Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC B 4 47 BUDHYAPARK BBD PALLY P O P S KALYANI DIST NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | ₹26.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹26.7 LRejected-AOC | ₹26.7 L | L2 | Rejected-AOC L2 |
| 3 | L3₹26.7 LRejected-AOC 22 LASKARDIGHI WEST DIST PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | ₹26.7 L | L3 | Rejected-AOC L3 |
| 4 | L4₹27.3 LRejected-AOC RAJABAGAN MOKDUMPUR ENGLISH BAZAR MALDA WB 732103 | ENGLISH BAZAR | MALDA | WEST BENGAL | 732103 | ₹27.3 L | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹53,500
Closing Date
21 Jan 2026, 6:55 pmClosed
Executive Engineer (AM), Malda-II (AM) Division
Executive Engineer (AM), Malda-II (AM) Division, Madhabnagar, Mokdampur, Malda, Administrative Building (1st Floor), Mokdampur-732103, Malda.
Conversion of Kanaipur State Owned and Operated Major RLI at Mouza-Kanaipur, Block Chanchal-II in the District of Malda under the Executive Engineer (A-M), Malda-II (A-M) Division under Core-Sector Program for the Financial Year 2025-26
2026_WRDD_984035_1
WRDD/EEAM /MLD-II /NIT-07(e)/25-26
Open Tender
CIVIL AND ELECTRICAL WORKS
180 days
Kanaipur, GP-Chandrapara, Chanchal
Please refer Tender documents.
7 documents required · 7 mandatory
₹53,500
27 Jan 2026
6 Jan 2026
23 Jan 2026
6 Jan 2026
21 Jan 2026
6 Jan 2026
PART-I :-PROCUREMENT OF MATERIALS
20 H.P. Electro Motor Pump set having capacity of 200 m³/hr discharge at 18 meter total head. The Motor shall be designed for operation at 415 V (+10%), 3 Phase, 50 Cycles per sec. (± 5%), A.C. Supply 1500 r.p.m. The Motor shall be TEFC, ISI marked as per IS 325/1996 with latest amendments thereof. The Motor and Pump set (Monoblock) (as per IS 14285:1995) and mounted on a common fabricated M.S. Baseframe. Centrifugal pump shall confirm to IS: 6595(Part-I)/2002 and motor to 15-12615:2011with latest amendments thereof and must have ISI certification mark.
200A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested by CPRI/ERDA/BIS lab tested as per latest IS: 10027-2000 and IS/IEC 60947-3
63A Heavy duty rewireable Switch Fuse Units with fuse base and carrier, shall comply with and be tested as per latest IS: 10027-2000 and IS/IEC 60947-3, marked with standard ISI certification mark.
20 HP 3Phase electromagnatic Star Delta motor controllers with 4 pole heavy duty power contactor single phasing preventer and normal protective features, MCB (Indicator, puh button, Ammeter & voltmeter, all in IP 54 encloer of min 16wg, CR sheet , 10 tank process powder coat painting and as per technical specification)
415 Volt, 200Amps Busbar Chamber, IS 60947200 Amps, 500Volts bus bar Unit conforming to latest IS 8623:1993 & IS/IEC: 60947, with detachable front cover and undrilled detachable/integrated end plates with 2nos inlet holes of 1.5" size and 4 way/6way outlets, suitable for mounting on wall and designed for uninterrupted duties. The enclosure should be of adequate size to provide minimum clearance as mentioned in technical specification to accommodate 4 nos copper bar with at least 6 nos tap off points of 6mm dia at 30mm apart supplied with requisite brass / S.S nuts & bolts equivalent tobore size with spring / Belleville washers.including arrangement of double earthling by 10 SWG GI wires .
Supply of 50 sqmm 3.5 core XLPE insulated armoured overall PVC sheathed 1100 volts grade power cable conforming ti IS :7098 (PART-I) 1988 with latest amendment
PART-II, III & IV:- CONSTRUCTION OF PUMP HOUSE, ENERGIZATION & INTERNAL WIRING
Rate from Persentage BOQ (BOQ2) i.e. Amount for all related works
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Part-II: CONSTRUCTION OF PUMP HOUSE
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidated the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Ordinary Cement concrete (Mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any, in ground floor as per relevant IS codes.(a) Pakur variety
Hire and labour charges for shuttering with centering and necessary staging upto 4 metre using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm. to 30 mm. thick wooden shuttering. For PUMP HOUSE
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. For works in foundation, basement and upto roof of ground floor / upto 4m. Tor steel/Mild steel ( Other than SAIL/ TATA/RINL) i)For foundation Blocks of Water Distribution System
Brick work in cement mortar (1 : 6) with first class kiln burnt bricks including racking out joints, scaffolding and other incidental works etc. complete. a) In foundation & plinth.
b) In superstructure ground floor
Plaster (to wall, floor, ceiling etc.) with (1:6) sand and cement mortar including rounding off or chamfering corners, as directedand racking out joints or roughening of concrete surface including throating. Nosing and drip course as necessary at ground floor. a) 15 mm thick with 1:6 cement mortar.
b) 20 mm thick with 1:6 cement mortar.
c) 10 mm thick with 1:4 cement mortar.
25 mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Water proofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thick
Neat cement punning about 1.5 mm. thick in wall dado, floor, drain, door and window sill etc. complete.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(ii) Grill weighing above 16 Kg./sq.mtr and above.
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150 mm apart complete in all respect as per design including cost of all labour and materials.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete . A) UPVC Pipes:(i) 75 mm. Dia
B) UPVC Fittings: a) Plain Tee (i) 75 mm. Dia
C) Bend 87.5 degree (i) 75 mm. Dia
Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150 mm. Including watering and ramming etc. layer by layer complete with earth obtained from excavation of foundation.
Priming one coat on steel or other metal surface with synthetic enamel / oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. Two coats (super gloss hi- gloss except white)
White washing including cleaning and smoothening surface thoroughly (5 parts of stone lime and 1 part of shell lime should be used in finishing coat) all floor. (a) Three coats
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.ii) b) Two coats
Supply Fitting fixing of best quality lock & key for door off Godrej make
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
Carriage charge onevery item from Sl. no-1.01 to 1.27 excluding Sl. No-1.01,1.21 & 1.27
Add 18% GST
Add 1% Cess
Part-III: ENERGIZATION (A) QUOTATION
Supervision Charge
Security Deposit
(B) MATERIAL COST
Pcc Pole 9 Mtr long (Material Code- 110030241)
LT Mtering kiosk (Material Code- 407010141)
11 kv Polymer Comp. wh fttg Pin Insl. 5 KN (Material Code-508011141 )
11 KV Polymer Composite 45KN Disc Insulator (Material Code-508030541)
Hardware fittings 11KV (Material Code- 504010132)
M.S.Chanel 100 X 50 MM (Material Code- 102010911)
M.S.Chanel 75 X 40 MM (Material Code- 102010611)
M.S.Angel 65 X 65 X 6 MM (Material Code-101011311)
M.S.Angel 50 X 50 X 6 MM (Material Code- 101011011)
M.S.Flat 65 X 6 MM (Material Code- 103011511)
ACSR Conductor 50 Sq mm (Material Code- 502010921)
TPGO Isolator (200 Amps) 11 KV (Material Code-304010532)
Lightning Arrestor 12 KV (Material Code- 309010841)
Turn Buckle 18 X 5/8'' (Material Code- 912011441)
DTR 63 KVA 11/0.433KV, 3PH O/D WH SLNO (Material Code- 301018241)
Caution Board - 11 KV (Material Code- 910010241)
PVC Cable 4 Core120 sq mm (Material Code- 501018121)
H.T. Stay Set Complete (Material Code- 504130432)
H.T. Guy Insulator 11 KV (Material Code- 508040841)
G.I. Stay Wire 7/10 SWG (Material Code- 503050711)
G.I. Earth Spike 6*3.25ft (Material Code-504110541)
G.I. 8 SWG Wire (4mm) (Material Code- 503010711)
G.I. 6 SWG Wire (5mm) (Material Code- 503010811)
(C) LBOUR COST
Survey for HTOH Line
GIS Survey for pole
Erection of 9 mtr PCC Pole (HT)
Erection of S/stn. D.P. structure (9 mtr)
Erection of 9 mtr Double PCC pole (HT)
Extension of Pole
Fixing of Kiosk and main switch and complete connection with PVC cable (Single Switch)
Stringing & Sagging with 50 sqmm ACSR 3 wire
Earthing complete
HT Stay set complete
Fixing of 11 KV Pin Insulator
Fixing of 11 KV Disc Insulator
Fixing of 11 KV TPGO Isolator on Sub-Stn.
Fixing of 11 KV Lightning Arrestor
Erection of 63 KVA Transformer
Earthing of Neutral point of Distribution Transformer
Fabrication & Fixing of Cradle Guard Bracket (SP)
Fabrication & Fixing of Cradle Guard Bracket (DP)
Fixing of Cross lacing
Lead wire above upto 60 Mtrs (2 Wire)
Fixing of Solid Tee-off Bracket on SP
Fixing of Caution Board
Add 18% GST (on Lobour)
Add 1% Cess
Part-IV: INTERNAL WIRING
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall I(for fitting & fixing of electrial equipments as necessary on the plank).
Supply, Fitting & fixing of DPIC main switch 15/16A 240 Volts (Havells) on board on wall including mending good the damage for light circuit of pump house
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set
Supply & Fixing of 20 watt single / twin florescent light fitting complete with all accessories directly on wall / ceilling / TW round block and suitable size of fastener.
Wiring from 15/16A DPIC main switch to Busbar box in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) of 2 x 36/0.3(2.5 Sq. mm) + 1 x 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc incl supply of wire.
Wiring from 15/16A DPIC main switch to BDB in 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 2X 36/0.3(2.5 Sq. mm) + 1 X 22/0.3(1.5 Sq. mm) in PVC casing capping (Precision make) including necessary PVC clips,fittings etc.incl supply of wire
Distribution wiring in 1.1KV grade 2 x 22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to light/fan/calling bell with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works incl. supply of wire.[PVC casing capping and switch board both on surface] average run 5 meter
Distribution wiring in 1.1KV grade 2X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire (Finolex/havells/KDK) with 1X22/0.3 (1.5 Sq. mm) single core stranded 'FR' PVC insulated and unsheathed copper wire for ECC, including necessary PVC clips,fittings etc. to 5amps 3 pin flush type plug socket with piano key type switch of (Anchore make) fixed on sheet steel fabricated switch board with perspex/ bakelite top cover on wall including necessary connections and making earthing attachments and mending good damages to the building works.[PVC casing capping and switch board botyh on surface] average run 1.5 meter
Fitting & fixing of 200A 500 V iron clad/ sheet steel TP/ TPN main switch on iron legs on wall.
Fitting & fixing of 63A 500 V iron clad/ sheet steel TP/ TPN main switch/isolators on iron legs on wall .
Fitting & fixing of only 200A 500V iron clad M.S. sheet metal busbar chamber on angle iron frame on wall for 4 bars 63Amps.
Fitting & fixing of Star - Delta starter (for 20 HP motor contol) on angle iron frame on wall .
Fitting & fixing of Volt meter and Ammeter with necessary screws and other fixing materials including making holes where necessary and making connections
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall/Kiosk Box, including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to lEE regulation and as per direction of EIC. (Brand: Gloster/Havells/Finolex) [a] For Major RLI. (i) 4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to BUS-bar
(ii) 3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
(iii) 2 X 3C X 6 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (lSI-Medium quality) If Star-Delta Motor controllers to Motor]
Suppling & fitting & fixing of danger Board (mannual) 4"x6" in two distinguishing position in the door of pump house (outside) and at the palce of panel board.
Earthing with 50 mm (2") dia Galvanized iron pipe(TATA MAKE) 3.64 mm thick X 3.04 mtr.(10ft) long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm (1/2") dia X80 mm (3") long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. (12") below the ground level and restoring the surface duly rammed for Soft/Morrum soil by ISI-Medium G.I. Pipe
Supplying and fixing earth bar of galvanized M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilloed holes (on busbar) about 3 cm. apart complete with G.I. bolts, nuts, washers etc. as required for tapping.
Connecting the equipments to earth busbar including supplying and fixing G.I. Wire No. 8 SWG on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages.
Suppling fitting & fixing of shock treatment chart in a wooden frame with brass.(local market rate)
Installation of Electro motor pumping set of any make- brand and for RLI scheme on pump foundation over SAL sleeper(to be sublied departmentally) by supllying and fixing nuts and bolts and making connection of suction hose and foot valve with necessary fitting at the enlet end of the water pump and fitting fixing of 90 degree MS priming bend Sluice valve and delevery hose with all necessary fitting at the deevery end of the water pump, duly connected with pipe line maintainig proper allingment and level including cutting holes on the wall and pump base of the pump house where necessary, mainding good damages after complition of the works as per direction of Engineer -In -Charge.(Pump Set and all accessaries will be suplied departmenatally (a) For Major RLi schemes.
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger.
e)Supplying & fitting fixing and interconnecting the 6KVA Capacitor JAVIC/KELTRON from bus bar by loop wiring with 660 Volt grade
Supply and fitting, fixing etc. complete of RYB power indicator lamp.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Add 18% GST
Add 1% Cess
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tendernotice_2.pdf
PDF • 0.69 MB
Tendernotice_3.pdf
PDF • 0.29 MB
Tendernotice_4.pdf
PDF • 0.73 MB
Tendernotice_5.pdf
PDF • 0.34 MB
Tendernotice_6.pdf
PDF • 0.81 MB
BOQ_2400999.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid