Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 CrAccepted-AOC | ₹9.8 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹10.7 Cr+₹90.5 L (9.26%)Rejected-Finance | ₹10.7 Cr+₹90.5 L (9.26%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹10.9 Cr+₹1.1 Cr (11.2%)Rejected-Finance | ₹10.9 Cr+₹1.1 Cr (11.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹11.3 Cr+₹1.5 Cr (15.6%)Rejected-Finance | ₹11.3 Cr+₹1.5 Cr (15.6%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹11.4 Cr+₹1.6 Cr (16.4%)Rejected-Finance | ₹11.4 Cr+₹1.6 Cr (16.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹12.2 Cr
EMD Value
₹9.3 L
Closing Date
11 Jul 2024, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386 C/O 56 APO
PROVN OF SECURITY WALL WITH ALLIED INFRASTRUCTURE IN NORTHERN GARRISON AT SUNDERBANI
2024_MES_658128_1
87927-A/E8
Open Tender
Civil Works
Lump-sum
545 days
Akhnoor
AS per NIT
8 documents required · 8 mandatory
₹3,000
GE (N) AKhnoor
₹9.3 L
Yes
Udhampur
5 Oct 2024
6 Jun 2024
18 Jul 2024
6 Jun 2024
11 Jul 2024
6 Jul 2024
15 Jun 2024 - 18 Jun 2024
20 Jun 2024
Amount
Sch 'A' Part - I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Construction of elevated Guard Post complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' -III (Area Drainage)
Total Amount of Sch 'A' -IV (Security Wall, RCC Wall, Steel Gate and Fencing work)
Total Amount of Sch 'A' Part -V ( External Water Supply Work)
Total Amount of Sch 'A' Part -VI (External Electric Supply Work)
Sch 'A' Part - VII (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Rectangular anti climb high security electrical resistance galvanised wire weld mesh panels ( size 955mm x 2667mm ± 5mm tolerance, each weighing 23.25Kg ± 5% tolerance) and subsequently powder coated, installed with necessary clamps, profile plates complete all as shown on drgs, specified and directed. Mesh wire diameter & tolerance_ : Core diameter of the horizontal wire : 4mm + 0.05mm (Conforming to IS 280-2006. Core diameter of the vertical wire : 4mm + 0.05mm. Tensile strength of wire : 550 N/Sqmm. Mesh size : Distance between horizontal wire : 12.7mm. Distance between vertical wire : 76.2mm. (subject to tolerance in accordance with EN 10223-7, EN10245-1). Welding strength : The average weld shear strength of 4 welds taken at random shall not be less than 50% of breaking strength of vertical wire (EN-10223-7). Zinc coating : 40-50 GSM (100% zinc) (conforming to IS 4826-1979).Powder coating: After welding the panels shall be polyester powder coated in single layer of thickness 60-80 micron in green colour RAL 6005 and shall withstand 1000 hours of salt spray test. Reference drawing: WM-WC-0417-S-377 dt 01.04.2017. Wire tensile strength : Min 550N/Sqmm Weld Strength : The average weld shear strength of 4 welds taken at random shall not be less than 50% of the breaking strength of the vertical wire Powder Coating :EN 13438- 2005/IS13871- 1993
(Note: Supply of omega clamps with profile cover plate will be measured separately under respective item. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
Circular hollow MS steel Tube (IS-1161), 76mm Dia, 3.2 mm thickness (+10% tolerance), 3345mm long (+5% tolerance) (2745 mm above ground level + 600mm under the ground level), each weighing 20Kg (± 5% tolerance) hot dipped galvanized to minimum 350 GSM as per IS 2629/IS 4759/ASTMA 123 as in fence posts, complete all as shown in drgs, specified and as directed. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
Supply only Omega clamps with profile cover plate to tighten the mesh panel along the posts with diameter 76mm, 35 mm width and 3mm thick flat-35mm width, 3mm thick (MS strip as per IS 1730) hot dipped galvanized to minimum 350 GSM as per IS 2629/IS 4759/ASTMA 123 (7 Nos per post). Each clamp will be supplied with a pair of SS 304 mushroom headed, square necked bolts and security nuts M8x50 (IS 8535-1987) each set of Omega clamps including weight of SS-304 security Nuts, shall be weighing 0.66Kg (± 5% tolerance), complete all as specified and as directed. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
Supply & fixing STRAINING Y- ARM : Straining 'Y'- Arm shall be of mild steel angle iron of size 50mm x 50mm x 5 mm (IS-1730), 750mm length, each one of hot dipped galvanized to 350 GSM as per IS 2629 / IS 4759/ASTM A 123, each Y-arm weighing 6.75 Kg (+/- 5% tolerance), with 63mm outer dia of sleeve cap, bolted as in straining Y- arm on the top of the fence post at every 30m distance fitted with stainless steel mushroom head bolt with breakable head safety nut (M8 x 120) (2 No per post) each set of SS-304 security Nuts, weighing 0.168Kg (± 5% tolerance), complete all as specified and as directed. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
10mm dia 250mm long GI anchor rod, each weighing 0.155Kg (± 5% tolerance) to tie with fence post at bottom using tie wire (2 Nos. for each post) complete all as shown on drawings and as directed. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
High tensile heavy galvanized mild steel wire for line wire & high tensile barb wire made of high carbon steel approximately 0.28%, line wire diameter shall be 3.15mm with 2mm dia barbs at 100mm spacing conforming to (IS 4826-1979) zinc coating 290 GSM, tensile strength 1450-1650N/Sqmm, barb wire diameter 2mm zinc coating 240 GSM, tensile strength 450-600 N/Sqmm, barbing pitch : 100mm, barb type : 4 point IOWA style, per 100m weighing 9.80Kg (± 5% tolerance) Strands : Single (6 row). straining and fixing to Y-arms straining bolts, including and tying at crossings with and provision of galvanised mild steel wire, staples steel pieces etc., complete all as shown on drgs and as directed. (each line wire to be measured separately). Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
Punched type concertina coil as per latest IS 6745-1972 with galvanised coating and punched type material as per IS deep drawn quality with galvanised coating having medium barbs fixed in position and secured to fence posts/straining Y- arm stretched to a length so as to achieve 1050 mm dia as in fencing including fixing with special galvanised fastners such as J clips, C clips, U clips fixed at any height of security fence including necessary scaffolding complete all as shown in drgs and as directed. Size of Coil : 1050mm dia/56 loops/2.5mm core wire. Type of strip : Heavy galvanised conforming to IS 1730 (1989). Type of core wire : Heavy galvanised conforming to IS 280-2006.Zinc coating to strip : 200GSM/Sqmm Zinc coating to line wire : 275 GSM/Sqmm (IS 6745- 1972 Reprint 2006)Tensile strength of wire : 1400-1500 N/Sqmm. Weight : 14.63 Kg/coil (± 5% tolerance). Blade : 22mm Barb profile: Medium blade (MBBT). Distance between barb : 35mm Stretchable length of each coil : 12m Type of clip : Hardened galvanised steel. Manufacturer/Fabricater: M/S A-1 Fence Products Company Pvt Ltd Mumbai/Global Technocrate PVT Ltd or equivalent as approved by the GE.
Concertina coil 600 mm dia, 56 loops, 2.5mm core wire, heavy gavanised (wire-275 GSM & strip-200 GSM), tensile strength of wire-1400-1500 N/Sqmm, weight 6-8Kg/coil, (± 5%) stretchable length- 6m to 8m including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete, all as specified and as directed. Make: M/S Global Engg, M/S Special steels Ltd, M/S Super Fence. Note: Weight per RM of concertina coil shall be ascertained by B.O.O to be appointed by the CWE. Notes : (Applicable to Srl item No. 8.00 to 15.00 here-in-before) a) The contractor shall within 15 days of the placing of work order, intimate to GE the name of manufacturer meeting below specified criteria (documents such as copies of supply orders, Invoices of materials supplied, in support thereof shall be produced) for the materials under Srl items No. 8.00 01 to 15.00 in writing for his approval after due verification of the credentials of manufacturer for these products. The manufacturer as approved by GE shall be in possession of NSIC/MSME registration for manufacturing and supplying composite fencing system using Weld mesh panels, Fence Posts, accessories and razor wire coils as specified vide above mentioned respective item with in-house plant and machinery for manufacturing and polyester powder coating as well as thermo plastic coating as per specifications for coating.
Note:(Applicable to Srl item No. 8.00 to 15.00 here -in- before) (i) The Manufacturer Should be manufacturing and supplying composite fence system Weld mesh panels, Fence Posts, Accessories and Razor wire coils for a minimum three years period. (ii) The Manufacturer should have manufactured and supplied an average of at least 300MT per year of similar high security weld mesh panels in the last three Years. (iii) The Manufacturer should have manufactured and supplied an average of at least 100MT per year of similar fence posts and accessories in the last three Years. (iv) The Manufacturer should have manufactured and supplied an average of at least 250MT per year of similar Razor wires/Coils in the last three Years. (v) The manufacturer shall provide type test certificate for Sample testing of 1000Hrs of Salt Spray Test from a renowned NABL approved Lab towards Powder Coating of materials manufactured by them.
Note:- (Applicable to Srl item No. 8.00 to 15.00 here -in- before) (b) Irrespective of whatever specified towards testing of materials in the tender documents production of test certificates by the contractor from the manufacturer is mandatory towards materials procured against Srl items 7.01 to 7.08 here-in-before. To ensure the materials brought to site for incorporation in the work conform to testing parameters specified, Frequency of independent random testing of the materials under serial item No 7.01 to 7.08 shall be as per relevant code of practice subject to a minimum of one sample from each lot of materials manufatured (in case the materials procured are from different lots manufatured) one sample per 1000m length of fence (in case all the material is manufacutred in one lot). Independent testing shall be got carried out by the GE from NABL Labs for materials against Srl items 7.01 to 7.08 here-in-before. The cost towards testing charges, transport and handling shall be borne by the contractor within the rates quoted against said items and nothing extra shall be admissible on this account.
Note:- (Applicable to Srl item No. 8.00 to 15.00 here -in- before) (c) The contractor shall submit warranty for a period of 24 months from the date of certified completion.
Taking down/dismantling Loopin\Loopout junction box fittings Including electric connections from security poles and set aside for refixing of serviceable junction box complete all as directed
Fixing only Loopin\Loopout junction box fittings Including elect connections complete all as directed Note:- PVC cable 1.5 Sqmm, three core, required for electric connection shall be mesured and paid separately.
Loop in/loop out cable, juntion/terminal box for cable connection made out with thermoplastic of size 200mm x 160mm x 98mm along with 200 Amp rated bus bar and MCB SPN 6 Amps 230 Volts with provn of external fastening with metric knockouts for cable entry & outgoing for service connection to security light complete, all as specified and as directed. Make: Hensel/Sintex /Universal switch gear control
Fixing only GI brackets Including clamps and necessary nuts,bolts and washers etc complete all as directed
GI tube light grade 20mm dia, 6 meter long sutable for 1.5 sqmm, 3 core cable of length 7 meter from looping box to street light connector, holding in MS clamp of size (25X2)mm thick at every one metre used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc and including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to security light fitting connector, complete all as specified and directed.
Taking out HT/LT Cables of any size in any position complete all as specified and directed. Note:- Earth work will be measured and paid separately under respective items.
Laying only LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross section area 10 sqmm, 4 core and testing commissioning, complete all as per directed by Engr - in- Charge
Laying only LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross section area 16 sqmm, 4 core and testing commissioning, complete all as per directed by Engr - in- Charge
Laying only LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross section area 25 sqmm, 4 core and testing commissioning, complete all as per directed by Engr - in- Charge
Laying only LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross section area 35 sqmm, 3.5 core and testing commissioning, complete all as per directed by Engr - in- Charge
Laying only LT cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, cross section area 50 sqmm, 3.5 core and testing commissioning, complete all as per directed by Engr - in- Charge
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 10 sqmm, 4 core, complete all as specified and directed
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 16 sqmm, 4 core, complete all as specified and directed
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 25 sqmm, 4 core, complete all as specified and directed
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 35 sqmm, 3.5 core, complete all as specified and directed
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 50 sqmm, 3.5 core, complete all as specified and directed
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of cross section area 95 sqmm, 3.5 core, complete all as specified and directed
Supply and fix cable jointing kit for 1100V grade cable for straight through joint complete, heat shink type joint complete with jointing material and accessories suitable for 3.5 core or 4 core XLPE, armoured, aluminiuml conductor cable of size 25 Sqmm to 35 sqmm, complete all as specified and directed
Galvanised steel wire 3.15 or 4mm dia, complete all as specified and directed
Earthing complete with steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1,5 metres below normal ground level,connecting to the Galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and steel earthwire protected by provision of GI Medium grade pipe 15 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 17mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25 x 25 x 6 mm with lugs 02 No and with 6 mm dia MS bar handle made to shape GI medium grade 20 mm bore pipe for watering perforated at bottom, 1.75 metere long placed on top edge of earth plate, common salt and charcoal fittings, test point made out of 17 mm x 8 mm FI with fixing arrangement, funnel wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 M all as per electrical plate No 5 of SSR Part- I connected to earth test point all as specified or indicated including testing on completion, complete all as specified and directed
Earthing complete with galvanised steel earth plate elcrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground) with top edge of plate not less than 1.5m below normal ground level connecting to the GI earthing strip 32x6mm by means of bolts, nuts check nuts and washers of galvanised iron and GI Strip 32x6mm protected by provision of GI Light grade pipe of 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregrate with 40mm thick cover of RCC (1:2:4) raniforced with XPM (weight not less than 4Kg/sqm) and frame of angle iron 25x25x6mm with lugs 02 nos and 6mm dia MS bars handle made to shape, GI Light grade 20mm bore pipe for watering perforated at bottom 1.75m long placed on top edge for earth plate incl common salt and charcoal filling, test point made out of 75x50x6mm phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50m all as per electrical plate no 3 of SSR 1991 Pt-I and connecting to earh test point incl testing on the site, complete all as specified and directed
Construction platfrom size 3mx2mx1.2m with brick masonary CM (1:6) including 15 thick plastering in CM (1:4) in all sides with plinth protection of length of 60 cm arround and brick steps with plastering in CM (1:6) with XPM fencing 1.2 mtr height with weight not less than 4 Kg per Sqm and angle iron 50x50x6mm and two coat of aluminum paint over one coat of red oxide with synthetic enameled pain for supports gate with locking arrangement and PCC floor in cement concrete 1:2:4 type B1, 50 mm thick including filling all as specified and as directed . from ground including wire netting with angle size 50x50x6mm including steps, plinth protection and all other relevant works including dismantling old unserviceable platform, complete all as specified and shown on drawing No. CEUZ/TD-1129/96 sheet 1/2 & 2/2.directed.
Taking/ dismantling all conections from HT/LT side of transformer and Shifting of transformer on newly constructed platform site as specified and refixing of all electric connections complete all as specifed and directed.
Taking down/ dismantling security light fittings Including GI brackets from external security poles and set aside for refixing of serviceable security light Fittings complete all as directed.
LT switch gear control panel board 440 volt AC 3 phase, 4 wire for out door installation " KIOSK TYPE" with sloping canopy fabricated out of steel sections i.e., CRCA sheet 3.15mm thick, angle/channel and flat iron sections of suitable size with opening on front, door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 54 standard with phosphatised powder coating painting externally and internally to protect against corrosion. The panel shall be mounted on suitable size of channel section having ground clearance 60 cms from grouting bolts, complete duly incorporated with following accessories :- (i) Bus bar chamber with electrolytic grade aluminium strip with heat shrinkable sleeves with colour code supported on epoxy resin based insulators 4 strip of suitable length for current rating min 375 Amps (ii) MCCB 4 pole 415 VAC, current rating 250 Amps breaking cap 25 KA at 415 volts= 01 No (Incoming).
(iii) MCCB 4 pole 415 VAC, current rating 160 Amps breaking cap 25 KA at 415 volts= 02 No (outgoing) (iv) MCCB 4 pole 415 VAC, current rating 63 Amps breaking cap 16 KA at 415 volts= 02 No (outgoing) (v) Voltmeter digital type 0-500 V, 96mm square flush panel mounting =01 No ( on incomming supply) (vi) Ammeter digital type 0-200 A, with CTs of suitable ratio, 96mm squre flush panel mounting=01 Nos (on main load) (vii) Indication pilot light to operate on direct supply 230 V AC with 2.4 watt bulb (R, Y, G) with smooth lens=03 Nos (viii) On load changeover (manual type) of capacity 200 Amp 4 pole=01 No (ix) Current transformer (bar primary low tension) type CBF-0.6-D1 ratio 200/5, 15VA accuracy class-1 = 01 No (Set of three) (x) Complete wiring of panel board with FRLS PVC insulated multistranded copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers, complete all as specified and directed
Supply and fixing and testing of Aerial bunched cable (AB) HT 11KV of size 3 core x 95 sqmm+1 core x 70 sqmm with Three power cores stranded compacted circular alluminium conductor screened with black extruded semiconducting compaund, natural colored XLPE insulated core screened with black extruded semiconducting compaund and one layer of copper type and covered with black extruded PVC (core identification by colour tape marking red, Yellow and blue with colour tape placed longitudinally under the copper tape) and one bare messengar wire shall be stranded non compacted cicular alluminium alloy conductor , all as specified and directed. Note:- The following hardware fittings and accessories shall be used to install,erect and join the AB cable (i) Suspension clamp with eye hook (ii) Suspension fittings and corresponding eye hook (iii) Dead eye fittinngs (iv) Nylon Tie (v) connectors
Making holes by drilling or by any other mechanical means, dia of bore hole not exceeding 50mm and 300mm deep including supply & fixing of anchor rod 25mm dia TOR steel with and including epoxy grout in bore hole below bottom of foundation of column in hard rock complete all as specified and as shown on drg.
HDPE DWC pipe (double wall corrugated) outer dia 80mm & inner dia 68mm confirming to IS: 16098 alongwith necessary snap fit coupler for interconnection, laid in trenches or fixed to wall, complete all spedified and directed.
HDPE DWC pipe (double wall corrugated) outer dia 50mm & inner dia 38mm confirming to IS: 16098 alongwith necessary snap fit coupler for interconnection laid in trenches or fixed to wall, complete all spedified and directed.
Deduction to be made from BOQ for Sch 'A' Part - VIII (Schedule of credit) Amount of Rs. 21,52,409.50 during AOC. Note: Tenderers shall not quote for this schedule.
M/S MOOL RAJ SHARMA (BID ID -3054749)
M/S BHATIA BUILDERS AND CONTRACTORS (BID ID -3057825)
RSP Contractors India Private Limited (BID ID -3055085)
Chandra Construction (BID ID -3057308)
SATVIR GUPTA ENGINEER and CONTRACTOR (BID ID -3058103)
JINDAL BUILDERS (BID ID -3054824)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
145691645.pdf
Tender Document • 0.41 MB
145691647.html
Tender Document • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .