SCHEDULE OF RATES- ELECTRICAL
CITY GAS DITRIBUTION PROJECT (CGS-2) DAHIYAR AT DARBHANGA GA BIHAR. - ELECTRICAL WORKS
Sr. No. | Activity/Item description | REV | C1 | Unit Rate
(Inclusive of all applicable taxes & duties except GST) | Total Amount
(Inclusive of all applicable taxes & duties except GST) | References
SUPPLY, INSTALLATION,TESTING&COMMISSIONING (SITC)
1 | Electrical Power Distribution Boards(DBs)
1.1 | MEDB(Main Electrical Distribution Board) - Supply, Design,Manufacturing,Assembly,Inspection,Testing at shop,packing of complete set of Electrical panel suitable for 415 Volt,3 phase neutral,4wire,50Hz,30kA AC supply, system fabricated in compartmentalized form from CRCA sheet steel not less than 2mm thick, duly treated with 7 tanks process, powder coated with approved shade and oven dried .The complete Electrical panels shall have a short circuit withstand capacity of 30kA for 1 second and IP42 rating.The panel shall have suitable arrangement for transfer to GG during mains failure and vice-versa when mains power is restored.The panel shall have a common copper earth bus of suitable size at the rear with 2Nos. earth studs, design as per drawings and documents, specifications,codes and standards and direction of consultant /owner (ref key single line diagram - C231104-CGSDAR-EL-SLD-4001).
Feeder details are as follows-
Incoming-1- 63A, 4P MCCB with μProcessor release
Incomer-2- 63A, 4P MCCB with μProcessor release
16A,4P MCB 03 Nos
16A TP MPCB 02 Nos
10A DP MCB 03 Nos
32A 4P MCB +40A FP Contactor with 5 Nos 6A DP MCB complete.
32A 4P MCB +32 A FP ELCB with 4 Nos 6A DP MCB and 4 Nos 16 A DP MCB complete. | Nos. |
2 | UPS and UPSDB
2.1 | Design, supply, manufacture, shop testing, inspection, packing, forwarding, delivery, testing and commissioning including supervision of testing and commissioning by equipment supplier at site, Including interconnecting cables among UPS, rectifier, battery, UPS DB, including commissioning spares as required of UPS systems as per specification, block diagram, recommended spares for 2 years operation and maintenance and following rating :
2.2 | Floor mounted single AC UPS system (Min Capacity 3 KVA) with UPS DB, Static switch Bypass switch as per the Tender specification. Refer PTS- AC UPS System and SLD
Floor mounted 1x100% maintenance free VRLA battery bank of 2 hour back up time with FLP Battery Junction box as per PTS- AC UPS System and considering aging, temperature & capacity factors complete with all interconnecting cables(among UPS ,Rectifier, battreybank, UPS DB), glands, battery cables, battery stands, AC distribution boxes, connectors & lugs etc as per the tender specifications for 3 KVA UPS. | Set |
3 | POWER CABLES
3.1 | Supply, laying, termination, testing and commissioning of 1.1kV grade, XLPE insulated, armoured power cable, control cable and signal cable, PVC inner sheathed, FRLS PVC outer sheathed (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
3.2 | 4Cx 25 mm2 A2XFY (AL), Power Cable, (Main incoming supply) | Mtrs |
3.3 | 4Cx4 sq.mm 2XWY Copper conductor, (ups and other loads) | Mtrs |
3.4 | 3Cx2.5 sq.mm 2XWY Copper conductor, (for UPS DB and lighting loads) | Mtrs |
3.5 | 5Cx 1.0 mm2 2XWY Screen | Mtrs |
3.6 | 2P x 1.0 mm2 2XWY Screen | Mtrs |
4 | Earthing and Lightning Protection System
4.1 | Supply, installation, testing, commissioning for complete earthing, earth electrodes/ pit, earth main ring, earthing of electrical equipment, instrument panels, field instruments, process equipment and pipes/ flanges including all associated civil works with all materials and labours as per specification and drawings approved by the company.
4.2 | Earth Pit - GI PIPE Electrode with 6 mm thickness chequered plate cover as per attached drawing | Nos. |
4.3 | Earth Pits- Copper plate Electrode(600 mm x 600 mm x 3 mm) with 6 mm thickness chequered plate cover as per attached drawing. UPS-2Nos, PLC-2 No. | Nos. |
4.4 | GI Strip(50x6)mm | Mtrs |
4.5 | GI Strip(25x3)mm | Mtrs |
4.6 | Copper Strip(25X3)mm | Mtrs |
4.7 | Supplying and Laying of Vehicle Cu. Earthing wire 25 sq. mm , 3 meters, Clip, reel & stand with complete with all accessories | Nos. |
4.8 | Providing and fixing 10 sqmm braided copper wire on surface or in recess for connection between end equipment and earth strip. | Mtrs |
4.9 | Supply,installation,testing & commissioning of lightning conductor finial made of 25mm dia 300 long GI tube having single prong at top with 85 mm dia 3 mm thick GI base plate including holes etc complete as required. | Nos. |
4.10 | 16 Ways Earthing Plate | Nos. |
5 | STREET LIGHTING POLES and OUTDOOR LIGHTING
5.1 | Supply, installation, testing, commissioning of lighting fixtures complete with mounting bracket, flame proof, control gear box as per the type of fixture, lamps etc. including pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
5.2 | Area lighting, integral flame proof well glass fixture (CMRI approved for Zone-1/2 gas group IIA & IIB, Temp. class-T3) with 110W LED luminaire with flame proof control gear of Baliga make or equivalent) | Nos. |
5.3 | Area lighting pole 7 mtr high GI octagonal pole (Type BOP-7030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box, cable from JB to fixture, flame proof gland, civil works and its materials including all labours and complete materials, as per standard drawing & specification | Nos. |
6 | INDOOR LIGHTING AND WIRING
6.1 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in recessed (including making chasing in the wall and repair of same) medium class PVC conduit as required. | Mtrs. |
6.2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, complete with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | Mtrs. |
6.3 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. | Mtrs. |
6.4 | Supply, Installation of 25 mm PVC Conduit for lighting | Mtrs. |
6.5 | Supply, Installation of 32 mm PVC Conduit for lighting | Mtrs. |
6.6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6.7 | 5/6 amps switch | Nos. |
6.8 | 15/16 amp switch | Nos. |
6.9 | 3 pin 5/6 amp socket outlet | Nos. |
6.10 | 6 pin 15/16 amp socket outlet | Nos. |
6.11 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | Nos. |
6.12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
6.13 | 3 Module (100mmX75mm) | Nos. |
6.14 | 12 Module (200mmX150mm) | Nos. |
6.15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | Nos. |
6.16 | Supply, Installation, testing & commissioning of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. | Nos. |
6.17 | Supply Installation of 6" fresh air fans with louvers for toilets/urinals | Nos. |
6.18 | 20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC complete with plug. Havells or equivalent | Nos. |
6.19 | Supply and fixing of Surface mounted 15 Watt LED light fitting of approved make complete with all accessories such as LED module, heat sink, diffuser/Reflector and driver set. Havells 15 W Edgepro Neo Surface Round LED Down Light or equivalent | Nos. |
6.20 | Supply and fixing of LED Tube Light 40 watt LED Philips Starbright 4 feet or equivalent.
Type of Product : LED Batten // Wattage : 40 W // IP Rating : IP20. | Nos. |
6.21 | 1.5 TON AC (5 star BEE Certified ) complete with MS stand for mounting outdoor unit, stabilizer(energy efficient).
Make as per approved vendor list | Nos. |
6.22 | Supply,Installation,Testing and commissioning of flameproof (CIMFR approved ) 12'' Exhaust fan, 0.25hP motor, 1440 rpm .Wiring to be done using 3 core FRLS cable .Switch to be placed outside the battery room. (Preferred make Baliga or equivalent) | Nos. |
6.23 | Supply,Installation,testing and commisioning of flameproof (CIMFR approved ) LED 40W tubelights for battery room .Wiring to be done using 3 core FRLS cable .Switch to be placed outside the battery room. | Nos. |
7 | CABLE TRAYS
7.1 | Supply, Installation, Erection of following Hot Dip Galvanized Ladder/Perforated Type cable trays (as per IS 2629) including bends, tee, crosses,horizontal, insert plate, tray supports and vertical splices etc. as required including supply of all G.I hardwares, civil works and its materials, all labour and material as required as per standard drawings, specification and direction of Engineer-in-charge.
Perforated type, with 50mm high side wall and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes
7.2 | 150 mm wide | Mtrs |
7.3 | 300 mm wide | Mtrs |
7.4 | Installations of cable route markers along the cable route at an interval of 20 metre as well as cable bends and joints. | Nos. |
8 | HDPE CABLE CONDUIT
8.1 | Supply and laying of following sizes of HDPE Pipe in required length fixed on steel, concrete or similar structure, laid in trenches, digging, construct conduit ductbank and buried in concrete including cutting, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., civil works and its materials, including all labour and materials complete as per approved drawings and directions of Engineer-In-Charge.
8.2 | 50mm NB | Mtrs |
8.3 | 100 mm NB | Mtrs |
9 | GG SET with AMF PANEL
9.1 | Supply installation, testing and commissioning of natural Gas engine generator with AMF panel as per following requirements and as per VCS standard specification VCS-SS-EL-4004 and Datasheet VCS-DS-EL-4004. Gas engine generator shall meet CPCB IV+ norms.
The Gas Engine shall be suitable for generating set application developing minimum 83 HP at 1500 RPM under NTP conditions of BS: 5514 or equivalent in IS, turbocharged, water cooled, with after radiator, Engine to be sufficient for alternator 58.5 KVA at 0.8 pf (lagging) i.e., 46.8 KW. Starting System : 12 V battery operated electric motor starting. Starting system shall be capable of three successive starts. Battery type: sealed SMF. The engine shall be supplied complete with coupling, guard, as well as outlet exhaust pipe with silencer.
Alternator with rated output of 58.5 kVA at STP suitable for continuous operation at 1500 RPM developing 415 volts at 0.8 p. f. (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless type, drip proof, screen protected as per IP-23, self excited & self regulated. The alternator will be suitable for tropical climate and shall conform to IS:4722.
AMF panel (automatic mains failure panel) control suitable for 58.5 KVA Gas Engine genrator complete with relays, timers, set of CTs for metering to indicate currents,phase and line voltages, frequency, power factor, KWH etc.
10 | SAFETY MATERIALS
10.1 | Supply and installation of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required, and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
10.2 | CO2 fire extinguishers(4.5kg) | Nos. |
10.3 | 4 sand Buckets with stand . | Nos. |
10.4 | Caution boards (Danger, High Voltage) including supply of necessary clamps, bolts and other hardware.
SUPPLY AND INSTALLATION OF VITREOUS ENAMEL CAUTION BOARDS SUITABLE FOR 440 V AS PER IS 2551 INCLUDING FIXING ON THE WALL WITH ALL THE REQUIRED HARDWARE ETC.COMPLETE IN ENGLISH / HINDI/ LOCAL LANGUAGE. Size 200mmx250mm | Nos. |
10.5 | Shock hazard charts complete with frame and glass. Size A3 and glass thickness 2mm | Nos. |
10.6 | Single Line Diagram complete in glass frame.Size A2 and glass thickness 2mm | Nos. |
11.1 | Rubber hand gloves suitable for 440 volts | Pairs |
11.2 | Philips head screw driver of each size 3mm,3.5mm,5mm | Set |
11.3 | Flat head screw driver of each size 3.5mm,5.5mm,6.5mm | Set |
11.4 | Line Tester suitable for 3 phase,440 volts | Nos. |
11.5 | Open end Spanner set of size(6mm-17mm) | Set |
12 | First Aid kit
Supply of Small First Aid kit conforming to India Red Cross Society and comprising of:
1 tube silver sulfadiazine ointment 15 g; 10 band aid strips; 1 roller bandage 5x5 cm
1 package absorbent sterilized cotton 15 g; 1 scissor 7cm (sharp/blunt edge)
10 tablets paracetamol; 1 plastic mouth-to-mouth resuscitator; 1 triangular bandage (90 cm)
10 safety pins; 1 adhesive plaster/tape; 3-4 ice cream spoons to be used as splints of finger
2 ORS sachets; 10 sterilized finger dressings; MEDIUM FIRST AID BOX; | Nos. |
13 | INSULATING MATS
13.1 | Supply and laying of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to, required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge, as per applicable Indian or International standards and Indian Electricity Rules. | Mtrs |
14 | DISTRIBUTION TRANSFORMER
14.1 | Supply,Installation,Inspection,Transportation to site,erection on pole,testing and commissioning of 11kV/433V outdoor type, 3 phase,50Hz,copper wound, ONAN distribution transformer complete with all accessories as per IS2026/1180 and latest ammendments and there of and first oil filled.Termination arrangements for HV side: HT bushing &LV side cable end box /terminal box of following rating.
Scope also includes Supply erection, testing and commissioning of all the items including transformer, all miscelleneous materials required, digging trenching,backfilling,compaction,making of foundations/pedestal,fixing the fencing and gate,spreading of blue granite material etc as required to complete the HT & LT installation as per the tender.(All electrical equipment shall be approved from state electricity board /VCS).
14.3 | Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating; pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection between the OH Line & HT bushing of transformer, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation. | Set |
14.4 | Supply, erection and commissioning of 11 kV, ACSR weasel conductor as required for stringing between State Electricity Board Double pole and consumer double pole structures including supply and erection of pole, crossarm, pin insulator etc. | Mtrs |
14.5 | Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x2.5 mtr.) complete with all material, welding and labour | Mtrs |
14.6 | 40 mm blue granite metal for spreading in the fenced area . | Mtr3. |
14.7 | Supply and laying of 3 core x 25 Sq mm, 11 kV HT cable, XLPE Insulated and PVC sheated, Screened, Armoured cable | Mtrs |
15 | EMERGENCY SHUTDOWN BUTTON
15.1 | Supply &Installation of emergency shutdown butons with latching lift flap, flameproof type (Zone 1&2 and Gas group IIA & IIB) and weatherproof enclosure IP65,quick release provision, NO NC contacts to trip all the incomers simultaneously of the main electrical distribution board and UPS distribution boards incomer.Location of installation to be decided during detailed engineering. | Nos. |
SCHEDULE OF RATES, INSTRUMENTATION
CITY GAS DISTRIBUTION PROJECT OF (CGS-2) DAHIYAR AT DARBHANGA GA BIHAR - INSTRUMENTATION WORKS
ITEM NO. | WORK DESCRIPTION | UNIT | QUANTITY | REV-C1 | REFERENCES
(INCLUSIVE OF ALL APPLICABLE TAXES & DUTIES, FREIGHT, TRANSIT INSURANCE AND ANY OTHER INCIDENTAL COST) EXCEPT GST
(INR) | TOTAL AMOUNT
(INCLUSIVE OF ALL APPLICABLE TAXES & DUTIES, FREIGHT, TRANSIT INSURANCE AND ANY OTHER INCIDENTAL COST) EXCEPT GST
WORKS FOR (CGS-2) DAHIYAR AT DARBHANGA GA BIHAR (INSTRUMENTATION)
Supply, Calibration and Installation of instrumentation items listed below:
(For details, refer instrumentation specifications)
IN001.01.01 | Supply, Installation, Testing & Commissioning of Pressure Gauge as per Datasheet, Specifications and P&ID
Supply, Installation, Testing & Commissioning of SS-316 Pressure Gauge of 150mm(6 inch) Dial Size , C-Type Bourdon Tube, Solid Front Type with 2 Way Manifold, direct mount as per the Datasheet attached with the Tender Document. | Nos. |
IN001.01.02 | Supply, Installation, Testing, Calibration and Commissioning of Pressure Safety Valve (PSV) as per specs,data sheets, PMS & P&IDs.
Pressure safety valve shall be conventional type, (Inlet/Outlet Size & Rating): (Hold), Bonnet Type: Closed, Case selection: Block Discharge. along with all necessary accessories as per installation standard, data sheet, standard specification and P&ID attached with this tender. | Nos. |
IN001.01.03 | Supply, Installation, Testing, Calibration and Commissioning of Self Actuated Pressure Reduction Valve (CPV) as per specs,data sheets, PMS & P&IDs.
Self actuated pressure reduction valve shall be of Carbon steel body suitable for Gas service/pipe spec with SS internals along with all SS tubing fittings etc. Inclusive of supply and installation of necessary accessories as per the data sheet, standard specification and P&ID attached with this tender. | Nos. |
IN001.01.05 | Installation,Testing & Commissioning of Direct Gas Actuated Valve (DGAV) including assembly of SS tube/fittings
SS Tube Connection, Testing and Commissioning of Direct Gas Actuated Ball Valves (DGAV) including the Supply and installation of SS tubes and fittings along with supports for impulse lines (wherever required), painting of supports as per std., manifold/ isolation valves, sockolets etc as required for tubing of each Valve, as per the direction of Engineer-In Charge / site supervisior but exclusively for supply of Valves with actuator. | Nos |
IN001.02.00 | Gas Detection System (GDS)
Supply, Configuration, Installation, Testing and Commissioning of Gas Detection System including Gas Detectors (Point Type) ,Hooter, Beacon, MCP ,Control Unit.
Gas Detector Control Unit shall be installed on GDS Panel located at CGS-2 DAHIYAR Building .
Refer below details:
IN001.02.01 | Supply, Installation, Testing & Commissioning of Addressable type 8-Channel Gas Detection System Panel (600mm X 400mm) including Gas Detector Control Unit. Gas Detector Control Unit shall be installed on GDS Panel located at CGS Control Room Building. | Nos. |
IN001.02.02 | Supply, Installation, Testing & Commissioning of Point Gas Detector - IR type Type, 4-20 mA HART, 2 wire 24 VDC loop powered Ex 'd', IP 67, SIL-2 Certified, Enclosure material SS316 with display, range 0-100% LEL point hydrocarbon gas detector. | Nos. |
IN001.02.03 | Supply, Installation, Testing & Commissioning of Hooter, electronic Multitone tone, 24 VDC Power Supply, IP-66, Ex'd' with epoxy coated aluminium housing material suitable for outdoor Hazardous area application complete with wiring and accessories. | Nos. |
IN001.02.04 | Supply, Installation, Testing & Commissioning of Beacon (LED Type) Discharge Lamp, 24 VDC, Ex 'd', IP 66, Enclosure MOC- SS316, outdoor Hazardous area application complete with wiring and accessories. | Nos. |
IN001.02.05 | Supply, Installation, Testing & Commissioning of Manual Call Point break glass type with nickel plated brass hammer & SS Chain , 24 VDC Power Supply, IP66, Enclosure MOC- Stainless Steel or Alloy suitable for outdoor hazardous area application. | Nos. |
IN001.03.00 | Fire Alarm System
Supply, configuration, testing, installation, erection and commissioning of Addressable Type Fire Alarm System including Fire Alarm Control Panel, Detectors, MCP, hooter, panel and cables.
FACP shall be installed inside control building of respective CGS-02 DAHIYAR Building as per Technical Specification of the tender.
IN001.03.01 | Fire Alarm Control Panel (FACP)
Supply, Installation, Testing & Commissioning of Analogue Addressable Fire Alarm Control Panel with Repeater Panel (If Required in Gaurd Room), installed in CGS Control Room complete with battery backup and accessories, interfaces with RTU and inclusive of cabling, termination etc. | Nos. |
IN001.03.02 | Supply, Installation, Testing & Commissioning of Smoke Detectors ((Addressable type) with Response Indicator Combination of (Ionization+Photoelectric) complete with wiring and accessories for installation inside the Control Room/Electrical Room/Guard Room as per Tender datasheet. | Nos. |
IN001.03.03 | Supply, Installation, Testing & Commissioning of Heat Detector with Response Indicator (Addressable type, IP - 42 Protection Class), complete with wiring and accessories for installation inside the Control Room/Electric Room/Battery Room as per Tender datasheet. | Nos. |
IN001.03.04 | Supply, Installation, Testing & Commissioning of Manual Call Point (Indoor Application) complete with wiring and accessories as per Tender datasheet. | Nos. |
IN001.03.05 | Supply, Installation, Testing & Commissioning of Conventional Sounder / CUM Strobe, Power Supply 24VDC, 3 Tone, Xeon Flash Tube, Enclosure Material- FR ABS Plastic Red complete with wiring and accessories. | Nos. |
IN001.04.00 | CCTV System for CGS-2 at DAHIYAR Building.
Supply, Installation, Testing & Commissioning of CCTV System including CCTV Cameras, PoE Ethernet Switches, CCTV Workstation, Network Video Recorder (NVR) and Server Rack, CCTV Mounting Stantion/Pole.
IN001.04.01 | Supply, Installation, Testing & Commissioning of IP PTZ camera (for process area) day Night HD (1080P) explosion proof with required connecting patch cords, wall/pole mount installation accessories as per technical specification. PTZ camera shall be powered by PoE switch via Cat6 cable | Nos. |
IN001.04.02 | Supply, Installation, Testing & Commissioning of IP Dome Type (Inside the Control Building) camera HD (1080P) IP42 with required connecting patch cords, wall/Celling mount installation accessories as per technical specification. Dome camera shall be powered by PoE switch via Cat6 cable. | Nos. |
IN001.04.03 | Supply, Installation, Testing & Commissioning of IP Fixed camera (For entry & Emergency gate) day Night HD (1080P) explosion proof with required connecting patch cords, wall/pole mount installation accessories as per technical specification and shall be powered by PoE switch via Cat6 cable. | Nos. |
IN001.04.04 | Supply, Installation, Testing & Commissioning of PoE Ethernet Switch 8 port with connecting patch cords, Pigtails and other required accessories as per technical specification. | Nos. |
IN001.04.05 | Supply, Installation, Testing & Commissioning of LCD Display unit (24"), Keyboard with Joystick along with required cables, connectors, interfaces complete as per technical specification. | Nos. |
IN001.04.06 | Supply, Installation, Testing & Commissioning of 8 Port Compact Network Video Recorder (NVR) with (4TB) of 30 days recording, connecting patch cords, Pigtails and other required accessories cameras as per technical specification. | Nos. |
IN001.04.07 | Supply, Installation, Testing & Commissioning of Wall Mounted Rack: 600mmwidth/800mm Depth for installation of NVR and other related equipments as per technical specification. | Nos. |
IN001.04.08 | Supply and Installation of CCTV Mounting Stantion/Pole, mounting fittings and accessories etc. as required | Nos. |
IN001.05.00 | Cables, Cables Trays and Junction boxes for CGS-02 DAHIYAR Building.
Supply, laying in tray/tenches, testing, erection of armoured signals cable from field instruments to junction boxes including termination, glanding, ferruling, dressing etc at both ends.
Supply of cable trays, cables glands, junction boxes, erection materials, cable ferrules, cable lugs, cable ties.
Supply, Installation and erection of cable trays and junction boxes.
IN001.05.01 | 2P X 1.5 Sq.mm ‘IS’ Twisted Pair, Individual & Overall Screened shall be of XLPE.CS.PVC.SWA.PVC/ Blue | Mtr. |
IN001.05.02 | 2P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | Mtr. |
IN001.05.03 | 6P x 1.5 Sq.mm, ‘IS’ Twisted Pair, Individual and Overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant / Blue | Mtr. |
IN001.05.04 | 6P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | Mtr. |
IN001.05.05 | 8P X 1.5 Sq.mm ‘NIS’ Twisted Pair, overall screen shall be of XLPE.CS.PVC.SWA.PVC/ Flame retardant/ Black | Mtr. |
IN001.05.05 | 1T X 1.5 Sq. mm, Fire resistant,Over all Screened Cables | Mtr. |
IN001.05.06 | 8T X 1.5 Sq.mm Fire Resistant Individual & Overall Screened, Twisted Pair overall screen shall be of XLPE.CS.PVC.SWA.PVC/Red | Mtr. |
IN001.05.07 | 2C X 1.5 Sq.mm, Fire Resistant, Overall Screened/Black | Mtr. |
IN001.05.08 | 8C X 1.5 Sq.mm, Fire Resistant, Overall Screened/Black | Mtr. |
IN001.05.09 | CAT-6 CCTV CABLE | Mtr. |
IN001.05.10 | RS 485/ SERIAL LINK CABLE | Mtr. |
IN001.05.11 | Field mounted Fire (Analog) Junction box (FAJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (01 Nos. M20, 1 No. M25, 01 Nos. M32 & 01 Nos. M40 x1.5), 24 Terminal Block. | Nos. |
IN001.05.12 | Field mounted Fire (Digital) Junction box (FDJB) Ex‘d’ Type (Explosion Proof), 12 Nos. cable Input (1/2" NPTF) and 4 Nos. cable output (01 Nos. M20, 1 No. M25, 01 Nos. M32 & 01 Nos. M40 x1.5), 24 Terminal Block. | Nos. |
IN001.05.13 | Cable Trays (150 mm x 50 mm, Perforated Type, GI Tray) | Mtr |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
23769.pdf
pdf • 46.41 MB
BUDGETDOC_23769.xlsx
xlsx • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .