Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | ₹19.5 L | L1 | Accepted-Finance Being L1 |
| 2 | L2₹19.9 LRejected-Finance LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | ₹19.9 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹21.6 LRejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | ₹21.6 L | L3 | Rejected-Finance Being L3 |
Tender Value
₹23.4 L
EMD Value
₹46,900
Closing Date
5 Mar 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer Pwd R and B Gandhi Nagar I/c UWD
Construction of second floor over existing building of Centre for IT and Enabled services and Management Electrical work
2026_UDJK_303816_1
enit 155 dated 13-2-26
Open Tender
Electrical Works
365 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
Executive Engineer Pwd R and B Gandhi Nagar I/c UW
₹46,900
13 Mar 2026
19 Feb 2026
9 Mar 2026
19 Feb 2026
5 Mar 2026
19 Feb 2026
Part-A (Sanctioned Schedule items) Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with modular type switch,modular plate and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab Conduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge (Group ‘C’)
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia
Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/KEI/polycab Equivalent make of required specification to be approved by the Engineer In charge ) i. 2x1.5 +1x1.5 Sq mm
i. 2x2.5+ 1x2.5 Sq mm
ii. 2x6 +1x6 Sq mm
iv. 4x6+ 2x6 Sq mm
iv. 4x10+ 2x6 Sq mm
Supply & fixing 3 pin 5/6 amp Modular type socket outlet on the existing switch box or cover including connection as required(Make: Havells/ Anchor /Sanchi major/)
Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) i 1x1.5 sqmm
ii.2x6 sqmm
Supplying & drawing following 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel / PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI)
Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T Equivalent make of required specification to be approved by the Engineer In charge) 1 run of cable
P/f of 25X5mm G.I strip on surface/in recess for connections as reqd.
Providing and fixing lighting conductor finial, made of 25 mm dia 300mm long G.I tube having single prong at top, with 85mm dia 6mm thick G.I base plate including holes etc. complete as required.
Providing and fixing G.I tape 20x3mm thick on parapet on surface of wall for Lighting conductor complete as required ( for horizontal run)from earth electrode as required.
Providing and fixing G.I tape 20x3mm thick on parapet on surface of wall for Lighting conductor complete as required ( for vertical run)from earth electrode as required.
Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_986797.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid