| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAdmitted-Finance ADARSH COLONY GOLE KA MANDIR GWALIOR MP | GWALIOR | MADHYA PRADESH | 474001 | ₹34.4 L | L1 | Admitted-Finance |
| 2 | L2₹44.0 L+₹9.6 L (28.0%)Admitted-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | ₹44.0 L+₹9.6 L (28.0%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Uma engineers L2 | M/S uneversal agency L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable package unit capacity 3 x 5.5 TR including all components like package unit, cooling tower, motor, LT Panel, cable, foundation of all equipment, supply / return air duct, piple line network, water storage tank, diffuser etc and deposited into AGE E/M Store yard complete including removing of false ceiling for removal of Air duct and re-fixing properly after installation of duct and diffuser.
Note : Any damaged false ceiling shall be replaced free of cost to match the existing surface of false ceiling. | 1 | Job | 30,000 ₹30,000 | 25,350 ₹25,350 Lowest |
| 2.00 | Design, supply, installation, testing and commissioning of water cooled Floor mounted packaged Air Conditioner capacity not less than 11 TR (1,32000 BTU/Hr) air flow not less than 4400 CFM, copper cooling coil with aluminium slit fins fitted, Hermatically sealed Scroll compressor working of R-410A refrigerant, water cooled shell and tube type condenser, thermostatic expansion valve, Direct expansion evaporator coil, all controls and Microprocessor based controllers with LCD Display and all other accessories required for efficient working of package unit including PCC foundation work as per OEM instruction, condensate water drain pipe complete all as specified and directed by Engr-in-charge.
Make :- Bluestar Model No DPW 1322 R3 or equivalent make of Voltas / Daikin / Carrier | 2 | Job | 6,81,835 ₹13,63,670 | 4,31,000 ₹8,62,000 Lowest |
| 3.00Supply, fabrication installation and testing of factory fabricated GSS metal ducts as per IS 277 (120 GSM both sides LFQ & confirming to class VIII) for GS sheets and IS-655 for fabrication of duct as per size mentioned in IS-655 according to size of duct with gauge of sheet including necessary G.I hangers/supports, volume control duct dampers, accessories vanes, 3 mm WPDM rubber gasket etc. complete as per specification in accordance with the approved shop drawing : the cost shall be inclusive of following: (i) Ducts with reinforcement/ strengthening. (ii) Air tight joints. (iii) Accessories such as splitter, damper, guide vane etc. (iv) Hangers, Fastener and supports; Rectangular duct should be support from ceiling/wall with bracket/Gripple wire/hanger etc. Selection should be as per site condition and drawing. (v) Painting with black colour paint for duct sides behind the grills. (vi) The gasket used in case for all ducts shall be fire retardant type (vii) Taking dwon existing false ceiling for fixing of duct and re-fixing of the ceiling properly including replacement of damaged accessories after installation of air distribution network. Note : Duct design shall be carried as per IS 655: 2006 & the latest edition of HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at site complete all as specified and directed by engineer-in-charge. | |||||
| 3.01 | GSS metal ducting with 24 gauge24 Gauge | 150 | Sqm | 1,200 ₹1,80,000 Lowest | 1,300 ₹1,95,000 |
| 3.02 | GSS metal ducting with 22 gauge24 Gauge | 80 | Sqm | 1,400 ₹1,12,000 | 1,300 ₹1,04,000 Lowest |
| 4.00 | Supply, fabrication, installation and testing the flexible connections constructed of fire resistant double layer resin sleeve and Jib opening as required all as per the OEM Instruction complete all as specified and as directed. | 2 | Each | 2,500 ₹5,000 Lowest | 3,900 ₹7,800 |
| 5.00 | Supply, installation, testing and commissioning of high performance air foil class 1A leakage rated GI volume control damper having galvanised steel hat channel frame reinforced with corner braces, galvanised steel airfoil shaped blades (double skin construction) of 18 gauge thicknes, neoprene blade edge seals, flexible metal compressible jamb seals, stainless steel sleeve, linkage concealed in frame, etc. tested as per AMCA Standard 500-D-98 complete all as specified and directed by Engineer-in-charge. | 2 | Sqm | 14,500 ₹29,000 | 13,100 ₹26,200 Lowest |
| 6.00 | Material & Labour for square / rectangular / round neck of size not less than 450 mm X 450 mm rectangular neck 4-way discharge ceiling return diffuser having neck velocity ≤ 600 ft/min, throw ≥ 19' @ 150 ft/min velocity NC ≤ 26 for air flow ≥ 1057 ft3/min ceiling return diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square / rectangular inlet being an integral part thereoff, an inner core assembly consisting of fixed deflection louvers, throw reducing vanes, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 170-1991 complete all as specified and directed by the Engineer-in-charge. | 24 | Each | 4,500 ₹1,08,000 | 4,200 ₹1,00,800 Lowest |
| 7.00 | Material & Labour for CBRI certified 16-gauge GI fire damper ( Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.) , at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated cross overs (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directed by the engineer-in-charge.
The fire dampers shall meet the following criteriaon:-
[i] Bare fire dampers with 400 mm sleeve
[ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
[iii] Interconnection wire for the fire detection & alarm system with the LCD fire damper controller. [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer. | 2 | Each | 24,500 ₹49,000 | 13,000 ₹26,000 Lowest |
| 8.00 | Supply, installation, test and commissioning of 10mm thick accoustic insulation inside the duct with engineered nitrile rubber open cell foam with density 140-180 kg / cum and class - I fire performance and with antimicrobial as per ASTM E 21 using manufacturer's recommended rubber based adhesive in a solvents complete all as specified and directed. | 15 | Sqm | 1,500 ₹22,500 | 1,100 ₹16,500 Lowest |
Tender Value
₹38.6 L
EMD Value
₹77,128
Closing Date
10 Nov 2025, 6:00 pmClosed
Cwe AF Gwalior
HQ CWE AF Gwalior
SPECIAL REPAIR/REPLACEMENT OF BER CENTRAL AC PLANT OF AVIONICS LAB AND SPECIAL REPAIR / REPLACEMENT OF BER CHILLER PLANT AT P-77 (ATEC BLDG) IN TECH AREA AT AF STN GWALIOR.
2025_MES_734141_1
86022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Tech Area
As per tender document
9 documents required · 9 mandatory
₹500
GE AF Tech Area
₹77,128
Yes
17 Nov 2025
7 Oct 2025
17 Nov 2025
7 Oct 2025
10 Nov 2025
22 Oct 2025
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.26 MB
BOQ_822026.xls
BOQ • 0.38 MB
TENDER.pdf
Tender Documents • 3.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .