Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.4 L+₹8,500 (0.82%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.2 L+₹82,840.20 (8.00%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹11.6 L+₹1.3 L (12.2%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹12.0 L+₹1.6 L (15.8%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
27 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121 UDHAMPUR
Repair/Maintenance of street/security lights, post top lights, control switches and connected items at JNE area under GE Utilities Udhampur
2020_MES_356422_1
GE/U-25/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹29,000
Yes
7 Sept 2020
27 Jun 2020
29 Jul 2020
27 Jun 2020
27 Jul 2020
13 Jul 2020
60 days
Amount
Taking down carefully Unserviceable HPSV/MH fittings 70 Watt street light / Security light / High Mast light fitting from pole/Structure and repair/replacement of worn out parts such as ballast, lamp, starter, ignitor etc, cleaning of fittings, cover, copper wire,clamps, nuts and bolts, mounting bracket and re assembling the same after repair, testing and refixing in pole/other location including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specified and directed by Engr-in-Charge. Note: - Replacement of defective spare parts of fitting (to make functional) will be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate.
Description all as per serial item No 1.00 here-in-before but HPSV/MH light fittings 150 watt street light fitting.
Description all as per serial item No 1.00 here-in-before but HPSV/MH light fittings 250 watt street light fitting.
Description all as per serial item No 1.00 here-in-before but HPSV/MH light fittings 400 watt street light fitting.
Description all as per serial item No 1.00 here-in-before but HPSV/MH light fittings 250 to 400 watt double ended lamp street light fitting.
Supply only Copper wound Ballast suitable for 70 watt HPSV/MH light fitting materials suitable for various type of street light, security light for replacing against serial item No 1.00 here in before. Make: Bajaj/Crompton/Philips
Description all as per serial item No 6.00 here-in-before but Copper wound Ballast suitable for 150 watt HPSV/MH light fitting.
Description all as per serial item No 6.00 here-in-before but Copper wound Ballast suitable for 250 watt HPSV/MH light fitting.
Description all as per serial item No 6.00 here-in-before but Copper wound Ballast suitable for 400 watt HPSV/MH light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 70 watt MH light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 150 watt MH light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 250 watt MH light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 400 watt MH light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 70 watt HPSV light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 150 watt HPSV light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 250 watt HPSV light fitting.
Description all as per serial item No 6.00 here-in-before but Lamp suitable for 400 watt HPSV light fitting.
Description all as per serial item No 6.00 here-in-before but Electronic igniters suitable for 70/150/250/400 Watt.
Description all as per serial item No 6.00 here-in-before but Capacitor 10 mfd/20 mfd/33 mfd HPSV, MV, MH lamp fittings.
Taking down existing old PCC/Steel poles complete all as specified and directed by Engr-in-Charge. Note: - Damaged poles shall be removed from the site as per direction of Engr-in-Charge.
Dismantling/Taking down of old UNSV ACSR/Conductor of any size for LT OH line, earth wire & cradles complete all as specefied and directed by Engr-in-Charge.
Taking down existing old cross arms of MS channel or angle sections etc all as specified and directed by Engineer-in-Charge.
Dismantling of old insulators pin/shakle complete and keeping aside for removal complete all as specefied and directed by Engr-in-Charge.
S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - Excavation and Earth Work ,PCC in foundation shall be measured and paid for separately.
Supply, Laying, jointing in replacement & testing 1100 Volts grade heavy duty cable PVC tape PVC sheathed 2.5 Sqmm aluminium solid conductor 2 core nominal cross section laid in trenches/fixed to walls/ passing under the roads in existing pipes etc including takind down old UNSV cable complete all as specefied and directed by Engr-in-charge.
S&F in replacement modular box of size 333 x 233 x 120 mm made of FRP inpact resistance plastic & heat resistant materials including MCB SP 6 A, Connector terminal block 4 pole 16 A capacity and fixing to the street light or post top light pole with suitable sizes of clamps, nuts and bolts complete all as specefied and directed by Engr-in-charge.
S&F in replacement MS bracket for street light fittings made out of 40 mm dia GI pipe of medium grade 1.5 mtr long each bent to required shape & size and fixed to pole with and including flat iron clamps 02 Nos made out of 32x6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with two coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fittings complete all as specefied and directed by Engr-in-Charge.
S&F in replacement 150 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.
S&F in replacement 90 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 9000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.
S&F in replacement 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge.
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and exceeding 1.5 mtr depth upto 3 mtr and getting out complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
M&L for sand cushioning to UG cable laid in trenches with clean dry river sand 8 cm below & 15 cm above the cable & punned down to 18 cm thickness complete all as specified and directed by Engr-in-Charge. Note: - For payment purpose 18 cm thickness shall measured.
S&F burnt brick sub class B for cable protection laid adjacent to each other perpendicular to the direction of cable in trenches complete all as specefied and directed by Engr-in-Charge.
M&L for cement concreate 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specefied and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specefied and directed by Engr-in-Charge.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specefied and directed by Engr-in-Charge.
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laind in trenches or passing through pipe or fixed on poles complete all as specefied and directed by Engr-in-Charge.
Description all as per serial item No 40.00 here-in-before but of size 16 Sqmm 4 core
Description all as per serial item No 40.00 here-in-before but of size 25 Sqmm 4 core.
Description all as per serial item No 40.00 here-in-before but of size 35 Sqmm 3.5 core.
Description all as per serial item No 40.00 here-in-before but of size 50 Sqmm 3.5 core.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe , complete all as specified and directed by Engineer-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe , complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specefied and directed by Engr-in-charge.
S&F in replacement MS Channel/angle iron/flat iron of required size and bend to shape as cross arms, bracing and support including, MS clamps back plates with bolts, nuts, and washers drilled for insulators including painting two coats of synthetic enemel paint (Aluminium shade) over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specefied and directed by Engr-in-Charge.
S&F in replacement Power contactor 3 phase 415 Volts, 40 Amps, coil voltage of rating 240 Volts including taking down old unserviceable power contactor complete all as specefied and directed by Engr-in-Charge.
S&F in replacement Power contactor 4 pole 240 Volts, 32 Amps , coil voltage of rating 240 Volts including taking down old unserviceable power contactor all as specified and as directed by Engr-In-Charge.
Taking down the existing LED street light fittings of any type and make checking the serviceability and replacing the defective driver with new one complete all as specefied and directed by Engr-in-Charge.
S&F in replacement driver for LED energy saving & enviornment area light fitting > 90 watts security light with active power factor correction (APFC) electronic driver. LED driver 90 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge.
S&F in replacement driver for LED energy saving & enviornment area light fitting > 48 watts security light with active power factor correction (APFC) electronic driver. LED driver 90 Watt with operating voltage between 100-270 V of existing specifications & make complete all as specefied and as directed by Engr-in-charge.
M&L for in replacement earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
S&F in replacement switch fuse unit in sheet steel enclosure powder coated, weather proof confirming to IS 13947 (Part 3) 1993 with rewireable and HRC cum rewireable of Capacity 400 Amps four pole 415 volts with fuses including taking down old u/s switch fuse unit all complete all as specefied and directed by Engr-in-Charge.
vijay kumar gupta and co
ARNABH ASSOCIATES
proach associates
PREM NATH KHAJURIA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .