| Sl No | Description | Qty | Unit | ELECTRO POWER L1 |
|---|---|---|---|---|
| 1.00Supply and installation of motor protection relay in different places under Pandaveswar Area . (Inclusive of EPF/CMPF) | ||||
| 1.01 | SUPPLY AND FITTING OF(LT) MOTAR PROTECTION RELAY(Advance current based motor protection relay with multi protection and monitoring in compact,
modular and smart 35mm din-rail enclosure. It should be a fully digital with seven segment display based on microprocessor technology with analogue to digital conversion of the measured values. The relay must have feature Over Load (50-150%) with Definite curve (0.01-60sec)/Inverse Curve Tripping Class (5-60), Short Circuit (200-800%), Under Current (20-90%),Unbalance(5-50%), Phase Loss, Phase Reversal, Stall(150-600%), Locked Rotor (200-1000%),Earth Fault[Residual(10-50%)/CBCT(30mA-3000mA)], Circuit Breaker Failure Protection,Settings should be done by a readable HMI. Short Circuit Detection state-On/Run, Phasereverse detection state-on/start/run, EF detection delay time, Auto scroll/Manual Scroll, Fail Safe Features-on/off, Bar graph for OL setting, 3 nos. LED indications, Digital output- 1CO contactwith 5A rating for tripping and 2 nos. programmable for alarm, One no. fault record, Suitable for1A/5A CT secondary and supports CT ratio up-to 999 with external CT. Design Standards: IEC60947)/ IEC 60947-4-1/ IEC 61000-3-2/ IEC 61000-3-3/ IEC 60947-4-1. Operating temperaturerange: 0 ºC to 70ºC, Storage: : -10 ºC to 85ºC. Relative humidity: < 93%, non-condensing,Pollution Degree: 2, IP-54 Front Plate, Wiring: tunnel type. Aux Supply: 110/220VAC. Burden: 6
watt | 28 | No | 24,462 ₹6,84,936 |
| 1.02 | CURRENT TRANSFORMER | 84 | No | 2,090 ₹1,75,560 |
| 1.03 | POTENTIOL TRANSFORMER | 28 | No | 2,375 ₹66,500 |
| 1.04 | AUXILIARY CONTACTOR | 28 | No | 1,311 ₹36,708 |
| 1.05 | Auxiliary wiring, wire connecting, Socket etc | 28 | No | 1,900 ₹53,200 |
| 1.06 | Labour Charge | 28 | Ls | 5,225 ₹1,46,300 |
| 1.07 | OH & Profit @ 10% | 1 | No | 1,16,322 ₹1,16,322 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - |
Tender Value
₹15.9 L
EMD Value
₹19,900
Closing Date
1 Dec 2025, 6:00 pmClosed
Area Engineer(E and M)
Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Paschim Bardhaman, West Bengal-713346
Supply and installation of motor protection relay in different places under Pandaveswar Area
2025_ECL_347779_1
GM-PND/EandM/25-26/177/961 dated 15/11/2025
Open Tender
Electrical and Maintenance Works
60 days
Pandaveswar Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,900
2 Feb 2026
20 Nov 2025
2 Dec 2025
20 Nov 2025
1 Dec 2025
20 Nov 2025
20 Nov 2025 - 24 Nov 2025
Amount
Supply and installation of motor protection relay in different places under Pandaveswar Area . (Inclusive of EPF/CMPF)
SUPPLY AND FITTING OF(LT) MOTAR PROTECTION RELAY(Advance current based motor protection relay with multi protection and monitoring in compact, modular and smart 35mm din-rail enclosure. It should be a fully digital with seven segment display based on microprocessor technology with analogue to digital conversion of the measured values. The relay must have feature Over Load (50-150%) with Definite curve (0.01-60sec)/Inverse Curve Tripping Class (5-60), Short Circuit (200-800%), Under Current (20-90%),Unbalance(5-50%), Phase Loss, Phase Reversal, Stall(150-600%), Locked Rotor (200-1000%),Earth Fault[Residual(10-50%)/CBCT(30mA-3000mA)], Circuit Breaker Failure Protection,Settings should be done by a readable HMI. Short Circuit Detection state-On/Run, Phasereverse detection state-on/start/run, EF detection delay time, Auto scroll/Manual Scroll, Fail Safe Features-on/off, Bar graph for OL setting, 3 nos. LED indications, Digital output- 1CO contactwith 5A rating for tripping and 2 nos. programmable for alarm, One no. fault record, Suitable for1A/5A CT secondary and supports CT ratio up-to 999 with external CT. Design Standards: IEC60947)/ IEC 60947-4-1/ IEC 61000-3-2/ IEC 61000-3-3/ IEC 60947-4-1. Operating temperaturerange: 0 ºC to 70ºC, Storage: : -10 ºC to 85ºC. Relative humidity: < 93%, non-condensing,Pollution Degree: 2, IP-54 Front Plate, Wiring: tunnel type. Aux Supply: 110/220VAC. Burden: 6 watt
CURRENT TRANSFORMER
POTENTIOL TRANSFORMER
AUXILIARY CONTACTOR
Auxiliary wiring, wire connecting, Socket etc
Labour Charge
OH & Profit @ 10%
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.45 MB
BOQ_360489.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid