Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC AOC PLACED ON L1 BIDDER WITH CONTRACT AGREEMENT NO GE/SHL/48 OF 2023-2024 | |
| 2 | L2₹36.0 L+₹4.5 L (14.3%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER | |
| 3 | Rejected-Technical 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | - | Rejected-Technical Enlisted contractor is eligible class but not enlisted in eligible category. Hence, not recommended for opening of financial bid |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Aug 2023, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
REPAIR / MAINT OF DG SETS AND ALLIED WORK SERVICES AT CANTT AREA AND REPAIR/ MAINT OF AIR CONDITIONER REFRIGERATION AND HEATING PLANTS UNDER GE SHILLONG
2023_MES_606429_2
GE/SHL/TOKEN-30 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹60,000
Yes
31 Oct 2023
27 Jul 2023
23 Aug 2023
27 Jul 2023
22 Aug 2023
3 Aug 2023
Amount
AGE E/M SCHEDULE : DG SET M/L for Maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, check coolant level & make up the same ,drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, including M & L for V Belts, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load and record shall be made in respect of RPM , oil pressure , oil temperature , coolant temperature, voltage , frequency , load current , battery charging , fuel consumption etc complete all as specified and directed by Engineer in Charge. (a). Engine oil for refilling will be measured & paid separately. (b). Coolant for make up will be measured & paid separately (c). The Make of Fuel filter , Oil Filter , V belt & component will be as per manufactures recommendations and rate of fuel filter, oil filter, air filter and V belt Not inclusive in quoted rate.Capacity of DG 15 to 50 KVA and Make of DG Set Kirlosker/Cummins/Ashok Layland /CG/Sudhir
All as per Srl Item No.1 above but capacity of DG set 62.5/63 KVA and Make of DG Set Kirlosker/Cummins/Ashok Layland/CG/Sudhir
All as per Srl Item No.1 above but capacity of DG set 82.5 KVA and Make of DG Set Kirlosker/Cummins/ Ashok Layland/CG/Sudhir
All as per Srl Item No.1 above but capacity of DG set 125 KVA and Make of DG Set Kirlosker/Cummins/Ashok Layland/CG/Sudhir
All as per Srl Item No.1 above but capacity of DG set of 180/200 KVA Make of DG Set Kirlosker/Cummins/Ashok Layland/CG/Sudhir
Repair/maintenance of existing control panel of DG set by replacing the connected items such as leads, copper wire, thimble , Analogue Ammeter, Analogue voltmeter,frequancy meter etc along with other minor parts required for carrying out maintenance complete all as directed by Engineer in Charge. Note- Ammeter, Voltmeter and frequancy meter shall be measured and paid separately as supply only items below and labour element involve for replacing the same shall deemed to be included in the rate quoted against these item.
Supply only Analogue Ammeter Class 1, 5 A, 3 phase complete all as specified and directed
Supply only Analogue Voltmeter Class 1, 3 Ph complete all as specified and directed
Supply only Frequancy meter single phase, Class 0.20 complete all as specified and directed
Repair/ over hauling of self starter assembly of any type/make/ model including replacement of bearing bushing, washer, bendix pinion, carbon bush etc complete as required for proper functioning for the following capacities of DG sets complete all as directed by Engr-in-Charge:- Note: (i) Make of DG Sets shall be as specified against item No. (ii) Repair works shall be carried out by authorised agent / dealer of DG Sets.
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
Disconnecting the Exhaust Pipe Line with mufler of DG set from Exhaust Manifold of the Engine and removing the Unserviceable Asbestos Rope from the Exhaust Pipe, Cleaning the Exhaust Pipe and cutting the mufler removing all Carbon Particles Inside including wrapping of existing asbestos rope complete all as directed by Engr-in-charge for the following capacities of DG Sets:
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
Dismantaling Radiator assembly from DG set Engine from inside and out side , Cleaning and Washing the Radiators & fins by Compressed Air with Chemical Water, removing all dust, etc. from the Radiator and Filling Coolant, re-assemble the same in Original Position with new gaskets, radiator connecting hoses and clamps complete all as directed by Engr-in-charge, for the following capacities DG Sets:- Note:- (i) Coolant shall be measured and paid seperatly under relevnt items of these schudule. (ii) Asbestos rope shall be measured and paid separately under relevant items of these schedule. (iii) Repair works shall be carried out by authorised agent / dealer of DG Sets. (iv) Make of DG Sets shall be as spesified against item No 1 here-in-before.
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
Disconnecting the fuel tank including Inlet/Outlet Connections of the following capacities of DG sets and cleaning the Tank properly and removing all dusts, mud, etc. and refixing the fuel tank and Inlet/Outlet Pipe connections in orginal position complete all as directed by Engr-in-charge. Note :- (i) Repair/ maintenance & servicing shall be carried out through authorized representative of manufacturer's of DG Sets.
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
Material and labour for Rewinding of starter armature complete for the following capacities of DG sets With super enamelled copper winding wire including taking out old unserviceable winding complete all as specifed and as directed :- Note: (i) Make of DG Set shall be as specified against item No. (ii) Repair/ maintenance & servicing shall be carried out through authorized representative of manufacturer's of DG Sets.
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
Repair / over hauling of automatic/manual, Governor assembly of any make/type/model complete including calibration and replacement of spare parts as required to make the governor 100 % trouble free complete all as directed by Engr-in-Charge:- Note: (i) Make of DG Set shall be as specified against item No . (ii) Cost of spare parts shall deemed to be included in the rate quoted .
DG set 180 to 200 KVA
DG set 125 to 160 KVA
DG set 63 to 82.50 KVA
DG set 10 to 40 KVA
M & L in repair to taking down demage/unserviceble Battery of 12 Volts 180 AH by replace new battery of same capcity complete all as required including charging etc for proper functioning complete all as specified and directed by Engr-in-Charge. Make- Exide/Luminous/Amron OR equivalent make
All as per item No. 13 above but for 80 to 120 AH Battery as per requirement Make- Exide/Luminous/Amron OR equivalent make
Repair/ over hauling, servicing of alternator for battery charger of 12 Volt Battery of any make / type / rewinding of armature and field coil including replacement of bearing / bushing etc and make the alternator 100% serviceable complete all as directed by Engineer-in-Charge.
S&F MCCB 4 pole 400 Amps, 36 KA,415 Volts, with thermal magenetic release, etc complete including taking down old unserviceable MCCB. Make- L&T Cat No CM98403OOROOG or equivalent model from make legrand/Siemens
S&F MCCB 250 Amps Four pole 25 KA 415 Volts ,adjustable thermal & fixed Magnetic setting Make including taking down old unserviceable MCCB : Havells Cat No IHLANF0250 or L&T cat NO-CM90642OOPO equvalent model from Legrand/Siemens
Repair/ servicing of alternator of any make/type/model including grinding/polishing of slip rings assembly cleaning and re-tensioning of carbon bush holder including replacement of carbon bush for the alternators of following DG Sets : Note: (i) Make of DG Set shall be as specified against item No . (ii) Cost of spare shall demand to be included in the rate quoted by the tender
DG set 125 to 200 KVA
DG set 40 to 82.5 KVA
DG set 10 to 30 KVA
Taking out of defective automatic voltage regulator (AVR) of DG set (alternator side) and supply and fix New automatic voltage regulator (AVR) including necessary connection, testing and cable work etc complete all as directed by Engr-in-charge for the following capacities of DG Sets :-
(a) DG set 160 to 200 KVA
(b) DG set 30 to 140 KVA
Supply only the following spare parts (if required) for DG set 180/200 KVA as specified against item No 1 here-in-before.
Gasket set.
Head gasket
Valve steam seal
Rear oil seal
Front oil seal
Hose pipe set
Hose clamp set
Flexible pipe set
Copper washer set.
Air filter set.
Diesel filter set.
Oil filter set.
Fan belt.
Solonied switch.
Oil temperature gauge
Oil pressure gauge
Lube oil pump
Stop Solonied assy
High Pressure pipe
Door Lock
Supply only the following spare parts for DG set 63 to 160 KVA as specified against item No 1 here-in-before.
Gasket set.
Head gasket
Valve steam seal
Rear oil seal
Front oil seal
Hose pipe set
Hose clamp set
Flexible pipe set
Copper washer set.
Air filter set.
Diesel filter set.
Oil filter set.
Fan belt.
Solonied switch.
Oil temperature gauge
Oil pressure gauge
Lube oil pump
Stop Solonied assy
High Pressure pipe
Door Lock
Supply only the following spare parts for DG set 10 to 40 KVA as specified against item No 1 here-in-before.
Gasket set.
Head gasket
Valve steam seal
Rear oil seal
Front oil seal
Hose pipe set
Hose clamp set
Flexible pipe set
Copper washer set.
Air filter set.
Diesel filter set.
Oil filter set.
Fan belt.
Solonied switch.
Oil temperature gauge
Oil pressure gauge
Lube oil pump
Stop Solonied assy
High Pressure pipe
Door Lock
Supply only Engine Oil (20 W 40) Make- Servo/Castrol /BPCL.
Supply only Coolent Make- Fleet Guard or equivalent Make as approved by GE.
Supply only Distilled water for Battery as per sample
Supply and Fix Asbestos rope of required size.
S&F in repairs Battery connection cable of length 1.2 Mtr with solid brass clamp lugs for "+" terminals at one side and copper lug on other side.
S&F in repairs Battery connection cable of length 1.2 Mtr with solid brass clamp lugs for "-" terminals at one side and copper lug on other side.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.00 mm buried directly in ground connected to galvanized earth lead strip of size 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC type C1 (1:3:6, using 20mm graded crushed stone aggregates) 50mm thick precast RCC type B1, (1:2:4, using 20mm graded crushed stone aggregates) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 32mm x 6mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance n.exc 50m and necessary connection and testing complete all as shown in electrical plate No 3 of SSR Part-I, 2009 and all as specified and directed including taking down old unserviceable earth pit and accessories. Note : GI Strip upto 7.5m length shall be deemed to include in the cost of above item. This quantity required over and above shall be measured under relevant items of these schedule.
S&F, GI strip 32 x 6 mm as eath continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc including dismantling old unserviceable strip complete all as specified and directed by Engr-in-Charge.
Excavation In trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in soft/soil for laying/removing of XLPE cables
Returning, filling in, including, spreading, levelling, watering and wall ramming, in layers not exceeding 25Cm in soil obtained from excavation complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point
M & L for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed.
M & L Sub class'B' old size well burnt brick laid flat in trenches as protection to LT cable complete all as specified and as directed.
S&F XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cables (heavy duty) 1100 Volts grade, with stranded aluminium conductor of size 150 Sqmm 3.5 core, including taking out old unserviceable cable including PVC flexible pipe for cable protection complete all as specified and as directed.
All as per item No. 36 above but size of XLPE cables 120 Sqmm 3.5 core.
All as per item No. 36 above but size of XLPE cables 95 Sqmm 3.5 core.
All as per item No. 36 above but size of XLPE cables 70 Sqmm 3.5 core.
All as per item No. 36 above but size of XLPE cables 50 Sqmm 3.5 core.
S&F Changeover switch 400 Amps, in sheet steel enclosure, 4 Pole, side handle operated complete including taking down old unserviceable one. Make:- L&T Cat Part No. CO44000OSOO or equivalent model from Make:- Schneider / Siemens.
S&F Changeover switch 250 Amps, in sheet steel enclosure, 4 Pole, side handle operated complete all as specified and as directed taking down old unserviceable one. Make:- L&T Cat Part No. CO32500OSOO or equivalent model from Make:- Schneider / Siemens.
S&F Changeover switch 160 Amps, in sheet steel enclosure, 4 Pole, side handle operated complete including taking down old unserviceable one complete all as specified and as directed. Make:- L&T Cat Part No. CO21600OSOO or equivalent model from Make:- Schneider / Siemens.
S&F Changeover switch 63 Amps, in sheet steel enclosure, 4 Pole, side handle operated complete including taking down old unserviceable one. complete all as specified and as directed. Make:- L&T Cat Part No. CO10630OSOO or equivalent model from Make:- Schneider / Siemens.
S&F MCCB, 3 pole, 415 Volts,160 Amps, 36 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one complete all as specified and as directed. Make :- 'L&T' Cat part No. CM92008OOM1OG or equivalent model from make:- Legrand / Schneider
S&F MCCB, 3 pole, 415 Volts,125 Amps, 16 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one. Make :- 'L&T' Cat part No. CM90676OOLO or equivalent model from make:- Legrand / Schneider
S&F MCCB, 3 pole, 415 Volts,100 Amps, 16 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one complete all as specified and as directed. Make :- 'L&T' Cat part No.CM90517OOKO or equivalent model from make:- Legrand / Schneider
Supply only MCCB, 3 pole, 415 Volts, 63 Amps, 16 kA breaking capacity with thermal and magnetic release including taking down old unserviceable one complete all as specified and as directed. Make :- 'L&T' Cat part No.CM90517OOHO or equivalent model from make:- Legrand / Schneider Note:- Materials shall be fixed to panel board as mentioned here in after.
M&L 25mm thick PCC type B2 ( 1:2:4, using 40 mm graded aggregates) as in floor, finished even and smooth without using extra cement including demolition of old unserviceable concrete complete all as specified and as directed.
Supply only First aid Kit with all accessories including necessary medicines complete all as directed.
Supplying and laying insulated Electrical matting class 1, proof voltage tested upto 10 KV, 2mm thick ness of size 1.00 mtr (wide) with one side fabric and other side plain finish as per IEC 61111 including taking out old unserviceable rubber matting. Make:- Raychem or equivalent as approved by Accepting officer.
AGE E/M SCHEDULE AC, REFRIGERATORS AND HEATING PLANT The Quoted rates shall to be included for the following :- (a) As the above work is required to be carried out for repair/maint of cooling appliances entire Mil Stn Shillong (Including HV, SE Falls and Cantt Area) , hence complaints of the US equipment’s (Refrigerators/DF/ACs/voltage stabilizers) to be handed over daily basis (if received) for different units locations and repairs to be carried out on the same day or next day or as directed by Engr-in-Charge. (b) The contractor shall depute adequate AC mechanic and helper (As per the complaint) with all connected tools on daily basis (if required) with suitable vehicle & T&P arrangement to repairs and attend the complaints in various units under AOR of GE Shillong and manage all spares included in this CA in advance or as directed by Engr-in-Charge. (c) Non attending the complaints with in 48 hrs Rs 500/- per day per complaints shall be recovered.
S&F in repair of sealed compressor rotary type of capacity 1.5TR suitable for window/split type air conditioner complete all as directed by Engineer-in-Charge.Make:- Carrier / Voltas/ LG/ Bluestar/ Hitachi
S&F in repair of sealed compressor scroll type of capacity 2/1.5TR suitable for inverter type split type air conditioner complete all as directed by Engineer-in-Charge.Make:- Carrier / Voltas/ LG/ Bluestar/ Hitachi
S&F Relay, box type for 1.5/2.0 Ton capacity Split/Window type Ac as in repairs complete all as directed by Engr-in-Charge. Make: DANFOSS/RANUTAL/ORSIO/INDFOSS.
S&F Capacitor Running type, 45/55 mfd for window /Split type Ac 1.5/2.0 ton capacity as in repairs complete all as directed by Engr-in-Charge. Make: CIVCON/SARDA/UNIVERSAL/HAVELLS
S&F Starting capacitor, 80-120 mfd for window/Split type air conditioner 1.5/2.0 ton capacity as in repairs complete all as directed by Engr-in-Charge. Make: CIVCON/ SARDA/ UNIVERSAL/ HAVELLS.
S&F Fan blade with blower motor for window/split type AC 1.5/2.0 ton capacity as in repairs complete all as directed by Engr-in-Charge. Make:LG/Voltas
S&F Blower motor of suitable for 1.5/2.0 TR capacity Window/Split Type AC all as directed by Engr-in-Charge as in repairs. Make: NGEF/Kivon / Crompton Greaves / LG/Voltas/Carrier.
S&F Rotary type knob for Window type AC as in repairs complete all as directed by Engr-in-Charge. Make:LG/Voltas/Carrier/Carrier
S&F Roller assembly for Split type AC as in repairs complete all as directed by Engr-in-Charge.
S&F Toggle switch for window/split type AC as in repairs complete all as directed by Engr-in-Charge. Make: KAYCEE/L&T/Havells
S&F Flaring nut for Split Type AC of size 1/2"/1/4"/5/8" as in repairs complete all as directed by Engr-in-Charge.
S&F Air filter suitable for 1.5/2.0 TR capacity Window/Split Type AC as in repairs complete all as directed by Engr-in-Charge.Make: LG/Voltas/Carrier
S&F Over load protector suitable for 1.5/2.0 TR Window/Split Type AC as in repairs complete all as directed by Engr-in-Charge. Make: Siemns/ Crompton Greaves/Legrand/L&T.
Dismantling the outdoor and indoor unit of Split type air conditioner, 1.5 ton capacity after removing refrigerant pipe connection, electric wire connection including refixing in the same position after following repairs and complete servicing of machine complete all as directed by Engr-in-Charge :- (a) Repairs of the suction and discharge tube and cooling coil and replacement of heat resistive thermocol, tube for gas & liquid line. (b) De-scaling the complete refrigeration system with carbon tetra chloride solution, replacement of defective capillary tube, strainer and dryer unit of required size assembling the system, leakage test of the system by applying approximate head and vacuum up to (-) 75 Cm column of mercury. (c) Recharging of gas with suitable refrigerant as required and testing the cooling effect satisfactorily on full load after re-installation of air condition complete all as directed. Note : Refrigerant Gas shall be measured and paid separately as 'Supply only' items.
Supply only refrigerant gas suitable for refrigerator, deep freezer,Window ,Split type Acs etc. complete including testing the cooling effect satisfactorily on full load all as directed by Engineer-in-Charge. Make Moto : R22(Ac),134 A(Deep freezer) R12 (Refrigerator), R-410 A (AC), R-32
S&F Panel Circuit Board (PCB) for 1.5 /2.0 TR Window/Split type AC as in repairs complete all as directed by Engr-in-Charge Make: LG/Samsung/Voltas
S&F Remote circuit complete with remote device for 1.5/2.0 TR Window/Split type AC as in repairs complete all as directed by Engr-in-Charge.Make: LG/Samsung/Voltas
S&F PVC insulated & sheathed copper conductor 1100 volts grade 3 core, 4 Sqmm ISI marked for ACs & Refrigerators including taking down old unserviceable copper conductor.
M&L Servicing of 1.5TR split/window type AC of make:- LG/ Voltas/ Carrier/ Amtrex after removing electric wire connection & cleaning of Cooling coil, condenrer coil, Filter, replacement of any unserviceable minor parts such as relay, capacitor , kobs etc. complete all as specified and directed by Engineer-in- Charge. Note : Cost of minor spare parts shall deemed to be included in the rate qoted by the tenderer.
S&F Sheet metal enclosures with socket plug top & MCB single pole & neutral enclosure with a two pin & earth plug and socket complete with one single pole and neutral MCB -240 Volt- 20 Amps, 'C' series including taking down old unserviceable plug and socket. Make: Havells Cat No: DHDPUSN020 or equivalent of L&T/ Legrand/Schneider.
M & L Sub main wiring with two runs of 6 Sqmm FR grade, (ISI mark) PVC insulated, multi stranded, unsheathed, copper conductor and one run of, PVC insulated multistranded FR, grade (ISI mark) unsheathed copper conductor of size 6.0 Sqmm as earth lead including PVC casing capping of suitable size, complete all as specified and directed, including taking down old unservicable submain wiring. Note: Two runs of 6 Sqmm, one run of earth wire of size 6.0 Sqmm and one run of PVC casing capping shall be measured as one unit.
S&F Condenser unit complete for 1.5/2.0 TR Window/Split type AC as in repairs complete all as directed by Engr-in-Charge. Make: LG/Voltas/Carrier
S&F Evaporator unit complete for 1.5/2.0 TR Window/Split type AC as in repairs complete all as directed by Engr-in-Charge. Make: LG/Voltas/Carrier
S&F Capillary tube and strainner with filter complete for 1.5/2.0 TR window/split type AC as in repairs.
M&L Cooling coil complete with aluminium deep freezer chamber for refrigerator of any capacity as in repairs. Make: Voltas/Blue Star
Dismantling of sealed compressor unit after removing all electrical connection and cutting of refrigerant pipe from refrigerators of 300/310/315/410 Ltrs capacity including de-scaling the refrigeration system with carbon tetra chloride solution, replacement of defective capillary tube, strainer and dryer filter of required size, re-assembling the system including recharging of suitable refrigerant as required, including testing of the complete system complete all as directed by Engr-in-Charge. Note for item Nos 26 to 28:- refrigerent gas shall be measured and paid separately under relevant items of these schedule.
All as per item No 78 above but for refrigerator 165/180 ltrs capacity.
All as per item No 78 above but for deep freezer of capacity 320/220 ltrs.
S&F Relay for refrigerator/deep freezer of various capacities as in repairs complete all as directed by Engr-in-Charge. Make : Siemens/LG /Carrier/Bhestar.
S&F Sealed compressor for refrigerator of capacity 180 ltrs, including sealing of the compressor with welding as in repairs complete all as directed by Engr-in-Charge. Make: LG/ Voltas/ CARRIER
S&F Sealed compressor for refrigerator / deep freezers of capacity 286/300/315/345 ltrs, including sealing of the compressor with welding as in repairs complete all as directed by Engr-in-Charge. Make: SRIRAM/ KIRLOSKAR/ CARRIER.
M&L Thermostat switch suitable for refrigerator/deep freezer of any capacity as in repairs complete all directed. Make: Blue Star/Voltas/Carrier
M&L Cabinet lamp including lamp holder and push switch including connection with electric wires as in repairs complete all as directed.
M&L Door rubber gasket complete for refrigerator up to 320 Ltrs capacity as in repairs complete all as specified & as directed
M&L Defrost timer for refrigerator/deep freezer any capacity as in repairs complete all as directed. Make: Blue Star/Voltas/Godrej/Samsung
M&L Bi-metal for refrigerator/deep freezer any capacity as in repairs all as specified and directed.
S&F Cooling coil with aluminium chamber for Freezer as in repairs complete of Refrigerator upto 320 Ltrs complete all as specified & as directed
S&F Defrost heater suitable for Refrigerator of any capacity as in reparis complete all as specified & as directed.
S&F Copper suction and discharge pipe icluding insulation suitable for AC 1.5/2.0 Ton of any dia as in repairs complete all as directed by Engr-in-charge.
S&F in repair of heating element of capacity 1.5/2 KW for heating system complete all as specified and directed.
S&F in repair of thermostat for heating system complete all as specified and directed.
S&F in repair of temperature gauge for heating system complete all as specifeid and directed.
S&F in repair of pre air filter of size 600x600mm for heating system complete all as specified and directed.
S & F in repair of fine filter of size 600x600mm for heating system complete all as specified and as directed.
S&F in repair of pre air filter of size 300x600mm for heating system complete all as specified and directed.
S & F in repair of fine filter of size 300x600mm for heating system complete all as specified and as directed.
S&F in repair of power contactor 3 pole 440 volts 32 Amps complete all as specified and directed. Make :- L&T / Siemens / Legrand
M&L Strip heater of capacity 3 KW for heating plant as in repairs complete all as directed.
S&F Pan type heating element of 3 KW capacity for heating plant as in repairs complete all as directed
M&L PVC drain pipe 25mm bore, fixed on wall/roof/floor with necessary clamp/hook complete all as specified & as directed as in repair.
S&F in repair taking down transformer of voltage stabilizer 4/5 KVA and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with 'E' class varnish, including and reassembling and fixing in position complete all as specified & directed by the Engineer-in-charge.
S&F in repair, capacitor 10 MFD for fan motor of water coolers/refrigerator complete all as specified & directed by Engineer-in-charge. Make-Epcos/Bajaj/ Havells/CG
S&F in repair, capacitor 15 MFD for fan motor of water coolers/refrigerator complete all as specified & directed by Engineer-in-charge. Make-Epcos/Bajaj/ Havells/CG
S&F in repairs running capacitor(oil type)36 mfd suitable for water cooler of any capacity complete all as specified & directed by Engineer-in-charge. Make-Epcos/Bajaj/ Havells/CG
S&F in repair blower fan motor of capacity 1/30 or 1/20 HP copper wound suitable for split type AC1.5 TR, AC/DC complete including testing commissioning complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, condensor fan motor for deep freezer of any make and capacity complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, capillary tube suitable for any make & capacity deep freezer/refrigerator complete all as specified & directed by Engineer-in-charge. Make- As per existing make and model
S&F in repair, plug top 3 pin 5 amps, 230 volts (ISI marked) complete all as specified & directed by Engineer-in-charge. Make C&S/ Anchore/Legrand or equivalent
M/s RS Enterprises & Supplier
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .