Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 CrAccepted-AOC NO 28 4TH A CROSS 1ST MAIN ROAD ATTUR LAYOUT YELAHANKA NEW TOWN BANGALORE 560064 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560064 | ₹2.8 Cr Quoted ₹2.9 Cr | 1 | Accepted-AOC being L1 |
| 2 | 2₹3.4 Cr+₹51.5 L (18.0%)Rejected-AOC | ₹3.4 Cr+₹51.5 L (18.0%) | 2 | Rejected-AOC being not L1 |
| 3 | 3₹3.3 Cr+₹45.1 L (15.8%)Rejected-AOC | ₹3.3 Cr+₹45.1 L (15.8%) | 3 | Rejected-AOC being not L1 |
| 4 | 4₹3.4 Cr+₹58.3 L (20.4%)Rejected-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹3.4 Cr+₹58.3 L (20.4%) | 4 | Rejected-AOC being not L1 |
Tender Value
₹3.3 Cr
EMD Value
₹4 L
Closing Date
18 Oct 2021, 6:00 pmClosed
Chief Engineer Rn D, Picket, Secunderabad, 500003
Chief Engineer Rn D, Picket, Secunderabad, 500003
PROVISION OF AUTOMATIC DOOR HANGER AND ADDITION/ALTERATION OF ADMIN BLOCK ANNEX IN LTF HANGER BUILDING AT CABS BANGALORE
2021_MES_466556_1
CA NO.CERD/BAN/TOKEN/51 OF 2019 -2020
Open Tender
Civil Works
Item Rate
365 days
Bangalore
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
GE I Rnd East Bangalore
₹4 L
Yes
12 Nov 2021
9 Aug 2021
25 Oct 2021
9 Aug 2021
18 Oct 2021
4 Oct 2021
Amount
Demolition of Reinforced Cement Concrete like Roofs, beams (other than ground floors) beams, staircases, landings, chajjas and similar suspended work not exceeding 15cm thick and removing rubbish complete all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles all as directed.
Taking down chowkhat with shutter [without taking off shutter from the frame] not exceeding 1.50 Sq.m each complete all as specified and as directed.
Taking down chowkhat with shutter [without taking off shutter from the frame] exceeding 1.5 Sqm but not exceeding 4.0 Sq.m each complete all as specified and as directed.
Taking down Shutters of any description exceeding 1.00 Sq.m but not exceeding 2.00 Sq.m each complete all as specified and as directed.
Dismantling of Ceiling board any description fixed in any position with screws complete all as specified and as directed.
Dismantling of wrought iron or Mild Steel work of any description like MS grills and similar items complete all as specified and as directed.
Re fixing only ( obtained from Item No.8 ) MS Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors,ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed.
Taking down existing plain or corrugated steel sheeting of any guage, thickness in roof and gate complete all as specified and as directed.
Excavating over area n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out as in soft/loose soil complete all as specified and as directed
Excavating over area exc 1.5 m but n.exc 3.0 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out as in soft/loose soil complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
M & L Plain cement concrete of grade M-10 in foundations, filling and mass-concrete as in drains complete all as specified and directed
Demolition of cement Concrete in ground floors and pavings exc 15 cm thickness (below or above ground level)
M&L for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm finishing road surface by belting complete all as specified and as directed.
Removal of demolished materials out side MD land to a distance exceeding 5KM and not exceeding 15.00 KM and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
Removal of excavated material [Soil] out side MD land to a distance exceeding 5KM and not exceeding 15.00 KM and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for 30mm thick Flush door solid core construction with veneer faced, black board core and ply wood face panels commercial type on both sides and both the faces are covered with decorative face veneer with lipping/frame to match . Bonding shall be with formaldehyde glue to ensure stronger bonding and longer life of door complete all as specified and as directed.
S & F 100mm long Butt hinges, medium weight cold rolled mild steel complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
M & L for providing Pre- cast cement concrete block masonry 1:3:6, Type C1 withsolid blocks, exceeding10cm in width and setting in motar, complete set in CM 1:6 complete all as specified and directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
S & F Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Framed work as in Joist,channel, angle, or Tee sectons, in roof truss fixed independently, without connecting plates,etc ( cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed.
S&F MS Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors,ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth at hight of 20 Metre including preparation of surfaces complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
M & L for Vitrified Tiles, Double Charged, light shade, First Quality, area of each tile exceeding 0.36 Sqm and not exceeding 0.42Sqm, 9 to 10 mm thick as in Floors, set and jointed in cement slurry, finished with flush pointing in white cement or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:6 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
S & F anodised Powder Coated ( thickness of powder coating not less than 50 Micron) Aluminium frame, Grill for doors and windows, ventilators, partitions with one or more rebates including jointing cleat, rubber beadingfor fixing, star lock etc complete all as specified and as directed.
S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in door shutters, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [2 Nos] per Shutter complete all as specified and as directed. Note: Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Locking Arrangement and fixing only of Panel inserts such as Glass / Gauge / Grills etc.
S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in Window and Ventilator Shutters, Sliding Type, without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No] per Shutter complete all as specified and as directed. Note: [a] Supply only panel inserts such as Glass / Gauge / Grills will be measured and paid separately. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Locking Arrangement and fixing only of Panel inserts such as Glass / Gauge / Grills etc.
M & L for 4.00 mm thick sheet glass ordinary quality in square not exceeding 0.50 Sq.m each pane glazing with oil putty complete all as specified and as directed.
All as per Item No. 34 here in above, but Exceeding 0.5 sqm in each pane
S & F in repairs 12mm thick, Prelaminated Particle Board, prelaminated on both sides with decorative choice lamination, exterior Gradefixed in aluminium partitions/doors with rubber beading complete all as specified and as directed.
S & F Black/Golden colour Solar control film 50 micron thick reflective type sticked to glass panes all as per manufacturer's instructions including taking down damaged filming complete all as specified and directed
M&L Coloured glazed ceramic tiles of grade B III size 450mm x 300mm x 7mm thick, in dado/skirting etc. set and jointed in neat cement slurry and pointed in epoxy grout to match, including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed
M&L Coloured Non Skid Joint less ceramic tiles of grade B II a / B II b of size 8 to 9 mm thick of size 400 x 400 mm, in floor etc. set and jointed in neat cement slurry and pointed in epoxy grout to match including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed complete
M & L for preparation of old painted steel and iron based surfaces of any description over 10cm width or girth and applying one coat of Synthetic Enamel paint complete all as specified and as directed. Note : The rate quoted shall include for necessary scoffolding as work to be carried out at height of biulding upto 20 Meter
S & F Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm and fixed with tinned tacks or stainless steel wire staples with new wooden beading including necessary painting to beading to match with existing surfaces complete all as specified and as directed.
S&F weld mesh of 4mm dia galvanised steel wire,50 x 50mm mesh,over angle iron frame made up into or cages, lapped, wired and laid in position, including necessary welding in all respects in repairs. Note :- (i) The height of the building is up to 20 m, should include for necessary scafolding and safety measures. (ii) Cast of Angle Iron frame if any will be measured separately.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut, not exceeding 5 cm long, dia of neck exceeding 5 mm but not exceeding 10 mm complete all as specified and as directed.
S & F Tie bars, roof truss and similar work with screwed ends, nuts, washers, and mild steel plates for walls, chimneys, roofs, arches, etc, king rods and strining bolts confirming to Fe-290, Gde -E-165 complete all as specified and as directed.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, GI clamps as in rain water down pipes complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F PVC (SWR) vent cowls 110mm bore complete all as directed.
S & F PVC (SWR) floor trap with 75mm dia outlet, plain with grating including jointing with solvent cement complete all as directed.
S & F PVC (SWR) gully trap125/110mm including jointing with solvent cement complete all as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
Taking down and refixing in the same opening shutters of any description exceeding 1.00 Sq.m and not exceeding 2.00 Sq.m each after easing and adjusting complete all as specified and as directed.
M & L for Brick work with Sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:4 complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Soft / Loose soil complete all as specified and as directed.
M & L for 5.50 mm thick sheet glass ordinary quality in square exceeding 0.50 Sq.m each pane glazing with oil putty complete all as specified and as directed.
S & F Vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm, White with integral foot rests and 'P' or 'S' trap 100 mm dia including provision of lime concrete bedding complete all as specified and as directed.
S & F PVC valve less, syphonic action type, flushing cistern, 10 Litres capacity, low level, white, with inlet, ball valve, float and handle, brackets complete including PVC outlet pipe all as directed.
S & F in repairs Flush pipe of polyethylene of low and high density of 32mm dia for low level cistern all as specified.
S & F in repairs Wash down water closet (Pedestal pattern), Vitreous China white(ETWC), plastic water closet seat (ETWC) of same colour closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Supply only plastic water closet seat, white closed pattern with flat bottom and cover and MS chromium plated or aluminised hinging device complete all as specified and as directed.y
S & F Urinal spreader of brass chromium plated for fitting with 15mm dia pipe in repairs complete all as specified and as directed.
S & F in repairs Vitreous china wash hand basin, white, angle back (Oval Type)of size 600 x 480mm excluding taps, waste, chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed
S & F 15mm dia Pillar taps, self closing, cast copper alloy, with long neck, chromium plated fancy type with aerator, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
M & L granite stone slabs of 18 to 20 mm thick as in floors and treads of steps etc including making holes and rounding exposed edges, with machine cut edges, rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of any colour / shade, design / pattern as directed, set and bedded with grey cement [slurry] and jointed and pointed with white cement slurry mixed with a admixture of pigment to match shade of granite slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
S & F in repairs brass CP bottle trap 32mm for WHB with inlet and outlet screwed for iron pipe or for brass ferrule and fixed for 15mm all as specified
S & F in repairs Bib taps, fancy type, 15mm bore, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed
S & F in repairs push cock 15mm , fancy type, chromium plated cast copper alloy complete all as specified
S & F Stop valves, 15mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and as directed
S & F in repairs PVC connection 15mm size 600mm long with PTMT nuts complete all as directed.
S & F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as directed.
S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete all as specified.
S & F Soap dispenser chromium plated complete all as specified and directed.
S & F in position chromium plated recessed type Toilet paper roller holder with flap of size 150x150mm with necessary CP screws and washers fixed to walls all as directed.
S & F in repairs Angle Cock, 15 mm dia,fancy type, Chromium Plated with long shank and cup, without flange complete all as specified.
S & F in repair 15mm dia stop valve concealed type cast copper alloy fancy type chromium plated with long shank and cup including making good to match with existing complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed
S & F Vitreous china urinal half stall type with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and Union for discharge pipe complete all as specified and directed.
S & F in repairs Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and as directed.
M & l for Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed
S & F in repairs Vitreous china urinal partition, white, of size 310 X 770 mm complete all as specified and as directed.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
S & F for pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm and base metal thickness of 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster on brick masonry surface in two layers, base layer 10mm thick in CM (1:4) and top layer 5mm thick in CM (1:4) (with river sand) mixed with WPC as per manufacture' s instructions, finished even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge. Note: WPC shall be measured and paid seperatly
M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in sub base to Foundation, Filling, Mass Concrete, Sunken Floors etc complete all as specified and as directed.
M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in foundations, rafts, footings, plinth beams, basement slabs etc complete all as specified and directed.
M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in beams, bands, cantilevers, lintels over 1.5M span complete all as specified and directed.
M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in chajja etc complete all as specified and directed.
M & L for RCC M-25 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc., complete all as specified and directed.
M & L for RCC M-25 (Design Mix) as in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M & L for RCC M-25 (Design mix) using 20 mm graded stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, water troughs, mangers, shelves and similar articles with plain faces, set in CM 1:4. complete all as specified and directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of plinth beams and similar work for rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of formwork (Rough finished) to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed.
Use and waste of formwork (Fair finished) to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, columns and similar work for rough finished surfaces of concrete square, rectangular or polygonal complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, lintels and similar work for fair finished surfaces of concrete flat complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including fair finished surfaces complete all as specified and directed.
Use and waste formwork to Edges of Concrete Flats, Treads, Breaks in Floors, Window Cills, Concrete Railings, openings in Concrete Walls, Floor and Roofs not exceeding 20cm wide and sides of RCC / PCC Bands in Walls, horizontal or sloping and similar work for fair finished surface of concrete complete all as specified and as directed
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S & F double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed.
S & F Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed.
M & L for 25mm thick, PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate as in floors/paving finished rough to receive cement tiles complete all as specified and directed.
M & L for Vitrified Tiles, Double Charged, light shade, Premium Quality, of size exceeding 0.36 Sq.m and not exceeding 0.42 Sq.m, 10 mm thick as in skirting, set and jointed in cement slurry and pointed in white or coloured cement to match the shade of the tile including screed bed or bedding layer of mortar 10 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Supply and fixing of ceiling system with fine figured edge tiles having humidity resistance (RH) of 95&. NRC 0.34 light reflectance approx 84 & thermal conductivity K-0.052 – 0.057. W/mk colour white fire performance of class-1 as per BS 476 part 6 & 7 in module size of 600 x 600 x 16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong or equivalent silhouette profile exposed grid system with 15mm white flanges incorporating 6 mm central reveal in white/black colour. Silhouette, main runners & cross tee to have mitred ends & birds mouth notches to provide mitred cruciform junctions. The Tee sections have a galvanizing of 170 hrs per sqm & passed through 500 hrs of salt test. The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using suspension system at 1200 mm maximum c/c. The first / last suspension system at the end of each main runner should be greater than 450 mm from adjacent wall. Cross Tee 1200 mm long should be interlocked between main runners at 600 mm module. 600 x 600 mm module is formed by fitting 600 mm long flush fitting cross Tee, perimeter trim consist of wall angles of size 3000 x 19 x 19 mm secured to wall screws at 450 mm c/c.complete all as specified and directed. Make: Arm strong / Saint Gobain
Taking down PVC (SWR) pipe 150mm borefrom trenches/ floors or fixed to wall complete all as directed.
S & F PVC (SWR) pipe 160mm bore, single socketed in any length with rubber ring joints including all fittings like bends and shoes etc laid in trenches/ floors or fixed to wall complete all as directed. Note: Height upto 20M and rate quoted deemed to include for necessary scaffolding
S & F PVC (SWR) bends 110mm bore, any radius complete all as directed.
Supply and fix brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing union cap and fixed 32 mm, in repair complete all as specified and directed
Dismantling of water tanks 1000 litres capacity and removing to store complete all as specified and directed
S & F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litres capacity, double layered, hoisted and fixed in position with polythene float and flynut complete all as specified and directed.
S & F GI tubing 25mm bore, medium grade with all fittings and fixtures fixed to walls and ceilings or laid in floors or in trenches including taking down complete all as specified.
S & F in repairs Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 25mm - 455 Grams] etc complete all as specified and as directed
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
Removal of entire existing water proofing treatment in any position including tarfelt, plaster and removing the debirs out side MD land all as specified and directed.
M & L for 25mm thick, PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate as in roof padding finished even and smooth complete all as specified and directed.
M & L for preparation of surfaces, brushing neat cement slurry with 3 KG of cement per Sq.m, screed bed 10mm thick in cement mortar 1:4 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound @3% by weight of cement for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.30 KG per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.50 Kg per Sq.m and minimum 3mm thick reinforced with polyester non-woven fabric of weight not not less than 160 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying two coats of auminium paint @ 100 ml per Sq.m for each coat on top for water proofing treatment including removing the rubbish from the site complete all as specified. Note: Water proofing compound will be measured and paid separately as " Supply only"
Supply only Integral Water Proofing compound
M & L for 75mm thick, PCC 1:3:6, Type C-2, using 40mm graded aggregate as in Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for complete removal of existing surface including preparation for applying Two coats or more coats of of 100% Acrylic premium Weather Proof Exterior Emulsion Paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance of required shade over and including a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed. Note: Height upto 20M and rate quoted shall be deemed to include for necessary scaffolding
M & L for preparation of newly plastered Wall surfaces and applying two or more coats of Cement based Wall Care Putty of 2mm on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one coat of alkali resistant primer on Wall surfaces complete all as specified and as directed. Note: Height upto 20M and rate quoted shall be deemed to include for necessary scaffolding
M & L for Complete removal of existing treatment of any description on Wall surfaces and applying two or more coats of Cement based Wall Care Putty of 2 mm on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall surfaces complete all as specified and as directed. Note: Height upto 20M and rate quoted deemed to include for necessary scaffolding
M & L for Complete removal of existing treatment of any description on ceiling surfaces and applying two or more coats of Cement based Wall Care Putty of 1.5 mm on ceiling including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall surfaces complete all as specified and as directed. Note: Height upto 20M and rate quoted deemed to include for necessary scaffolding
M & L for writing letters, painting Lines, Dashes, Arrows, Letters on galvalume sheet/ACP, height of letters not more than 1M etc white or golden yellow complete all as specified and as directed. Note: Height upto 20M and rate quoted shall be deemed to include for necessary scaffolding
S & F Anodised aluminium rectagular sections of 50x25x1.5mm size as in frame work for wall cladding fabricated to panels of size as directed and including necessary corner cleats etc to accommodate aluminium composite panel fixed to masonary walls/concrete/any other fabrications complete all as directed.
M & L for Galvanised iron angular bracket, 50x50x3mm size, for fixing the rectangular channel (provnon walls with holding bolt) complete all as specified and directed
S & F for pre-painted Galvalume steel Plain Sheets and thickness 0.50mm [Galvalume base-PPGL Sheets], having tensile strength of 550 Mpa, in ridges, hips, valley gutters, drip and straight flashing cut to length & bent to shape, girth sheets fixed with aluminium self tapping screws of size 50/75mm and neoprene and EPDM washers of suitable size in roof covering / cladding / eves trim / rake trim and closure trim / valley rain water gutter / down spouts and top rafters etc. complete all as specified.
M & L for 1200 mm dia RCC Pipes, Class NP 3, laid and jointed with collars laid in trenches and jointed set in cement mortar complete all as specified and as directed.
Alluminium composite panel, Metallic series of approved shade, the panel shall be of 5mm thick with combination of alluminium skin materials of 0.50mm thick alluminium sheet of alloy grade 1100 H cover material coated on exposed side with PVDF (Polyvinylidene fluoride) of KYNAR, PVDF coating containing 70% KYNAR 500 resine for antifungal & anti bacterial properties & the central core shall be natural polyethylene(LDPE and HDPE) bonded to alluminium skin on both sides cladding panel to be fixed with extruded alluminium basic frame 50x25x1.5 mm with angle cleats, weather sealants, revits, GI brakets all as approved using suitable bolts on walls including necessary acessories, scafolding, etc., complete for finished item of work and all as per manufecturer's instructions. all as specified & directed. Make -Erobond /Duro build/Aluco Bond/ Reyno Bond/ Lenox - make as approval by GE. Note :- Anodised aluminium rectangular section, GI brakets etc shall be measured and paid separately under respective items of this sch.
S & F for venetian blinds verical type 100 mm width with approved fabric and powder coated aluminium fittings such as top rails metal weight nylon button loops etc to match with the top rail metal base complete all as specified including dismantling unserviing one.
M&L for 2 mm thick epoxy resin based floor topping after priming the surface solvent base epoxy resin primer designed for maximum absorption with adhesion as per manufrature specification including prepartion of floor by wire brushing or light grit blasting to remove laitance, dust and cleaning the same to acheive machanical key between the floor and coating system and applying epoxy putty mixed with suitable fillers to cover the worn out areas all as specified and directed. Note :- (a) Floor topping shall be Nitoflor SL 2000 of M/s FOSROC/MASTERTOP TM 1215 PLUS of BASF or equivalent in CIPY. (b) Primer shall be Nitoprime 25 of M/s FOSROC or equivalent in BASF/CIPY. (c) Epoxy putty shall be Nitoflor FC 140/150 of M/s FOSROC or equivalent in BASF/CIPY.
S&F 30mm thick rigid PUF TR panel made out of profiled sheet on top and plain sheet at bottom with CFC free pentane blown polyurethane foam as the core (the core is CFC/HCFC free pentane blown polyurethane foam density of 40+2 kg /cum in 50mm thick sheet ) the panel sheet having 1000mm cover width , 34.5mm crest height @333mmc/c made out of 0.5mm TCT 300mpa stress , colour coated galvalume steel sheet 150 GSM aluminium zinc coated with 20 micron polyester paint , the sheet shall be fixed with self drilling self drilling seif tapping fasteners ,all as specified.Note: Height upto 20M and rate quoted shall be deemed to include for necessary scaffolding
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made of MS Sheet of suitable size as recommended by manufacturer and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. Note : Wherever point wiring is to be provided over concrete surface like ceiling/Columns/ Beams etc., the point wiring shall be provided with PVC conduit.
All as per Item No. 138 here-in-before, but for one 3 pin, 6 Amps switch socket outlet point on independent board, complete all as specified and directed.
All as per Item No. 138 here-in-before, but for one 3 pin, 6 Amps switch socket outlet point on same board for work bench complete all as specified and directed.
All as per Item No. 138 here- in- above, but for 5 pin 6/16amps socket outlet independently, with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 and including 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 as earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
Modular switch one way, 6 Amp, one module, (ISI marked), complete all as specified and directed.
Modular Socket 6A - 2/3 pin combined 2 module, (ISI marked), complete all as specified and directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 100 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F Socket Outlet, 2/3 pin, 6/16 Amps and combained Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Recess mounted full panel LED luminaire 35/36 watt fitting 2'x2' with white powder coated housing & frame in CRCA sheet, high effiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED colour temparature - 5700k, IP20, 50000 burning hours as per L70 criteria, ambient temparature - 0 to 50 Deg C, Driver efficiency >85%, THD<10%, PF>0.95, surge protection in CM-3KV, Multistage isolated constant current, Constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level< 60V DC as per IEC standard
S & F LED Luminaire not less than 22 Watt fitting 4' long with white powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, eletronic driver duly wired upto terminal block, CRI>80, LED colour temparature - 5700k, IP20, 50000 burning hours as per L70 criteria, ambient temparature - 0 to 50 Deg C, Driver efficiency >85%, THD<10%, PF>0.95, surge protection in CM-3KV, Multistage isolated constant current, Constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level< 60V DC as per IEC standard including batten/suspension system
S & F Energy efficient Sleek LED Mirror Light Fitting 2feet,10 watts decorative type driver holder and LED lamp with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F High bay LED light of 200W LED innovative die cast aluminium IP 65 luminaire with high efficency lighting with high power pre wired for LTF hanger including necessary accessories at site with safety belts/ chains al as specified and directed
S & F Infrared red bulb 3 pin 150 W 230 Volts including bulb holder for existing fitting in LTF hanger all as specified and directed
S & F Flood light fitting 200W PDC housing with IP 65 protection, applicable for large area of lighting including necessary fitting arrangement for LTF hanger with safety belts/ chains complete all as specified and directed
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including PVC casing and caping with all accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of PVC casing and caping accessories will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 650/1100 Volts with colour code , FRLS Grade, ISI Marked, drawn through and including PVC Concealed conduit accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of PVC conduit accessories will be measured as one unit.
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including PVC non matallic rigid conduit with accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of PVC conduit with accessories will be measured as one RM.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including PVC Concealed conduit accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of PVC conduit accessories will be measured as RM.
M & L for Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC rigid Conduit of minimum 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including Two runs of 16 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 6 runs of 16 Sq.mm & one run of minimum 32 mm dia PVC Conduit with accessories will be measured as one RM
M & L for Sub main wiring with 4 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawn through and including suitable PVC Concealed conduit accessories fixed on Walls / Roofs / Floors / Ceiling etc. and connecting terminal ends including Two runs of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, green in colour, 1100 Volts, FRLS Grade as earth continuity conductor complete all as specified and as directed. Note: 6 runs of 6 Sq.mm & one run of PVC condit with accessories will be measured as one RM.
S & F in repairs SP & N sheet metal Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20/32Amps, 240 Volts complete all as specified and as directed.
Taking out unserviceable street light bracket and supply and fixing Bracket suitable for street light fitting made out of 40mm dia, GI tubing medium grade 1.2m long, bent to shape, fixed with necessary nuts, bolts and 2 Nos clamps of size 40 x 6mm complete all as specified and directed.
S & F in repairs MCB DB, TPN, 8 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 6Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 4Way, 415 Volts, Double Door with 200 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F MCCB, TP, 100 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCCB, TP, 63 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S&F of MCB , TPN, 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps complete all as specified and as directed.
S & F MCB, TP, 25Amps to 32 Amps Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S&F of MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified and as directed.
S & F RCCB, four Pole, 100mA, 40 Amps for Earth Leakage, Overload & Short Circuit Protection 230 Volts, 50 Hz complete all as specified and as directed.
S & F Automatic modular contactor with manual over ride 4 pole , 40A AC 7 capacity, 415volts including connections complete all as specified and directed.
S & F copper conductor of size 1.5 Sqmm FR PVC round sheathed copper conductor FRLS cable, 1100V grade conforming to IS 694 multistanded, run on duct/concealed complete all spacified and directed.
S & F in repairs Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module complete all as specified and as directed. Note : Only sockets will be provided by MES
S & F in repairs LAN Outlet, RJ 45, UTP information outlet tool less, Modular Type, two Module, complete all as specified and as directed. Note : Only sockets will be provided by MES
S & F Cover plate with frame for telephone socket RJ-11 (Jac Type), Modular Type, two Module with Pressed Metal Flush Box made out of 2mm thick MS Sheet complete all as specified and as directed.
S & F Cover plate with frame for LAN cable RJ-11 (Jac Type), Modular Type, two Module with Pressed Metal Flush Box made out of 2mm thick MS Sheet complete all as specified and as directed.
S & F Aviation obstruction light fitting weather proof IP-65 protection, double red dome including LED lamp on the top of High rise Bldg/tower/ over head reservoir and testing and commissioning with 40/50mm GI pipe with acessories to fit the light fitting, and taking out unserviable aviation obstruction light fitting and connecting up complete all as specified and as approved. Note: Light fitting shall be of PF>0.95
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:3:6, Type C1 earthing chamber] Pit with precast slab 50mm thick in cement concrete (1:2:4) type B1, Reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/SqM , CI frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed. Note : Earth resistence not exceeding 2.0 Ohms
Supply, laying, jointing, testing and commissioning with all required jointing materials for LT under ground cable of size 185 Sqmm 3.5 core1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls / poles with proper size saddles and clamp laid under roads / path / drain / culverts or enclosed in GI pipe / fix complete all as specified and directed
Supply, laying, jointing, testing and commissioning with all required jointing materials for LT under ground cable of size 50 Sqmm 3.5 core 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls / poles with proper size saddles and clamp laid under roads / path / drain / culverts or enclosed in GI pipe / fix complete all as specified and directed
Supply & fix, laying, jointing, testing and commissioning with all required jointing materials for LT under ground cable of size 35 Sqmm 3.5 core, 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls / poles with proper size saddles and clamp laid under roads / path / drain / culverts or enclosed in GI pipe / fix complete all as specified and directed
Supply & fix, laying, jointing, testing and commissioning with all required jointing materials for LT under ground cable of size 25 Sqmm 3.5 core, 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls / poles with proper size saddles and clamp laid under roads / path / drain / culverts or enclosed in GI pipe / fix complete all as specified and directed
Supply & fix, laying, jointing, testing and commissioning with all required jointing materials for LT under ground cable of size 16 Sqmm 4 core, 1100 volts grade XLPE (cross linked polythene) armoured with galvanised round steel wire or steel strip, electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls / poles with proper size saddles and clamp laid under roads / path / drain / culverts or enclosed in GI pipe / fix complete all as specified and directed
S & F 14 SWG GI hot dip / powder coated perforated type tray for XLPE cable along wall to DB 100mm including all fitting accessories like Tee / saddles / all accessories required at site complete all as specified and directed complete all as specified and as directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming complete all as specified and directed. Note: For the purpose of payment the punned thickness only measured.
Supply & laying reinforced precast concrete covers class LV type 250x150x40 size factory made for cable protection complete all as specified and directed. Make: ISI mark.
M & L GI tube light grade with all fittings of size 80mm for protection of cables complete all as specified and directed.
Design, fabricate supply, install, test and commissioning of CPRI certified factory made LT panel indoor type conforming to IS / IEC-61439-1 & 2:2011 with canopy, louvers & shutters made out of 2mm thick CRCA sheet totally enclosed with necessary ventilation, weather, dust and vermin proof having copper bus bar of capacity 500 Amps TPN duly colour coded with heat shrinkable for internal connection with digital type volt meter 0-500 volt, ammeter 0-300 Amps including suitable range CTs for metering, duly wired with suitable size copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC type B1, MS channel, nuts, bolts, washers etc including control and consists of following: - (a) INCOMMER MCCB 4 P, 415V, 250 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 36 KA adjustable over load min 70-100% - 1 No. (b) OUTGOING MCCB 4 P, 415V, 200 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 36 KA adjustable over load min 70-100% - 1 No. (c) OUTGOING MCCB 4 P, 100 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 16 KA adjustable over load min 70-100% - 5 Nos. (d) LED indicating lamp (RYB) with all accessories (e) VAF Digital meter/panel at incoming with necessary wiring
Design, fabricate supply, install, test and commissioning of CPRI certified factory made LT panel indoor type conforming to IS / IEC-61439-1 & 2:2011 with canopy, louvers & shutters made out of 2mm thick CRCA sheet totally enclosed with necessary ventilation, weather, dust and vermin proof having copper bus bar of capacity 800 Amps TPN duly colour coded with heat shrinkable for internal connection with digital type volt meter 0-500 volt, ammeter 0-300 Amps including suitable range CTs for metering, duly wired with suitable size copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC type B1, MS channel, nuts, bolts, washers etc including control and consists of following: - (a) OUTGOING MCCB 4 P, 415V, 400 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 36 KA adjustable over load min 70-100% - 1 No. (b) OUTGOING MCCB 4 P, 415V, 200 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 36 KA adjustable over load min 70-100% - 1 No. (c) OUTGOING MCCB 4 P, 63 Amps, 50 Hz thermal magnetic release & Ics = 100% with rupturing capacity of 16 KA adjustable over load min 70-100% - 2 Nos. (d) OUTGOING MCB TPN 4 Pole, 415 V, 40A - 3 Nos. (e) Panel mounted change over switch 100A, 4 pole – 01 No. (f) LED indicating lamp (RYB) with all accessories. (g) VAF Digital meter/panel at incoming with necessary wiring
Earthing complete with galvanised iron plate electrode 600 x 600 x 6mm thick GI earthing lead buried directly in ground vertically to a depth not less than 2.25m deep below GL with the top edge of the plate at a depth not less than 1.5m from below normal GL connected to and including galvanised iron strip 32x6mm as earthing lead by means of nuts, bolts, washers, check nuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part-I of 2010 and as specified or indicated and testing on completion including excavation / earthwork in any type of strat PCC (1:3:6) type C1 earthing chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kgs of 40mm bore medium grade and lugs with and lugs, including GI earth strip with GI protection pipe of 40mm medium grade 7.5m long etc complete all as specified including testing and submission of test reports within permissible limit. Note: Earth resistance not exceeding 2.0 ohms.
Chemical earthing complete with copper earth plate of size 900 x 600 x 5mm buried directly and preferably vertically in ground with top edge not less than 1.25m below ground level connected with copper earth strip of 32x6mm connected to the earthing test point all as specified and directed by Engineer-in-Charge including testing and submission of test reports within permissible limit. Note: 1. The rates quoted are inclusive of copper earth strip upto the standard length and specified in the SSR Part-I. However, additional length will be measured and paid separately in respective item. 2. Earth resistance not exceeding 1.0 ohms.
Copper strip 32mm x 6mm buried in ground / on wall / floor with proceline saddles with test point complete all as specified and directed.
GI strip 32mm x 6mm buried in ground / on wall / floor with proceline saddles with test point complete all as specified and directed.
AFSON ENGINEERS & CONTRACTORS
M/S J J ENTERPRISES
Phoenix Infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .