for Creation of 63 KVA Sub stations alongwith erection of 11 KV Line on 9 mtr. ST poles, 30mm Sq ACSR conductor LT line on 8 mtr. ST Pole at Village Kakrai W.no 5 ST Basti Tehsil Majalta Distirct Udhampur on turnkey basis under UT Capex
2025_PDD_272934_1
ED/UDH/42 of 2024-25 dated 20-02-2025
Open Tender
Electrical Works
Turn-key
30 days
in Udhampur District
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer
₹22,000
11 Mar 2025
20 Feb 2025
1 Mar 2025
20 Feb 2025
27 Feb 2025
20 Feb 2025
20 Feb 2025 - 22 Feb 2025
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Weasel Conductor at village Kakrai Ward No. 05 ST Basti at Tehsil Majalta District Udhampur
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR Weasel Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Installation of 63 KVA transformer at village Kakrai Ward No. 05 ST Basti at Tehsil Majalta District Udhampur.
11/0.433kV, 3-phase Distribution Transformers 63 KVA with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
300 mm² (2ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
9 Mtr. Long Pole( ST-410 SP56)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger plates with clamps
GI Barbed wire for Anti Climbing
3 phase Trivector meter with CT/PT unit
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Painting of 9 mtr long ST poles with one coat of Red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT line with 30mm ACSR Weasel conductor on 8 mtr. Long ST poles for I at village Kakrai Ward No. 05 ST Basti at Tehsil Majalta District Udhampur.
8 mtr. Long ST Pole (ST-410 SP-15)
GI M Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insualtor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line with 30mm ACSR Weasel conductor on 8 mtr. Long ST poles for at village Kakrai Ward No. 05 ST Basti at Tehsil Majalta District Udhampur.
8 mtr. Long ST Pole (ST-410 SP-15)
GI M Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insualtor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
SWASTIK ELECTRICAL AND CONSTRUCTION WORKS (BID ID -2339682)
The Trikuta Engineer (BID ID -2339300)
ADITYA SHARMA (BID ID -2338430)
M/S RAINBOW TRADERS (BID ID -2339690)
VEENA CONSTRUCTION CO. (BID ID -2338970)
M R ENGINEERS & TRADERS (BID ID -2339997)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .