Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹45.0 L+₹1.1 L (2.55%)Rejected-AOC | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹47.8 L+₹3.9 L (8.94%)Rejected-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹51.2 L+₹7.4 L (16.9%)Rejected-AOC | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹65.1 L+₹21.3 L (48.5%)Rejected-AOC BLDG 9 FLAT 130 MIRA CO OP HOUSING SOCIETY LTD SALISBURY PARK GULTEKDI PUNE 411037 | PUNE | PUNE | MAHARASHTRA | 411037 | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
₹49.6 L
EMD Value
₹99,300
Closing Date
1 Feb 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8317 CERTAIN SPECIAL REPAIRS AND REVENUE / MINOR WORKS IN THE AREA OF EME PUMP HOUSE, MINTSD, DAD RESIDENTIAL COMPLEX, OFFICERS ACCN OF CARRIAPPA ENCAVE / LAWRENCE ROAD/ CEPZ MESS UNDER AGE E/M SOUTH PUNE
2022_MES_499445_1
8317 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
183 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹99,300
Yes
11 Mar 2022
4 Jan 2022
3 Feb 2022
4 Jan 2022
1 Feb 2022
19 Jan 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. and getting out in the following type of strata complete all as specified and as directed :-
Soft/Loose soil
Hard/ Dense soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick Soft/Loose soil/ Hard/ Dense soil complete all as specified and as directed.
Removal of excavated material [soil] of any strata to a distance not Exc 50 m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified and as directed.
M&L for Reinforced concrete pipes, class NP2 with one collar per lengh of pipe of 150 mm dia, half round (02 Nos for top & bottom) complete all as specified and as directed.
Taking up or down carefully steel water tubing and connection from trenches, wall & floor including cleaning of serviceable pipes for refixing of size 15mm bore in new and old position in wall, ceiling, floor and trenches or removal to store all as specified and directed.
All as per Sr. Item No. 05.00 above but of size 20 mm bore complete all as specified and as directed.
All as per Sr. Item No. 05.00 above but of size 25 mm bore complete all as specified and as directed.
All as per Sr. Item No. 05.00 above but of size 40 mm bore complete all as specified and as directed.
All as per Sr. Item No. 05.00 above but of size 50 mm bore complete all as specified and as directed.
Supply, laying and testing Galvanized steel water tubing 80 mm, medium grade, including provision of specials such as bends, elbows, tees, unions etc laid in trenches including taking up or down old unserviceable pipe complete all as specified and directed
Supply and laid in trenches / floors / walls / ceilings pipe galvanised medium class incl fittings 50mm bore complete all as specified and as directed.
All as per Sr. Item No. 11.00 above but 40mm bore complete all as specified and as directed.
All as per Sr. Item No. 11.00 above but 25mm bore complete all as specified and as directed.
All as per Sr. Item No. 11.00 above but 20mm bore complete all as specified and as directed.
All as per Sr. Item No. 11.00 above but 15mm bore complete all as specified and as directed.
S & F stop Valves cast copper alloy, screw down high pressure with crutch or butterfly handle screwed both ends for iro pipes or for unions and fixed on 50 mm bore GI pipe ISI marked complete all as specified and as directed
All as per Sr. Item No. 16.00 above but of size 40mm bore ISI marked complete all as specified and as directed.
All as per Sr. Item No. 16.00 above but of size 25mm bore ISI marked complete all as specified and as directed.
S & F bib taps 20 mm bore Brass ISI marked complete all as specified and as directed.
S & F bib taps 15 mm bore Brass ISI marked complete all as specified and as directed.
Supply and fix sluice valves of class 1.0 PN flanged of 80 mm bore complete all as specified & directed
Supply and fix Foot valve confirming to IS 4038, 80 mm bore complete all as specified & directed.
Supply and fix cast iron non return (reflux) valve flanged ends in swing type design as per IS 5312 Pt-1, PN-1.0 with bypass arrangement 80 mm bore complete all as specified & directed
S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
Supply and fix Pressure guage 4" dial 0-10 Kgs rating with control valve complete all as specified & directed
M & L for cutting existing GI tubing for alteration or addition of sizes including screwing existing GI tubing for tapping & making new connections etc for 20mm bore complete all as specified and directed
M & L for cutting existing GI tubing for alteration or addition of sizes including screwing existing GI tubing for tapping & making new connections etc for 50mm bore complete all as specified and directed
Supply and fix rotational moulded polyethylene water storage tanks (vertical cylindrical with closed top) double layered with ISI marked with existing inlet, outlets & provision of washouts (vent pipe all as directed of capacity 1000 litr including dismantling old unserviceable tank complete all as specified and as directed.
All as per Sr. Item No. 28.00 above but 500 litr complete all as specified and as directed.
Dismanting old unserviceable existing pump set and foundation from site and removing to MES Storeyard complete all as specified and as directed.
Supply, install, test and commisioning of mono block pumping sets with CI impeller to discharge (16.4 ltr/sec) at 22 mtr head at including 3 phase, 415 volts, 50 Hz electric induction motor mounted with base frame made out of ISMC 75 mm channel suitable fixed to the foundation as per manufacturer instructions with necessary fixing arrangement and consist of (a) PCC foundation and height as per manufacturer instruction to match existing suction and delevery pipe (b) Suitable size GI suction and delivery pipe with all joiningmaterials to match the exising suction 80 mm and delivery 65 mm pipe (c) PVC drain pipe 25 mm from foundation to outside the pump house building all as per manufacturer's instructions and as specified & directed by Engr in Charge. (Make of Pump- Kirloskar / Crompton Greaves / KSB)
Design, supply,install, test and comissioning of Star Delta Starter Panel of suitable size for indoor installation factory made both front and rear side double door system, fabricated with 2.0mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of 7 tank process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 300Amps rating TPN bus bars of high conductivity aluminium alloy and half neutral with aluminium bus bar RYB insulated complete and shall be provided with colour coded heat shrinkable sleeves,with with sufficient depth of the panel for accommodating all switchgears in the panel. The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade, 3 phase 415 Volts , 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54. Contd...
Supply,fixing,testing and commissioning of cubicle panel board Outdoor type weather proof ,vermin proof, double door pedestal mounted fixed on angle iron frame of size 40x40x5mm with 3mm thick CRCa sheet,powder coated seven tank process and locking arrangement comprising of the following items including dismantling of old unserviceable panel board complete all as specified and as directed. (a) MCB TPN 32A,10KA - 01 (b) DOL starter for 3HP with motor protector relays - 01 (c) Single phase preventer - 01 (d) Motor dry run protector with sensors and signal cable from panel to static water level and draw down level of bore well (e) Amp Meter 0-10A (f) Voltmeter 0-500v - 01 (g) RYB indicator lamp LED - 01 set (Set of 3)
Supply, laying, testing and commissioning of UG LT cables of size 50 Sqmm 3.5 core, 1100 volts grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminum conductor, heavy duty conforming to IS - 1554 part-I, including cable glands, crimpimg type cable lugs in LT panel / MCCB in bldg etc to suit the cable laid in trenches / fixed to poles/drawn through pipes complete all as specified and as directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanised steel strip or wire armoured, electric control cable (heavy duty) with stranded copper conductor of size 4 core 4 sqmm complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode '60cm × 60cm × 6mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less than 1.5 metres below normal ground level', connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron or steel earth strip protected by provision of GI 'medium grade' pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thick cover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape,
Item No. 36.00 Contd.... including GI 'medium grade' 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of phosporous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point all as specified or indicated 'including testing on completion. (NOTE :-GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit rate)
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32 x 6 mm galvanized iron strip, complete all as specified and directed.
Supply, fixing and testing LED IP 66 roadway luminarie with suitable size bracket high power LED as light source and electronic driver for 45 Watt LED efficacy 100 lumens/watt CCT 5700K,CRI>70 PF 0.95,IP66,IK 07 SP5KV interval & 10 KV,SPD external, complete all as specified and directed. (Make : WIPRO Cat Part No : LR06-611-XXX-57-XX or equivalent model in Bajaj/Phillips)
Supply, fixing and testing LED IP 66 roadway luminarie with suitable size bracket high power LED as light source and electronic driver for 60 Watt LED efficacy 100 lumens/watt CCT 5700K,CRI>70 PF 0.95,IP66,IK 07 SP5KV interval & 10 KV,SPD external, complete all as specified and directed. (Make : WIPRO Cat Part No : LR13-671-XXX-57-XX or equivalent model in Bajaj/Phillips)
Supply, fixing and testing LED IP 66 roadway luminarie with suitable size bracket high power LED as light source and electronic driver for 70 Watt LED efficacy 100 lumens/watt CCT 5700K,CRI>70 PF 0.95,IP66,IK 07 SP5KV interval & 10 KV,SPD external, complete all as specified and directed. (Make : WIPRO Cat Part No : LR13-781-XXX-57-XX or equivalent model in Bajaj/Phillips)
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300mmx300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing as per IS 1161 and pole shall be conforming to IS-2713 ( Part II),1980 type 410-SP-31 (9.0 meters long) LT poles including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting complete all as specified and directed
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed by Engineer- in-charge.
Material & labour PCC 1: 3 : 6 type C-1 (using 20mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed.
Supply and laying unreinforced precast concrete cover class LV type I, flat size 250mmx150mmx 40mm all as directed by Engineer in charge.
Supply and spreading fine dry river sand for cushioning to UG cable including spreading, levelling and hand punning etc. in clause 19.75 of SSR Part I (Note : The punned thickness shall only be measured for payment.)
S&F thermoplastic cable junction box with weather proof for out door installation IP 66/67 protection grade of two terminals suitable for cable entry 10 -25 sqmm of size 205x255x112mm including necessary clamps for fixing arrangement complete all as specified and directed. (Make :- Hensel Cat No KF2525G or of equivalent make in Sintex)
Supply only PVC insulated sheathed wire 1.5 Sqmm ,3 single core with copper conductor of colour red,black and green for connection street light fittings from over head line/pole boxes complete all as specified and directed.
Supply & fixing twin core flat 6 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed all as directed.
Supply & fixing Street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed in replacement with MS Clamps, nuts, bolts and washers on pole complete all as specified and as directed. (Note : clamps, nut bolts to be measured and paid for separately)
S&F in steel water tube light grade of size 50 mm bore conforming to IS 1239 of 1990 for for protection of LT cable fixing on wall / trenches/pole etc including taking out the same as directed by Engineer-in-charge .
M&L for Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to Galvanised earth lead wire of dia 4.0mm by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009
Supply, laying, testing and commissionnig of UG LT cables 16 sqmm 4 Core 1100 volts grade, XLPE insulated, screened and PVC shealhed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/ connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall complete all as specified and as directed.
M&L for laying of Reinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 100 mm, 2 nos half round (for bottom and top) and before laying exacaved area shall be leveling all as specified and directed Engr-in-charge.
Diamantling of Steel tubular poles/struts any size complete all as specified and as directed.
Dismantling of old unserviceable street light fitting any type and size complete all as specified and as directed.
Taking down unserviceable cable of any size from trenches / walls / poles complete all as specified and as directed.
M & L for point wiring complete with and including single core FRLS PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 4.0 Sqmm 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as required at site, on walls/floors/ceiling including all conduit accessories/fittings/junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls including 4.0Sqmm 1100V grade FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 15A power point on independent board continutiy wire with 4.0 Sqmm cable (including connecting ot earth dolly) laid/fixed in surface conduit on walls/ceiling and also including sunk typed pressed steel terminal box and 3mm thick plastic laminated sheet top covers for independent power point controlled by one number one way 15A switch complete
S&F switch flush type 15 Amp 240 Volts single one way (ISI marked) complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15A, 240 Volts (ISI marked) complete all as specified and as directed.
Supply fix MCB DB of sheet metal enclosure double door SPN 4 way with 200 Amps rated bus bar 230 volt and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed.
Supply MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed.
Supply MCBs, SPN 32Amps, 10 KA , IS/IEC 60898-12002 marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and as directed.
M&L for galvanised tubing 25 mm medium grade with all fittings laid in trenches all as directed by engineer in charge.
M&L for Cutting existing steel tubing for alterations or additions 40 or 50 mm bore complete all as specified and as directed.
M&L for Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector 40/50 mm bore of pipe complete all as specified and as directed.
M&L for gun metal globe or gate valve with iron wheel head,screwed both ends for iron pipe suitable for 25mm bore GI tubing complete all as specified and as directed.
Supply, installation, testing and commissioning of water boosting system with electric driven pump set 1.0 HP, discharge 15 to 108 LPM, Head 44 to 10.5 M upto 6 Kg / sqcm and expansion tank 24 litre (horizontal/vertical) complete all as specified and as directed.
M&L for GI fittings 25mm bore such as union, nipple, long screws, barrel pieces, bends and elbows as per site requirement complete all as specified and directed
Supply and fix Automatic Transfer Switch 200A, Four pole AC-31A, 50Hz, 415V with controller in sheet metal enclosure mounted on wall with the help of anchor fasteners incl necessary electrical connections all as specified and directed (Make: HAVELLS /SOCOMO)
S&F Vertical Distribution board 8Way, VTPN in sheet metal enclosure double door, factory made fixed flush with wall inside niches for mounting MCBs 415 Volts with bus bars with front conforming to Model : Ekinox³ of make Legrand or of equivalent make specified here-in-after complete all as specified and as directed.
S&F MCCB four pole 160A, 25KA, DPX3 model all as specified and directed
S&F MCB TPN 63A, 415V, C-curve complete all as specified and directed
Taking down carefully Exhaust fan safely from the site and transporting to MES store yard for keeeping in safe custody complete all as specified and directed.
Taking down carefully old unsv Geysers safely from the site and transporting to MES store yard for keeeping in safe custody and collecting new geysers from E/M store yard to site complete all as specified and directed
Supply and Fixing Exhaust fan AC single phase 240V Bahar metallic grey body of size 300mm sweep without louver shutter and all fixing arrangements etc conforming to Cat Part No. SKU Code 70001 of Bajaj or of equivalent model in Almonard / Havells complete all as specified and directed by engineer in charge.
Supply and Fixing Water heater storage type of capacity 25 ltrs suitable for 230 volts 50 Hz single phase AC supply with 5 Star rating with safety valve, Thermostat and NRV conforming to Bajaj Cat Part No. SKU Code 150761 White Colour or equivalent model in Racold / Havells including necessary fixing arrangements in stone/brick masonary wall and hot and cold water pipe connected to water supply line all as directed.
S&F PVC flexible connection for hot and cold water supply of size 15mm x 600mm with brass nuts all as specified and directed
S&F gunmetal gate valves high pressure, with crutch or butterfly handle, screwed both ends screwed both ends for iron pipe or for unions of 15 mm bore complete all as specified and directed.
M&L for replacement of 15mm bore GI tubing medium grade, ISI marked, with all fittings, fixed to wall, ceiling, laid in floors, concealed in wall, roof, beam etc including clips, wall hooks etc or laid in surfaces/floors or concealed in walls/floors all as specified and directed
S&F Anchor fasteners 8mmx100mm fixed on wall all as specified and directed
Excavation in trenches n.exc. 1.5 m wide but depth exceeding 1.5 mtr and upto 3 mtr and getting out in soft/loose soil complete all as specified and as directed
Takshashila electricals
Chaulya Enterprises
CHAITANYA WINDWELL
Vijay Construction and Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .