| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.7 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹34.3 L+₹46,037.30 (1.36%)Rejected-Finance A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹36.0 L+₹2.2 L (6.54%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹37.1 L+₹3.3 L (9.75%)Rejected-Finance | 4 | Rejected-Finance Not being lowest |
Tender Value
₹43.4 L
EMD Value
₹86,800
Closing Date
5 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Agra
112, Taj road, Agra Cantt
ADDN ALTN OF BLDG NO.E-54, OFFRS MESS, SIKH LI RC AT FATEHGARH
2024_MES_640902_1
86172/E8
Open Tender
Civil Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted for class D and above and category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹86,800
29 Apr 2024
6 Feb 2024
12 Mar 2024
6 Feb 2024
5 Mar 2024
20 Feb 2024
6 Feb 2024 - 13 Feb 2024
Amount
S&F Steel work in tubular trusses/purlins (curved/straight) including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed
S&F Joist, channel, angle, or tee sections, ISMB etc fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (Gde E- 250) quality A complete all as specified and directed
S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe 410-W (Gde E- 250) quality A ) complete all as specified and directed
M&L for two coat of synthetic enamel paint over a coat of red oxide including preparation of new steel surfaces over 10 cm in width or girth not otherwise described complete all as specified and directed
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in curved/plain roof covering/ cladding to wall, fixed with self tapping screws as specified and directed
S&F Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in curved/plain roof covering/cladding to wall, gutter, valley, ridge etc, fixed with self tapping screws complete all as specified and directed.
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRC false ceiling tile of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter?locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main?T runners of size 15 x 32 mm of length 3000mm,cross T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L?shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in charge
M&L for Excavating in trenches in soft soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out complete all as specified and directed.
Excavating in post holes( or similar holes) each n exc 0.5 cu.m. getting out, returning, filling in and ramming earth of broken rubble mixed with earth around, in layers not exceeding 25 cm, watring, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed
S&F Mild steel screw bolts of 11-15 mm dia and length of bolt exc 5cm but n exc 10cm long (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square complete all specified and directed
M&L Hardcore (broken stone) of gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 10 cm thick in plinth protection, watered and rammed to a true surface complete all as specified and directed
M&L for plain cement concrete in post hole Type B2 1:2:4 ( 40 mm graded aggregate) complete all as specified and directed
M&L Plain Cement concrete type D2 (1:4:8) , 40mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified and directed
M&L 75mm thick Cement concrete type D-2 , 1:4:8 (40 mm graded aggregate) for sub base of flooring complete all as specified and directed
M&L 25mm thick Cement concrete type B-0 , 1:2:4 (12.5 mm graded aggregate) for sub base of flooring, finishing cement concrete surface without using extra cement even and smooth including necessary form work complete all as specified and directed
M&L 75mm thick Cement concrete type C-2 , 1:3:6 (40 mm graded aggregate) finishing cement concrete surface without using extra cement even and smooth in plinth protection including necessary form work complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and dried in any mortar and rubbish off the premises complete all as specified and directed
M&L Green Marble slabs of required size and shade of 18-20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing types including 15mm screed bed in CM 1:6 complete all as specified and directed
M&L for Vitrified Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles exc. 0.42 sqm but not exceeding 1.00 sqm, light/dark shade in colour, double charge/GVT as in floors,skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement including Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including Rendering 10mm thick CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed
M&L for Removing excavated soils exc 250 m but not exc 500 m and depositing where directed complete all as specified and directed
Returning filling including spreading, leveling, watering and well ramming in layers n.exc. 25cm for soft/loose soil complete all as specified.
Demolition of brickwork masonary built in lime or cement mortar including all quiens arches, pillars etc. But including concrete articles complete all as specified and directed
M&L for Brickwork using old size brick with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius with CM 1:6 complete all specified and directed
-ditto- all as per above but except Bricks etc complete all as specified and directed.
M&L half brick thick walls built in CM 1:4 Sub Class B bricks straight or curved on plan to any radius complete all as specified and directed
M&L for 12 mm thick Toughned glass as in wall panellig/Vertical surfaces including stainless steel cleats, silicon sealant for gap filling and all necessary items for fixing and similar work including cutting to shape, drilling holes required complete all as specified and directed by Engr-in-Charge
S&F 12mm thick Toughened glass as in doors including coloured Glass etching, Stainless Steel Big L-Patch, Stainless Steel Bottom Patch Fitting, Stainless Steel Top Patch Fittings, Stainless Steel 300mm Glass Door Handle on both side of door, Glass door lock stainless steel, Stainless Steel Cleats etc and all necessary fitiings to fix the door complete all as specified and directed by Engr-In-Charge Note:- Floor Door Spring shall be measured and paid separately
M&L for Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed
Taking down cement plaster on brick wall or stone wall etc. including raking out joints hacking for key, scrubbing down with water etc and disposed off unserviceable material complete all as specified and directed
M&L for 15mm thick cement plastering in cm 1:6 on brick or concrete surface fair finished the surface even and smooth without using extra cement all as specified and direcetd
M&L for 15mm thick cement plastering in cm 1:4 on brick or concrete surface inlcluding chajja etc fair finished the surface even and smooth without using extra cement all as specified complete all as specified and directed
M & L Rendering 10mm thick in CM (1:3) on fair faces of ceilling concrete surfaces to be finished even and smooth without using extra cement complete all as specified and directed
M&L Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over a weather coat wall care putty of 1mm thickness over new plastered surface to prepare the surface even and smooth complete all as specified and directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre including priming coat of acrylic primer applied over new surfaces providing and applying wall care putty of 1mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm each not exc 4.00 sqm each and refixing the same in other opening complete all as specified and directed
Preparation of old roof surfaces by brooming and watering, clearing all dust particles and providing PCC type B-0 1:2:4 using 12.5 mm graded stone aggreagte as in padding/levelling course of average thickness not exceding 50 mm including making kerbs at wall and roof junction complete all specified ad as directed
M&L for Rendering 15mm thick on fair faces of concrete surfaces including roof and other like surfaces in CM 1:4 with Coarse Sand finished even and smooth with Neeru Finishing to plastering surface with WPC @ 3% of weight of cement (WPC shall be measured and paid separately) complete all as specified and directed
Supply only integral waterproofing compound complete all as specified and directed
M&L for provoding 40mm thick cement concrete 1:2:4, Type B-0 in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed
M&L Finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over a weather coat wall care putty of 1mm thickness over old plastered surface to prepare the surface even and smooth including complete removal to exisitng treatment complete all as specified and directed
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre including priming coat of acrylic primer applied over a coat of wall care putty of 1mm thickness over old plastered surface to prepare the surface even and smooth including complete removal to exisitng treatment complete all as specified and directed
Material & Labour for Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified andf directed
S&F Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples size of staples 12mm complete all as specified and directed
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fastenersand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down copper / aluminium sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
(a) One light/ holder/fan/exhaust fan/bell point controlled by one switch.
(b) One 5 pin 5 Amp switch socket combination point on an independent board.
(c) One 5 pin 5 Amp socket point controlled by one switch on same board.
All as per item 51 here in before but for one 15 Amp 5/6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified.
S&F modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket, 6A -2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket, 16A -2/3 pin combined 2 module complete all as specified and directed.
S&F white cover plate with frame 1 module complete all as specified and directed
S&F white cover plate with frame 3 module complete all as specified and directed
S&F white cover plate with frame 6 module complete all as specified and directed
S&F white cover plate with frame 8 module complete all as specified and directed
S&F Ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.) complete all as specified and directed
Supply and fixing of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.
Supply and fixing of MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.
S&F of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed.
S&F in replacement of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F MCB in replacement of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, hldrs & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F building security LED Light 20 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel trip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core and complete all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out soft / loose soil complete all as specified and directed for laying of under ground cable, foundation of pole and stay etc complete all as specified and directed.
M&L for returning, filling in including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
M&L for removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning for U/G cables in layers of 23 cm thick (8 cm bore laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Punned down volume shall be measured.
M&L Supply and lay burnt best quality locally available old size sub class 'B' briks laid in trenches perpendicular to UG cable for cable protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. (Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
M/S WASEEM KHAN CONTRACTOR
m/s udit constructions
M/S Shree Gopal Engineers & Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .