| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | ₹23.9 L Quoted ₹25.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹26.0 L+₹67,920.94 (2.68%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | ₹26.0 L+₹67,920.94 (2.68%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹26.5 L+₹1.2 L (4.62%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹26.5 L+₹1.2 L (4.62%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹26.6 L+₹1.3 L (5.27%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹26.6 L+₹1.3 L (5.27%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹28.3 L+₹3.0 L (11.7%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹28.3 L+₹3.0 L (11.7%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
18 Jun 2020, 6:00 pmClosed
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/maintenance of LT OH lines, LT UG cable, LT Poles, overhead Conductor, Voltage stabilizer, earthing, panel and connected accessories at MPH area under GE Utilities Udhampur
2020_MES_332279_2
GE/U-68/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹79,000
Yes
14 Aug 2020
26 May 2020
20 Jun 2020
26 May 2020
18 Jun 2020
4 Jun 2020
Amount
M&L in replacement of Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including GI strip of size 32 x 6mm to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 5 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion including taking out of old unserviceable earth plate complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earth will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engr -in-charge.
Taking out the existing unserviceable GI strip of size 32 x 6mm complete all as specified and directed by Engr-in-Charge.
Taking out the existing unserviceable rusted LT feeder pillar box alongwith busbar, MCCBs etc of any size/capacity including disconnection, breaking PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
Taking out the existing unserviceable rusted LT junction panel panel board alongwith busbar complete of any size/capacity including disconnection, breaking PCC foundation etc and disposed off complete all as specified and directed by Engr-in-Charge.
S&F of GI stip of size 32 x 6mm including fixing with suitable size of china clay insulator on wall/ducts/floor to panel complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of outdoor type,weather proof, cubicle panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable/openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete, suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
M&L of factory made sheet metal encloser (junction pannel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 75X75X45cm depth with front and rear openable double door with locking arrangement including 04 Nos strip aluminium bus bar of lengh 60 cm of 200 amps capacity, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.
M&L of factory made sheet metal encloser (junction pannel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 90X90X50cm depth with front and rear openable double door with locking arrangement including 4 Nos strip aluminium bus bar of lengh 75 cm of 400 amps capacity, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.
M&L of factory made sheet metal encloser (junction pannel) made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 85X85X50cm depth with front and rear openable double door with locking arrangement including 4 Nos strip aluminium bus bar of lengh 70 cm of 300 amps capacity, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs complete all as specified and directed by Engr-in-Charge.
Dismantling re-errecting,restringing tensioning and repair to overhead line ACSR conductor any size upto 5 conductor in one span as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and directed by Engr-in-Charge.
Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site complete all as specified and directed by Engr-in-Charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsiblr to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
Disconnection/taking out existing UNSV/damaged LT under ground cable/service cable of size 35 sqmm 3.5 core from trenches/ducts or from to poles/walls or under roads/paths/drains/culverts and depositing the same in the storeyard or disposed off complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 12.00 here-in-before but 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 95 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 120 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 150 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 185 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 12.00 here-in-before but 240 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Supply and Laying and fixing of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated (XLPE insulated) galvanized steel strip armoured electric cable of size 35 sqmm 3.5 core, 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area complete all as specified and directed by Engr-in-Charge. Note: - Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately.
Description all as per serial item No 20.00 here-in-before but 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 70 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 95 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 120 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 150 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 185 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 20.00 here-in-before but 240 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables/ pipes/foundations of poles/stays etc. not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 28.00 here-in-before but depth exc.1.5m but not exc. 3m complete all as specified & directed by Engineer-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed by Engr-in-charge.
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories complete all as specified and directed by Engr-in-charge.
Dismantling of unserviceable ACSR Conductor of any size from existing over head lines complete all as specified and directed by Engr-in-charge.
Dismantling of GI earth wire and guard wire from existing OH lines complete all as specified and directed by Engr-in-charge.
Dismantling of cross arms of MS fabricated complete with all accessories viz nut, bolts, washer etc complete all as specified and directed by Engr-in-charge.
Dismantling of unserviceable stay assembly complete with all accessories complete all as specified and directed by Engr-in-charge.
Taking down carefully old unserviceable insulator (any type/size) from existing over head lines complete all as specified and directed by Engr-in-charge.
M&L for ACSR conductor of required size for over haed lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor complete all as specified and directed by Engr-in-charge.
S&F shackle type insulator pocelain viterous LT 1100 Volt 100x115mm including M.S. strip washers, insulator bolts, nuts complete all as specified and directed by Engr-in-charge.
M&L for road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed by Engr-in-charge.
S&F tubing 'light grade' galvanised iron of size 80 mm bore with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/ washers or laid in floors/under roads complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 43.00 here-in-before but 50 mm bore complete all as specified and directed by Engr-in-charge.
Unbinding and restreching of GI earth wire 4 mm dia on LT/HT poles & cradles at road crossing including binding with 1.63 mm dia GI binding wire complete all as specified and directed by Engr-in-charge.
M&L for aluminium thimble cable (Lugs) suitable for Cable of size 50 Sqmm complete all as specified and directed by Engr-in-charge. Make: Dowells/Eqvt
Description all as per serial item No 46.00 here-in-before but of size 70 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 95 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 120 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 150 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 185 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 240 Sqmm complete all as specified and directed by Engr-in-charge.
Description all as per serial item No 46.00 here-in-before but of size 300 Sqmm complete all as specified and directed by Engr-in-charge.
S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engr-in-charge. Note: - The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-charge.
M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engr-in-charge.
S&F stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I complete all as specified and directed by Engr-in-charge.
Supply, fabricating and fixing in repairs cross arms ( any type) supports, bracing, stiffeners anti climbing spikes etc made out of MS channel, angle iron, flat of any size including drilling of holes making clamps including eye hooks, nuts bolts and washers etc welding if required including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M&L for GI earth wire 8 SWG(4mm dia) on poles for continuous earth wire and for guarding cradles including binding to required shape with binding wire complete all as specified and directed by Engr-in-charge.
M&L for painting to steel tubular swaged pole of Overhead lines (9 Mtr long) complete with and including comprising the following works:- (a) Scraping out wornout old paint and making the surface smooth complete all as specified and directed by Engr-in-charge.. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) complete all as specified and directed by Engr-in-charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engg.-in-charge) synthetic enameled paint and marking pole no. with black and white paint complete all as specified and directed by Engr-in-charge.
S&F LT Line spacers rigid type 4/5 wire complete all as specified and directed by Engr-in-charge. Make: Pactil/Atlas/Raychem (RPG)/Jaipuria
M&L for surface cleaning from sub stations by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30 cm and averaging 15 cm deep including sweeping removing the same to distance not exceeding 50 m away from the installation and burning the same complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , Ics=100%Icu- 35 KA, 415 Volts, 400 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
S&F in replacement MCCB 4 pole , Ics=100%Icu- 35 KA, 415 Volts, 250 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-charge.
Opening,maintenance and general servicing of Servo vottage stablizers of different makes (Rating from 50 KVA to 100 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils, checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Servo Motor with RC Net work having torque of 3 Kg/cm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Servo Motor with RC Net work having torque of 10 Kg/cm complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electronic Control Card for Automatic Voltage regulation complete all as specified and directed by Engr-in-Charge.
S&F in replacement of wiring of Electronic Control panel complete all as specified and directed by Engr-in-Charge.
M&L for top up of transformer oil (ISI Marked) suitable for existing voltage stablizer as per IS 335 part-1 complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Auto/Manual switch for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of main indicators for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of micro press switch for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of voltmeter of capacity 0-300 volt for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of voltmeter of capacity 0-500 volt for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Ammmeter CT operated for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of carbon Brushes of capacity 50 KVA-100 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
M&L for rewinding of variac coil conforming to the original specifications of the servo stablizer of any make/capacity with super enamelled cooper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete all as specified and directed by Engr-in-Charge.
S&F in replacement of circuit plate of capacity 50 KVA-100 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of push button of capacity 50 KVA-100 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of pulse transformer of capacity 50 KVA-100 KVA for voltage stablizer of any capacity and size complete all as specified and directed by Engr-in-Charge.
M&L for welding of broken feeder piller doors,indoor/out door using butt hinges appropriate size and making proper locking arrangements of doors complete all as specified and directed by Engr-in-Charge.
M& L for preparation of old painted surface of feeder piller boxes indoor /outdoor and applaying two coat of synthetic enamal paint complete all as specified and directed by Engr-in-Charge.
M&L for painting steel and iron surfaces with synthetic enamel paint two coats over a coat of red oxide primer including surface preparation of E/M instalations, pipes, machines, valves, panels, transformers, sign boards or as directed any size shape complete all as specified and directed by Engr-in-Charge.
Supply and replace conventional indicating lamps & holder with LED indicating lamps with holder of R,Y&B colours, 230 volts AC Supply complete prewired with suitable size of copper wire complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 630 Amps, with adjustable thermal and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 200 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole, Ics=100%Icu- 25/26 KA, 415 Volts, 100 Amps, with thermal adjustable and fixed magnetic setting with extended terminals complete all as specified and directed by Engr-in-Charge.
M&L insulation tape of 25 mm width in R-Y-B-B colour combination complete all as specified and directed by Engr-in-Charge.
Disconnecting/taking out existing unserviceable / damaged LT underground cable/Service cable of size 16 Sqmm 4 Core from trenches /ducts or from to poles/walls or under roads /paths/drains/culverts and depositing the same in the storeyard or disposed off complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 12.00 here-in-before but 16 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 12.00 here-in-before but 10 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing LT underground cable of size 16 Sqmm 4 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts complete all as specified and directed by Engr-in-Charge. Note: - Excavation and GI Tubing earth work shall be measured and paid seperately under respective item of Sch 'A'.
Description all as per serial item No 12.00 here-in-before but 16 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 12.00 here-in-before but 10 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge.
MOHAN LAL AND SONS
slathia construction works
FANGALIA TRADERS
vijay kumar gupta and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .