Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹29.3 L+₹1.2 L (4.11%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹32.0 L+₹3.9 L (13.7%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹39.1 L+₹11.0 L (39.3%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L4 | Rejected-AOC NOT LOWEST |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
SPL REP TO LT UG CABLE OF SH 01 TO 11 AT WED EXTN OF WATER PIPE LINE AND REPLACEMENT OF EXISTING DETERIORATED PIPES AT VARIOUS LOCATIONS AT INS TANAJI SPL REP TO COVERING OF SHALLOW WELLS 04 IN NO AT NAD AND CERTAIN MINOR WKSUNDER GE (NW) MANKHURD
2019_MES_307043_3
8949/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹75,000
Yes
3 Mar 2020
7 Feb 2020
26 Feb 2020
7 Feb 2020
24 Feb 2020
19 Feb 2020
7 Feb 2020 - 18 Feb 2020
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sq mtr on plan and getting out in in any type of soil complete all as specified and directed.
Returning filling in, including spreading, leveling and well ramming in layers not exc 25cms each any type of soil complete all as specified and directed.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point complete all as specified and directed.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently punning down manually as in cable protection all as specified and as directed. Note : Sand after punning down will be measured
Supply and laying un-reinforced precast concrete cable cover class LV ISI Marked, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6 type C-2 using 40 mm graded aggregate including removal of surplus soil complete all as specified and directed
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armoured heavy duty aluminum conductor LT 1100 Volts grade of size 3.5 core 400 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting complete all as specified and directed. Note - Excavation and earth work will be mesured and paid separetly.
All as per item No 7.00 above but of size 3.5 core 150 sqmm
All as per item No 7.00 above but of size 3.5 core 120 sqmm
S& F HDPE pipe 100mm dia for laying in ground, road crossing etc for cable protection including necessary fittings , clamps for supports, etc complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade, cross sectional area 400 sq mm 3½ core.Including cable lugs of suitable size complete all as specified and directed.
All as per item No 11.00 above but of size 3.5 core 150 sqmm
All as per item No 11.00 above but of size 3.5 core 120 sqmm
S & F in replacement of MCCB TPN 500Amps, 50KA, 415volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed.
Supply install, test and commissioning of Powder coated LT Feeder panel cubical out door type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, incoming MCCB and TPN Copper bus bars of suitable size, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The connecction between Bus Bar & MCCB should be done by copper bus bar link. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm a detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables & Reconnecting the cables to new panels and including PCC foundation, excavation, grouting bolts. a) Copper bus bar 1200 Amps for 3 phase and Neutral b) MCCB TPN 500 Amps 415 Volt 50 KA - 1 Nos c) MCCB TPN 315 Amps 415 Volt 50 KA - 1 Nos d) MCCB TPN 200 Amps, 415 Volt 36 KA - 4 Nos e) RYB Indicators - 01 Set Note - The lay out drawing of the panel shall be got approved from the GE by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer
Taking down of old broken/unserviceable MS angle irons /sheet/nut ,bolts/clamps/coverings of open wells all as specified and as directed
Supply and fix steel frame work made out of suitable size MS angle iron/ISMB/sheet /flate iron clamps, nut, bolt etc fixed by welding cutting, cut to shape, drilled and countersunk for screw, including bending and welding angles as required as per FE-410 complete all as specified and directed.
S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed. Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S & F aluminium anodised grill DG-104/DG-102 10 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building etc complete all as specified and directed.
Supply and fixing aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm & fixed with aluminium wire staples complete all as specified and directed.
Cutting into old masonry to form toothings for and bonding in new brick or stone work including making good in cement mortar
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 etc completed all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 20 mm to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses for granite or trap stone complete all as specified and directed.
M & L for PCC 1:2:4 type B1 20mm grading in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M & L for internal surfaces rendering 15mm thick in CM 1(:4) on fair faces on stone masonry surfaces or surface finished with using extra cement and integral WPC etc complete all as specified and directed Note-: Integral WPC will be measured and paid seperately.
M & L for external surfaces rendering 20mm thick in CM (1:6) on fair faces on stone masonry surfaces or surface finished as sand face finish with using integral WPC etc complete all as specified and directed Note-: Integral WPC will be measured and paid seperately.
M & L for top surfaces of coping rendering 20mm thick in CM (1:3) on fair faces on concrete surfaces or surface finished as sand face finish with using integral WPC eetc complete all as specified and directed Note-: Integral WPC will be measured and paid seperately.
M & L of preparing newly plastered surfaces and applying 3 coat of white wash on wall complete all as specified and directed.
M & L of preparing newly plastered surfaces and applying two coat of cement base paint over one coat cement primer etc complete all as specified and directed.
Supply only integral WPC
Cutting of existing GI pipe of size 40mm dia and inserting GI tee/bend including all required new fittings complete with testing,all as specified and directed.
Supply, lay/fix, connect and testing steel water tubing of 40 mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures,Clamps and fixed to wall/ceiling or laid in trenches/floors complete all as specified and directed.
All as per item No 32.00 above but of size 25 mm
All as per item No 32.00 above but of size 20 mm
Supply & fix in repairs, connect and testing steel water tubing of 40 mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures,Clamps and fixed to wall/ceiling or laid in trenches/floors complete all as specified and directed.
All as per item No 35.00 above but of size 25 mm
All as per item No 35.00 above but of size 15 mm
S&F 40 mm dia gunmetal gate or globe valve, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed
All as per item No 38.00 above but of size 25 mm
All as per item No 38.00 above but of size 15 mm
S&F in repairs 40 mm dia gunmetal gate or globe valve, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed
All as per item No 41.00 above but of size 25 mm
All as per item No 41.00 above but of size 15 mm
Supply, fixing, testing and commissioning hi wall 1.5 ton split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.80 of capacity 1.5 Ton electric driven single phase 230 Volt including provision of copper tube of suitable size and length as required at site complete all as specified and directed. Make :- Hitachi RAU518EUDA or Equivalant of Voltas/LG/Blue Star
Supply and fixing earthed metal clad socket outlet with earthed plug top 20Amp capacity , sheet metal enclosed and one 20 Amp MCB SP all as specified and directed.
M&L for sub main wiring with two single core 4 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade drawn in & including through rigid flexible where applicable non metalic PVC casing caping with and including PVC FRLS insulated 2.5 Sqmm single core multi-stranded flexible copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : Two runs of 4 Sqmm single core cable, one run of 2.5 Sqmm earth wire and one run of PVC casing caping will be measured & paid one unit
M & L for point wiring with FRLS PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws specified and directed
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type complete all as specified and directed
Supply & fix pedestal fan 450 mm sweep star rated along with blade, canopy, mounting brackets, rubber insulator. The colour of fan shall be of grey and conforms to Model no PF S Storm 2 of Crompton or Equivalent from Orient, Bajaj complete all as specified and directed.
Supply & fix wall mounting fan 450 mm sweep star rated along with blade, canopy, mounting brackets, rubber insulator. The colour of fan shall be of grey and conforms to Model no WM HIflow LG 18" -of Crompton or Equivalent from Orient, Bajaj complete all as specified and directed.
Supply and install water cooler fully stainless steel, electric driven single phase having approximate storage capacity of 120 Ltrs and normal cooling capacity of 80 Ltrs per hour with and including raised platform of PCC (1:3:6) type C-2 of suitable size for placing and drain system etc complete all as manufacturer’s specifications and instruction and as directed all conforming to Cat No of Blue Star 120 Litre Water Cooler [SDIx 8120] or equivalent from Voltas/USHA complete all as specified and directed.
M&L for sub main wiring with two single core 2.5Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volt grade PVC insulated and unsheathed drawn in & including through rigid flexible where applicable non metalic PVC casing caping with and including PVC insulated FRLS 1.5 Sqmm single core multistranded copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : Two runs of 2.5 Sqmm single core cable, one run of 1.5 Sqmm earth wire and one run of PVC casing caping will be measured & paid one unit
Supply and fix refrigerator, electric driven (single phase), capacity more than 195 Litres BEE 5 star rated all as specified and directed.
Supply installed and testing of Split Air Conditioner vertical electric driven Three phase with all standard fittings of capacity 2.5 TR cooling capacity (30000 BTU/Hrs having energy saving star rating not less than 4 star) Make Blue Star Model No-VCE-301 SC or equivalent make specified in PS with Indoor Unit having moisture removal of 2.6 ltrs/hr complete with Cordless Remote. Out door unit having Scroll type of Compressor with 5/8" copper suction line and 3/8" copper liquid line and all as specified and directed.
S & F triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 32 Amps complete all as specified and directed
S & F MCB TP 32 Amps, 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified and directed
M&L for sub main wiring with two single core 6 Sqmm FRLS multistranded flexible copper conductor cable 660/1100 volt grade PVC insulated and unsheathed, drawn in and including heavy grade PVC casing capping with all accessories etc as required, including one run of 4 sqmm PVC insulated multistranded unsheathed copper conductor cable as earth continuity conductor, duly connected to common earth dolly all as specified and directed. Note :- 1. Two runs of 6 sqmm Single core cable, one run of 4 sqmm earth wire & one run of PVC Cassing Capping will be measured and paid one unit. 2. A sum of Rs 64,940.00 towards sch of credit shall be deducted to arrive the contract sum.
Parmatma Enterprises
joshua construction
Joy builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .