Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.6 L+₹2.2 L (11.6%)Rejected-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹23.1 L+₹3.8 L (19.5%)Rejected-AOC OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹23.6 L+₹4.3 L (22.2%)Rejected-AOC DUDH LINE NAYAGAON VILL SHADIPUR POST SRI VIJAYA PURAM TEHSIL SOUTH ANDAMAN 744106 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744106 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹24.5 L+₹5.1 L (26.6%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 Dec 2021, 6:00 pmClosed
GE Brichgunj
GE Brichgunj, Port Blair
REPAIR AND MAINTENANACE OF EXTERNAL WATER SUPPLY AND CLEANING OF SERVICE TANKS UNDER GE BRICHGUNJ, PORTBLAIR
2021_MES_490089_1
GE8173A
Open Tender
Civil Works
Item Rate
270 days
GE Brichgunj
As per tender documents
8 documents required · 8 mandatory
₹500
GE Brichgunj
₹40,000
Yes
14 Jan 2022
24 Nov 2021
17 Dec 2021
24 Nov 2021
15 Dec 2021
8 Dec 2021
24 Nov 2021 - 7 Dec 2021
Amount
M&L for Cleaning of overhead reservoir upto 30 mtr staging, semi UG Sumps, Sumps, reservoirs, storage tanks, Fountain with deployment of mechanical equipment such as high jet pumps for removal of dirty water vacuum operated pump for sludge removal, cleaning of inner wall, ceiling and bottom by high pressure rotary jet 120 bar pressure, wet vacuum cleaner etc. complete all as specified and as directed
The complete job of the tank cleaning process will be as under:- (i) Mechanical removal of all remaining dirty water by high capacity submersible pump set. (ii) Removal of Sludge by vacuum operated German pump. (iii) Cleaning of walls, ceiling and bottom of tank by German made high pressure rotary jet 120 bar pressure. (iv) Removal of all dirty particles by industrials wet vacuum cleaner leaving the tank physically cleaned. (v) Sterilization of tank by Eco friendly biodegradable and highly effective against all pathogenic agents.
Notes:- (i) Contractor must clean and disinfect the water storage tank within 24 hours after giving the site by Engr-in-Charge to avoid the disturbance of water supply to the connected area. (ii) In case of any accident during the work in progress the contractor will be fully responsible to give necessary medical aids and also compensation to worker under compensation act 1923. (iii) No extra payment will be made for transportation of any machineries required for cleaning and disinfection the storage tank. (iv) Item No 1.03 to 1.18 water tanks cleaned once in 6 months interval or if any water contamination occurs, as per directions of Engr-in-Charge. (v) Contractor must write the date of cleaning and capacity of tank at the wall of the storage tank in size of 2 ft x 2 ft base painted by synthetic enamel paint. Base should be in light blue colour and letters should be white colour without extra payment.
Semi Underground sump of capacity 2.65 lakh litres (STP treated water collection sump)
Semi Underground sump of capacity 4 lakh litres (MES OHT)
Underground sump of capacity 88000 litres(MES OHT)
Semi Underground sump of capacity 60000 gallons (Para 11)
Underground sump of capacity 15000 litres at fire fighting sump at Likabali
Storage tank 50000 ltrs capacity at Fire fighting sump at Likabali.
Ground level clarifloculator sump of capacity 4.5 lakh gallons including flush mixing chamber, RCC water channel at Prothrapur filtration plant
Suction Gallary of capacity 7000Gallon at Prothrapur filtration plant
Filter Bed of capacity 7000Gallon at Prothrapur filtration plant
Underground sump of capacity 400000 litres (RWH)
Underground sump of capacity 200000 litres (RWH)
Semi Underground sump of capacity 300000 litres (MAP Pumphouse)
Overhead tank of capacity 3 lakh litres (MAP OHT)
Overhead tank of capacity 2.25 lakh litres (MAP OHT)
SMFT tank of capacity 50000 Litres at RWH
SMFT tank of capacity 30000 Litres at 50 KLD
Collect the sample of water of 5 litres each from user end, after cleaning of UG Sumps or OH Tanks or RCC/ PVC tanks and sending it same day at Govt approved lab for testing of water as per IS 10500 in a cleaned container and necessary reports will be submitted to GE Birchgunj complete all as directed by Engr in Charge.
M&L for draining out complete water from existing PVC water tank fixed on the roof top of the buildings, removing the mud, sludge etc; from the tank, cleaning the internal surface using bleaching powder and wire brush, keeping it dry, painting the external surfaces of the tank facing the road side with black/white background of size 450mm x 300mm with one coat of approved black/white synthetic enamel paint, writing on the white/black surface with white/black paint " TANK CLEANED ON (date)" size of letter shall be 50mm x 70mm, checking and correcting the air lock on occurrence next day after the cleaning of the tank, when the tank is full of water, removing the same with pump, repair the leakage if any and cleaning the vegetation etc; on surrounding RCC slab where the tank is resting, complete all as specified and directed by Engineer-in-Charge for the following capacity: -
Note for Item No 3(a) to (d) - In case of any accident during the work in progress the contractor will be fully responsible to give necessary medical aids and also compensation to worker under compensation act 1923.
(a) Service tank of capacity not exceeding 250 litres
(b) Service tank of capacity exceeding 250 litres but not exceeding 500 litres
(c) Service tank of capacity exceeding 500 litres but not exceeding 1000 litres
(c) Service tank of capacity 2000 litres
(d) Service tank of capacity 5000 litres
S&F in replacement 20mm dia Ball Valves(float), high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc. complete all as specified and as directed
S&F in replacement 25mm dia Ball Valves(float), high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc. complete all as specified and as directed
S&F in replacement 40mm dia Ball Valves(float), high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc. complete all as specified and as directed
Supply and fix PVC tank cover (top) for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) suitable for 200/250/500/1000/2000 ltrs capacity, after taking out unserviceable PVC water tank cover complete all as directed by Engineer-in-Charge.
Supply and fix rotational moulded polyethylene three layer water storage tanks (cylindrical vertical with closed top) with tank cover (top) hoisted and fixed in position complete after dismantling and taking down the existing unserviceable PVC water tank of size 200/250 ltrs capacity from terrace complete all as directed by Engineer-in-Charge.
All as per item No 8 above but of size 500 ltrs capacity
All as per item No 8 above but of size 1000 ltrs capacity
All as per item No 8 above but of size 2000 ltrs capacity
Supply and fix in repairs FRP tank of 200 Litres capacity all as specified and as directed
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for taking out or laying of pipes / cable of any size in Soft/ loose soil complete all as specified and as directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
S&F in replacement of 20mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings of in floors etc complete all as specified and directed.
S&F in replacement of 25mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings of in floors etc complete all as specified and directed.
S&F in replacement of 40mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings of in floors etc complete all as specified and directed.
S&F in replacement of 50mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings of in floors etc complete all as specified and directed.
S&F in replacement of 80mm CPVC pipes of pressure rating 10Kgf/sqcm fixed SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc) as required at site on walls, ceilings of in floors etc complete all as specified and directed.
S&F in replacement for union socket/socket of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed Schedule 80 graded complete all as specified and directed
All as per item No 21 but of size 25mm bore
All as per item No 21 but of size 40mm bore
All as per item No 21 but of size 50mm bore
All as per item No 21 but of size 80mm bore
S&F in replacement for coupler of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 26 but of size 25mm bore
All as per item No 26 but of size 40mm bore
All as per item No 26 but of size 50mm bore
All as per item No 26 but of size 80mm bore
All as per item No 26 but of size 100mm bore
S&F in replacement for Tank connector Moulded of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed.
All as per item No 32 but of size 25mm bore
All as per item No 32 but of size 40mm bore
S&F in replacement for TEE of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 35 but of size 25mm bore
All as per item No 35 but of size 40mm bore
S&F in replacement for Reducer of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 38 but of size 25x20mm bore
All as per item No 38 but of size 40x25mm bore
All as per item No 38 but of size 50x40mm bore
S&F in replacement for Reducing Elbow of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 42 but of size 25x20mm bore
S&F in replacement for Elbow of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 44 but of size 25mm bore
All as per item No 44 but of size 40mm bore
All as per item No 44 but of size 50mm bore
All as per item No 44but of size 80mm bore
All as per item No 44 but of size 100mm bore
S&F in replacement for Reducing bush of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per item No 50 but of size 25x15mm bore
All as per item No 50 but of size 25x20mm bore
S&F in replacement for 20mm dia ball valves, Union Type, high pressure, CPVC polythene gate and flynut complete all as specified and as directed.
All as per item No 53 but of size 25mm bore
All as per item No 53 but of size 40mm bore
All as per item No 53 but of size 50mm bore
All as per item No 53 but of size 80mm bore
Supply only for CPVC Adhesive solution Gel type of Each 118ml Tin for jointing of UPVC Materials.
S&F in replacement for PP-R Gate valves (brass insert) as per requirement of the site of size 20mm
S&F in replacement for PP-R Gate valves (brass insert) as per requirement of the site of size 25mm
S&F in replacement for PP-R Gate valves (brass insert) as per requirement of the site of size 40mm
S&F in replacement for PP-R Gate valves (brass insert) as per requirement of the site of size 50mm
S&F in replacement for PP-R Tank connector long of size 20mm
S&F in replacement for PP-R Tank connector long of size 25mm
Supply only PP-R Cutter 20-40mm size
S&F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 20 mm all as specified and as directed by Engr-in-Charge.
All as per item No 66 above but of size 25 mm.
All as per item No 66 above but of size 40 mm.
All as per item No 66 above but of size 50 mm.
All as per item No 66 above but of size 80 mm.
All as per item No 66 above but of size 100 mm.
M&L for PCC 1:3:6 Type C1 (using 20mm graded aggregate) as in coping including necessary form work complete, all as specified and as directed by Engr-in-Charge.
Material and Labour for preparing old painted or untreated exposed surfaces of GI/ CI / DI Pipes of size 500/ 400 / 300 / 200mm bore, Valve Chamber Covers, clarifloculators, pump motors, railing, equipments in STP, RWH Plant etc and applying one coat of weather proof synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. Note: colour of weather proof paint shall be decided by the Engineer-in Charge as per site condition
S&F in repairs Anti syphon valve as per sample (upto 20mm size) for dosing pump of Make Milton Roy all as specified and as directed
S&F in repairs discharge valve as per sample (upto 20mm size) for dosing pump of Make Milton Roy all as specified and as directed
S&F in repairs suction valve as per sample (upto 20mm size) for dosing pump of Make Milton Roy all as specified and as directed
S&F in repairs ball ceramic as per sample (upto 20mm size) for dosing pump of Make Milton Roy all as specified and as directed
S&F in repairs foot valve as per sample (upto 20mm size) for dosing pump of Make Milton Roy all as specified and as directed
S&F replacement of dosing pipe line of maximum length 10 RM as per sample (upto 20mm size) for dozing pump all as specified and as directed
Supply only PH test Kit including all testing materials
Supply only Ortho Tolidine solution in 500ml bottle pack.
Supply Only Pocket PH Meter (Dual display), Range-0.00 to 14.0 PH, Accuracy +/- 0.1 PH
Supply Only Portable TDS Meter, Range-0 to 19990 PPM, Accuracy +/- 2% F.S
Supply and fix in replacement GI Plug of 25mm bore medium grade ISI marked.
Supply and fix in replacement GI Plug of 40mm bore medium grade ISI marked.
S&F in replacement of pressure gauge 0 to 10 Kg/ Sqcm in the pumping water line all as specified and as directed
Supply and fix in replacement 3 phase analog type ammeter in existing LT Panel
Supply and fix in replacement 3 phase analog type volt meter in existing LT Panel
Supply and fix in replacement indicating lamp (R,Y,B) in the existing LT Panel
Supply & fix MCCB 200A, 35 KA 3 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable.
Supply & fix MCCB 250A, 35 KA 3 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable
Supply & fix MCCB 200 A, 35 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable.
Supply & fix MCCB 125 A, 35 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable.
Supply & fix MCCB 63 A, 16 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable.
Supply & fix MCCB 32 A, 16 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble, nut bolt and washers etc complete including disconnecting the existing unserviceable MCCB from panel board after disconnecting cable.
Preparation of old surface by brooming down, steel wire brushing & scrapping down and painting with two coats of white wash on surface of UG Sump and installations all as specified and as specified and as directed
S&F in repairs single phase 230 V 50 Hz Pumpset of capacity head 14 to 22 m ,discharge 7.5 to 2 LPS with suitable starter all as specified and as directed
S&F in repairs single phase 230 V 50 Hz Pumpset of capacity head 14 to 18 m ,discharge 3.6 to 2 LPS with suitable starter all as specified and as directed
S&F in repairs non clog type submersible pumps single phase head 14 to 22 m discharge 69 to 64 LPM with suitable size delivery hose pipe upto 10 m length, suitable starters with 30 m long submersible cable all as specified and as directed
S&F in repairs Capacitor of capacity 15 MfD as per sample suitable for pumpset all as specified and as directed
Supply and filling oil suitable for dosing pump and pumpset/ compressor as per sample all as specified and as directed
Supply ,installing ,testing and commissioning of pump motor of capacity 1 HP 220-240 Volts 750W, 7.5 A,2700 RPM single phase 50 HZ head range upto 10.5 to 44 M discharge upto 15-108LPM, type of insulation B class including protection against over current, low voltage ,dust and water entry IP 44 pressure protection complete including pressure tank, maximum working pressure 10 bar nominal volume 24 Ltr pressure switch to control pump with differential set upto 2 Bar and taking down of existing pump all as specified and as directed
Supply and fix in repairs outdoor type pillar gate light of traditional style black in colour & material is of metal including 9 Watts bulb with holder all as specified and as directed.
S&F in repairs garden spike light of 7 Watts focussing type all as specified and as directed
S&F in repairs underwater recessed fountain light upto 1m depth of wattage 6 W all as specified and as directed
S&F in repairs Single phase preventer 415 V 50 Hz base/DIN rail degree of protection IP 20 for terminals and IP 40 for enclosure all as specified and as directed
S&F in repairs pneumatic solenoid valve as per sample for STP and other installations all as specified and as directed
Supply only Os1 microorganism culture for waste water treatment and bioremedian efforts all as specified and as directed
S&F in replacement of pressure switch of pressure pumpset of capacity 1 HP all as specified and as directed
S&F in replacement 2 core 6 Sqmm LT XLPE cable with necessary items like clamps etc to fix on wall all as specified and as directed
SKV Engineering
CHANDER SEKER ENTERPRISE
M/S SHAJAHAN BUILDERS
bansal construction
kakolil trade agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .