Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC MAHESMATI MALDA | L1 | Accepted-AOC L1-Accepted | |
| 2 | L2₹7.2 L+₹24,859 (3.57%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L2 | Rejected-Finance Higher than L1. | |
| 3 | L3₹7.5 L+₹53,207 (7.65%)Rejected-Finance BANDARAILAH MALDA | MALDA | MALDA | WEST BENGAL | L3 | Rejected-Finance Higher than L1. |
Tender Value
Refer Docs
EMD Value
₹14,450
Closing Date
5 Jan 2022, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, MALDA MECHANICAL DIVISION,PHED
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Supply, delivery and installation of Sludge Water Pumping Machinery set and repairing and rectification of PMCC panel at High Lift Pump House and other allied works for Sadipur Water Supply Scheme under Malda Mechanical Division, PHED.
2021_PHED_355051_2
WBPHED/EE/MLMD/NIeT_09 of 2021-2022
Open Tender
Electrical Work/ Equipment
Item Rate
45 days
Doulatpur PHE complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
4 documents required · 4 mandatory
₹14,450
Yes
18 Jun 2025
15 Dec 2021
7 Jan 2022
15 Dec 2021
5 Jan 2022
15 Dec 2021
120 days
Amount
Supply, delivery and storage at site of following materials for INCOMER PANEL:
250 A, 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic setting with O/L, S/C & E/F protection all complete
Spreader link broadened with phase barriers for 4P 250 A Thermal magnetic Microprocessor base MCCB
Extended door mounted rotary operator for 4P 250 A Thermal magnetic Microprocessor base MCCB
2 mm (14 gauge) CRCA panel mounted cubicle box with simens grey (RAL 7032) painting (dimension- 450 mmx 500mmx300 mm)
200 A, 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic setting with O/L, S/C & E/F protection all complete
Spreader link broadened with phase barriers for 4P 200 A Thermal magnetic Microprocessor base MCCB
Extended door mounted rotary operator for 4P 200 A Thermal magnetic Microprocessor base MCCB
96 sqmm, 3 Phase digital Voltmeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1. (Make- Schneider (DM3210)/ABB/ other approved make of equivalent type.)
96 sqmm, 3 Phase digital Ammeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1. (Make- Schneider (DM3110)/ABB/ other approved make of equivalent type.)
6 A, 240/415 V MCB of Breaking capacity 10kA & C characteristics
250/5 rated Current Transformer
LED type indicating lamp (Red 1 no, Green. 1 no. & Yellow 1 no.)
6sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
10 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 100 mtr)
16 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 100 mtr)
Charges for necessary disconnection of power line and dismentling of existing damaged or non serviceable spares following necessary precautionas and fitting fixing of supplied spares (as in items in sl. no 1.01 to 1.12 along with necessary mechanical and electical hardware as supplied by agency (such as screws, nut-bolts, washers, cable tie, pvc tape, sockets, MCB Channel etc) making internal connection by suitable size Cu wire as supplied in sl. no. 1.13 to 1.15 including cleaning of contacts by CRC 226 spray in the MCC panel board, cleaning of all terminal sockets, coils etc as per direction along with reconnection and testing of the main PDB panel under load condition up to the entire satisfaction of EIC.
Supply, delivery and storage at site of following materials for Outgoing Panel (For 20 HP Star Delta Feeder- 4 nos)
63 A, 415 V three Pole MCCB of Breaking capacity 25kA with fixed thermal and fixed magnetic setting with O/L, S/C & E/F protection extended door mounted rotary operator all complete
45 Amp. 3 pole power contactor (3TF46) having coil voltage 240V, 50Hz with 2 NO+2NC contact block
20-32 Amp. over load realy with kit (Make: SIEMENS(3UA58-Z1)/ other approved)
Star-Delta timer as per existing sample. (Make: GIC/ other approved)
SPGD2 with 1/40 current sensor (Make: Minilec/ other approved)
ALV D2 Phase Failure Relay - ALV D2 (Make: Minilec/ other approved)
32 amp TP MCB (Make: SIEMENS/ Havells)
60/5 rated Current Transformer (kappa/other approved)
3 pole contactor suitable for 12 KVAR Capacitor having coil voltage 240V, 50Hz.
7 KVAR heavy duty cylindrical type power factor correction capacitors. (Make: EPCOS/ other approved)
96 sqmm, 3 Phase digital Ammeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1. (Make- Schneider (DM3110)/ABB/ other approved make of equivalent type.)
LED type indicating lamp (Red 8 no, Green. 8 no. & Yellow 4 no.)
Push button switches (start/stop) (Red 4 nos. & Green 4 nos.)
6 A, 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing enclosure and necessary connection
1.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
2.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
6sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
10 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 100 mtr)
16 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 100 mtr)
Charges for necessary disconnection of power line and dismentling of existing damaged or non serviceable spares following necessary precautionas and fitting fixing of supplied spares (as in items in sl. no 1.01 to 1.19 along with necessary mechanical and electical hardware as supplied by agency (such as screws, nut-bolts, washers, cable tie, pvc tape, sockets, MCB Channel etc) making internal connection by suitable size Cu wire as supplied in sl. no. 2.15 to 2.19 including cleaning of contacts by CRC 226 spray in the MCC panel board, cleaning of all terminal sockets, coils etc as per direction along with reconnection and testing of the main PDB panel under load condition up to the entire satisfaction of EIC.
Supply, delivery and storage at site of following materials for 5 HP DOL Feeder (8 nos.):
16 Amp. MPCB having relay range10-16 Amp. with short circuit and overload protection. (Make: SIEMENS(3RV2021-4AA10)/ other approved)
10 Amp. MPCB having relay range 7-10 Amp. with short circuit and overload protection. (Make: SIEMENS(3RV2021-1JA10)/ other approved)
6 A, 240/415 V TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing enclosure and necessary connection
22 Amp. 3 pole power contactor (3TF33) having coil voltage 240V, 50Hz.
96 sqmm, 3 Phase digital Ammeter with LED indicators having current accuracy 0.5 as per latest IEC 61010-1. (Make- Schneider (DM3110)/ABB/ other approved make of equivalent type.)
Additional contact block suitable for above contactors in Sl. No. 2.03 (NO 8 nos. & NC 8 nos.)
6-10 Amp. over load realy with kit (3UA5200-1G)
4-6.3 Amp. over load realy with kit (3UA5200-1G)
6 A, 240/415 V MCB of Breaking capacity 10kA & C characteristics
20/5 rated Current Transformer within existing feeder panel and necessary connection
On dealy Timer. (Make: GIC/ other approved)
5 Amp Auxiliary Contactor (2NO+2NC) (Make: SIEMENS(3TH30)/ other approved)
WLCD1 with sensor (Make: Minilec/ other approved)
LED type indicating lamp (Red 8 nos. Green 8 nos. Yellow 8 nos.) (Make: SIEMENS / other approved)
Push button switches (start/stop) (Red 8 nos. & Green 8 nos.)
1.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
2.5 sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
6sqmm 1.1 kv grade PVC insulated copper flexible FR wire (each coil 90 mtr)
Charges for necessary disconnection of power line and dismentling of existing damaged or non serviceable spares following necessary precautionas and fitting fixing of supplied spares (as in items in sl. no 3.01 to 3.14) along with necessary mechanical and electical hardware as supplied by agency (such as screws, nut-bolts, washers, cable tie, pvc tape, sockets etc) making internal connection by suitable size Cu wire as supplied in sl. no. 3.16 to 3.18 including cleaning of contacts by CRC 226 spray in the MCC panel board, clening of all terminal sockets, coils etc as per direction along with reconnection and testing of the 3 nos. starter panels under load condition up to the entire satisfaction of EIC.
EI WORKS:
Earthing with 50 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of Solid GI wire (no.8 SWG) on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Supply & Fixing 240V, 18"dia 920 rpm of AC exhaust fan (EPCElectrical Pvt. Ltd.-Heavy Duty or equivalent of Orient/usha)incl. cutting holes on wall S/F louver shutter aluminium with nuts bolts washers etc. on wall & mending good the damages to original finish as per direction of EIC.
Suppy & Fixing of 18watt wall mounted LED Batten with polycarbonate housing & integrated electronic driver . Make - Philips/havells or other approved
Supply & Fixing only pendent light fitting complete with 9W LED lamp(M-Philips/Havells/Crompton Greaves), shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendent holder
Suppy & Fixing Eight module plastic surface box, 240 Volts 6 amp one way switch (8 nos).(Make- Legrand /Anchor/Havells/ any other approved make).
Body Derusting and Painting of entire unit of PMCC Panel with two nos. coats of paint with light grey (RAL 7032) painting of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint as per direction of EIC.
SLUDGE WATER PUMING MACHINERY:
Supply,delivery and storage of folowing Pumping Machinery set at site with following specification: Pump: Discharge-11.5 LPS, Head-15 M, Suc.X Del.- 80 mm X 80 mm Motor: Power Rating- 3.7 KW/5 HP, Rated Voltage- 415 V, Rated Speed- 1420 RPM, Impeller Dia-224 mm, Liquid to be handled : Max. Particle Size-15.5 mm, PH Value- 4-10, Max Sp. Gr.-1.2 , Efficiency not less than 65% (Make- Kirloskar Brothers Ltd. (Model- SP 3L+ or equivalent)/KSB/ other approved) Performance curve and guarantee certificate of pump to be submitted at the time of delivery.
Supply, delivery at site and storage of 1.1KV grade, 6 sq mm 3core, XLPE, Al. Ar. cables for newly supplied Pump set under sl no. 4.01 (Make : Gloster/ KEI / Polycab/any approved)
Installation of above items from sl.no. 4.01 on new foundation base including supply of all erection materials, individual delivery pipe and common delivery (as per site requirement), associated alteration of civil works suitable for above mentioned pump from recirculation chamber upto entry of inlet well, pipe supports as required for installation of pumping machineries, cables, jointing kits, cable supports and clamps, cable conduits etc. including laying of LT cables through GI conduits / trays, earthing and lightning protection as per IE rules including testing commissioning upto entire satisfaction of E.I.C.
MAKE AS PER DEPARTMENTAL APPROVED VENDOR LIST CIRCULATED VIDE MEMO NO.PHE/IV/2277/W-181/19 DATED- 25/09/2019
Add GST @ 12%
Add GST @ 1%
DEY ENTERPRISE
NABAUDYAG ELECTRICAL ENGINEERING CO OP. SOC. LTD.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .