| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.9 LAccepted-AOC A 2 206 SAI DWARKAMAI NIBM ROAD KONDHWA PUNE 411 048 | PUNE | MAHARASHTRA | 411048 | 1 | Accepted-AOC lowest bidder | |
| 2 | 2₹35.7 L+₹1.8 L (5.23%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | 2 | Rejected-Finance quoted rate rate high | |
| 3 | 3₹42.3 L+₹8.4 L (24.7%)Rejected-Finance | 3 | Rejected-Finance quoted rate rate high |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
13 Jun 2023, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8426 REPAIR TO ROOF, PLUMBING, JOINERY, FLOORING, PLASTERING, PATH, INTERNAL ELECTRIFICATION AND CONNECTED ITEMS TO CERTAIN BLDG OF JCOS, OR AND CIVILIAN MD ACCN UNDER AGE BR-II (SOUTH) PUNE
2023_MES_596154_1
8426 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹94,000
15 Jul 2023
17 May 2023
15 Jun 2023
17 May 2023
13 Jun 2023
1 Jun 2023
Amount
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of old unserviceable AC sheet (corrugated or semi corrugated) / PVC sheet in roofing including ridges etc complete all asspecified & directed.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as of roof covering / ridges fixed with self tapping screws including dismantling of old unserviceable sheet complete all as specified & directed.
S&F mild steel tubes, angles etc fixed independently without connecting plates as in purlins etc all complete including Dismantling wrought iron or mild steel iron of any description not otherwise provide for complete all asspecified & directed.
Taking down chowkhat or frames exc. 1.5 sqm but not exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
Taking down chowkhat or frames wooden / steel not exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
Taking down shutters of any description exc. 1 Sqm each and not exc. 2 Sqm each, complete all as specified and directed.
S & F pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 105 x 60mm with and including MS hold fast - 3 Nos., MS cold rolld 100mm size butt hinges - 03 Nos., welding to existing MS frame, PCC bed block 1:2:4 type B1 for embadding hold fasts and plain cement concrete 1:3:6 type C1 (12.5mm graded stone aggregate) for filling in MS frame, complete all as specified & directed.
S & F pressed steel frames for doors with one & more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm with and including MS hold fast - 6 Nos., MS cold rolld 100mm size butt hinges - 06 Nos., welding to existing MS frame, PCC bed block 1:2:4 type B1 for embadding hold fasts and plain cement concrete 1:3:6 type C1 (12.5mm graded stone aggregate) for filling in MS frame, complete all as specified & directed.
S&F IInd class hard wood 35mm thick factory made, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneer particle board with commercial veneering on both faces. The size of the rail as per IS 1003 (Part-I) Kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F IInd class hard wood 35mm thick factory made, glazed and skeleton shutter open rebated and prepared to receive glass gauge etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. The size of the rail and stile as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F Solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, suppling and fixing in opening complete all as per specification and as directed by Engr-in-Charge
S&F factory made solid panel PVC door shutter 30mm thick (stiles) consisting of frame made out of M.S tubes for top & bottom rails; M.S frame shall be covered with heat moulded plain colour PVC ‘C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing as per product Drawing given on relavent page of SSR Part-II 2020 Refer item No. 8080 as specified and directed by Engr-in-charge.
S&F 100 mm size mild steel butt hinges medium weight, cold rolled, complete all as specified and directed.
S&F 150 mm size aluminium handles, cast type, anodised, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt 200mm legth of excluded section, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt 150mm legth of excluded section, complete all as specified and directed.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and as directed.
M&L for prepration of new or previously untreated wooden surface and applying two coats synthetic enamelled paint over a coat of pink primer of any descriptiion, not otherwise described over 10cm width or girth, complete all as specified and directed.
M&L for prepration of new or prreviously untreated steel surface and apply two coats synthetic enamelled paint over a coat of red oxide primer of any descriptiion, not otherwise described over 10cm width or girth, complete all as specified and directed.
M & L for water proofing treatment to sunken slab, walls, etc. shall be carried out as specified below and as directed by Engineer-in-Charge:- (a) Dismantling & remove the existing lean concrete completely and clean the sunken portion of toilet / Baths / WCs / Kitchen thoroughly remove laitance, dirt, dust etc. (b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor by using polymer modified mortar (“ Dr fixit” Pidicrete URP” or equivalent). (c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bathseal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bathseal Grout” or equivalent. Nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner. (d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bathseal Plus” or equivalent on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet and applying second coat of the same coating on the angle fillets and allow it to dry completely.
ITEM No. 22.00 Contd.... (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFI. Above FFI, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or equivalent to be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hoours and allow to dry completely. (f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M 15 type B0 mixed with integral WPC (Liquid) laid to stope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2. (g) After completing plumbing work in the toilet/WC/Bath/Kitchen, floor, tiling work (floor and dado) to be carried out by using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc. (Note : Lean concrete 1:5:10 type E-2 shall be measured and paid separately under respective item of BOQ.)
M&L for PCC 1:5:10 type E-2 using 40 mm graded brick aggregate as in filling sunken portion, complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded brick aggregate) as in coving rounded, chamfered etc on sunken floor, complete all as specified and directed.
Dismanling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to MES store yard and rubbish off the premises, complete all as specified and directed.
Dismantling of stone sett paving / PCC tiles or interlocking tiles of any description or thickness, laid bedded and pointed in any mortar, complete all as specified and directed.
M&L for vitrified ceramic tiles 8-10mm thick colour of size 600x600mm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and as directed.
All as per item No. 27.00 above but as in skirting over 10mm thick backcoat in CM 1:4, complete all as specified and as directed.
M & L for non skid joint free ceramic coloured (dark shade) tiles or size 300mm x 300mm x 7 to 8mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and as directed.
M & L for glazed colour ceramic tiles of size 300mm x 600mm x 7 to 8mm thick as in wall laid over and including 10 mm thick CM (1:4) backing coat, set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles, complete all as specified and directed by Engineer-in-Charge.
M & L for granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, Door cills ,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling of old stone slabs and tiles of any description or thickness
Rounding to edges of stone slab one edge, such as in steps, cooking platform and other similar situations
M&L for machine cut cuddappa stone 20 to 22 mm thick both side polished bedded & jointed in CM (1 : 3) including dismantling of old unserviceable stone slabs and tiles of any description or thickness, complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exc. 15 cm thickness (below or above GL), complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base 50mm thick including demolition complete all as specified and as directed
M&L for chequered cement concrete tiles 20cm x 20cm x 20mm thick set jointed and pointed in neat cement slurry in floor with grey cement and pigment over and incl 20mm thick screed bed in CM (1:4), complete all as specified and as directed.
M&L for coloured precast cement concrete interlocking paver block of glossy finish any shape and size confirming to IS-15658-2006, 60mm thick, M-35 grade with grey cement and no pigment laid over & including 30mm thick stone dust/grit, complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping / coving including weathering and throating including necessary form work etc., complete all as specified and directed.
Taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:6) on faire faces of brick / concrete surfaces finished even & smoth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick / concrete surfaces finished even & smoth without using extra cement , complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar, facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete complete all as specified & directed.
M&L for applying two coats cement base paint (snowcem) over a coat of primer on new walls surfaces, including preparation of surface of walls, complete all as specified and directed.
M&L for two coats of oil bound distemper on new surfaces of walls inlcuding preparation of surfaces of walls, complete all as specified and directed.
M & L for 15 mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down steel tubing and connections, complete all as specified and directed.
M & L for 20 mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down steel tubing and connections, complete all as specified and directed.
M & L for 25 mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down steel tubing and connections, complete all as specified and directed.
Cutting chases, pinning in brick / concrete block / stone walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting n. exc. 10 cm girth, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with & including 20 mm ball valve high pressure PTMT with rod & high density plastic ball including dismantling water tanks and removing to store complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tank 1000 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with & including 20 mm ball valve high pressure PTMT with rod & high density plastic ball including dismantling water tanks and removing to store complete all as specified and directed by Engineer-in-Charge.
Disconneting existing tank of capacity not exceeding 1000 litrs, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting and refixing in position etc, complete all as specified and directed.
M & L for water proofing treatment to roof slab, wall, chajjas etc; shall be carried out as specified below including removing of old existing water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust foregin material including flushing at junction of walll and removing the rubbish off the premises to a distance exc 500 m complete all as specified and directed by Engr-in-Charge :- (a) M & L for 10mm thick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) M&L for preparing plastered surfaces of roof slab, walls, chajjas etc; by proofing with broom sweeping free from dust etc; evently applying a coat of approved bitumenous primer @ 0.20 Kg/Sqm on all surfaces.
(c) M&L for laying APP polymer modified approved membrane, non woven, polyster, weighing not less than 3.50 Kg/Sqm with laps & overlaps as per manufacturer's instructions or as specified & joints sealed and applied complete by torch application method all as speciifed & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for to check the leakage & seepage and rectifying the same to the entire statisfaction of Engr-in-charge. (d) Finally applying a coat of solar reflective bitumenous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as speicifed & as directed by Engr-in-Charge.
S&F in repairs, stainless steel plate rack of size 36inch x 31inch x 10inch, made out of 0.63mm thick stainless steel sheet (Grade AISI 304 18/8), S S screws and round pipe, fixed to wall with screws complete all as specified and as directed. (Make – Blue Star Silver Shine Cat No.KPR-315 or equivalent from Nirali/ Jain Brothers Sanitation Pvt Ltd (Jayna) as approved)
S&F in repair 10mm thick corner glass with D bracket, complete all as specified and directed.
S&F high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm2 fixed complete to wall or in under floors with necessary socket, elbo & bend etc., complete all as specified and directed.
S&F in repairs 10 Itrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle. aluminium brackets for bottom support fixing with gutties embeded in wall with drilling machine etc, complete all as specified and directed.
S&F in repair brass CP wall mixer Non-telephonic shower arrangement screwed down for iron pipe of bore 15mm, complete all as specified and directed.
S&F in repair 15mm bore CP bib taps, brass chromium plated, cast copper alloy fancy type handle, screwed down, screwed for iron pipes, complete all as specified and directed.
S&F in repair brass chromium plated health faucet with 8mm dia, 1.2mtr flexible CP pipe, complete all as specified and directed.
S&F in repair brass CP towel ring, complete all as specified and directed.
S&F in repairs 20mm bore ‘D’ type brass CP tubular towel rail 60 cm long between flanges, complete all as specified and directed.
S&F in repair CP pressure adjustable shower with revolving joint, complete all as specified and directed.
S&F in repairs stainless steel soap dish, chromium plated, complete all as specified and directed.
S & F in repair stop valve, fancy type, 15mm bore brass chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F stainless steel grating 75 to 100 mm dia suitable for nahani trap, complete all as specified and directed.
S&F in repairs PVC (SWR) 110mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall, complete all as specified and directed.
S&F in repairs PVC (SWR) 75mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75 mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore provided with access door, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75 mm bore with access door, complete all as specified and directed.
S&F PVC (SWR) junction, (Single Tee) equal or unequal 110mm bore, complete all as specified and directed.
S&F PVC (SWR) junction, (Single Tee) equal or unequal 75mm bore, complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore, complete all as specified and directed.
S&F PVC (SWR), 75mm dia outlet floor trap, plain with grating including jointing with solvent cement, fixed to cement concrete type B1 1:2:4, complete all as specified and directed.
Taking down shutters not exc. 1.00 sqm by cutting though arc welding / chieseling and making good the disturbed surface by rubbing / painting, complete all as specified and directed.
S&F three track sliding window with two or more shutter witth 4 mm thick tinted glass , one shutter of stainless steel wire cloth 0.36 mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing, handle lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge. (a) Bottom frame 20620 (b) Top frame & Verrtical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & Bottom 20844 (f) Glazing Clip 19352
S&F aluminium powder coated two track sliding window with two shutters of 4mm thick frosted/figured glass of modigaurd including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and directed by Engr-in-charge with following sections of 'JINDAL' or of equivalent make :- Two track bottom – 20957, two track top / vertical – 20958, Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
S&F aluminium powder coated ventilator with moveable louvers including 100mm wide pinheaded glass strip using following sections of `Jindal Aluminum Ltd ' or equivalent in Ajit India Pvt Ltd or Crystal Bombay, as approved all as directed by Engineer-in-Charge (a) Frame - 20048 (b) Glazing clip - 19352
S&F ventiltors / louvers with partially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc, complete all as specified and as directed. (a) SP 20048 (b) Glazing clips 19352
S&F sheet glass ordinary quality, 3mm thick and glazing with oil putty in square n.exc. 0.50 sqm in each pane including hacking out old broken glass (any thickness, size , quality or description) from metal frames , glazed with putty or fixed with beads complete all as specified and directed by Engineer- in-charge.
S&F in repairs pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, 550x 400mm flat back including providing CI brackets, PVC waste pipe 32mm dia, waste coupling 32mm bore of brass CP etc, complete all as specified and directed.
S&F in repairs vitreous china, squatting pan, 'Orissa' pattern, size 580 x 440mm white, with integral foot rest, including concrete bedding including PVC flushing cistern 10 Ltr capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan, 'Pedestal' coloured, including fixing bolts etc including PVC seat cover white with flat bottom including MS, CP or aluminium anodised hinges devices including PVC low level flushing cistern 10 Ltr capacity with all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S&F in repairs stainless steel sink 1.00 thick for kitchen or laboratory with plug waste pipe washers including cantilivers cast iron brackets connecting union etc over all size 495mmx420mm with bowl size 410mmx330mmx160mm, complete all as specified and directed.
M&L for Gypsum ceiling board for ceiling prepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light etc, including taking down boarding / ceiling of any description, fixed in any position etc with nails, complete all as specified and directed.
Taking down aluminium point wiring( light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants holder,regulators sockets, light fitting etc removing materials deposited to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.as per engr-in-charge.
Taking down MCB DB / Main switch, old unserviceable / worn out aluminium sub main of any type and size complete all as specified and as directed.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 1.5 Sq.mm (Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked in and including heavy duty,PVC casing caping including all accessories etc.,heavy duty ISI marked,mild steel concealed sunken boxes,1.6 mm thick and 60 mm depth with earth dolly duly painted with two coat of black bituminious paint over a coat of red oxide primer with laminated bakelite sheet of min. thickness of 3mm suitable for switches/ sockets, etc, including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for the following:- (Note:- Making good of disturbed surfaces will be done by contractor without any claims.)
One light/fan/ point controlled by one switch.
One 5 Amps Socket outlet point controlled by one switch on independent board.
One 5 amps socket outlet point on same board with other switches
One bell/buzer point controlled by one bell push
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 2.5 Sq.mm(Nominal area),single core,,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked in and including heavy duty,PVC casing caping including all accessories etc.,heavy duty ISI marked,with mild steel concealed sunken boxes 1.6 mm thick & 60 mm depth with earth dolly duly painted with two coats of anti corrosive paint over of red oxide primer, internally, covered with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches, including PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core green PVC insulated cable as earth and connecting to earth dolly for 15 amps socket outlet point on independent board complete and including cutting and chases in the wall for box complete all as specified and as directed. (Note :- Making good of disturbed surfaces will be done by contractor without any claims.)
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 1.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked in the existing conduit ,with mild steel concealed sunken boxes with earth dolly with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches,sockets,etc including PVC insulated stranded copper conductor 1.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for the following:- (Note :- Making good of disturbed surfaces will be done by contractor without any claims)
One light/fan point controlled by one switch.
One 5 Amps Socket outlet point controlled by one switch on independent board.
One 5 amps socket outlet point on same board with other switches
One bell/buzer point controlled by one bell push.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 2.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade,ISI - 694 marked the existing conduit ,with mild steel concealed sunken boxes 1.6 mm thick & 60 mm depth with earth dolly duly painted with two coat of black bituminious paint over a coat red oxid primer with laminated bakelite sheet of min. thickness of 3mm sheet suitable for switches, including PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core green PVC insulated FRLS cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for 15 Amps socket outlet on independent board complete all as specified and as directed. (Note :- Making good of disturbed surfaces will be done by contractor without any claims)
M & L for submain wiring complete with two single core 4 Sqmm PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in existing conduit, including continuous PVC insulated copper earth wire 4 Sqmm including making good of disturbed surfaces with existing complete all as directed. (Note :- 3 runs of 4 Sqmm conductor and earth wire shall be measured as one unit length.)
M & L for submain wiring complete with two single core 6 Sqmm PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in existing conduit, including continuous PVC insulated copper earth wire 6 Sqmm including making good of disturbed surfaces with existing complete all as specified and as directed. (Note :- 3 runs of 6 Sqmm conductor and one run of 4 Sqmm earth wire shall be measured as one unit length.)
M & L for submain wiring complete with two single core 10 Sqmm PVC insulated, unsheathed multi stranded copper conductor FRLS cable, 1100 volts, FR grade in existing conduit, including continuous PVC insulated copper earth wire 10 Sqmm including making good of disturbed surfaces with existing complete all as directed. (Note :- 3 runs of 10 Sqmm conductor and one run of 6 Sqmm earth wire shall be measured as one unit length)
M&L for point wiring with 1.5 sqmm PVC insulated copper conductor FRLS cable 1100 Volts grade complete with & including PVC casing and caping and accessories with PVC ISI marked switch board, mounted on surface of walls including continuous PVC insulated copper earth wire 1.5 Sqmm connected to common earth dolly, for the following :-
One light/fan/ point controlled by one switch.
One 5 Amps Socket outlet point controlled by one switch on independent board.
One 5 amps socket outlet point on same board with other switches
One bell/buzer point controlled by one bell push
M & L for point wiring with 2.5 Sqmm copper conductor FRLS cable for 15 amps socket outlet point on independent board and continuous PVC insulated copper earth wire 1.5 Sqmm in PVC casing and capping and including PVC mounted switch board complete all as specified and as directed.
M&L for point wiring of any length using approved colour coding as per IS,with stranded copper conductor 1.5 Sq.mm(Nominal area),single core,PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/ fittings/ junction boxes/inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made pressed steel housing, totally concealed in walls suitable for modular switch socket accessories with earth dolly with suitable modular plate etc, including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for the following:- (Note :- Making good of disturbed surfaces will be done by contractor without any claims.)
One light/fan/ point controlled by one switch.
One 5 Amps Socket outlet point controlled by one switch on independent board.
One 5 amps socket outlet point on same board with other switches
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 2.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked in and including heavy duty, PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/ floors/ ceiling including all conduit accessories/ fittings/ junction boxes/inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made pressed steel housing, totally concealed in walls suitable for modular switch socket accessories with earth dolly with suitable modular plate etc, painted with two coats of anti corrosive paint over of red oxide primer, internally,covered PVC insulated stranded copper conductor 2.5 Sq.mm (nominal area) single core cable as earth and connecting to earth dolly complete and including cutting and chases in the wall for box and all as specified for 15 amps socket outlet point on independent board (Note :- Making good of disturbed surfaces will be done by contractor without any claims)
S&F modular type switch 6A single pole,one way,240 volts, Cat.No 6730 00 Make-Legrand "Myrius series" or of equivalent specified here-in-after complete all as specified and as directed.
S&F multipurpose socket outlet 16A -2/3 pin,2 module for 230 volts flush type.cat.No 6730 42 Make-Legrand "Myrius series" or of equivalent specified here-in-after complete all as specified and as directed.
S&F modular type switch 16A single pole,one way,1 module, 240 volts,Cat.No 6730 00 Make-Legrand "Myrius series" or of equivalent specified here-in-after complete all as specified and as directed.
S&F modular universal socket 2 module outlet 6 amps 5 pin 230 volts flush type complete all as specified and as directed. (Make-Legrand : "Myrius series" or of equivalent specified here-in-after.)
S&F in replacement of modular ceiling fan step regulator 100W,2module, electronic step type, suitable for fan 48"/56" sweep complete all as specified and as directed. (Make-Legrand,"Myrius series" or of equivalent specified here-in-after)
S & F 240 V, 20 Amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
S&F piano type switch 5 amps single pole,240 volts complete all as specified and as directed.
S&F bell push, flush type, 5 amp, 240 volts complete all as specified and as directed.
S&F bell electrical ding dong including hard\wood board bell push, flush type, 5 amp, 240 volts complete all as specified and as directed.
S&F ceiling rose surface type three terminals,240 volts complete all as specified and as directed.
S&F socket outlet 5 amps 5 pin 230 volts flush type on same board complete all as specified and as directed.
S&F socket outlet multipurpose 2 in 1, 5/15 amps, 230 volts flush type complete all as specified and as directed.
S&F piano type switch 15 amps single pole, 240 volts complete all as specified and as directed.
S&F lamp holder (Angle/bracket) insulated body, with back plate for batten fittings with 5 watt LED bulb etc. complete all as specified and as directed.
S&F in replacement of ceiling fan regulator two module, electronic step type, delux, suitable for fan 48"/56" sweep complete all as specified and as directed.
S&F bell push, flush type, 5 amp, 240 volts, Modular type complete all as specified and as directed.
M & L for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC casing caping and making good of disturbed surfaces with existing complete all as directed by Engineer-in-Charge. (Note :- 3 runs of 4 Sqmm conductor and earth wire shall be measured as one unit length.)
M & L for Sub main wiring complete with two single core 6 sqmm ,1100volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 6 sqmm in and including PVC casing caping and making good of disturbed surfaces with existing complete all as directed. (Note :- 3 runs of 6 Sqmm conductor and earth wire shall be measured as one unit length.)
M & L for Sub main wiring complete with four single core 6 sqmm ,1100volts grade, PVC insulated, stranded copper conductor FRLS cable with two continuous copper earth conductor of 4 sqmm in and including PVC casing caping complete all as directed by Engineer-in-Charge. (Note :- 6 runs of 6 Sqmm conductor and earth wire shall be measured as one unit length.)
M & L for Sub main wiring complete with two single core 6 sqmm ,1100volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 6 sqmm in and including PVC conduit for consealed complete all as directed by Engineer-in-Charge. (Note :- 3 runs of 6 Sqmm conductor and earth wire shall be measured as one unit length.)
M & L for Sub main wiring complete with four single core 6 sqmm and two core of 6.0 sq.mm earth wire,1100volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor in and including PVC conduit for concealed and making good of disturbed surfaces with existing complete all as specified and as directed. (Note :- 6 runs of 6 Sqmm conductor and earth wire shall be measured as one unit length.)
M&L for cutting chases, pinning in making good to facing where required and poinitng in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good of disturbed surfaces, cutting not exc 10 cm girth all as specified and directed by engineer in charge. (Note : Making good of disturbed surfaces will be done by the contractor without any claims.)
S&F MCB DB TPN 4 way double door with 200 amps rated busbar 415 V, recess mounted/wall mounted all as directed and specified by Engineer in charge.
S&F MCB DB SPN 8 way, double door, with 200 Amp rated busbar 240 V, recess mounted all as specified and directed by Engineer in charge.
S&F vertical 4 way TPN double door,recess mounted / wall mounted DB incl one number,MCCB as incomer 3 pole and neutral of 100A rated capacity & 16KA breaking capacity,pre-fitted at factory all as specified and directed.
S&F MCB DB SPN 4 way double door with 200 amp rated busbar, 240V recess mounted with common earth dolly all as directed and specified.
S&F MCB SP 6-32amps,10KA,'C' series complete all as specified and as directed.
S&F MCB SPN 40-63 amps,10KA, 240V,'C' series complete all as specified and as directed.
S&F MCB TPN 63 amps ,10KA,415 V,'C' series complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bars at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earthwire and GI protection pipe upto 7.5 mtr length shall be included in this item.)
M & L For fixing earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 4 sqmm GI Wire complete all as specified and as directed.
Supplying and fixing LED tube light fitting complete with all fitting and fixing accessories, 1X20 Watt pre-wired with high efficiency electronic driver, glarefree, smooth light distribution complete all as specified and as directed.
Supply and fixing Integral LED Security Light Luminaire 30 W comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe (including GI pipe) complete with accessories conforming to Cat Part No : HPLLEDSL3060S of HPL or of equivalent in Wipro/phillips/Havells/Fortune Art all as specified here-in-after including taking down old fitting.
Preventive maintenance of storage type electric water heater (Geyser) of capacity 25/50 ltrs comprising of the following tasks at different locations of any make: (a) Inspection of geyser after opening bottom cover plate. (b) Examine water tightness of storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands of defective taps to ensure water tightness smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats and test its functioning. (h) Checking and adjustments of pressure reducing valves. (i) Checking of dead weight type high pressure release valve (PRV) by removing dead weight protection cleaning the seat and ensuring that the waste hole is not blocked / chocked. (j) Testing of Geysers after repairs/maintenance in all respect for proper functioning. (Note : Spares shall be measured and paid seperately)
Supply & fix thermostat ISI marked suitable for the following capacity Geysers 25 ltrs. to 50 ltrs capacity complete all as specified and as directed.
Supply & fix safety valve/dead weight valve ISI marked suitable for 25 and 50 ltrs. capacity Geysers complete all as specified and as directed.
Supply & fix heating element for 1KW /1.5 KW rating as required at site(any type) including rubber washers (ISI marked) complete all as specified and as directed.
Supply & fix storage inner tank made out of copper sheet suitable for following capacity geysers complete all as specified and as directed :-
Supply & fix apparatus plate for Geyser of 25 to 50 ltrs. Capacity complete all as specified and as directed.
Supply & fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 45/60cm long for cold water as per requirement complete all as specified and as directed.
All as per Ser. Item No. 157.00 above but for hot water complete all as specified and as directed.
Supply & fix For unserviceable15A plug top and connection complete all as specified and as directed.
Supply & fix non-return valve 15mm / 20mm dia of brass ISI marked complete all as specified and as directed.
S&F in repairs to Geysers inner water tank of 25 to 50 ltrs. capacity in gas welding / brazing for water tightness and testing complete all as specified and as directed.
Supply & fix indicators of Geysers 25 to 50 ltrs. Capacity(Red/Green/Yellow) complete all as specified and as directed.
Supply & fix gasket rubber ring for Heater plate of any size Geysers complete all as specified and as directed.
Supply & fix inspection cover for outer container of Geysers 25 to 50 ltrs complete all as specified and as directed.
Supply & fix outer container made out of 14 gauge CRCA sheet duly painted for the following :-
Suitable for 25 ltrs. capacity
Suitable for 50 ltrs. capacity
Taking down defective geysers for repair/ painting/ shifting complete all as specified and as directed. (Note :- Repairs will be measured and paid separately under respective Item of Sch)
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket/switch to geyser complete all as specified and as directed.
S&F in repairs cable PVC insulated 3 core 4.0 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed.
S&F PVC rectangular block for mounting, switches, sockets,fan regulator etc with cover laminated sheet cover of size 100mmx100mm and 50mm deep complete all as specified and as directed. (Note :- Making good of disturbed surfaces will be done by contractor without any claims)
All as per Ser. Item No. 158.00 above but 175x100x50 mm deep complete all as specified and as directed.
All as per Ser. Item No. 158.00 above but 200x150x50 mm deep complete all as specified and as directed.
All as per Ser. Item No. 158.00 above but 250x200x50 mm deep complete all as specified and as directed.
All as per Ser. Item No. 158.00 above but 350x300x50 mm deep complete all as specified and as directed.
S&F Fan condenser 2.5Mfd, 230V AC,50 Hz complete all as specified and as directed.
Gauri Associates
TAKSHASHILA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .