| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹29.5 L+₹5.0 L (20.6%)Rejected-AOC BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L2 | Rejected-AOC other than lowest tenderer | |
| 3 | L3₹34.1 L+₹9.7 L (39.5%)Rejected-AOC MOH SWAMI PADAM JAHANGIRPUR GREATER NOIDA GAUTAM BUDH NAGAR UP 203141 | GREATER NOIDA | GAUTAM BUDH NAGAR | UTTAR PRADESH | 203141 | L3 | Rejected-AOC other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹88,420
Closing Date
9 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Tughlakabad
HQ CWE(AF) Tughlakabad
REPAIR MAINT OF AC PLANTS AT 3 BRD, UNDER GE (AF) MC CHANDIGARH
2021_MES_460046_1
CA NO. CWE/TKD/CHD/TOKEN-23/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) MC CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) MC CHANDIGARH
₹88,420
Yes
9 Sept 2021
15 Jul 2021
11 Aug 2021
15 Jul 2021
9 Aug 2021
28 Jul 2021
60 days
Amount
M&L for opening of condenser cover of both sides including disconnecting of water pipe line for inlet and outlet of the condenser of each plant. Removing scale/sludge precipitated in the copper tube by push and pull method with iron rod connected with steel wire brush of suitable size as per condenser copper tube size at the entire length of condenser and scraping down the sludge precipitated inside the tube. Closing both side of condenser and circulating the descaling solution in all tubes of all three condenser of each plant through the circulating pump and allow to hold it for 30 minutes for chemical reaction, opening the condenser from both sides and clean with iron rod connected with nylon brush of suitable size as per condenser copper tube size at the entire length of condenser ensure that descaling process has been complete then closing the condenser at both end and circulating clean water in all the tubes of condenser of each plant and drain out process to continue till the satisfaction of Engr-in-Charge, then fixing new gasket for both ends of the condensers of each plant tighten with new nut end bolt for the following AC plants
3x20 TR Central type (Plant No 2)
3x70 TR Central type (Plant No 3)
3x35 TR Central type (Plant No 08)
3x50 TR Central type (Plant No 09)
3x60TR Central type (Plant No 13
3x100 TR Central type (Plant No 26)
3x16TR Central type (Plant No 32)
M&L for removing of alpha filter from its position and layout at site for refixing after cleaning, AHU cooling coil using chemical with brass brush in-order to remove all type of sludge/dust precipitated on the coil without any damage to the copper cooling coil then wash the cooling coil with fresh water and air blower to the entire satisfaction of Engr-in-Charge. Cooling coil drain water shall be clean, if any type obstacle is there in the flow of water, iron body of the AHU inside and outside shall be scrapped down and rubbed out with sand paper then apply one coat primer over a coat of synthetic enamel paint including part of duct portion in the AHU shall be completed upto the satisfactory of Engr-in-Charge for the AHU of following AC plant complete all as specified and and directed.(Plant No. 2, Plant No 3,Plant No 8, Plant No 9, Plant No 13, plant No No 26,Plant No32.)
M&L for cleaning with CTC greasing with multi grade ball bearing grease of approved make i.e wax pole astral for AC plant compressor motor (60 HP-03 Nos,25HP-3,75HP-03Nos) mono block pumping set (7.5 HP-03 Nos), water chiller motor( 8.75 HP- 02 Nos,12.5 HP-05 Nos,7.5HP-03Nos,15HP-03Nos,5HP-03Nos) cooling tower motor (7.5HP -01 Nos, 12.5HP-01Nos) blower motor 5.5 HP-01 Nos and blower shaft with two pairs of bearing -03 Nos complete all as specified and directed.
M&L for pressure testing for entire system of condenser, compressor and circulating system with CO2/Nitrogen gas and retain to allow the pressure for three days, if any leakage in found or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage permanently for the following AC plants complete all as specified and directed. AC plant.(Plant No. 2 (3x20TR), Plant No. 3 (3X70TR),Plant No. 8 (3X35TR), Plant No. 9 (3X50TRTR), Plant No. 13 (3X60TR), Plant No- 26 (3x100TR), Plant No-32 (3X16TR).
M&L for checking the leakage by vacuum plant for 24 hrs in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leaks by providing of Teflon tape, sealing of all refrigerant line valves like liquid lines valves/suction/ discharge valves of compressors, gland packing of all angle valves flaring of the following AC plants complete all as specified and directed.(Plant No. 02, Plant No. 03,Plant No. 08, Plant No. 09, Plant No. 13,Plant No.17, Plant No. 18, Plant No. 19,Plant No. 20,Plant No. 21,Plant No. 22,Plant No. 23,Plant No. 24,Plant No. 25 & Plant No32,)
M&L for cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities such as silt, dust particles mud/ sand inside the dome and around the fins, on wiremesh, main shaft etc and other connected items complete all as specified and directed for the following AC plants. (i) Plant No-2(3x20TR)-Delta cooling tower 50 TR Capacity (ii) Plant No-3(3x70TR)-Delta cooling tower 160 TR Capacity (iii) Plant No-8(3x35TR)-Delta cooling tower 70 TR Capacity (iv) Plant No-9(3x50TR)-Delta cooling tower 120 TR Capacity (v) Plant No-13(3x60TR)-Delta cooling tower 125 TR Capacity (vi) Plant No-26(3x100TR)-Delta cooling tower 250TR Capacity (vii) Plant No-32(3x16TR)-Delta cooling tower 40TR Capacity
M&L for complete service of air cooled package units by washing and cleaning of condensing units and indoor cooling coil with hydrochloric acid with jet pump, brushing the tubes and wherever required without damaging the tubes , oil fan motor and blower motor , replacement of gaskets and unserviceable nuts & bolts assembling back including testing complete all as specified and directed for the following plants. {Plant No. 17 (3x5.57TR), Plant No-18 (2x8.75TR),Plant No. 19 (3X8.75TR), Plant No. 20 (2X8.75TR), Plant No 21 (3x5.5TR), Plant No. 22 (3x11TR),Plant No. 23 (3X11TR), Plant No.24 (3x11TR),Plant No. 25 (3x11TR)}.
M&L for checking the leakage of air cooled package type unit of capacity 5.5 TR to 11.0 TR in both low and high side of the system by feeding dry nitrogen to maintain adequate pressure in the system, restoring the leaks including S&F replacement of teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete all as spceified and as directed.
M&L for vacuum the system and after maintaining vacuum for 24 hours supply and charging refrigerant gas R-22 complete all as specified and directed.
M&L for vacuum the system and after maintaining vacuum for 24 hours supply and charging refrigerant gas 134a complete all as specified and directed.
M&L for vacuum the system and after maintaining vacuum for 24 hours supply and charging refrigerant gas R-407 complete all as specified and directed.
Supply and filling in replacement of compressor oil non freezing type N-68 complete all as specified and directed.Make : Servo/Sheetal/Caltex
Calibration and repair to the Micro processor for chiller base reciprocating type compressor Make Voltas of capacity 11 to 18 TR including repair to MPD and VPD, and 3 phase 415 volts electric supply complete to its full load capacity complete all as specified and directed.
All as per item No-13 but Voltas, Capacity 5.5 to 8.5 TR package type complete all as specified and directed.
M&L for dismantling and replacement of unserviceable indoor blower motors of VRF system (MLH Annexe Bldg) Name of manufacturer : LG Year of installation : Jan-2018 Capacity : 293 HP complete all as specified and directed.
M&L for dismantling and replacement of unserviceable Outdoor Fan motors VRF system (MLH Annexe Bldg) Name of manufacturer : LG Year of installation : Jan-2018 Capacity : 293 HP complete all as specified and directed.
M&L for calibration and repair to the Micro processor for chiller base reciprocating type compressor Make;- LG capacity .75 TR to 2.5 tr including repair to MPD and VPD, and 3 phase 415 volts electric supply complete to its full load capacity complete all as specified and directed .
M&L for repairing and servicing of mono block pump 7.5 HP capacity of any make and size including replacing the defective parts complete all as specified and directed.
S&F in replacement of power contactor rated 40 Amp current AC1, 4 pole 415 volt with AC coil having pole contact composition for 4 NO (2NC+2NO) complete all as specified and directed. Make :- Cat part No C104004/C104008 of Indo Asian or equivalent in Siemens/L&T.
S&F in replacement of power contactor rated current 60 Amp 4 pole, 415 volt with AC coil having pole contact composition for 4 NO (2NC+2NO), complete all as specified and directed by Engr-in-Charge. Make :- Cat part No C106004/C106008 of Indo Asian or equivalent in Siemens/L&T.
S&F in replacement of power contactor 3 pole type MNX, 70 Amp 240 volt, 50 Hz / 288 volt, 60 Hz with AC coil complete all as specified and directed. Make :- L&T Cat part No CS97076 or equivalent in Siemens/L&T
S&F in replacement electronic timer on delay front mounted 0.1s to 30s (1NO+1NC), complete all as specified and directed. Make :- Cat part No IACF5-T2 of Indo Asian or equivalent in Siemens/L&T.
S&F in replacement of power contactor 32 Amp 3 pole, type ML-2, 415V complete with auxiliary contacts 2NO+ 2NC complete all as specified and directed. Make :- L&T cat No SS90701/ Havells/BCH
S&F in replacement of power contactor 40 Amp 3 pole, type ML-3, 415V complete with auxiliary contacts 2NO+ 2NC complete all as specified and directed. Make :- L&T cat No SS90721/ Havells/BCH/
S&F in replacement of power contactor 70 Amp 3 pole, type ML-4, 415V complete with auxiliary contacts 2NO+ 2NC complete all as specified and directed. Make :- L&T cat No SS90921/ Havells/BCH
S&F in replacement of power contactor 18 Amp type MNX-18, 415 V AC 3, with auxiliary contacts 1 NO + 1 NC, complete all as specified and directed. Make :- L&T Cat part No CS94100/CS94101 or equivalent in Siemens/L&T
S&F in replacement of power contactor 25 Amp type MNX-25, 415 V AC 3, with auxiliary contacts 1 NO + 1 NC, complete all as specified and directed. Make :- L&T Cat part No CS94110 or equivalent in Siemens/L&T
S&F in replacement of power contactor 95 Amp type MNX-95, 415 V AC 3, with auxiliary contacts 2 NO + 2 NC, complete all as specified and directed. Make :- L&T Cat part No CS94136 or equivalent in Siemens/L&T
M&L for digital type electronic temperature meter sensing the temperature from in side the user room and display on outside the AHU including wiring for sensing cable in casing and capping complete all as specified and directed.
M&L in replacement of motor bearing suitable for 75 HP compressor motor complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 60x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip of size 32x6 mm by means of bolts, nuts check, nuts and washers including charcoal dust common salt necessary excavation in soft loose soil returning filling in and removal of surplus soil to a distance up to 50 M, PCC pit in cement concrete 1:3:6 type C1 using (20mm grade stone aggregate), precast RCC cover shall be provided in RCC 1:2:4 type B-1 (using 20mm grade stone aggregate) 40mm thick pit cover reinforced with 8mm dia TMT bars 75mm c/c both ways, MS handle 12mm dia, PGI funnel wire mesh and GI watering pipe of 20mm bore (light grade) and earth lead protection pipe 40mm bore (light grade) GI pipe for earth lead protection, including earth work complete all as per Electrical Plate No 3 of SSR Part-I,2009 complete all as specified and directed.
M&L for earth continuity conductor or copper main earthing lead fixed to wall or bottom on porcelain insulator or recess on chases or buried in ground or drawn in conduit/pipe size 32x6 mm strip complete all as specified and directed.
S&F porcelain insulator on angle iron frame for mounting of strip heater all as required, complete all as specified and directed.
Dismantling and taking down old, unservicable, unblanced fan blade with unservicable broken sprinkler for replaced from top of cooling tower of following AC plant No-02 Delta cooling tower 50 TR Capacity & plant NO-08 Delta cooling tower 70 TR Capacity complete all as specified and directed.
Supply and fixing sprinkler of size 5'' dia on top of fan assembly for erection of fan assembly on cooling tower of capacity 50TR complete all as specified and directed.
Supply and fixing fan assembly dia 1500 mm with alignment of fan blade for cooling tower of capacity 50TR complete all as specified and directed.
S&F in replacement sluice valve of size 150 mm dia flanged of class 1.6 PN having brass/SS spindle with check nut and iron wheel on top of the valve with duly ISI marked tested, complete all as specified and directed. Make :- Kirloskar/Kartar/Audco.
All as per item No. 37 here-in-before but of size 100mm dia, complete all as specified and directed. Make :- Kirloskar/Kartar/Audco
S&F in replacement 150 mm butterfly valve having IS-13095 short pattern PN 1.6 Class-125 duly lSI marked EPDM rubber lining seal, stainless steel disc including changing holding coil etc complete all as specified and directed. Make :- Kirloskar/Kartar/Veson/Audco
All as per item No. 39 here-in-above but size 100mm dia, complete all as specified and directed. Make :- Kirloskar/Kartar/Veson/Audco
All as per item No. 39 here-in-above but size 80mm dia, complete all as specified and directed. Make :- Kirloskar/Kartar/Veson/Audco
S&F in replacement stop cock cast copper alloy screwed type of size 20 mm dia, complete all as specified & directed.
All as per Srl item No 42 here-in-before but of size 40 mm dia, complete all as specified & directed.
Taking out unserviceable servo auto manual voltage stabiliser and transporting at work shop, opening of Voltage stabiliser of capacity 100/200/315 KVA and repair / replacement of unserviceable spare parts such as PCB/servo card, voltmeter 500v : 96mm-02Nos, 300V:72mm-03Nos,three phase control panel -01No, carbom bruses -12Nos, variac coil 200Amps, control transformer (CT) -02Nos, reinstalling at its original position after repair complete servicing and testing complete all as specified & directed.
S&F single phase preventer 230 Volts complete all as specified & directed. Make -L&T/IMP
S&F solenoid valve 1/4''dia 240 volt complete all as specified & directed.
S&F sensor for chiller plant 240 Volts of approved make complete all as specified & directed.
S&F water temp pressure gauge 0-150 PSI 6'' dia of approved make complete all as specified & directed.
S&F water temp pressure gauge 0-150 PSI 3'' dia of approved make complete all as specified & directed.
S&F industrial thermometer 0-60 degree centrigrade suitable for fixing with 100 mm dia water circulating pipe by means of proper welding and connection with checking the running water temperature complete all as specified and directed.
S&F water pressure gauge 0-150 PSI 4'' dia with cyfens and ball valve of approved make complete all as specified & directed.
S&F HRC fuse 200 Amp complete all as specified and directed.
S&F MCB SPN 63 Amp 240 volts make complete all as specified and directed.
S&F ammeter digital squire flush & CT type with CT's and rotary switch including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable one complete all as specified and directed. Make:- L&T/AE/ABB
Repairing and overhauling, commissioning and testing of AC compressor of plant No-2 ,plant No-3 plant No-8,plant No-9,plant No-13 & plant No-32, comprising of dismantling replacement of unserviceable components including, metaling grinding, polishing and refixing nuts, bolts, washers, gasket assembling the compressor testing on load complete all as specified and directed of the (i)Plant No-2(3x20TR)-2 No of 20TR (ii) Plant No-3(3x70TR)-1 NO of 70TR (iii)Plant No-8(3x35TR)-1 No of 35TR (iv)Plant No-9(3x50)-1 No of 50TR (v)Plant No-13(3x60TR)-1 No of 60TR (vi)Plant No-32(3x16TR)-1 No of 16 TR Note:-''Spare parts /Component will be measured &paid seperately under respective item of this schedule.
Repairing and overhauling, commissioning and testing of AC compressor of given plants{Plant No. 17 (3x5.57TR), Plant No18 (2x8.75TR),Plant No 19 (3X8.75TR), Plant No20 (2X8.75TR), Plant No 21 (3x5.5TR), plant No 22 (3x11TR),Plant No23 (3X11TR),Plant No24 (3x11TR) & Plant No 25 (3x11TR)},comprising of dismantling replacement of unserviceable components including, metaling grinding, polishing and refixing nuts, bolts, washers, assembling the compressor testing on load complete all as specified and directed. Note:-''Spare parts /Component will be measured &paid seperately under respective item of this schedule.
Supply only under mentioned spare parts for AC plants for maintenance & repair of compressor .
Connecting rod
Cylinder liner
Piston
Piston ring
Gajan pin
Section plates
Section read and discharge read
Oil pump
Loder assembly
Gasket sets complete
Tyre coupling with lock
Oil filter
Spring section
Spring ducting
Oil seal
Main bearing
Supply and fixing thermal magnetic adjustable type MCCBs including necessary fitting arrangement and testing complete all as specified and directed of following size.
125 Amps 3 pole breaking capacity 16 KA
200 Amps 3 Pole breaking capacity 36 KA
250 Amps 3 Pole breaking capacity 36 KA
400 Amps 3 Pole breaking capacity 36 KA
500 Amps 3 Pole breacking capacity 50 KA
Taking out unservicable MCCB s of any type any capacity by disconnection all electrical connection from panel board / wall /FPB complete all as specified and directed.
M&L for spray painting to AC plants (plant No-2,plant No-8,Plant No 9,plant No- 32) of following accessories like as compressors, condensers, pumps, motors, panels and pipes with two coat of synthetic enamel high glow paint Ist grade make Berger after preparation/cleaning of surfaces including write down the MES NO/SM NO complete all as specified and directed.
Detecting the fault of LT panel board of AC plants (Plant No-08 & Plant-13) by providing skilled tradesman & helper with necessary safety and working equipment such as multimeter, speedo meter and other required tools and rectified the defects on top priority basis including replacement of copper wiring of existing size cable and testing of interlocking system complete all as specified and directed
L-7 Primewave Communications
Radhe Krishn Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .