Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.5 L+₹57,893.61 (1.35%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance BEING L2 REJECTED | |
| 3 | L3₹44.7 L+₹1.8 L (4.21%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L3 | Rejected-Finance BEING L3 REJECTED | |
| 4 | L4₹45.0 L+₹2.1 L (4.87%)Rejected-Finance | L4 | Rejected-Finance BEING L4 REJECTED | |
| 5 | L5₹45.8 L+₹2.9 L (6.67%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance BEING L5 REJECTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
Naval Station Karanja Uran Raigad Maharashtra 400 704
REPAIR MAINT OF GARDEN LIGHTS POST TOP LANTERN BUILDING SECURITY LIGHTS AND OTHER CONNECTED WORKS UNDER AGE EM I AT NAVAL STATION KARANJA
2023_MES_610654_2
8691/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW KARANJA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹90,000
Yes
26 Oct 2023
25 Aug 2023
15 Sept 2023
25 Aug 2023
13 Sept 2023
1 Sept 2023
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : TPP 23-24 Ser No. 71 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Taking down and dismantling existing Garden light /Gate light/ Bollard light/post top fitting any type any wattage complete all as specified and directed.
Taking out cable loop after necessary excavation , cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface complete all as specified and directed for the following sizes:-
2/3.5/4 core 4 to16 Sqmm
3.5/4 core 25 Sqmm
3.5/4 core 35 Sqmm
3.5/4 core 50 Sqmm
S&F Cable Junction Boxes IP 66 ,weather proof for outdoor installation of size 155 mm x210 mmx92 mm complete with electrolytic aluminum bus bar suitable cable size 10-16 sqmm for 3 phase and neutral fixed on ebonite insulator and one SPN 6-16 A MCB complete all as specified and directed.
S&F Cable Junction Boxes IP 66,weather proof, for outdoor installation of size 205 mm x255 mmx112 mm complete with electrolytic aluminum bus bar suitable cable size 10-25 sqmm for 3 phase and neutral fixed on ebonite insulator and one SPN 6-16 A MCB complete all as specified and directed.
S&F LED post top 45 W New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. LED CCT is 5700 K & post top light having inbuilt driver with suitable surge protection. Clear Cover offers bright illumination for different applications complete with all accessories complete all as specified and directed.
S&F LED post top 45 W New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.LED CCT is 3000 K & post top light having inbuilt driver with suitable surge protection. Clear Cover offers bright illumination for different applications complete with all accessories complete all as specified and directed.
S&F LED post top 40 W New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.LED CCT is 5700 K & post top light having inbuilt driver with suitable surge protection. Clear Cover offers bright illumination for different applications complete with all accessories complete all as specified and directed.
S&F 8/9 W LED Bollard fitting of size 300 mm with New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power as light source of size 300 mm complete with all accessories,LED CCT is 5700 K & bollard light having inbuilt driver with suitable surge protection and making suitable foundations complete all as specified and directed.
S&F 8/9 W LED Bollard fitting of size 600 mm with New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power as light source of size 600 mm complete with all accessories, LED CCT is 3000 K & bollard light having inbuilt driver with suitable surge protection and making suitable foundations complete all as specified and directed.
S&F 8/9 W LED Bollard fitting of size 600 mm with New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power as light source of size 600 mm complete with all accessories, LED CCT is 5700 K & bollard light having inbuilt driver with suitable surge protection and making suitable foundations complete all as specified and directed.
S&F 8/9 W LED Bollard fitting of size 1000 mm with New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power as light source of size 1000 mm complete with all accessories, LED CCT is 5700 K & bollard light having inbuilt driver with suitable surge protection and making suitable foundations complete all as specified and directed.
M&L for checking serviceability of garden light/gate light/bollard light etc and if found unserviceable during checking then rectification of fault of garden light/gate light/bollard light etc by deploying resource with all tools & plants, ladder, gaskets, safety arrangements and including providing minor materials like insulation tape and connected material to make light serviceable complete all as specified and directed. NOTES :- (i) Rate quoted shall deemed to be included for required minor material like insulation tap/repairing of junction box with lugs etc. (ii) Each job consist of minimum 10 No of complaints . (iii) Items like driver, ignitor, surge protection, lamp, ballasts and other items required for rectification of defects shall be measured and paid separately.
S&F 1.5 Sqmm FRLSH PVC insulated single core unsheathed industrial multistrand cable with flame retardent low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010 complete all as specified and directed.
S&F,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts/drawn through DWC pipe of following sizes incl taking out cable complete all as specified and directed. 2 core 4 Sqmm
2 core 6 Sqmm
4 core 10 Sqmm
4 core 16 Sqmm
4 core 25 Sqmm
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point complete all as specified and directed .
M&L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed. Note : Punned thickness shall be measured.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
S&F MS nut bolts,SS nut bolts ,clamp ,screw of different size and sample complete all as specified and directed.
S&F UPVC pipe 20 mm bore fixed complete to walls, pillar etc., for conduit of wire with all fittings complete & saddling of pipe in pillar with clamp fixed in repairs complete all as specified and directed.
S&F GI pipe Medium grade 50 mm bore with all fittings complete laid in trenches complete all as specified and directed.
S&F GI pipe Medium grade 40 mm bore with all fittings complete laid in trenches complete all as specified and directed.
Dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable size to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right.
The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
(d) Single phasing preventing, under voltage, over voltage and neutral Loss protection relay 415 VAC, 3 Phase 4 wire, 2 C/O and with technical parameters as per M/s L&T Cat part no. - MAC04 D0100 - 01 No. (e) Double pole toggle switch ON-OFF-ON, 250 V, 20 A - 01 No. (f)multi function meter having LCD Display,96 x 96 sq.mm -01 No (g) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (h) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (j) Aluminium bus bar of size 200 Amps rating for R-Y-B phases and Neutral. (k) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (l) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
M&L for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc complete all as specified and directed. Note: GI strip 32x6mm GI medium grade protection pipe 40mm dia upto 7.5m is deemed to be included in the quoted rate.
M&L for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion& connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc complete all as specified and directed. Note: GI lead wire 4.0mm dia and GI medium grade protection pipe 20mm dia upto 7.5m is deemed to be included in the quoted rate.
Supply and laying of 50 mm outer dia ,double wall corrugated (DWC) duct pipe conforming to IS 16205 (Part 24) with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and directed.
S&F in replacement LED drivers of 45 W suitable for post top lantern as per existing driver complete with all accessories complete all as specified and directed.
S&F in replacement LED lamp of 10 W with wider light spread of 180 degree beam angle with BEE 3 star rating complete all as specified and directed.
S&F in replacement LED Aviation light Luminaires integral light comprising of aluminium housing with plycarboanate enclosure 302 LED with complete testing complete all as specified and directed.
S&F decorative LED post top 30 W New generation, IP 66 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source.LED CCT is 3000 K & post top light having inbuilt driver with suitable surge protection. Clear Cover offers bright illumination for different applications complete with all accessories complete all as specified and directed.
M.K Enterprises
SREE HARITHA ASSOCIATES
venus enterprises
M/s S.D Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .