Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 May 2024, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
REPAIRS TO ROOF SHEET, ROOF TREATMENT, EXTERNAL PLASTERING AND OTHER MISC WORKS OF OTM / MD ACCN IN IB LINE AND INSIDE OF AGE B/R-I UNDER GE GOLCONDA
2024_MES_648765_1
8769/E8
Open Tender
Civil Works
Item Rate
270 days
HYDERABAD
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCONDA
₹80,000
Yes
8 May 2024
1 Apr 2024
6 May 2024
1 Apr 2024
4 May 2024
24 Apr 2024
Amount
Dismantiling of AC sheets / Galvolume sheet / GI sheet Corrugated or Semi corrugated etc in roof coverings.
M &L 6 mm thick Asbestos Cement sheet corrugated or semi corrugated in roofs, walls etc and fixed with J or L hook or cranked bolts with washers etc. complete all as specified and directed.
Fixing only 6 mm thick Asbestos Cement sheet corrugated or semi corrugated in roofs, walls etc and fixed with J or L hook or cranked bolts with washers etc. complete all as specified and directed. Note: Sheets obtained from item No. 1 shall be used.
M & L for asbestos cement two pieces adjustable serrated ridge for corrugated and semi corrugated sheet 6mm thick fixed with J or L hook and cranked bolts woth washers etc. complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating steel corrugated sheet 0.45mm to 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed Note: Rate quoted deemed to include cost of making good disturbed masonry surface to match with existing etc using PCC 1:2:4/cement mortar 1:4 complete all as specified and directed.
All as per item no 5 above but fixing only obtained from serial item no 1.
M&L pre- painted galvalume aluminum zinc coating plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L Taking down existing felt roof treatment, screed bed and preparing the surfaces of roof by cleaning off foreign materials with water, roughening surfaces of old concrete and washing down with water to remove dust, providing cement mortar screed 10mm thick on concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound, laying APP based polymeric membrane minimum weight 3Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/Sqm) over primed surface with bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by torch application, 10cm overlap fused uniformly by LPG torched flame and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm finished with one coat of aluminium paint @ 100ml/Sqm, , complete all as specified and directed. Note: 1) Water proofing compound shall be measured and paid separately. 2) Padding concrete where required shall be measured and paid separately. 3) The quoted rate include for taking down existing tank and refixing the same in its position.
M&L for Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed.
S&F Plain, galvanised, mild steel sheeting 0.8 mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M & L for applying glass fibre base bitumen felt, grade 2 over bitumen primer applied @ 0.3 Lit/Sqm on ridge portion of corrugated sheeting/ mangalore tile roofing etc including taking out existing felt complete all as specified and directed.
M&L for providing cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in padding and benching & filletting mixed IWPC (IWPC measured and paid seperately) complete all as specified and directed.
Supply only integral water proofing compound.
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed
Dismantling Single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed
M & L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
M&L ceiling tiles or slate roofing for Mangalore tile roofing, laid dry complete all as specified and directed
Dismantling battens for tiles, shingles etc of any size including tilting fillets exc 15 cm centre to centre complete all as specified and directed
M & L for Clean sawn battens at 30 cm centres size exc 15 Sqcm and not exc. 25 sqcm in 2nd class hard wood complete all as specified and directed
M & L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed
Dismantling timber scantlings 40 Sqcm and over in section in any position in framed work.
M & L for 2nd class hard wood, clean sawn as in scantiling timber fixed with nails complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not other wise provided for.
S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed.
Dismantling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all as specified and directed
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed suface with precoated capping, main tee and cross tee of size 24x32mm at every 1200mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 2mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear size aluminium foil and front side PVC lamination, complete all as specified and directed.
S&F in repair 40mm bore dia Gun metal Gate valve with iron wheel head screwed both ends for iron pipe or for union, complete all as specified and directed.
S&F GI tube 40mm dia medium graded with all fitings and fixed to wall, celing or laying in trenches including taking up and down complete all as specified and directed
S&F 500 Ltr capacity tripple layers rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position including dismantling existing tank complete all as specified and directed.
S&F 1000 Ltr capacity tripple layers rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified including dismantling existing tank complete all as specified and directed.
S&F 2000 Ltr capacity tripple layers rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified including dismantling existing tank complete all as specified and directed.
S&F in repair Ball valves 25 mm dia high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms)
S&F in repair 20mm bore dia Gun metal Gate valve with iron wheel head screwed both ends for iron pipe or for union, complete all as specified and directed.
S&F in repair 25mm bore dia Gun metal Gate valve with iron wheel head screwed both ends for iron pipe or for union, complete all as specified and directed.
S&F in repair Cover/ lid for PVC water tank of any capacity complete all as specified and directed.
S&F GI tube 25mm dia medium graded with all fitings fixed to wall, celing or laying in trenches including taking up and down existing GI tubing complete all as specified and directed
S&F GI tube 20mm dia medium graded with all fitings and fixed to wall, celing or laying in trenches including taking up and down existing GI tubing complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed
M & L half Brick wall with sub-class 'B' bricks old size straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed
Taking down cement plaster any description on brick or stone walls, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for 10mm thick in CM 1:6 rendering on brick or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
M&L rendering 15mm thick on brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement with WPC (WPC measured separately) complete all as specified and directed
M&L for Rendering 5mm thick in CM 1:3 as in ceilings concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
M&L for three coats of white wash on new surfaces of walls including preperation complete all as specified and directed
M&L preparing newly plastered surfaces and applying two coats of OBD over a coat of alkali resistant primer on walls complete and all as specified.
M&L for three coats of Colour wash on new surfaces of walls including preperation complete all as specified and directed
M&L for two coats of cement base paint on walls including preparation of surfaces complete.
M&L for three coats of white wash on ceilings including preparation of new plastered surfaces complete all as specified and directed
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n exc. 15cm thick (Below or above ground level) complete all as specified and directed
M&L for Plain cement concrete C-2 type 1:3:6 (40mm graded aggregate) 75mm thick as in plinth protection complete all as specified and directed
S & F PVC( SWR ) pipes 110mm dia single socketed , in any length with rubber ring joints as rainwater, soil waste and vent pipe fixed to wall or laid in trenches incl taking down existing pipes (including fittings) complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F PVC (SWR) branch piece single ( Single Y) equal or un equal with access door of bore 110 mm complete all as specified and directed.
S&F grating doom 100mm dia of PTMT (minimum weight 25gms ) complete all as specified and directed.
M&L for Preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coates of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M/s Amit Associates
harshraj and co
Sri Lakshmi Enterprises
SM CONSTRUCTIONS
PVRCS ENGINEERS
Dwarka Pershad Radhey Ramanlal
M/S Veerabhadra Constructions
rahi consultant
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .