Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.4 L+₹4.0 L (11.5%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹42.9 L+₹8.4 L (24.4%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
28 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR AND MAINT OF ROOF LINTEL CHAJJAS AND REPAIR TO RCC STRUCTURE COMPONENTS OF BLDGS AT OLD RS COLABA UNDER AGE B/R II OF GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_547434_1
8259/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹94,000
Yes
29 Nov 2022
25 Aug 2022
29 Sept 2022
25 Aug 2022
28 Sept 2022
15 Sept 2022
25 Aug 2022 - 21 Sept 2022
Amount
Taking down old existing unserviceable cement plaster, loose / unsound weaken cement concrete of any description and in any position from existing external surfaces of wall, roof , chajja etc with power driven of pneumatic chisel and and removal upto the approval municipal dumping grounds specified by the local bodies out oside MOD land including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from the visible reinforcement by applying rust remover and cleaning the steel reinforcemnt properly and then applying single component cementitious corrosion inhibiting primer for steel reinforcement on visible reiforcement surfaces to form a contineous film not less than 1 mm thick and preparing the surface to receive concrete of epoxy grout mortar etc including providing necessary proportions, bracing and runners to relieve the member from the load coming on it including scaffolding with working plat form as requied and as per design and pattern complete including preparing the surface to match with the existing surface, complete all as specified and directed by Engineer-in-charge.
M&L for providing and applying anti-yellowing coating, The coating to be applied on wall shall be liquid applied highly durable waterproof coating system for wall, based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. It shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth.It shall cover hairline cracks up to 0.5 mm effectively. It shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. The elongation at break is approx. 220 %. The tensile strength is 0.7 Mpa. It has a hardness shore ‘A’ scale of 80, with an adhesion strength of 3.4 Mpa. The coating is UV resistant, algae and fungus resistant, and has a water vapor permeability of 40 gm/m²/day and a crack bridging ability of 1-2 mm. The coating must be applied with temperature above 5°C and below 45°C. The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.Allow applied coating to dry or cure for 3 days complete all as specified and directed by Engineer-in-charge.
M&L for providing and applying three component system based on BPA and having a mix proportion of 2PBW:1PBW:15-17PBW. The compresive strength shall be minimum 50 Mpa. Subsequent layers may be applied after 24 hours. The mixture should be non shrink , high mechanical strength, strong in flexural, compressive and bond strength.complete all specified and directed by Engineer-in-charge.
Taking down unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing surfaces with power driven of pneumetic chisel and removal upto the approval municipal dumping ground outsides MOD land complete all as specified and directed by engineer-in-charge.
M&L for application of Water based acrylic polymer primer cum sealer coating on prepared surface having high performance copolymer emulsion, formulated to achieve specific performance characteristics that shall dry to a transparent finish and supplied as a single component white liquid to exposed concrete or masonry surface after proper surface preparation,cleaning of dust,dirt etc. The system shall form a film and shall have excellent water retention after film formation. complete all as specified and directed by Engineer-in-charge.
M&L for providing and applying a blend of Portland cement, graded fillers and chemical additives which impart controlled expansion, should be ready to use and can fill convoluted voids and cracks , it should componsates shrikage at both plastic and Hardened states. W/P ratio of 0.18. Strength of 1 day to be 20N/mm2. Time of expansion to start after 20min of mixing and finish in 120 min of mixing epoxy bonding agent having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)-11 N/mm2 at 7 days, including all tools and tackles as per accepting officer, complete all as specified and directed by Engr-in-Charge.
Providing and Applying corrosion inhibiting, single component, fibre reinforced, thixotropic, dual shrinkage compensated, thixotropic pumpable mix which should conform to JIS Z 1535. The mortar should have a compressive strength of not less than 40 N/mm2 after 28 days curing. The W/P ratio by weight should be 0.165 and the mass density should be in the range of 1750-1850 Kg/m3 and it should be suitable for vertical and overhead application . The application should be done up to thickness of 20 mm in one layers which is suitable for all structural elements such as beams, columns and slabs as also repairs of structural members subjected to static/dynamic loading and repairs to core members of industrial structures.Cement and sand can be used for finishing the surface even and smooth. Rate should inclusive of material, labour, scaffolding, tools and tackles, complete all specified and directed by Engineer-in-charge.
M&L for applying two coats of Epoxy Resin Based Concrete Bonding Agent for proper bonding between old surface with micro-concrete/new surface.The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C up to which new concrete can be poured. It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa.complete all specified and directed by Engineer-in-charge.
M&L for treating the existing pipe penetrations using non-shrink, free flowing, cementitious grout .The compressive strength of the grout must exceed 50 N/mm2 at 7 days and 60 N/mm2 at 28 days. The flexural strength of grout must exceed 9N/mm2 @ 28 days. Fresh wet density of the mixed grout must exceed 2150 kg/m3. Further flashing the area using solvent based UV resistant polyurethane based waterproofing material having minimum tensile strength on 4 N/mm2 and minimum elongation of 800%. Complete all as specified and directed by Engineer-in-charge.
M&L for form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
M&L for applying cement based waterproofing coating with high negative hydrostatic, good adhesion to substrate and enhanced durabiltiy on concrete or masonry walls. The waterproofing coating should have adhesion to substrate of 1.3 Mpa after 28 days, elasticity modulus of 14000 - 16000 N/mm2 after 28 days and average water/ powder demand of 0.24 to 0.26 for fluid consistency. complete all specified and directed by Engineer-in-charge.
M&L for drilling hole chemical anchoring of reinforcement on existing surface with Hilti HIT-HY 70 or equivalent, minimum hole depth 150mm, steel bar 10mm dia and drill bit dia 12mm, complete all as specified and directed. Make: HT-V-R- M12x150 of Hilti Chemical anchoring polyester resin grout having compressive strength of 20N/mm2 @ 3 hours and an ultimate compressive strength of 70N/mm2 in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983, complete all specified and directed by Engineer-in-charge.
M&L for applying Polyster Resin based Anchoring material in concrete before fixing nozzle it should typically attains a compressive strength in excess of 20N/mm2 @ 3 hours and and ultimate compressive strength of 70N/mm2 in 7 days (50mm x 50mm x 50mm)when tested as per BS 6319 Part 2 : 1983. complete all as specified and directed by Engr-in-charge.
M&L for drilling holes at the location of cracks upto a depth of 75 -100 mm and a dia of almost 14-20 mm and cleaning those holes prior to application. nipples should be fixed in these holes which are to spaced at 1m c/c. A high strength polymer based on BPA and having viscosity less than 200 cps at 25°C and a 7 days compressive strength of minimum 70 MPa.complete all specified and directed by Engineer-in-charge.
M&L for repair to cracks and damaged existing surfaces by structural strenghtening using epoxy injecting grouting with and as under . (a). Fixing of GI nozzles in zig-zag fashion not more than 50cm c/c on RCC surfaces on all directions as required after drilling holes in concrete, fixing GI nozzles with fast setting mortar and covering with renderoc plug. The size of holes shall be 20mm dia and 75mm in depth. (b). Epoxy injection grouting shell be carried out by using standard pressure grouting pump after mixing design and hardner to the extent till refuse to accept further grout complete. (c). Catting and flushing of nozzles with surface after competing grouting and sealing the nozzles with cement morter (1:1) and preparing the surface to match with the existing surfaces complete all as specified and directed by the Engineer-in-Charge
M&L for providing and fixing welded MS wire mesh weighing not less than 1Kg/Sqm of size on the prepared surface & surface should be cleaned and be removed from dirt, fungus and all foreign material complete all as specified and directed by Engineer in Charge.
M&L for applying curing of the surface using water based acrylic emulsion which incorporate specially for its water retention properties. It shoud be non-penetrating continuous film complying with the internationally recognized ASTM C309-90 standards @ 250gms/Sqm. Product should have daylight Reflectance of 70% as per ASTM E-1347 Specific Gravity of 1-1.01 curing efficieny greater than 70% Minimum application temperature 10°C.complete all specified and directed by Engineer-in-charge.
M&L for providing and applying two coats of one part alkaline based material, with corrosion inhibitors and dispersing agents for exposed steel after cleaning to loose scale or oxidized chips from bars, having bulk density 1.25. The material to be applied to the rusted metal with brush for complete wetting of rusted metal surface and allowed to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, etc.Complete all as specified and directed by Engineer-in-charge.
M&L for providing and applying blend of Portland cement, graded fillers and chemical aditives which impart controlled expansion and should be ready to use and can fill convoluted voids, compensates shrinkage at both plastic and Hardened states having compressive strength (BS 4551-80-60) MPA at 28 days, Tensile strength (ASTM C 348)-2.0 N/mm @ 28 days, Flexural strength (ASTM C 348)-9 Notes: 1. Minimum thickness to be used is 50mm with addition of 10mm down aggregates of 25% of the weight of mix ready to use powder with water- powder ratio of 0.18. Strength of 1 day to be 20N/mm2. Time of expansion to start after 20min of mixing and finish in 120 min of mixing Epoxy bonding agent having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days & bond strength (ASTM C 881)-11 N/mm2 at 7 days, having an over lay time of 3 hrs at 30°C. 2. The covering capacity of chemicals indicated is as per manufacturer's instructions. It may vary as per the substrate on plus side and contractor shall have no claim whatsoever on this account, complete all as specified and directed by Engineer-in-charge.
M&L for MS TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
Note: (a) The work for item Sr No. 1 to 23 to shall be executed directly by company or their authorized applicator. Application shall be authorized in writing by company and guarantee/responsibility of work executed shall be owned by Contractor in writing for 5 years. (b) Quoted rate shall be inclusive of material all labors tools and plants scaffolding and working upto G +14 storey building (c) Adoption of necessary safety arrangement like safety belts. ropes. helmets, netting etc. which are required for safety of working at height etc. which are required for safety of working at height exceeding 3 to 45 mtr height shall be mandatary and deemed to be inclusive on quoted rates.
M/s R.D. Company
M/s Raghav Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .