| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAdmitted-Finance 0 SHANKERPURI COLONY SAHARANPUR BEHAT ROAD NEAR DEHAT KOTWALI SAHARANPUR UTTAR PRADESH 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Admitted-Finance | |
| 2 | Rejected-Technical 100 33 1 R G S ROAD USHAGRAM SALANPUR 713303 WEST BENGAL INDIA | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | 713303 | - | Rejected-Technical as per approved TCR | |
| 3 | Rejected-Technical | - | Rejected-Technical as per approved TCR |
| Sl No | Description | Qty | Unit | ELECTRO TRADING CO. L1 |
|---|---|---|---|---|
| 1.00Item description | ||||
| 1.01 | Cost of testing by Megger insulation tester of 01 no. of 500 kVA, 11 kV/550V transformer | 1 | No. | 2,000 ₹2,000 Lowest |
| 1.02 | Cost of testing by High Voltage Pressure test of 1 no of 500 kVA, 11 kV/550 V | 1 | No. | 6,500 ₹6,500 Lowest |
| 1.03 | Cost of testing of Transformer oil by dissolved gas analysis Test, Acididty Test, Di -electric test, Water content measurement test of 01 no. of 500 kVA, 11 kV/550 V transformer | 1 | No. | 19,000 ₹19,000 Lowest |
| 1.04 | Cost of testing by Megger Insulation testing of 02 nos of 3.3 kV VCB and 4 Nos of 11 kV VCB | 6 | Nos. | 2,000 ₹12,000 Lowest |
| 1.05 | Cost of testing by high Voltage Pressure test of 02 nos of 3.3 kV VCB and 4 Nos of 11 kV VCB | 6 | Nos. | 6,500 ₹39,000 Lowest |
| 1.06 | Supply and installation of Numerical IDMT relay consisting of 02 nos Overcurrent relay and 01 no Earth fault relay with instantaneous protection including 110 V auxiliary wiring | 1 | No. | 50,700 ₹50,700 Lowest |
| 1.07 | Supply and fitting of Numerical Earth Leakage relay current range 300 mA to 3000 mA with 100 mm dia fiber molded CBCT | 1 | No. | 25,200 ₹25,200 Lowest |
| 1.08 | Cost of repairing, testing & calibration of IDMT relay (02 nos. Over current and 01 no earth fault relay) by sceondary current injection test set including supply of necessary spares in place of damaged spares | 6 | Nos. | 7,500 ₹45,000 Lowest |
| 1.09 | Cost of repairing, testing and calibration of earth leakage relay by secondary current injection test set including supply of necessary spares in place of damaged spares | 6 | nos. | 7,500 ₹45,000 Lowest |
Tender Value
₹3.6 L
EMD Value
₹4,500
Closing Date
28 Feb 2026, 4:00 pmClosed
General Manager Satgram-Sripur Area
Office of the General Manager, Satgram-Sripur Area, PO-Devchandnagar, WestBengal-713332
Installation of Overcurrent, Earth Fault and Earth Leakage Relay with testing of transformers, switchgear installed at Bhanora West Block Colliery, ECL
2026_ECL_353529_1
ECL/SSA/GM/E M/E-NIT/2025-26/130 Dt 16.02.2026
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Bhanora WB Colliery, SSA
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,500
12 Mar 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
28 Feb 2026
19 Feb 2026
19 Feb 2026 - 23 Feb 2026
Item description
Cost of testing by Megger insulation tester of 01 no. of 500 kVA, 11 kV/550V transformer
Cost of testing by High Voltage Pressure test of 1 no of 500 kVA, 11 kV/550 V
Cost of testing of Transformer oil by dissolved gas analysis Test, Acididty Test, Di -electric test, Water content measurement test of 01 no. of 500 kVA, 11 kV/550 V transformer
Cost of testing by Megger Insulation testing of 02 nos of 3.3 kV VCB and 4 Nos of 11 kV VCB
Cost of testing by high Voltage Pressure test of 02 nos of 3.3 kV VCB and 4 Nos of 11 kV VCB
Supply and installation of Numerical IDMT relay consisting of 02 nos Overcurrent relay and 01 no Earth fault relay with instantaneous protection including 110 V auxiliary wiring
Supply and fitting of Numerical Earth Leakage relay current range 300 mA to 3000 mA with 100 mm dia fiber molded CBCT
Cost of repairing, testing & calibration of IDMT relay (02 nos. Over current and 01 no earth fault relay) by sceondary current injection test set including supply of necessary spares in place of damaged spares
Cost of repairing, testing and calibration of earth leakage relay by secondary current injection test set including supply of necessary spares in place of damaged spares
Cost of testing of current transformer by Primary Injection kit
Transportation charges
Contractor's profit
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.07 MB
Tendernotice_2.pdf
PDF • 0.79 MB
BOQ_366332.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .