Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.3 LAccepted-AOC AT POTAPOKHARI P O NAYABAZAR DIST CUTTACK PIN 753004 | CUTTACK | CUTTACK | ODISHA | 753004 | ₹77.3 L | L1 | Accepted-AOC Selected through lottery |
| 2 | L1₹77.3 LRejected-AOC WARD NO 51 P O NAYABAZAR P S MADHUPATNA DIST CUTTACK PIN 753004 | CUTTACK | CUTTACK | ODISHA | 753004 | ₹77.3 L | L1 | Rejected-AOC Not selected in lottery |
| 3 | L1₹77.3 LRejected-AOC | ₹77.3 L | L1 | Rejected-AOC Not selected in lottery |
| 4 | L1₹77.3 LRejected-AOC | ₹77.3 L | L1 | Rejected-AOC Not selected in lottery |
| 5 | L1₹77.3 LRejected-AOC | ₹77.3 L | L1 | Rejected-AOC Not selected in lottery |
Tender Value
₹91.0 L
EMD Value
₹90,988
Closing Date
6 Jan 2026, 6:00 pmClosed
Divisional Officer
RURAL WORKS DIVISION, CUTTACK
Renovation and Interior furnishing of conference hall building and installation of 8 passenger Lift for R.W.Circle, Cuttack for the year 2025-26
2026_CERWI_124090_1
RWD Ctc-14/2025-26
Open Tender
Civil Works - Buildings
270 days
Cuttack
Refer tender documents
3 documents required · 3 mandatory
₹10,000
₹90,988
Yes
16 Mar 2026
1 Jan 2026
7 Jan 2026
1 Jan 2026
6 Jan 2026
1 Jan 2026
1 Jan 2026 - 5 Jan 2026
Dismantling and removing cement concrete including stacking the useful materials for resue and removing the debris within 50 m lead etc. complete. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Dismentalling and removing doors, windows and ventilators including removing the frames hinges fastening and stacking the same for reuse and refixing them after necessary repair etc. complete as per specification and direction of the Engineer-in-Charge. a). First Floor
b). Second Floor
c). Thirid Floor
Dismentalling of brick or stone masonary in lime or cement mortar under 3mtr. Height including stacking the useful materilas for reuse and removing the debrises within 50m lead etc. complete as per specification and direction of the Engineer-in-Charge. a). First Floor
b). Second Floor
c). Third Floor
Dismantling and removing old tiled flooring including removing the base courase and stacking the useful material for reuse and removing the debris with 60 m lead etc. complete. a). Second Floor
Dismentalling and removing old lime or cement plaster from wall surface including racking out joints 12mm deep and removing the debrise away from the work site including all labour T&P articles . required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Second Floor
Earth work in excavation in foundation in all kinds of soil including earth mixed with boulder (except sheet rocks and boulder requiring blasting) with all leads and lifts including dressing and levelling the bed and depositing the excavated earth at places away from work site with all leads and lifts including cost of all labour ,T&P and dewatering if required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
Supplying filling in foundation and plinth with sand in layers not exceeding 22.5cm (9") thick including watering and ramming with cost conveyance, royalities, taxes of the materials and labour with T&P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
Providing Cement Concrete (1:3:6) with 40 mm down graded of crusher broken hard granite stone aggregate of approved quality from approved quarry for cement concrete work including hoisting, lowering and laying in position in layers with proper packing and ramming by means of vibrator to proper slope and level including cost of curing for 28 days, conveyance, royality , taxes of all materials required for the work, running and hire charges of machineries and all T & P required for the work, labour charges for the work complete in all respect as per the specification and direction of the Engineer-in-charge. a). Ground Floor
Fly ash brick masonary in cement mortar (1:4) in foundation and plinth and basement and ornamental flower bed plinth moulding and similar such types of works with all necessary projections using fly ash . bricks of 9"/10" size having a crushing strength of not less than 35kg/cm2 including splays cutting circular moulding chamfering and corbelling watering and curing after immersing the bricks in water for six hours before use etc., complete including cost and conveyance of all materials and labour required for the work with all taxes and royalties etc. with all T&P complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
R.C.C. work in C.C. M-250 using 12 mm to 20mm size (20 mm not be exceed 25%) hard black crusher broken granite stone chips of approved quality and from approved quarry including hoisting lowering, laying & compacting concrete watering and curing for 4 weeks including smooth, rigid centering, shuttering & finishing the exposed surface smooth with cost, conveyance, royalities and taxes of all materials and labour, T& P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S rods or tor steel and binding wire and labour charges for straightening, cutting, beinding, binding etc. and tying the grills and placing in proper position as per direction of the Engineer-in-charege. a). Column Base Ground Floor
b). Column Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
c). Plinth Beam Ground Floor
d). Lintel Ground Floor
Second Floor
First Floor
Third Floor
Fourth Floor
e). Chajja Ground Floor
d). Roof Beam Ground Floor
First Floor
Second Floor
Third Floor
e). Roof slab Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Supplying, fitting and placing HYSD bar reinforcement complete as per drawings and technical specification Clauses 1000 and 1200 of MoRD and as per direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
d). Fourth Floor
Fly ash brick masonary in cement mortar (1:4) in superstructure using fly ash bricks of 9"/10" size having a crushing strength of not less than 35kg/cm2 including splays cutting circular moulding chamfering and corbelling watering and curing after immersing the bricks in water for six hours before use etc., complete including cost and conveyance of all materials and labour required for the work with all taxes and royalties etc. with all T&P complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Thirtd Floor
e). Fourth Floor
6mm thick C.P. in C.M (1:4) to RCC surface finished smooth including slury treatment including watering and curing with cost, conveyance, royality, taxes of all materials & labour with T& P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-charge. a). Ground Floor
b) First Floor
c). Second Floor
d). Thirtd Floor
e). Fourth Floor
12mm (1/2") thick cement plaster (1:6) finished smooth to outside brick wall surface after racking out the joint including watering and curring with cost ,conveyance, royality, taxes of all materials and labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
16mm (5/8") thick cement plaster (1:6) finished smooth to inside brick wall surface after racking out the joints including watering and curing with cost, conveyance, royality, taxes of all materials and labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Providng and fixing Vertified tiles in floors treads of steps and landing on 25mm thick bed of cement mortar (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing with all cost, conveyance, taxes of marble / tiles , labour with T&P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c) Second Floor
d). Third Floor
Providing and fixing vertified tiles in dados, skirting and riser of steps on 12mm thick cement mortor (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles inlcuding rubbing and polishing with all cost, conveynace, taxes of marble / tiles labour with T& P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Providng and fixing Chequired tiles in floors treads of steps and landing on 25mm thick bed of cement mortar (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing with all cost, conveyance, taxes of marble / tiles , labour with T&P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
Supplying, fitting and fixing of dressed seasoned sal wood work framed and fixed (wrought & putup) in trusses, purlins, frames, rafters, doors, windows, ventilators and beams including cost, conveyance, taxes with all labour, T&P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
32 mm both side laminated factory made Flush door shutter including cost of fitting , fixtures and labour for fixing in position etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
c). Third Floor
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6 mm thck glass of approved quality including cost of fitting , fixtures and labour for fixing in position etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Providing, supplying, fitting and fixing of 80 mm thick interlocking concrete paver block on compacted river coarse sand free from all organic materials and filling the joints with sand including cutting, corbelling, splayes whereever necessary to proper size with cost, conveyance , royalities of all materials and as directed by Engineer-In-Charge. a). Ground Floor
Supplying, fitting & fixing of Granite Tiles of minimum Above 0.4 sqm (10mm. thick) of approved make in dadoes laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Providing, fitting and fixing of M.S. Door, M.S Windows, M.S. Grills ,M.S. Grill Gate and Collapsible Gate with top and bottom rails in proper position including making holes in walls, RCC structure and wood work in proper position etc. and making good to the damages to walls or RCC structures including mending, or cutting to sizes or grooves in walls and fixing with CC (1:2:4) with hard black crusher broken granite stone chips of 12mm to 20mm (1/2" to 3/4") (20mm not to exceed 25% ) with cost ,conveyance, royality, taxes of all materials, labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
Providing and Fixing of Structural Glazing approved make to be febricated from roll formed sections made of prepainted steel(base steel as per IS-513 of 0.6mm thick 'D'quality galvanized as per IS-277 with zinc of120gm per sqm) with primer of 5 - 75.7microns thick and finished paint with po-lyster paint ( Black / Pearl white / Chocolatebrown) of12-16microns along with the alkydbacker at the back of 5-7 microns and thesizes of outer frame being 46 x 52mm andwith all vertical & horizontal mullions are of46 x 70mm and fixed beading are of 18 x 25mm. Sections for internal top and bottomframes in the louvered area should be 18 x40mm. Top hung shutter should be 46x46mm. Accesories/ ed beadings are of 18x25mm. Accessories/ gaskets are to be used as per the manufacturer's supply and specification like handle being made of high grade aluminium powder coated and with nylon recever and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be glass filled nylon. The sections are to be cut to length jointed and assembled by means of corner bracket and frames are fixed to the concrete / masonry walls by means of self expanding screws and glass to be used with safety laminated glass of 12.38 mm thick with 0.76 mm inter layer Poly Vinyl Butyral (PVB) lamination between two glass with outer being 6 mm thick toughened reflective of Reflactsol series of Saint Globain & inner glass being of 6mm thick toughened clear of Saint Gobain makewith all taxes. a). First Floor
b). Second Floor
c). Third Floor
Priming one coat to the new wood / iron work including cost, conveyance, taxes of primer, sand papering, labour with T&P required for the work etc. complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
Finishing wall surface of wall with Acrylic wall putty of approved make and finished smooth and even surface to relive painting including cost of scaffolding staging charges with cost of all materials taxes labour T & P etc. complete. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
Wall painting one coat with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint, including all labour, T&P etc., complete as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
Finishing walls with weather coat of approved shade on new work/old work two coats to give an even shade including scaffolding, staging charges with cost, convyeyance, taxes of all materials, labour with T&P required for the work etc. complete as per specifiation and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
Painting two coats with any approved enamel paint to new wood work and iron work including cost of the primer and paint sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge. a). Ground Floor
b). First Floor
c). Second Floor
d). Third Floor
e). Fourth Floor
Supplying, fitting, fixing of Cup boared with Openable shutter made of 18mm Pre-laminated particle board in bottom, top & side wall & back side with 9mm Pre-laminated particle board both side decorative including magnetic locking arrangement, Cromium coated handel 75mm with 125 x 25mm / 100mm with 150 x 25mm & 2nos drawers provide with 20" telescopic channel including cost, conveyance, taxes of all fittings & materials, cost of all labour, T&P etc. complete as per direction of Engineer-incharge. a). Second Floor
Providing fitting and fixing of wall paneling aluminium section B9835 as Horizontal and vertical member placed @600 mm C/C covered with 18 mm thick WPC bouard plain colour and 4 mm thick veneer of approved quality with melamine polish with all cost, labour T&P required for the work etc. complete as per direction of Engineer-in-charge
20mm(3/4") thick grading plaster with cement mortar (1:4) over roof slab after chipping and chiselling the same and cleaning the surface by wire brush laid to proper slope finished smooth to receive tarfelt treatment watering and curring including cost ,conveyance, royality , taxes of all materials and labour with T&P required for the work etc. complete in all respect as per specification and direction of the Engineer-in-Charge a). Second Floor
Providing ,Fitting& fixing Decorative Roller Blinds to Scenings including cost and conveyance of all materials to site, and all labour charges complete as per direction of the Engineer -in- Charge. a). Second Floor
.Providing and Fixing Toughened Glass door with 12 mm thick including Floor spring and lock , handles complete in all respect.
E.I. Work Recessed wiring to Light point/Fan point/Call Bell/Exhaust Fan Point with 1.5 sqmm, FR PVC Insulated single core multistrand copper conductor of ISI marked with 20 mm dia non- metallic PVC flexible conduct with 5 Amp, 250 V Modular type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.5 sqmm FR PVC insulated single core multistrand copper conductor and earth wire incouding all accessories and connection as per direction of engineer in charge (Make of wire = Finolex/L&T/ Anchor/ V-Guard) deducting the cost of 2M Box with cover Plate-1 No.) (1.1.3-1.24.2) -do- Group C
Surface wiring to call bell/buzzer point in 20 mm dia rigid pvc conduit heavy duty ISI marked conforming to IS 9537/1983 part- III With 2x1.5 Sqmm single core copper wire ISI mark conforming 694/1990 and earth continuity in 1,5 Sqmm copper wire with metallic switch board of size 150mmx100mmx62mm made of 1.22mm M.S sheet including provision of earth screw painted with one cote of red oxide paint and two coat of gray enamel paint confirming to IS 5133 part-I,1969 with 3mm thich bakelite/phenolic laminated front cover fixed with steel screw and ceiling rose of ISI marked on board. including supply and fixing of 5A.250V flush type switch of ISI marked including all accessories and connections. (CB-3) Long point
S/F to 16/18 SWG Modular GI box of following sizes (normal sixe) in recess with suitable size of Modular Base & Cover in front including cutting the wall and making good the same in case of recessed conduit as required. '-do- 6 Module
-do- 12 Module
-do- 18 Module
S/F of 6M GI box on surface or in recess with suitable size of Modular base cover cover in front including providing and fixing of 2 nos 3 pin 5/6 amp. Modular Socket out let & 5/6amp. Modular type switch,connection,painting etc. as required (1.26)
S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 32A DP Modular Switch with neon Indicator & 5 pin 15/16 amp. piano type Modular Socket & Mini DP MCB, connection, painting etc as required for AC
S/F of 1 no of 5 pin 15/16 amp. Modular Socket , 1 no of 15/16A Modular switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
Sub-Main Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.5 (1.8.1)
Inverter wiring (1x1.5smm) Copper wire (1.19.1)
MCB S/F of 'B/C/D' series DP MCB of 63amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the 2 Way double door MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b)
S/F of 'B/C/D' series TPN MCB of 5 - 32A amp rating (As per direction of engineer in charge) 440Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required without MCB box(2.6.4)
Supply and fixing of following size MCB box with sheet steel enclosure, distribution board, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland /plate, interconnection, phosphate and powder painted including earthing etc. as required ( But without MCB/ RCCB/ ISOLATOR)Make-Legrand/L&T/Greatwhite/C&S. S/F of 4 way (4+12) TPN MCB DB Single door (2.5.1)
Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ( (2.15A)+(1.24.16 )
S/F of 63A. TPN Bus bar
S/F of Cu .Earth Plate Earthing 600 mm x600mmx3.15mm with Salt & Charcoal for Earth electrode (3:5)+(3.6)
S/L of 25mm x 5mm Cu. earth strip in 40 mm dia G.I.Pipe(3.11)
S/F OF 2-Ton Cassette AC unit details stringent specifications ensuring an efficient and reliable HVAC system. The specification requires a ceiling-recessed type unit designed for aesthetic integration, featuring a decorative grille and a 4 way multi-directional airflow panel with motorized louvers to ensure uniform cooling of the space. Key performance metrics include a cooling capacity of approximately 24,000 BTU/hr (equivalent to 2 TR) and a high Energy Efficiency Ratio (EER) or Indian Seasonal Energy Efficiency Ratio (ISEER) rating of 3.5 or higher, ensuring energy compliance and performance. The system must operate on a reliable power supply of 230V, single phase, 50Hz, utilizing an eco-friendly R-410A or R-32 refrigerant. The equipment list includes the supply of the indoor unit (IDU), outdoor unit (ODU) with a highly efficient rotary or scroll compressor, interconnecting refrigerant piping, insulated drain piping, all required electrical wiring from the nearest junction box, and a user-friendly wired or wireless remote control MAKE -hitachi, Daikine, mistubisha
Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar 2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos 5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad)
Provision of Armoured cable size 3 1/2 x70sqmm (27)
Lift (8 Passanger) Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) -do- Group B
Recessed wiring to Fan Point in -do- Group B
Swich Boards S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board
S/F of extension board of 4 modular Metal box with modular base & cover in recess including providing and fixing of 1 nos of 3pin 5/6amp modular socket out let & 1 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 12 Modular box with base & cover
Sub-Main Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x2.5+1x1.5 (1.8.2)
Circuit Breakers S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) . S/F of MCB 4 way Double Door (2.3.5 )
Earthing Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18)
S/F of Cu .Earth Plate Earthing 600 mm x600mmx3.15mm with Salt & Charcoal for Earth electrode (3:5)+(3.6)
Fittinngs Installation, Testing & Commissioning of 1No. automatic 8 PASS-4STOP-SSH-MRL-1MPS (G+3) (4 Stop), including , speed 1m/s, Stainless Steel Hairline Finish with ARD system with inspection certificate from electrical inspector and as per Direction of Engineer-in-charge complete in all respects as per Technical Specification Attached. 1.Elevetor Grouping Simplex Full coollective Control 2.Full collective Control 3. Well Dimension 1750mm width and 1750mm depth (required) 4. Head Room height 3800mm (required) 5. Pit Height 1400mm (required) 6. MAP Floor position Topmost floor (Top) 7.Car dimensions 1100mm wide x 1300mm dep x 2300mm high 8. Hoistway dimensions 1850 mm W x 1700mm D 9. Door type Two panel centre opening plain panel Finishes:- Rear Mid Panel-Glass Panel Rear Corner Panels-Glass Panel Side Mid Panels-Polka Delite Front Panel-Polka Delite False Ceiling Finish -Stainless stell Mirror Finish Ventillation-Cross flow fan Machine-PM Geraless (Located in shaft on top of guide rails) Door opening-800 mm W x 2100 mm H (Make: OTIS / Kone /JOHNSON / Thyssenkrup).
Supply and fixing of 300mm Exhust fan with all accessories and connections (Make:Usha-Aero Clean Plus DBB/Crompton- Trans Air 12" reversiable /Havells-Venti Air DS (HS)/Anchor- Anmol delus R/Orient-Power Flow DBB// Pollycab -Fresh on DBB )
S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections (Make:HPL/ Havells/PAC/Crompton/Polycab)
S/F of 10w Watt LED Bulb
Cables Provision of Armoured cable size 3 1/2 x 35sqmm (25)
Laying of MV cable above 25sqmm to 120 sqmm in ground (5.1.2)
Laying of MV cable above 25sqmm to 120 sqmm on surface (Horizontally)(5.5.2)
TV , Sound Systyem , Projector, Computer, Printer S/F OF 65, inch 4K Ultra HD Smart LED Google Resolution: 4K Ultra HD (3840 x2160) | Refresh Rate: 60 hertz | BRAVIA 2 LED Connectivity: 3 HDMI ports to connect set top box, Blu Ray players, gaming console | 2 USB ports to connect hard drives and other USB devices, Sound: 20 Watts Output | 2ch [Open Baffle Speaker | Dolby Audio 12 Full Range (44.5 x 106mm) Smart TV Features: Google TV | Watchlist | Google Assistant | Chromecast Built In | Game menu | ALLM/eARC (HDMI 2.1 Compatible) | Additional Features: Apple Airplay | Apple Homekit | Alexa Display: 4K LED | 4K Processor X1 | Live Color | 4K X-Reality PRO Motionflow XR 100 | HDR10/HLG, MAKE-SONY/ SAMSUNG/ LG
1 KVA UPS,Make-Microtech
S/F of 1 no of 5 pin 15/16 amp. Modular Socket , 1 no of 15/16A Modular switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover.
Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard)
Supply and fixing of 32A double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
Supply and fixing of 63A double pole (single pole and neutral) 240 V residual current break (RCCB) having a sensitivity current up to 300 milli ampere in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
Supply and fixing of 400 mm wall fan with all accessories and connections (Make:Usha-Maxx Air Ultra /Crompton- WM Hiflow wave /Havells-Accelro(HS)/Anchor- Altrix HS- OWH /Orient-Wall 43/ Great White - WYNO WF/ Pollycab -Aery HS )
S/F of 2250 VA/24V Inverter with 2 nos. 180Ah battery including trolley arrangement (Make: V-Guard/ Microtake/ Luminous
S/F of 6W LeD Square (6"×6") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic)
S/F of 12W LeD Squre (10"×10") LSDSMN-12W-WW with surface Panel rings (Havels/crompton/philips/panasonic)
Table pop-up box, also known as a cable cubby or integrated desktop socket, outlines detailed specifications for a flush-mounted connectivity solution in conference tables or workstations. The unit is typically specified as a modular, flush-mounted box with a pop-up, flip-up, or hydraulic damping mechanism for soft opening, ensuring discreet integration when not in use. The housing material is usually durable extruded aluminium or CRCA metal with a finish like matte silver or black, while internal modules are made from fire-resistant engineering plastic (e.g., UL94 V0 standard). The core of the specification lies in its connectivity configuration, which typically mandates multiple universal 3-pin power sockets (rated 250V AC, 13A/16A), a specific number of RJ45 CAT-6 data ports, and essential AV interfaces such as 4K HDMI, VGA, and 3.5mm audio jacks. Modern BOQs also require USB charging ports (Type-A/C, often with fast charging PD capabilities) and data transfer ports. The entire assembly must conform to relevant electrical and safety standards like CE certification and IS codes MAKE - LEGRAND L&T,SCHNIDER
110 MM PVC electrical trunking specifies a robust containment system for surface-mounted cable routing, ensuring safety and organization in commercial or industrial settings. The trunking must be made from high-impact, rigid, self-extinguishing Polyvinyl Chloride (PVC) compound, ensuring fire resistance and compliance with standards such as IEC 61084-2-1. Key physical specifications include a clean, uniform finish, usually pure white or light grey, with dimensions specified precisely (e.g., 50mm x 25mm or 100mm x 50mm) and a standard length per section of 2 or 2.5 meters. The material must be UV stabilized for longevity, resistant to common acids, alkalis, and oils, and capable of operating within a standard temperature range. The design requires a robust, integrated hinged lid or a secure clip-on cover for easy access during installation and maintenance MAKE - legrand , l&t schnider
S/F of 4k 25 mtr HDMI CABLE MAKE - honeywell ,ad net,
P.H. Work Supplying all materials labour T&P and providing brick work with Fly ASh Bricks having c. s. not less than 75Kg/cm2 with dimensional tolerance +-8% in cm (1:3)including watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per specification and dir of EICIn F&P in cm (1:3)
Supplying all materials labour T&P and providing c.c. (1:1.5:3) using 12mm hg chips for RCC works including hoisting laying, watering, curing, conveyance of all materials to work site payment of royalty taxes etc. all complete as per specification and direction of EIC
Supplying all materials labour T&P and providing MS reinforcement for RCC works including cutting, bending, binding and tying the grills and placing in position including cost of binding wire and 18 to 20 gauge conveyance of all materials to work site payment of royalty, taxes etc. all complete as per specification and direction of EIC.-
Supplying all materials labour T&P and providing rigid and smooth centering and shuttering for RCC works including false work and dismantling them after casting including conve4yance of all materials to work site payment of royalty, taxes etc. all complete as per specification and direction of EIC-
Supplying all materials labour T&P and providing cement plaster on brick/stone work including watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per specification and direction of EIC.12mm thick CP (1:3)
Supplying all labour materials T&P and fixing of 2 RCC baffle wall precast with cc (1:1.5:3) using 12mm bhg chips for fitted to septic tank as per PH specification and direction of EIC
Supplying all materials labour T&P and providing precast RCC manhole cover with cc (1:12:3) of 12mm hg chips including conveyance of all materials to site after payment of royalty and taxes etc. all complete as per PH specification and direction of EIC-(size 550mmx550mmx76mm)
Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the door frames shall conform to RV-TIFAC composites Design Centre's standards and specifications. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the E.I.C
Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gel coat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrene(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reinforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/Light grey/ Mahogany/Teak wood or any other colour using high quality pigments. Three heavy weight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Dismantling and removing old tiled flooring including removing the old base and stacking the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the E.I.C
Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep, stacking the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the E.I.C
Supplying all materials labour T&P and fixing porcelain glazed tiles/Marble tiles /Kota /Kodappa tiles in dados skirting on 12mm thick cp (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rub bins and polishing complete as per direction of EIC
Supplying all materials labour T&P and fixing Ceramic tiles in floors. Treads and landing on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigments to match the3 shades of the tiles including rub bins and dir of EIC
Supplying all materials labour T&P and cutting holes through brick/stone masonry works including making good the damages in cm (1:4) for taking GI/PVC pipes and fittings etc. all complete as per PH specification and direction of EIC. (a) 250mm thick wall for water supply
(b) Cutting hole through RCC Roof
(c) Groove Cutting through wall or floor
Supplying all materials, labour, T&P and fixing wash down water closet(E.W.C) with integral 'S' or 'P' trap to the floor with wooden plug and C.P screw including jointing the trap with soil waste pipe in C.M(1:1) etc all complete as per specification and direction of the E.I.C. Wall mounted water closet
Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipeby means of white lead mixed with chopped hemp etc all complete as per specification and direction of the E.I.C. Porcelain half stall urinal Magnum Urinal
Cost of 15mm dia urinal spreader
Supplying all materials labour T&P and fitting & fixing UPVC SWR soil waste ventilating pipes and fittings of the following OD conforming to ISI No.13591/1992 to walls with nails bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method as per manufacturers specification testing e. w. in excavation in all kinds of soil and refilling of trenches as per direction of EIC. 110mm dia PVC Pipe
110mm dia U-PVC S. Trap
110mm U-PVC S/J with Door
110mm U-PVC door bend
110mm dia U-PVC Plain bend
110mm U-PVC Cowl
125mm dia CP Grating
75mm dia plain bend
75mm dia pipe
Supplying all materials labour T&P and fixing wash basins with hole for pillar taps with CI/MS brackets painted white including holes in walls and making good the damages etc .all compt. As per PH sp. And dir. Of EIC. 550x400mm WHB-
WHB-Padestrill
Counter top basin 560x455 (Parryware make) white
Supplying all materials labour T&P and fixing mirror of superior glass mounted on 6mm thick AC sheet or plywood sheet and fixed to wooden plugs with cp screws and washers compt. As per PH specification and direction of EIC.600x400mm BE Mirror (fixed type)
Supplying all materials labour T&P and fixing standard size cp towel rail/ring compt. with cp brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of EIC. a)CP Towel rail
CP Towel ring
Supplying all materials labour T&P and fixing standard size cp soap holder compt. With cp brass brackets fixed to wooden plugs with cp screws as per PH specification and direction of EIC. CP soap holder
Supplying all materials, labour T&P and fitting and fixing C.P shower with 15mm or 20 mm inlet with C.P shower arm including polishing all complete as per P.H. specification and direction of EIC. 15mm dia cp Revolving shower
Supplying all materials labour T&P and fitting and fixing 10 ltr capacity low level flushing cistern with a pair of cast iron or m.s. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float, c.p. brass handle, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia cp foush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main etc. all complete as per specification and direction of EIC.
Supplying all materials labour T&P and constructing gully trap chamber of the following inside size with 8cm thick RCC precast cover slab in cc (1:1.5:3) using 12mm size hg chips foundation concre3te(1:3:6) using 40mm size hg metal on bed and around trap KB Brick work in cm (1:6) in F&P and inside 12mm thick cp (1:3) finished with a floating coat of neat cement including fixing 100mm size HCI gully trap and grating etc. all complete as per approved drawing specification and dir of EIC. Inside size 250mmx250mm gully trap
Supplying all materials, labour T&P and construction of Inspection chamber of the following sizes with c.c.(1:3:6) using 40mm size hg metal on bed, Ist class KB Brick work in cm(1:6) moulding and shaping the channel inside and benching with c.c. (1:1.5:3) with punning to inside cement flush pointing (1:3) to outside RCC cover slab in cc (1:1.5:3) using 12mm size hg chips with RCC m. h. cover, e. w. in excavation in all kinds if soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to site payment of royalty taxes etc. all complete as per approved specification and direction of EIC. Inside size : 760 x 760 x 460mm Inspection Chamber
Supplying all materials labour, T&P and constructing soak way pit of the following sizes with precast RCC rings joined loose gravel backing in the rear of well staining, precast RCC cover slab in c.c. (1:2:4) USING 2mm size hg chips fitted with iron lifting handles including e. w. in open well excavation in all kinds of soil and refilling the cavity around the pit and painting the iron works watering, curing, conveyance of all materials to work site payment of royalty, taxes etc. all complete as per approved drawing, specification and direction of EIC.- 0.91m dia x 2.10m deep
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C.- 1.20m dia x 2.10m deep
Supplying all labour materials T&P and laying of UPVC soil waste pipe of the following internal diameter confirming to IS in trenches of the depth upto 1.2mtr including jointing with supply of approved rubber, lubricant by non heat application method on bending with 150mm thick cc (1:3:6) using hg metal of 25mm to 40mm and then making all-round encasing including earth work excavation in all kinds of soil, refilling the trenches watering, curing, conveyance of all materials to site payment of royalty, taxes etc. & testing all complete as per PH sp and dir of EIC 110mm dia with Allround encasing
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing all complete as per specification and dir of EIC. a)20mm dia C- PVC Pipe
25mm dia C- PVC Pipe
32mm dia C-PVC Pipe (external)
40mm dia C-PVC Pipe (external)
Supplying all Materials labour T&P and fitting and fixing brass/CP Fittings of the following nominal bore with supply of all jointing materials etc. complete as per PH Specification and Direction of EIC.All are CP fittings Jaquar make a)15mm dia CP pillar cock
20mm dia cp concealed stop cock
15mm dia cp angle stop cock
15mm dia cp bib cock S.B.
15mm dia cp bib cock L.B.
25mm dia PVC Valve
32mm dia brass or gun FWV
40mm dia brass or gun FWV
15mm dia CP flange
15mm dia CP Extension piece
Supplying all materials labour T&P and fixing water storage sintex tanks including and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting and placing the to the required position, including cost of tank conveyance and taxes of all materials to work site etc. all complete as per PH specification and direction of EIC. ( 2000 lit sintex tank)
Supplying all materials labour T&P and construction of masonry staging with providing 1st KB brick work in cm (1:6) of 0.40mtr height in staging and in circular protection wall to support to the tank 12mm thick cement plaster in cm (1:4) over brick work RCC beam of 2.61 x 0.25x0.30 using cc (1:1.5:3) using 12mm chips including centering and shuttering curing, conveyance of all materials to work site etc. all complete as per sp and dir of EIC. 2000 ltr capacity
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 1.76 MB
Tendernotice_1.pdf
PDF • 1.40 MB
BOQ_574063.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid