Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3,539.45Accepted-Finance 37 541 NEW MOTI NAGAR NEW MOTI NAGAR WEST DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | L1 | Accepted-Finance As per BOQ Chart | |
| 2 | Not L1₹5,239.14Accepted-Finance | Not L1 | Accepted-Finance As per BOQ Chart | |
| 3 | Not Admitted-Fee/PreQual/Technical 279 1 KOT KISHAN CHAND JALANDHAR JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical 1518 8 BHAGIRATH PALACE DELHI DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹46,898
Closing Date
11 Feb 2021, 9:30 amClosed
Presiding Officer Procurement Committee
Presiding Officer Procurement Committee MH JRC
Buy of various items of medicines to MH Jalandhar
2021_ARMY_419084_1
MS/711/DGLP/RE NO 106 /CAT I /2020-21
Open Tender
Drugs and Pharmaceutical Products
Buy
28 days
MH JALANDHAR CANTT
Open Tender Enquiry as per RFP
2 documents required · 2 mandatory
₹0
₹46,898
Yes
13 Feb 2021
4 Feb 2021
11 Feb 2021
4 Feb 2021
11 Feb 2021
4 Feb 2021
4 Feb 2021 - 10 Feb 2021
Medicines :
Vented IV infusion Set made up of DEHP Free specialized material, with Anti Run Dry, Auto Prime, Needle Free access Valve, pinch and roller clamp along with and flow controller.
All in one Closed IV catheter system with pre-attached high pressure extension set (up to 300PSI); with two split septum, closed system needle-less connectors; catheter made up of specialized material with indwelling time of up to 144 hrs.; needle tip encapsulated in plastic cap for NSI prevention; ‘insta- flash’ technology for instant flash back. 18G
All in one Closed IV catheter system with pre-attached high pressure extension set (up to 300PSI); with two split septum, closed system needle-less connectors; catheter made up of specialized material with indwelling time of up to 144 hrs.; needle tip encapsulated in plastic cap for NSI prevention; ‘insta- flash’ technology for instant flash back.20G
Prefilled Terminally Sterile single use device for flushing of catheter with Heparinized saline, minimizing break-loose contamination, Pre-labelled and color-coded, avoiding medication error, 10ml diameter barrel size, in compliance to INS standard, reducing increased flush pressure, Luer cap design, facilitating easy remove and preventing leakage, Heparin is high molecular weight heparin, unfractionated, compliance to USP standard. 3ml 10 IU
Prefilled Terminally Sterile single use device for flushing of catheter with Heparinized saline, minimizing break-loose contamination, Pre-labelled and color-coded, avoiding medication error, 10ml diameter barrel size, in compliance to INS standard, reducing increased flush pressure, Luer cap design, facilitating easy remove and preventing leakage, Heparin is high molecular weight heparin, unfractionated, compliance to USP standard.3ml 100 IU
Prefilled Terminally Sterile single use device for flushing of catheter with Heparinized saline, minimizing break-loose contamination, Pre-labelled and color-coded, avoiding medication error, 10ml diameter barrel size, in compliance to INS standard, reducing increased flush pressure, Luer cap design, facilitating easy remove and preventing leakage, Heparin is high molecular weight heparin, unfractionated, compliance to USP standard.5ml 10 IU
Prefilled Terminally Sterile single use device for flushing of catheter with Heparinized saline, minimizing break-loose contamination, Pre-labelled and color-coded, avoiding medication error, 10ml diameter barrel size, in compliance to INS standard, reducing increased flush pressure, Luer cap design, facilitating easy remove and preventing leakage, Heparin is high molecular weight heparin, unfractionated, compliance to USP standard. 5ml 100 IU
Prefilled Terminally Sterile single use device for flushing of catheter with 0.9% salinesolution having standard 10ml syringe diameter with design to minimize syringe induced reflux. Should be latex & PVC free. Thesaline should be preservative free.3ml
Prefilled Terminally Sterile single use device for flushing of catheter with 0.9% salinesolution having standard 10ml syringe diameter with design to minimize syringe induced reflux. Should be latex & PVC free. The saline should be preservativefree.5ml
Prefilled Terminally Sterile single use device for flushing of catheter with 0.9% salinesolution having standard 10ml syringe diameter with design to minimize syringe induced reflux. Should be latex & PVC free. Thesaline should be preservative free.10ml
Vented IV infusion Set made up of DEHP Free specialized material, with Anti Run Dry, Auto Prime, with dual port NeedleFree access Valve, pinch androller clamp
IV cannula made up of polytetrafluoroethylene With Insta flash needle technology for faster visualization or flashback by notch, it is an over the needle peripheral intravenous catheter intended for infusion/injections. Cannula contains a Luer-Lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula 18G.
IV cannula made up of polytetrafluoroethylene With Insta flash needle technology for faster visualization or flashback by notch, it is an over the needle peripheral intravenous catheter intended for infusion/ injections. Cannula contains a Luer-Lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula 20G.
Bi Ext Needless IV system with closed luer access having self sealing silicone split septum (not reverse septum) and transparent housing.
50ml syringes without needle,Syringe made of Polypropylene plastic (PVC free plastic),Syringe nozzle design should be Luerlok Packing should be Blister with medical grade paper Sterilized with ETO, Polyisoprene used as stopper (Latex free syringe) Silicone oilused as lubricant
20 ml syringes without needle,Syringe made of Polypropylene plastic (PVC free plastic),Syringe nozzle design should be Luerlok Packing should be Blister with medical grade paper Sterilized with ETO, Polyisoprene used as stopper (Latex free syringe) Silicone oil used as lubricant
5ml RUP syringe with needle Actively disabling Reuse prevention feature, permanently disabled by user after completion of intended use even after multiple plunger movements to prevent subsequent reuse of the syringe, equivalent to ISO 7864, Type2-B
10ml RUP syringe with needle Actively disabling Reuse prevention feature, permanently disabled by user after completion of intended use even after multiple plunger movements to prevent subsequent reuse of the syringe, equivalent to ISO 7864, Type2-B
18 G Non ported IV catheter made up Vialone biomaterial material that gives up to 98%kink recovery, softens up to 70% in vein and provides in-dwelling time up to 96hrs.Should have wings and come along with the cap to guard the cannula tip
Leak and puncture resistant 5.4 ltrsharp collector with blue brackets facilitating one handed disposable, satisfying NIOSG guideline on sharps disposable container, made of non-toxic colorants and compliance with CONEG heavy metal limits. Should be made up of virgin plastic & chlorinated free.
Leak and puncture resistant 1.5 ltr sharp collector with red brackets facilitating onehanded disposable, satisfying NIOSG guideline on sharps disposable container, made of non-toxic colorants and compliance with CONEG heavy metallimits. Should be made up of virgin plastic & chlorinatedfree.
20 G Non ported IV catheter made up Vialone biomaterial material that gives up to 98%kink recovery, softens up to 70% in vein and provides in-dwelling time up to 96hrs.Should have wings and come along withthe cap to guard the cannula tip.
AllinoneClosedIVcatheter system with pre-attached highpressureextensionset (up to 300PSI); with two splitseptum,closedsystem needle-less connectors; catheter made up of specialized material with indwellingtimeofupto144 hrs.;needletipencapsulated in plastic cap for NSI prevention; ‘insta-flash’ technologyforinstantflashback.22G
Non ported IV catheter with Insta-flashtechnologyforinstant flashback,madeupspecialized Vialone biomaterial materialthat gives up to 98% kink recovery, softens up to 70% in vein and providesin-dwellingtimeupto 96hrs.Catheter material consistingofRadioopaquestripforbettervisualizationduringCT Scan.24G
Non ported IV catheter with Insta-flash technology for instantflashback,madeupspecialized Vialone biomaterial materialthat gives up to 98% kink recovery, softens up to 70% in vein and providesin-dwellingtimeupto 96hrs.Catheter material consistingofRadioopaquestrip forbettervisualizationduringCTScan.26G
Arterial catheter Designed for peripheral arterial cannulationwith an on/off device thatpreventsbackflowofblood (20G).
IV cannula made up of polytetrafluoroethylene WithInstaflashneedletechnologyfor fastervisualizationorflashback bynotch,itisanovertheneedle peripheraltravenouscatheter intended for infusion/injections. Cannula contains a Luer-Lock plugattachedtotheflowcontrol plug,isadisposabledevice.Has an injection port and flexible wingstosupportthecannula.22G
PencilPointSpinalNeedlewith precision formed side hole having sculpturedandtranslucent hub.25G
PencilPointSpinalNeedlewith precisionformedsideholehaving sculptured and translucent hub.27G
5mlRUPsyringewithneedle Actively disablingReuse prevention feature,permanently disabled by user after completionofintendeduseeven after multiple plunger movements topreventsubsequentreuseofthesyringe, equivalenttoISO7864,Type2-B
22 G Non ported IV catheter made up Vialone biomaterial material that gives up to 98% kinkrecovery,softensupto70% inveinandprovidesin-dwelling timeupto96hrs.Shouldhavewingsandcomealongwiththe captoguardthecannulatip.
Durga Medicare
Anaesthesia 2
Anaesthesia 3
Anaesthesia 4
Anaesthesia 5
Anaesthesia 6
Anaesthesia 7
Anaesthesia 8
Anaesthesia 9
Anaesthesia 10
Anaesthesia 11
Anaesthesia 12
Anaesthesia 13
Anaesthesia 14
Anaesthesia 15
Anaesthesia 16
Anaesthesia 17
Anaesthesia 18
Anaesthesia 19
Anaesthesia 20
Anaesthesia 21
Anaesthesia 22
Anaesthesia 23
Anaesthesia 24
Anaesthesia 25
Anaesthesia 26
Anaesthesia 27
Anaesthesia 28
Anaesthesia 29
Anaesthesia 30
Anaesthesia 31
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .