Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹22 L
EMD Value
₹46,500
Closing Date
26 Oct 2023, 10:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
Uday Kumar M H
Installation of suitable capacitor for functioning of 2nd motor and servicing of outer braker switch gear and power transformer at Rajanahalli pumphouse and also installation of mini himast for purpose of lighting system and servicing of transformers in DCC limits
DMA/2023-24/EL/WORK_INDENT4995
DMA/2023-24/EL/WORK_INDENT4995
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Davanagere
3 documents required · 3 mandatory
₹550
₹46,500
12 Oct 2023
12 Oct 2023
25 Oct 2023
Installation of suitable capacitor for functioning of 2nd motor and servicing of outer braker switch gear and power transformer at Rajanahalli pumphouse and also installation of mini himast for purpose of lighting system and servicing of transformers in DCC limits
OVERHAULING OF VCB:- Rackout from the faulty breaker from 11KV MCVCB panel dismentling the operating Mechanism, cleaning all mechenism with cleaning solution ,checking the fixing and moving contacts, ...
Spare compnents for VCB Repair:-a)Spring charging mechanism bearing
Spare compnents for VCB Repair:-b)Loaded spring for spring chrging unit
Spare compnents for VCB Repair:- c)Bush bearing of spring charging motor
Servicing of outdoor 11KV VCB Panel - Cleaning all close contact,tripping contact, & cheking the control wiring & rewiring wherever necessory with suitable size copper multy stand flexible wire,ferrul...
Spares Servicing of outdoor 11KV VCB Panel ;- a)Supply & fixing of 3over cuurrent/earth fault relay, control voltage 110VDC.REJ-601/REM-601
Spares Servicing of outdoor 11KV VCB Panel ;- b)Supply & fixing of Master trip relay, control voltage 110VDC.
Spares Servicing of outdoor 11KV VCB Panel ;- c)Closing coil 110DC
Spares Servicing of outdoor 11KV VCB Panel ;- d)Trippinng coil 110VDC
Spares Servicing of outdoor 11KV VCB Panel ;- e)Make &break Limit switch
Spares Servicing of outdoor 11KV VCB Panel ;- f) Breaker control TNC Switch
Spares Servicing of outdoor 11KV VCB Panel ;- g) 24pin plug & socket
a)Earthing:- Providing earthing as per latest ISS 3043 and as per IE rules including the following. a) Earth Electrodes FOR LT System :- supplying, fixing , wiring , earth electrode for grounding usin...
Earthing:- Providing earthing as per latest ISS 3043 and as per IE rules including the following.b)supplying laying & jointing of 25/6mm GI Strips for equipement connection
3.3 KV Indoor Switch gear: Supply and delivery at site brand new Cromton make cubical type dust and vermin proof horizontal drawout type,VD4 type Vacuum circuit breaker, 3.3 KV, 50 HZ, 75 MVA, 18.1 KA...
3.3 KV Indoor Switch gear : Erection,Testing &Commisioning of VD4 VCB in buscoupler panel with necessory modification work & required conrol wiring work
1000HP 3.3KV Motor feeder:- Supply,erection,testing & commissioning of 400A Vaccume Contactor alongwith Suitable busbar, busbar suporting insulator suitable KV, HT Insulating sleeves, necessory steel ...
supply,erection testing & commissioning of 3.3KV 340KVAR Capacitor panel along with required rating Load break switch, series reactor 0.2%,& CBCT with ELR
a)Repair/Servicing of DCDB Panel the work including of rewiring the power &control wiring, replacing corroded crimping type lugs.ferruls,bolts,nuts & washers etc complete.
b)Replacing of fauly/damaged 6A DCDPMCB's in DCDB including fixing testing & commissioning.
a)Repair/Servicing of ACDB Panel the work including of rewiring the power &control wiring, replacing corroded crimping type lugs.ferruls,bolts,nuts & washers etc complete.
b) Replacing of fauly/damaged 6/16A DPMCB's in ACDB including fixing testing & commissioning.
a)Battery bank servicing:- replacing & servicing of damaged cell interconnected link, non ferus bolt, nuts & washers etc complte.
b)Supplying ,filling of diluted sulphuric acid (electrolite) for filling the al 55 Nos of existing batteries at 110V Bank (Approximatly 150 Liters) including 10percent spare1.300sq.gr at27degree C" (M...
Servicing of Battery Charger the work includes replacing of damaged spares such as sutable rating HRC Fuses,control chord,UV/OV Relay, DC Over load relay,& suitable amps MCB's
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
22L Pump house.doc
Tender Document • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .