmm)+1x(1.5 sqmm) [1(s) /E- 9]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ]
4x(10 sqmm)+2x(6 sqmm) in 2 X 25 mm dia polythene pipe ( Horizontal & Vertical run concealed manner) [ 1(b1) /E- 9 ]
4x(16 sqmm)+2x(10 sqmm) --- Do --- [ 1(b1) /E- 9 ]
4x(25 sqmm)+2x(10 sqmm) --- Do --- [ 1(b1) /E- 9 ]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS
Supplying & Fixing sheet metal switch board (16 SWG) of the following sizes (in mm ) flushed in wall with Ph, N & E copper connector bars / terminals as per GS
SUB-HEAD 2--BDB,PDB,VTPN ETC Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+8 Way [Simens / Legrand / Crabtree ] [ 13 / D- 9 ]
2+12 Way [Simens / Legrand / Crabtree ] [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - [Simens / Legrand / Crabtree ] )
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS( Make - Legrand/Siemens/Cabtree) )
8 Way ( Up to 160 A ) [15 / D- 11 ]
6 Way ( Up to 160 A ) [15 / D- 11 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand / Siemens/Cabtree ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -[Simens / Legrand / Crabtree ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make -[Simens / Legrand / Crabtree ] .
SUB-HEAD 3-- SUPPLY & LAYING OF CABLES Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make : Polycab/KEI/Havells]
2 Core 6 Sq. mm [ NS ]
4 Core 16 Sq. mm [ NS ]
4 Core 25 Sq. mm [ NS ]
4Core 50 Sq. mm [ NS ]
2 Core 10 Sq. mm
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm with 1X 10 SWG G I wire [ 5(i)/ F- 3 ]
Laying of cable on wall / surface incl S/F MS shaddle with earthing attachments as per GS for the following Sizes.
up to 25 Sq. mm with 2X 10 SWG G I wire [ 5(ii)/ F- 3 ]
Laying of cable on wall / surface incl S/F MS shaddle with earthing attachments as per GS for the following Sizes.
35 to 50 Sq. mm with 1X 10 SWG G I wire [ 5(ii)/ F- 3 ]
Laying of cable upto 35 Sq mm in underground trench as per GS for the following numbers of Cables.
1 No Cable [1(b)/F-2 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
2 Core 6 Sq. mm [7(a)/F4 & 8(b) /F5]
2 Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
4Core 16 Sq. mm [7(c)/F4 & 8(b) /F5]
4Core 25 Sq. mm [7(c)/F4 & 8(b) /F5]
4Core 50 Sq. mm [7(d)/F4 & 8(b) /F5]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
40mm dia [11(d)/F-6]
SUB-HEAD 4-- PLUGS & SOCKETS Supply & Fixing 240 V, 6A plug socket with 6 A Piano key type switch on existing sheet metal switch board after cutting the bakelite top cover incl connection of wires as per GS
Supply & Fixing 240 V, 20A plug socket with 20 A Piano key type switch on existing sheet metal switch board after cutting the bakelite top cover incl connection of wires as per GS
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top as per GS.
Supplying & Fixing Industrial Plug & Socket board with 415 V, 32A, TPN & Earth Metal Industrial Plug socket & 32A Industrial top as per GS
Supply & Fixing 240 V, 3 nos. 6A & 1 no 20A plug socket with separate 3 nos. 6 A & 1 nos. 20 A Piano key type switchon 12 module G I modular type switch board with module top cover plate flushed in wall incl connection as per GS as per GS
Supply & Fixing 240 V, 2X6 A, 3 pin Modular type plug socket with 2X6A Modular type switch on 6 module G I modular type switch board with module top cover plate flushed in wall incl connection as per GS
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switchon 4 module G I modular type switch board with module top cover plate flushed in wall incl connection as per GS
SUB-HEAD 5 -FIXING OF LIGHT FITTINGS Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
Fixing only single/twin fluorescent light fitting on the wall by means of suitable fastner and “L” type MS clamp as per GS
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS
SUB-HEAD 6 - SUPPLY OF LIGHT FITTINGS Supply of 4 Ft. 18/20 Watt single/twin LED Tubelight fitting with PC body for indoor application complete with all accessories & Lamps having following Model / Cat No.( Make -Philips/Crompton/Wipro/Bajaj as per choice of EIC)
a. 1*TLD 18/20W LED fittings ( TMC 501 ) with 1X 18/20 watt P C Body LED tube light 2100 lumen (Similar of Crompton/Bajaj/Wipro)
b. 2*TLD 18/20W LED fittings ( TMC 501 ) with 2X 18/20 watt P C Body LED tube light 2100 lumen (Similar of Crompton/Bajaj/Wipro)
Supplying & Fixing of LED bulb (10 Watt) (MAKE- Philips/Crompton/Wipro/Bajaj )
Supplying & Fixing of LED Surface/ Recess mounted Fittings (18/20 Watt) MAKE- (Philips/ Jaquar/Wipro) Model Sleek Surface /Nero Surface square) (As per Choice of EIC)
Supplying & Fixing of LED Surface/ Recess mounted Fittings (33 Watt) MAKE- (Philips/ Jaquar/Wipro) (Model-full Glow /Sauver)
Supplying & Fixing of LED compound Light Fittings (90 Watt) MAKE- Philips - BRP 410 LED 92 CW / Crompton/Wipro/Bajaj
SUB-HEAD 7 -- FIXING OF FANS Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board after making housing as per GS
Supply & Fixing Modular Socket(2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing modular Gl switch board with top cover plate as per GS
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS
Extra for supplying additional wire for down rod & painting the rod as per GS
Drilling hole on fan motor and downrod incl. S&F split pin as per GS
Engraving the deptt. number with 10 mm lettering on the body as per GS
Extra for additional one letter incl. hifen, stroke and stop as per GS
Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS
Extra painting for additional one letter of the engraved number as per GS
Fixing only exhaust fan after making holes in wall as per GS
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers as per GS
SUB-HEAD 8 -- SUPPLY OF FANS Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -Crompton / USHA )As per choice of EIC
a. 1200 mm Sweep ( Aura Metallic / Usha STRIKER)
b. 1400 mm Sweep ( Aura Metallic / Usha STRIKER) )
Supplying of Exhaust Fan
Supplying of wall bracket fan (18") with metal blade /back cover. Make : Crompton/Orient / USHA ) As per choice of EIC
Supply and fixing 2 way modular type switch board with cover plate and 1 No 6 A 5 pin plug socket flushed in wall and mending good the damages.
Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) on HW board as per GS
S & F 240V 21A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG suitable size Box in wall with top cover plate incl. necy. Conncetion as per direction of EIC for AC Machines . (Ultratech /Wipro - electron ) as per choice of EIC
Supply & fixing 2 way MCB sheet metal enclosure box with 1 No. DP 32A MCB flushed in wall including connection of wires..(make : Legrand /Siemens/ Crabtree)
Supply & fixing 4 way MCB sheet metal enclosure box with 1 No. FP 63A MCB flushed in wall including connection of wires..(make : Legrand /Siemens/ Crabtree)
Supply & fixing 4 way MCB sheet metal enclosure box with 1 No. FP 40A MCB flushed in wall including connection of wires.(make : Legrand /Siemens/ Crabtree)
Supply & fixing sheet metal (16 SWG) cable terminal box with 1 no 4 awy bakelite base terminal block 100A capacity flushed in wall including connection & mending good damages
Supply & fixing double door sheet steel (16 SWG) powder coated MCBDB cable end terminal box
8 way VTPN
6 way VTPN
6 way PBDB
4 way PBDB
SUB-HEAD 10 -- SITC OF LT PANEL SITC of of floor cum wall mounted (On a base frame ) totally enclosed, cubical type electrical control panel specification of which will be as below and as per drawing approved by EIC
The general construction of the pannel will conform to IS 8623:93 as ammended uptodate. The Degree of IP protection for the enclosure will be IP-42.
The enclosure will be fabricated out of 16SWG thick CRCA sheet, angle iron of size - 40X40X6
It will be compartmentalised type having seperate space and arrangement for busbars & cable alley,
The incoming and outgoing switches will be connected with the 99.99 % pure tinned copper 43 V 415 A (4 x 50 x 5 mm) busbar with suitable colour (R, Y, B and Black ) PVC cover
2 Nos 20 X 3 ( 20X 5 mm for >400A) copper strip shall be fixed all around the panel and will be connected to 2 nos copper earth bus bar connected to incoming earth conductor
It will be powder coated after seven tank pretreatment process and the paint thickness will be 60 micron.All tests should be made for the complete panel.The following switches & accessories will be fixed in the panel (The panel should be manufacture from CPRI approved manufacturaaers and before panel fabrication an auto cade drawing must be approved from EIC
INCOMING SWITCHES
S&F 415V, TPN SFU ( Open Execution Type ) including HRC Fuses of following Capacity [ Make - Simens/LT/ABB ]
BUSBAR
The Busbar will be made by electrolytic copper bars of 415A (4 x 50 x 5 mm)
OUTGOING SWITCHES
S&F of 415V, TPN SFU ( Open Execution Type ) including HRC Fuses / 4Pole ACB / of following Capacities [ Make Simens/LT/ABB]
a 125 A , 2 Nos
b 100 A , 2 Nos
c. 63A , 3 Nos
CHANGE OVER SWITCH
S&F 415 V, open execution type 4P, on-load changeover switch of following capacity and Cat No. [ Simens/LT/ABB Make ]
a,125 A ,1 Nos
ACCESSORIES
S & Fixing Following Accessories --
Digital Ammeter ( 0-250A ) [ Make - L & T Vega Series ] - 1 No /Siemens/ABB
Current Transformer ( 250A - 5A ) [ Make - KAPPA/AE ]-3Nos
Digital Voltmeter ( 0 - 500 V ) [ Make - L& T vega Series ]-1 No
Led Indicating lamp ( R,Y, B ) - 1 Set
Slide lock fuse 3 Sets
SUB-HEAD 10 -- EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS
For Morum Soil [1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Earthing with 65 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm as per GS
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
10SWG [5(a)(iv)/G-2]
4SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall as per GS
Supply & erection of 80mm dia 2 mtr. Long Minipole (TATA M) with 150 mmx150 mmx6 mm base plate & cap etc. in CC foundation (Proportion and dimension indicated below), Compound light Arrangement having with hard jhama metal including CC (6:3:1) muffing 400mm dia and 750mm height above roof including 3 mm thick neat cemented finish with supply fixing only 200mm x 150mm x 100mm GI loop box incl loop wire by 2 X 1.5 sqmm PVC cu wire through 19 mm dia polythene pipe and GI earth bolt after making drilled holes etc.
S & F 1.5 Mtrs. Long 40mm dia G.I detachable pole top arm bracket with sleeves, nuts etc as required with painting by one cote red led and one cote of synthetic enamel paint . i)single arm
Supply & fixing 200X150X100 mm sheet metal outdoor type loop box with 1 no. 15A fuse base & bridge & 1 no bakelite base 2/3 way terminal bar flushed in wall for proper distribution of compound light cable
Supply & fixing of 230V MF1 Srarter on flat iron frame on wall including connection. (Make : L&T/Simence/ABB)
Installation of lightning Conductor S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
S&F of 4 SWG GI(Hot DIP)wire on parapet /Roof/ plinth/surface of wall for lighting conductor as required (horizontal Run) wuith 40mm long GI staples spaced not exceeding 1300 mm apart incl. mending good all the damages to the building works.
S&F of 4 SWG GI(Hot DIP)wire on parapet /Roof/ plinth/surface of wall for lighting conductor as required (Vertical Run) wuith 40mm long GI staples spaced not exceeding 1000 mm apart incl. mending good all the damages to the building works(excluding hair charges of scaffolding).
Making soldered joints between conductors, conductors and air terminals by suitable size GI wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint as to GS
Making soldered joints between conductors and down pipes/ other metallic objects by suitable size GI wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint as to GS
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Earthing the installation by 2" dia G.I pipe in morrum soil as per G.S Make TATA M incl. Excavation of soil for installation of Earth Electrode and filling & ramming (morrum soil)
Extra for treatment of soil by using salt & charcoal or coke for electrode
S/Laying 1.1 kv grade multistrained 1x10 sq.mm PVC insulated copper conductor (Polycab/Havells/KEI) on wall with 20mm PVC rigid conduit from earth pit to earth bar with both side copper socketing as per direction of EIC
Extra for providing masonery Work on the top of the roof of overall size 1000 x 300 x 300 mm complete with cemented brick work(1:4) duly plastered with cement morter for Fixing LA conductor.also providing Anchoring arrangement for fixing insulator and LA conductor.
Testing the whole earthing system of LC, dedicated earth and building earth by earth spike and megger and the report must be submited to the EIC
PARTHA SARKAR
RASH ELECTRICAL WORKS
SHANKAR BHATTACHARJEE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .