Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.1 L+₹65,250 (10.1%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.1 L+₹66,381 (10.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.6 L+₹1.1 L (17.3%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Non submission of shortfall documents |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
2 Jul 2025, 12:00 pmClosed
The Executive Engineer, Kolkata Electrical Div
The Executive Engineer Kolkata Electrical Division P.W.Dte. BlockI (1st Floor) Writers Buildings, Kolkata 700 001
SITC of Air Conditioning machines along with allied works related to air conditioner at P and AR Department, Writers Building Block IV 2nd Floor writers Building.
2025_WBPWD_862941_1
WBPWD/EE-KED/eNIQ-08Q/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Writers Buildings
Please refer Tender documents.
5 documents required · 5 mandatory
₹13,000
O/O The Executive Engineer Kolkata Electrical Divi
25 Sept 2025
12 Jun 2025
4 Jul 2025
12 Jun 2025
2 Jul 2025
20 Jun 2025
19 Jun 2025
Amount
SITC Microprocessr Controlled, DX Type ceiling suspended Ductable Air conditioner Unit(as per latest QCO) with all necessary acessories for hanging Indoor& Outdoor unit as per site condition having following specification i) Refrigerent-R410A/R407C ii) Expansion Valve:Thermostatic/Electronics iii) Compressor :Single/Twin Scroll Rotary with Fixed speed v) ODU: Outdoor Unit Air cooled Condenser unit With Copper coil with Aluminium fins having single compact ODU or multiple ODU unit vi) IDU: Indoor Unit having synthetic Filter and wireless/Wire Remote Vii) CFM: 400/Tr viii)Protection: Single Phase Preventer, phase reversal preventer, HP/LP cut Out. ix)Power sypply: 415+/- 10%, 50Hz x)Ambient temperature: 48°C +/- 5°C (Tollerance) Make: (Make:Hitachi/Daikin/ Blue Star/Voltas/carrier/ O-General/ Mitsubishi Heavy) no extra shal be payable for refrigerant gas & transportation/shifting work.
Min : 29.5 KW (1 nos. compressor)
Fire Damper: Supplying, Fixing, testing and commissioning of Fusible link type fire damper.. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire in indoor motor and temperature rise above 62 degree centrigate (Make: Carryaire/ Dynacraft/ TSC/Ravistar/ Systemair/Jonson Control)
REFRIGERANT PIPING WITH INSULATION: Supply & Laying Hard / Soft drawn Copper Refrigeration pipe line for liquid and suction line suitable for R410A/R407C refrigerant & 19 mm thick Nitrile Rubber 'class O' Insulation tube with supports & brackets as per direction of EIC.
Liquid Line ( 5/8" dia) without rubber insulation (make: Rajco / Mandev / Royku)
Suction Line (7/8" dia) with 19 mm thick nitrile rubber insulation Al foil covered (make: Rajco / Mandev / Royku)
Supplying, fabrication & fixing M.S. Angle Frame for installation of 1 no Outdoor unit . the structure having 5 nos 50 x 50 x5 mm MS angle for main bottom support grouted on wall with total length 16' and in between main support 7 nos 25 x 5 mm ms strip . For railing vertical & horizontal support is made by 25 x 25 x 5 mm Angle for safety of maintenance , total length 35' ; including cutting holes , welding , painting and mending good damage as per EIC
DRAIN PIPE Supply and fixing of Drain piping by UPVC with 6mm thick nitrile rubber insulation and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc:
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 3 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 4 core x 2.5 mm² (Make- RR Kable / Finloex / Polycab).
Fabrication , supply, Installation , testing & commissioning of following GSS(120 GSM) sheet conforming to IS:655 – 277 (SAIL/ TATA/ JINDAL or as per choice of EIC) rectangular/round duct complete with neoprene rubber gaskets, elbows, splitter supports, flanges, turning vanes for supply air / return air duct erected with supporting rods, fustners, nuts etc. -
Supplying and fixing of 13mm thickness duly laminated aluminium foil of mat fininshed closed cell Nitrile rubber (class ''O'') insulation ANTI MICROBIAL COATING type on duct after applying two coats of cold setting adhesive (The joints shall sealed with 50mm wide and 3 mm thick self afhesive nitrile rubber tape insulaton complete as per specifications and as required. for Duct (K-Flex / Amracell / Supreme / K-Flex)
DUCT ACOUSTIC INSULATION: Supplying & fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber(class O) of density 140Kg/cu.m-160 Kg/Cum insulation with bolts nuts GI washers etc as required. (Make - Armacell / K Flex / Supreme/ A-Flex)
Supply & Fixing of powder coated supply air GI volume control damper with diffusers Make - Premire /Systemair / Air Enterprise / Caryaire /Airmaster
Providing and fixing fire retardant nonporous double layer flexible connection between each indoor unit and duct as per direction of EIC.
S.R. REFRIGERATION AND APPLIANCES (BID ID -6659846)
TRANSTECH (BID ID -6646926)
Lyric International (BID ID -6665897)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .