| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | ₹12.3 L Quoted ₹12.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹19.1 LRejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹19.1 L | L2 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | keerti trading corporation L1 | Himanshu Construction and Suppliers L2 |
|---|---|---|---|---|---|
| 1.00 | Providing highly skilled mechanic/ specialist in electric HT breakers/Panels line carrying out the mechanical servicing/overhauling of 33 and 11 KV VCB/SF6 breaker complete by drawing out the trolly from existing HT panels with due care after taking proper shut down from concerned staff, opening of tank, decanning of old carbonised parts and cleaning/decarbonising all mechanical/metal parts with CRC/CTC-226 solution/spray, inspection/ checking of all fixed and moving parts, dressing of male and female contact by using emery paper for fine/smooth contact, meggering of IR value of all HT incoming and out going bushing, providing oil, grease and re-assembling the same by tightening of all connections including checking of alignment for easily movement of breaker for ON/OFF operation with setting of buffer gap adjustment, contact travel allignments , rollar gap , hard or light setting of breaker greasing of all moving mechanism including removing and fixing worn out/cracked/moistured/loosing IR value spare parts ( for which supply of spare parts only will be paid seperately )and fixing the trolly in HT panels and testing, charging the system in presence of Engr in Charge/JE E/M complete all as specified and directed. | 12 | Each Job | 2,500 ₹30,000 | 5,000 ₹60,000 |
| 2.00 | Auxilialary Switch 7NO+7NC | 4 | Each | 500 ₹2,000 | 2,000 ₹8,000 |
| 3.00 | Close coil 24/30V DC Make:L&T/Crompton greave/ABB | 4 | Each | 800 ₹3,200 | 2,000 ₹8,000 |
| 4.00 | Shunt trip coil 24/30V DC. Make:L&T/Crompton greave/ABB | 4 | Each | 800 ₹3,200 | 2,000 ₹8,000 |
| 5.00 | Series trip coil 24/30V DC. Make:L&T/Crompton greave/ABB | 4 | Each | 800 ₹3,200 | 2,000 ₹8,000 |
| 6.00 | Power Pack for HT panel VCB for exection of relay. | 4 | Each | 2,500 ₹10,000 | 7,000 ₹28,000 |
| 7.00 | Supply and fixing of Vaccum intrupter as make of VCB. MAKE: Crompton/ABB | 4 | Each | 5,000 ₹20,000 | 22,000 ₹88,000 |
| 8.00 | Supply and fixing in replacement of spout of existing make of Vaccum circuit breaker as specifed and as directed at site | 4 | Each | 3,500 ₹14,000 | 10,000 ₹40,000 |
| 9.00 | Supply and fixing of PT of 11 KV grade for VCB of existing make as directed at site | 3 | Each | 18,000 ₹54,000 | 30,000 ₹90,000 |
| 10.00 | Supply and fixing of CT of 11 KV grade for VCB of existing make as directed at site | 3 | Each set | 8,000 ₹24,000 | 22,000 ₹66,000 |
Updated dates
Tender Value
₹12.6 L
EMD Value
₹25,200
Closing Date
3 Dec 2025, 6:00 pmClosed
Offg GE I R AND D KANPUR
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF OCB VCB HT CABLE AND CONNECTED WORK AT TECH AREA WMC MES COLONY AND 60 SCIENTIST HOSTEL UNDER GE I R ANDD KANPUR
2025_MES_737771_1
8468/E8
Open Tender
Electrical and Maintenance Works
180 days
KANPUR
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹25,200
Yes
14 Feb 2026
30 Oct 2025
6 Dec 2025
30 Oct 2025
3 Dec 2025
14 Nov 2025
30 Oct 2025 - 13 Nov 2025
Amount
Providing highly skilled mechanic/ specialist in electric HT breakers/Panels line carrying out the mechanical servicing/overhauling of 33 and 11 KV VCB/SF6 breaker complete by drawing out the trolly from existing HT panels with due care after taking proper shut down from concerned staff, opening of tank, decanning of old carbonised parts and cleaning/decarbonising all mechanical/metal parts with CRC/CTC-226 solution/spray, inspection/ checking of all fixed and moving parts, dressing of male and female contact by using emery paper for fine/smooth contact, meggering of IR value of all HT incoming and out going bushing, providing oil, grease and re-assembling the same by tightening of all connections including checking of alignment for easily movement of breaker for ON/OFF operation with setting of buffer gap adjustment, contact travel allignments , rollar gap , hard or light setting of breaker greasing of all moving mechanism including removing and fixing worn out/cracked/moistured/loosing IR value spare parts ( for which supply of spare parts only will be paid seperately )and fixing the trolly in HT panels and testing, charging the system in presence of Engr in Charge/JE E/M complete all as specified and directed.
Auxilialary Switch 7NO+7NC
Close coil 24/30V DC Make:L&T/Crompton greave/ABB
Shunt trip coil 24/30V DC. Make:L&T/Crompton greave/ABB
Series trip coil 24/30V DC. Make:L&T/Crompton greave/ABB
Power Pack for HT panel VCB for exection of relay.
Supply and fixing of Vaccum intrupter as make of VCB. MAKE: Crompton/ABB
Supply and fixing in replacement of spout of existing make of Vaccum circuit breaker as specifed and as directed at site
Supply and fixing of PT of 11 KV grade for VCB of existing make as directed at site
Supply and fixing of CT of 11 KV grade for VCB of existing make as directed at site
Supply and fixing in replacement of T and C switch for VCB as specified and directed at site by Eng-in-Charge
Supply and fixing in replacement of led bulb indicator for VCB as specified and as directed at site
Supply and fixing in replacement of mail and female contacts of VCB of existing make of VCB. Make: ABB/Crompton
Supply and fxing in replacement of Gear mechanism of vcb of existing make as specified and directed at site. Make: Crompton/ABB/GEC
Dismantling existing worn-out 33 KV out door type gang operated air break switch triple pole & Disconnecting from existing system and Supply and installation and testing 33 KV outdoor type ,gang operated Air-break switch triple pole mechanically operated ,mounted on insulator Rotating type Horizental mounting with operating mechanism worked from ground level with 25 mm GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 400 amps 9 insulator connected and out going with Steel nut bolts and washers all as specified and directed at site Make- PACTIL, Jaipuria brothers, National etc)
Routine and periodical cleaning around the area of out door swith yard of 33 KV Tech area, Chanmari and 11 KV sub stn RB, DRLM, T&GS, Nano & Polymer bldg, P29 transformer etc by cutting and removal/uprouting of unwanted grass/bushes, small trees including surface dressing and leveling by surface excavation wherever required complete in all respect or as directed.
Excavation in trenches in any type of soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width and getting out including forming bottom surface & sides to required slope/size as directed by the Engineer-in-Charge
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by the Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed by Engineer-in-Charge.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying un-reinforced precast concrete cable cover HV class type -II with size 450 x 180 x40 mm, all as specified and directed
S&L bricks burnt for protection of cable Sub class 'B' bricks laid dry flat across the cable with length of whole brick complete.
Supply & laying jointing and testing H.T. XLPE Insulated , Screened PVC bedded ,galvanised steel strip or wire armoured electric power cable(heavy duty) with aluminum conductor 11000 volt(E) grade cross sectional area 95 sqmm 3 core confirming to IS-7098 (Part I ) of 1988 laid in trenches/Duct on pole witth FI CLAMP, Nut bolt ,Aluninum Lugs -as required and directed at site Note- Joints will be measured and paid seprately. Make: Havells/Finolex/Polycab
All as per item No.-24 but size of 120 sqmm 3 core 11 KV
All as per item No.-24 but size of 185 sqmm 3 core 11 KV
Supply & laying jointing and testing H.T. XLPE Insulated , Screened PVC bedded ,galvanised steel strip or wire armoured electric power cable(heavy duty) with aluminum conductor 33000 volt(E) grade cross sectional area 120 sqmm 3 core laid in trenches/Duct on pole with FI CLAMP, Nut bolt ,Aluninum Lugs -as required and directed at site Note- Joints will be measured and paid seprately.
All as per item No.-27 but size of 300 sqmm 3 core 33 KV
M&L Heat shrinkable type cable end joint outdoor type suitable for XLPE 120 Sqmm 3 core HT 33 KV cable and testing all as specified and directed with terminate joint and jointing material all as specified.
All as per item No.-29 but size of end joint outdoor type suitable for XLPE 300 sqmm 3 core 33 KV.
All as per item No.-29 but size of end joint indoor type suitable for XLPE 300 Sqmm 3 core HT 33 KV
All as per item No.-29 but straight through joint Heat shrinkable 120 sqmm 3 core 33 KV.
All as per item No.-29 but straight through joint Heat shrinkable 300 sqmm 3 core 33 KV.
M&L Heat shrinkable type cable end joint outdoor type suitable for XLPE 120 Sqmm 3 core HT 11 KV (E) cable and testing all as specified and directed with terminate joint and jointing material all as specified.
All as per item No.-34 but size of end joint outdoor type suitable for XLPE 95 sqmm 3 core
All as per item No.-34 but size of end joint INDOOR type suitable for XLPE 120 Sqmm 3 core HT 11 KV (E) cable and testing all as specified and directed with terminate joint and jointing material all as specified.
All as per item No.-34 but size of 95 sqmm 3 core
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item No.-38 but size of 120 sqmm 3 core
Dismantling existing worn-out old GOD and Supply and installation and testing 11 KV outdoor type ,gang operated Air-break switch triple pole mechanically operated ,mounted on insulator and steel frame with operating mechanism worked from ground level with 25 mm GI pipe (Med. grade) operating rod of suitable length with an ON-OFF position capacity 200 amps with dropout fuse & 12 insulator connected and out going with Steel nut bolts and washers all as specified and directed at site.
Supply and laying GI Pipe light grade 80 mm bore with fittings for cable protection complete as all as required at site and directed.
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 33/11 KV XLPE insulated HT cable complete all as required and directed at site
S&Fin replacement of unserviceabile porceline vitreous bushing of required size / shape (suitable for exisiting transformer ) for spindle of transformer of any capacity 63 KVA to 750 KVA 11KV outdoor/indoor type siutable for HT side all as specified and directed
All as per item No.-43 do but 1100 Volts grade suitable for LT side indoor type
S&F in replacement of unserviceable brass spindle duly threded at the end complete with nut bolts and washer suitable for HT side of transformer out door/ indoor type all as specified and directed at site for the following capacity suitable for existing transformer of required size/ shape for spindle of transformer of any capacity up to 400KVA 11000 volts grade indoor type suitble for HT side all as specified and directed.
All as above item No-45 but suitable for LT side of transformer of 400 KVA to 750 KVA capacity.
M&L Lightning arresters expulsion type complete with all fittings, transmission class, 33 KV discharge capacity 65 kilo amp as specifed and as ditrected by E-in Charge. Make: Jaipuria, Rastriya.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L in replacement of aluminum conductor steel reinforced (ACSR) (any size upto panther) for 33 KV switch yard including, stringing, tightening binding jump ring & testing etc complete all as specified and directed.
Supply and fixing in replacement of PG clamps for jumper connections aluminium die cast with two GI nut and bolts suitable for ACSR conductor upto panther on 33 KV HT OH lines.
Supply, fixing & connecting in replacement of worn out batteries by valve regulated lead acid (VRLA) maintenance free rechargeable battery of 2 Volt, 100AH, conforming to IS 15549/2005 and IEC 60896 - 21 & 22 for tripping system to HT breaker during fault occurence at 33/11 KV Sub station complete all as specified and directed.
M&L for one coat aluminium painting and synthetic enamel painting of all MS channels, PT's, CT's, and other steel structures etc as per colour code of area not exceeding to 150 Sqm after proper preparation of old surface of 33 KV out door switch yard tech area and take over point chanmari complete all as specified and directed.
M&L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron.
S&F in replacement cable rout indicator with MS plate not less that 3.15 mm thick embosed of HT electric line adequate size with welded with 0.50 mtr long MS flat with PCC 1:3:6 (30cm x 30cm x 30 cm) including excavation 30cm x 30cm x 30 cm ,returning, filling and removing of soil including letter wrining for cable size location feeding with stancile as directed at site complete all as specifed and directed.
S&F in replacement ammeter for 33 KV VCB panel digital type having range 0- 200 Amps operated with CT complete all as specified and directed.
S&F in replacement of volt meter for 33 KV VCB panel digital type operated with PT complete all as specified and directed.
S&F in replacement of frequency meter for 33 KV VCB panel digital type operated with PT complete all as specified and directed.
S&F in replacement of Porcelain Post Insulators conforming to IS 2544/731/2486 (Part II), IEC 383/168 & BS 137 suitable for 33 KV nominal system voltage complete all as specified & directed.
S&F in replacement of pin type porcelain, vitreous, white brown or green insulator including 1 galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts suitable for 33 KV complete all as specified and directed.
S&F in replacement of disc insulator, porcelain, vitreousd bolt and socket type, white, brown and green suitable for 33KV(main receiving station) complete all as specified and directed.
Material & Labour in replacement of standard heavy duty capacitor bank cylindrical type 3 phase 440 volts of capacity 25 KVAR including necessary copper lead copper lugs of suitable size all as directed by Engr-in-Charge. Make : L&T/Schinieder/ Epcos/BCH as approved by GE
Material & Labour in replacement of standard heavy duty capacitor bank cylidrical type 3 phase 440 volts of capacity 15/12.5 KVAR including necessary copper lead copper lugs of suitable size all as directed by Engr-in-Charge. Make : L&T/Schinieder / Epcos/ BCH as approved by GE
Material & Labour in replacement of heavy duty gas filled power capacitor bank 3 phase 440 volts of capacity 25 KVAR including necessary copper lead connection of suitable size all as directed by Engr-in-Charge. Make : L&T/Schinieder / Epcos/ BCH as approved by GE
Material & Labour in replacement of heavy duty gas filled power capacitor bank 3 phase 440 volts of capacity 12.5 KVAR including necessary copper lead connection of suitable size all as directed by Engr-in-Charge. Make : L&T/Schinieder / Epcos/ BCH as approved by GE
Supply & fixing in replacement power factor controller relay 6 stepLCD Display, 90 V-550V 50/60/Hz 1A/5A with RS 485 etc complete Make : L& T /SchniederABB
Supply and fixing in replacement of on onload changeover switch of 800 Amps 4 pole 415 V, panel mouting metal enclosure type without enclosure,including labour for alterration in panel etc comlete.
Supply and fixing in replacement of on onload changeover switch of 400 Amps 4 pole 415 V, panel mouting metal enclosure type without enclosure,including labour for alterration in panel etc comlete.
Supply and fixing in replacement of on onload changeover switch of 200 Amps 4 pole 415 V, panel mouting metal enclosure type without enclosure,including labour for alterration in panel etc comlete.
Supply, fixing, connecting and testing in replacement of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps including replacement of connection lead of suitable size with suitable lugs/ clamps complete all as specified and directed
S&F in replacement digital multi function meter three phase, 415 volts having LCD Display,96 x 96 sq.mm Flush mounted case, accuracy class 1.0 capable of measuring Instantaneous, Average, Maximum and Total Current from 5A to 500A and voltage from 120V AC to 300V AC Phase to Neutral, Phase to Phase Voltage, Instantaneous, Average, Maximum and Total Active Power KW, Instantaneous, Average, Maximum and Total Apparent Power KVA, Total Power Factor, Frequency complete all as specified and as directed.
Maintenance & servicing of complete capacitor bank panel of capacity upto 750KVAR including cleaning of all contacts, decarbonising of contactor contacts with petrol/CRC, checking & tightening of all cable/Bus bar connection, CT connections & replacement of worn out parts such as capacitors lugs, CT's etc. APFC relays fuses etc testing on completion for better power factor correction all as directed by Engr -in- charge. Note : Spares shall be measured & paid seperately under supply only items minor spares are deemed to be included in items rate.
Supply, errecting and installation of steel tubular pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint including excavation, earth work, PCC work complete all as spfd and directed
M&L for painting of steel pole upto11 mtr height with cross arms, clamp , GOD of any length for HT Pole with two coat of aluminium paint after scraching out old paint, cleaning and existing surface rust free, preparation of the existing surface, including marking pole numbers in a 20 cm dia yellow circle with number writting with black syenthic paint & painting strips in alternate from bottom to top with three strips of black synthetic paint complete all as specified and directed.
Dismantling existing GOD and repair/servicing , oiling , greasing including lux fixing any type and 25 mm GI pipe alignment ,repair of ON-OFF handle with Steel nut bolts and washers complete all as specified and directed at site.
Himanshu Construction and Suppliers (BID ID -3488589)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender8468.pdf
Tender Documents • 0.97 MB
BOQ_826102.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid