Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹10.4 L+₹67,717.40 (6.97%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Higher amount quoted | |
| 3 | L3₹11.9 L+₹2.2 L (22.4%)Rejected-Finance | L3 | Rejected-Finance Higher amount quoted | |
| 4 | L4₹11.9 L+₹2.2 L (22.4%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L4 | Rejected-Finance Higher amount quoted |
Tender Value
Refer Docs
EMD Value
₹28,720
Closing Date
10 Mar 2021, 6:00 pmClosed
CWE (A) Jaisalmer
CWE (A) Jaisalmer
REPAIR and MAINT OF SUMMER APPLIANCES, STREET LIGHTS, DG SETS AND MISC WK IN CERTAIN AREA UNDER AGE (I) POKARAN
2021_MES_420583_1
83926
Open Tender
Electrical and Maintenance Works
Works
180 days
Pokaran under AGE (I) Pokaran
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (A) Jaisalmer
₹28,720
Yes
23 Apr 2021
10 Feb 2021
12 Mar 2021
10 Feb 2021
10 Mar 2021
24 Feb 2021
Amount
M&L for cleaning down complete body including fitting and fixture of desert cooler of air flowing capacity 4000/5000 Cum/per hour of any make with wire including removal of all sludges, loose paints, dust, dirt etc and prepared the surface clean for painting and applying two coats of rubber based paint inside the water tank complete, including rewriting of MES No. complete all as specified & directed by Engr-in -charge.
S&F in repair, fan motor of single phase 230 Volt, 1400 RPM 3 speed 1/8 HP for desert cooler incl cast iron rings for motor with clamps nuts & bolts complete all as specified & directed by Engr-in -charge. MAKE : COOL HOME/ KHAITAN/ POLAR/CG
"-do- all as item No 2 above but fan motor 24" sweep 900RPM
S&F in repair, front grill/louvers of desert cooler made out of 0.8 mm thick GI sheet of air flowing capacity 4000/5000 Cum/Per hour of any make complete all as specified & directed by Engr-in -charge.
S&F in repair, PVC flexible pipe of 16 mm outer dia complete with PVC elbow, tee as required complete all as specified & directed by Engr-in -charge.
S&F in repair,wood wool pad (set of three) minimum weight 0.8 Kg, proper fixed in 3 side of panels of desert cooler complete all as specified & directed by Engr-in -charge.
S&F in repair,plug top 3 pin 5 Amp with cable upto 2mtr, 230 Volt (ISI marked) complete all as specifide & directed by Engr-in -charge.
S&F in repair,PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including making necessary connections for desert coolers complete all as specifide & directed by Engr-in -charge.
S&F in repair,capacitor 4 Mfd for fan motor of desert cooler complete all as specifide & directed by Engr-in -charge.
S&F in repair, water spray pump 1/30 HP for desert cooler . MAKE : COOL HOME/ KHAITAN/ POLAR/CG
S&F in repair, side/back shutter made out of 0.80 mm thick galvanised iron sheet of size suitable for desert cooler of air delivery capacity 4000/5000 Cum/per hour complete all as specifide & directed by Engr-in -charge.
S&F in repair, iron fan blade aluminium coated for fan motor of desert cooler of 20 inch sweep complete all as specifide & directed by Engr-in -charge.
S&F in repair, PVC 3 way distributor suitable for 15 mm flexible pipe with nuts & screws for desert cooler complete all as specifide & directed by Engr-in -charge.
S&F in repair, cap 4000/5000cum per hour of desert cooler bottom tank , fabricated out of 1 mm thick mild steel galvanized iron sheet including gas welding at joints and testing for water tightness and applying one coat of synthetic enamel paint outside & one coat of rubber based paint inside complete all as specifide & directed by Engr-in -charge.
S&F in repair, submerssible cooler pump suitable for central air cooling /desert cooler all as specified and directed by Engr In charge
M&L for ply wood 6.0mm thick, cutting to suitable size for existing window and making opening in required size at plywood for passing/flow the air inside the room incl removing old ply wood all as specified and directed by engr in Charge
S&F PCB kit control card suitable for 50/75 KVA voltage stabilizer incl removing old unsv PCB kit all as specified and directed by Engr In Charge
Repair to single phase voltage stabilizer of following capacity rewinding of transformer , replacement of new wiring with relays, switches & suitable voltmeter including testing and commissioning all as per direction of Engr in Charge
a) 5.0 KVA capacity
b) 3.0/2.0 KVA capacity
S&F in repair, galvanised iron bracket of light grade pipe 40/50mm bore length 1.20m bend to reqd shape with 2 Nos clamps made out of 40x6mm FI and suitable size of bolts nuts & washers etc complete for fixing street light fittings all as specified and directed by Engineer in charge Note : the quoted rate shall also include one primer coat of Al. paint on FI clamps after preparation of surfaces incl removing old unsv bracket complete all as specified and directed
-Do- all as per items above but 25mm bore
Supply and fix in repair 4 mm 2 core, 240volts Al. conductor cable heavy duty PVC insulated ISI marked all as specified and directed by Engr In charge.
S & F in repair LED street light fitting 1x30 watt with pressure die cast aluminium housing,heat resistant toughened glass with fram, duly prewired inbuilt LED module IP 66 Protection complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts with PVC 20mm conduit for cable including clamps etc complete all as specified and directed Make: Crompton Greaves Cat part no LSTO-45-CDL or Equivalent make of Havells/Philips/Bajaj/Wipro.
S & F LED building Security light fitting 1x18 watt with Sleek pressure die cast aluminum housing duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed Make: Crompton Greaves Cat part no LSTS-18-CDL or Equivalent make of Havells/Philips/Bajaj/Wipro.
S & F repair, maintanance free battery led acid type 180 AH suitable for 160/100 KVA DG Set complete all as specified & directed by engineer in charge
Supply and fixing decorative Post-top LED ,IP-65 protection,Resistant to impact and corrosion glare free and better free uniformity luminaire 40 watts incl provn of three core cable size 1.5 Sq.mm switch to fitting with all accessories and all as specified and directed by Engineerin Charge Make- Crompton greaves Limited LPTO-40-CDL/M or Equivalent make of Havells/Philips/Bajaj/Wipro.
M&L for repair to LED street light fitting incl replacement of unsv items like LED drivers any size of watt, fuse, Wire and taking down LED street light, nut bolt, clamp and fixing etc as per direction of Engr in Charge Make- Crompton greaves Limited S0DQL1-54-700-45W or Equivalent make of Havells/Philips./Bajaj
S&F of GI tubing light grade of size 40/50mm for protection of cable in trenches/on pole all as directed by Engr-in-charge.
Taking down old unserviceable LT cable, supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, all as specified directed by Engineer In charge of cross sectional area and core of following sizes:-
(a) Size of cable 16 Sq.mm 4 Core
(b) Size of cable 10 Sq.mm 2 Core
Note : Excavation and earth work , sand, pipe and stone patti will be measured and paid separately
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for soft / loose soil.
Removing excavated material any type n exc 50m and depositing at a level n.exc 1.5M above ground.
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil.
M&L for sand cushioning to PVC cable with tibba sand and punning to provide required cover all as directed.
Supply and laying Jodhpur stone patti for cable protection of lenth between 55 to 60 cm but width between 25 to 30 cm thicknes not less than 5 cm complete as per site requirement incl removing old unsv patti and direction of engineer in charge.
S&F PVC conduit pipe size of 15mm bore 5m long, for protection of cable fixed on pole with 2 Nos clamps made out of 40x6mm FI and suitable size of bolts, nuts and washers etc complete all as specified & directed by Engineer-in-charge.
M & L minor overhauling of DG set of following capacity including cleaning of rediator, replacing the coolant, replacement of filter elements complete sets, cleaning of air filters, replacing of engine oil, replacement of rubber hose pipes, replacement of oil seals, geasing the movable part & bty terminal etc all as per annul maintenance chart as recommended by the manufacturing and testing up to satisfaction complete as directed by Engineer in charge.
Note : Spare part / materials other than coolants and engine oil are deemed to be included in the above quoted rate.
S&F controller relay system of 160 KVA DG set as per exisiting system recommended by the manufacturing and testing up to satisfaction complete as directed by Engineer in charge.
S&F controller relay system of 63/100 KVA DG set as per exisiting system recommended by the manufacturing and testing up to satisfaction complete as directed by Engineer in charge.
S&F door gasket for water cooler cap 40/80 lit per hour complete all as specifide & directed by Engr-in -charge.
M&L for preparation of complete old painted surface of 40/80 litres capacity water cooler, externally, internally including compressor chamber, compressor motor etc and applying one coat of synthetic enamel paint with spray machine including rewritting of MES No. complete all as specifide & directed by Engr-in -charge.
Supply and replace condenser cooling fan motor with fan blade of cap 1/30 HP suitable for water cooler of cap 80/40, 100 ltrs. Make - AUE
S&F in repair, flot valve high pressure of PTMT body with epoxy coated Aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 142 grams/each, fixed to water cooler complete all as specifide & directed by Engr-in -charge.
S&F in repair, 15 mm bore water tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, starting capacitor 80-100 MFD suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, running capacitor 40-60 MFD suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, thermostate suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 liters complete all as specifide & directed by Engr-in -charge.
S&F in repair, relay with over load protection suitable for 40 to 150 liters capacity water cooler complete all as specifide & directed by Engr-in -charge.
S&F in repair, PVC drain out pipe, heavy duty 32/40 mm dia, wall thickness 2 mm having length not less than 1.0 mtr complete with fitting such as nipple, clips etc complete fixed to water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
M&L for 15 mm bore mild steel galvanized water tubing, medium grade with all fitting and accessories complete fixed to wall and celling or laid in floors including taking down old unserviceable GI tubing complete all as specifide & directed by Engr-in -charge.
Removing the unserviceable compressor sealed unit of any make from water cooler of capacity 40/80 liters after cutting copper tubing without any damage to exisiting parts, replacing compressor with new compressor of same make refixing of compressor on bace & jointing of copper refrigerant pipe line filter etc & charging gas to required level, including cleaning of fins, leakage testing etc including testing & commissioning for smooth functioning complete all as specifide & directed by Engr-in -charge.
S&F in repair, condensing coil suitable for water cooler of capacity 40/80 liters complete all as specifide & directed by Engr-in -charge.
M & L for flushing,pressurising the system , leakage testing vacuumisation and GAS CHARGING with refrigerant gas (R-134) at apprporiate pressure including testing at site for water cooler of cap 80/40 ltrs.
S&F door gasket for refrigerator 165/175/286/310 lit cap complete all as specifide & directed by Engr-in -charge.
M&L for cutting and removing uncervicable freezer unit of refrigerator of capacity 165 to 210 liters of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specifide & directed by Engr-in -charge.
M&L for cutting and removing uncervicable freezer unit of refrigerator of capacity 286 to 310 liters of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specifide & directed by Engr-in -charge.
M&L for preparation of external old painted surface of refrigerator of capacity165 to 310 liters of any make, including making good of denting etc and applying one coat of duco paint with spray machine including polishing complete all as specifide & directed by Engr-in -charge.
S&F in repair, thermostate suitable for refrigerator 165 to 310liters capacity complete all as specifide & directed by Engr-in -charge.
Removing the unserviceable compressor sealed unit of refrigerator of capacity 286/310 liters of any make, & replacing with new compressor of same make & model, rein-stalling in orignal position with all accessories like relay with over load protector, filter & recharging of refrigerant gas complete including testing & commissioning for smooth functioning complete all as specifide & directed by Engr-in -charge.
Removing the uncerviceable compressor sealed unit of refrigerator of capacity 165/175/195 liters of any make, & replacing with new compressor of same make & model, rein-stalling in orignal position with all accessories like relay with over load protector, filter & incl charging of refrigerant gas complete including testing & commissioning for smooth functioning complete all as specifide & directed by Engr-in -charge.
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site for refrigerator of cap 165/195 ltrs.
M & L for flushing,pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site for refrigerator of cap 285 / 310 ltrs.
S&F lamp with holder for refrigerator any capacity and any make incl removing old unsv lamp all as specified and directed by Engr In charge
Dismantling unserviceable compressor sealed unit of any make from deep freezer of cap 310 liter after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
M&L for removing the old burnt out condenser fan motor of Deep freezer of capacity 310/220 liters from position and replacing with new motor and reassembling and fixing in position complete all as specifide & directed by Engr-in -charge.
Dismantling unserviceable compressor sealed unit of any make from window type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
" -do- all as item No 46 above but 2.0 TR cap window type Air Conditioner
Supply and replace BLOWER FAN MOTOR 1/8 HP suitable for window type AC cap 1.5/2 ton
S&F running capacitor 45/50 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable running capacitor all as specified & directed by Engr In Charge
S&F starting capacitor 100-120 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable starting capacitor all as specified & directed by Engr In Charge
S&F Aluminium fan blade suitable for condensing side of window type AC 1.5/2.0 TR cap complete all as specified & directed by Engr In Charge
S&F PVC blower blade heavy duty suitable for evaporative side of window type Air conditioner 1.5/2.0 TR cap complete all as specified and directed by Engr in charge
S&F starting relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Cahrge
S&F over load protector relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Cahrge
S&F thermostat suitable for 1.5/2.0 TR cap window /Split type AC complete all as specified and directed by Engr In Charge
S&F air filter for split type AC 1.5 TR cap ( Set of three) complete all as specified & directed by Engr in Charge
Dismantling unserviceable compressor sealed unit of any make from external unit of Split type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
Supply and replace BLOWER FAN MOTOR 1/8 HP suitable for split type AC cap 1.5 ton
S&F in repair PVC flexible drain out pipe of Split type , heavy duty of 15/25mm dia and 1.5mm wall thickness complete with fittings , spacers and saddles etc complete all as specified & directed by Engr In Charge
S&F repair wireless remote control (Micro processor ) unit suitable for Split type AC any cap testing & complete all as specified and directed by Engr In Cahrge
Taking down for serviceing the cooling side blower motor of cap 1/30 HP to 1/20 HP from split type AC & M&L for new motor and refixing of motor in original position with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge
S&F PCB circuit of existing size & shape to split type AC having cap 1.5 TR complete all as specified & directed by Engr In Charge
M&L for servicing of Split /window type AC of Cap 1.5TR/2.0 TR of any make by opening the conderser unit fixed on roof top & cooling unit fixed inside the building, cleaning the complete conderser unit & cooling unit incl fins &checking / testing of all parts for its serviceablity & oiling/greasing of motors , replacing the worn out bushes of blowers & rectfication of unuseal noises , checking of refrigerent standing pressure, topping up of refrigerant gas upto the reqd level, replacemnt of minor parts such as nuts bolts & washers etc & reassembling of complete unit incl testing & commissioning for smooth functioning complete all as specified & directed by engr in charge
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-22) at apprporiate pressure including testing at site for window/Split type AC cap 1.5 ton.
S&F single pole and neutral enclosure with metal clad plug & socket 20 Amps & with MCB SP 20 Amps complete all as specified and directed by Engr in Charge
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site of AC 7.5 TR capacity Package type AC complete all as specifide & directed by Engr-in -charge.
S&F in replacement of condenser fan/blower motor from Package type Air conditioner of 7.5 TR cap with new motor and refixing of motor in original position with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge
S&F in repair fully automatic star delta starter (EASD) type for compressor motor having inbuilt single phase preventor, no volt and under volt protection over load peotection. Reverse phasing protection of suitable capacity for AC 7.5 TR as recommended by manufacturer as per the load of the compressor motor all as specified and directed by Engr-in-charge.
S&F PCB circuit of existing size & shape to Package type AC having cap 7.5 TR complete all as specified & directed by Engr In Charge
S S enterprises
star electricals
vijay enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .