| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹49.0 L+₹10.3 L (26.6%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 Jan 2020, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPECIAL REPAIR TO ET-48 (RATION STORE), ET-373 A (OFFICE BLOCK), ET-36 (CLOTHING AND EQUIPMENT STORE), ET-463 (GUARD ROOM) AND OTHER SANCTIONED WORKS AT TAMULPUR AND DARRANGA UNDER GE RANGIA
2019_MES_306395_1
8337/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
TAMULPUR AND DARRANGA
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE RANGIA
₹98,000
Yes
4 Feb 2020
13 Dec 2019
8 Jan 2020
13 Dec 2019
6 Jan 2020
28 Dec 2019
Amount
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators, DBs, MCBs, etc. and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc, complete all as per specified and as directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLS copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLS copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per Serial item No. 02 above but for one fan point controlled by one way switch.
All as per Serial item No. 02 above but for one 3 pin socket outlet 5 AMPs on independent board
All as per Serial item No. 02 above but for one 3 pin socket outlet 5 AMPs on same board
All as per Serial item No. 02 above but with 4 sqmm (nominal area) cable with 4.0 sqmm size copper earth continuity conductor for 3 pin 15 Amps socket out let on independent board.
Supply and fix switch piano flush type, 6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet, 5 pin 6 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 6 Amp 5 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 05/16 Amp 6 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix fan regulator electronic type, rotary step, Socket type 240 Volt, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED light fitting single tube 1 X 22 Watts, 240 V surface and wall mounted led batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper contactor cable with 1.5M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F Security light fittings 1x 15 Watt LED New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP openning seperate driver compartment with IP65 protection and impact resistance of IK07 and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosure for double door SPN 8 Ways DB when MCBs to be used single pole neutral 240 Volts with 200 A Bus Bar, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB SPN 40 Amp 10KA braking capacity 230/240 volt AC, complete all as specified and as directed by Engineer-in-charge.
S & F MCB single pole, 240 volts, 6 - 32 Amps, 10 KA, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep and getting out in soft/loose soil, complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250 mm in soft/loose soil, complete all as specified and as directed by Engineer-in-charge.
Removing excvated materials (soils) not exc. 50.00 M and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Taking down/up XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade of size 16 sqmm 2 corecomplete all as specified and as directed by Engineer-in-charge.
S&F XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of size 16 Sqmm 2 Core including testing, complete all as specified and as directed by Engineer-in-charge.
Taking up/down GI pipe 25 mm bore from wall/floor/trenches used for cable protection, complete all as specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 25 mm bore light grade for protection of UG cable, complete all as specified and as directed by Engineer-in-charge.
S & F ceiling fan hook made out of MS flat 50 X 6 mm thick suitable for hanging of ceiling fan including nuts, bolts and washer with 12 mm dia round bar hook after taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply, installation & commisioning of water cooler having fully stainless steel body, 120 Ltr storage capacity, 60 Ltr/hour cooling capacity, CFC-free refrigerant, single phase, electric driven, complete all as specified and as directed by Engineer-in-charge.
S&F 3 KVA capacity of volatge stabilizer for automatic operation, single phase, naturally air cooled, designed for input voltage variation between 170V to 250V with output volatge stabilized at 230V with accuracy of +/- 2.5%, complete all as specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 20 mm bore medium grade fixed on wall/floor/trenches, complete all as specified and as directed by Engineer-in-charge.
Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and as directed by Engineer-in-charge.
M&L for 2nd class hard wood in scantling wrought timber un-framed and fixed complete all as per specified and as directed by Engineer-in-charge.
S&F Mild steel work in hand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O, complete all as per specified and as directed by Engineer-in-charge.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or 'J' hooks complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks complete all as per specified and as directed by Engineer-in-charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness, including cover fillets, complete all as per specified and as directed by Engineer-in-charge.
M&L for 4mm thick Non Asbestos fiber Cement Designer E- board ceiling of size (595x595)mm fixed in powder coated Anodised aluminium frame (snapgrid) of standard section as per manufacturers instructions with the 3mm thick GI suspender in ceiling and applying on one coat of distemper oil emulsion, complete all as per specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as per specified and as directed by Engineer-in-charge.
M&L for G.I. Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as per specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as per specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in any cement mortar including all quoins, arches, pillars, etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15 mm thick in cement mortar (1:4) finished even and smooth without using extra cement on wall surfaces or on one side of lathing, complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick on other than fair faces of brick work or other side of lathing in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of oil bound distemper on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old painted surface of walls including washing, rubbing down and stopping and applying one coat of cement based paint on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old painted surface of walls including washing, rubbing down and stopping and applying one coat of oil bound distemper on surfaces of walls, complete all as per specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as per specified and as directed by Engineer-in-charge.
S & F Second class hard wood plain wrought fillets square, rectangular or triangular in section, bull nosed splayed chamfered or rounded on one edge or face sectional area exceeding 13 Sqcm and not exceeding 25 Sqcm fixed with screws, complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings not exc. 15 cm thickness, complete all as per specified and as directed by Engineer-in-charge.
M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in footpath/ hard-standing / pavings / plinth protections, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L 40 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for Glass dividing strips, 38 x 3 mm thick and inserted in position to confirm to design, complete all as per specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificied provided for, complete all as per specified and as directed by Engineer-in-charge.
M&L for precast RCC posts with 1:2:4 concrete Type B1 (Using 20 mm graded stone aggregate) sectional area exceeding 100 but not exceeding 250 Sqcm, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises, complete all as per specified and as directed by Engineer-in-charge.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item no. 64 above but on vertical surfaces such as skirting, dado, etc. over 10 mm thick rendering in CM 1:4.
Taking down shutters of any description not exceeding 1 Sqm each complete all as per specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both side, complete all as per specified and as directed by Engineer-in-charge.
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., without sash bars , edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Pt I Section 8, clause 8.24 (a), complete all as per specified and as directed by Engineer-in-charge.
S & F 30 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., without sash bars , edges of framing plain, chamferesd or rounded, fitted with cut and mitred beads for securing glass etc., for windows and ventilators, etc are provided with (stiles and rails 80mm,muntins 60mm & glazing bars 45mm wide) as specified in SSR Pt I Section 8, clause 8.24 (b), complete all as per specified and as directed by Engineer-in-charge.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges complete all as per specified and as directed by Engineer-in-charge.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as per specified and as directed by Engineer-in-charge.
S&F 125mm Aluminum anodised barrel tower bolts of extruded section complete all as per specified and as directed by Engineer-in-charge.
S&F 150mm Aluminum anodised barrel tower bolts of extruded section complete all as per specified and as directed by Engineer-in-charge.
S&F 125mm anodised aluminium handles fabricated type complete all as per specified and as directed by Engineer-in-charge.
S&F 150mm anodised aluminium handles fabricated type complete all as per specified and as directed by Engineer-in-charge.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as per specified and as directed by Engineer-in-charge.
S & F 3 mm thick Sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosote oil, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of newly untreated wood or wood based surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coat of Synthetic Enamel paint over a coat of pink primer complete all as per specified and as directed by Engineer-in-charge.
S & F in repair Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
M&L for providing precast cement concrete 1:2:4, type B0 (using 12.5mm graded stone aggregate) as in louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4 complete all as per specified and as directed by Engineer-in-charge.
S & F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F Coloured Glazed ceramic tiles 300 x 450 x 7 mm thick on floors and jointed in neat cement slurry and pointed in white or Coloured cement to match with the shades of tiles over 15 mm thick screed bedding layer in CM 1:6, complete all as per specified and as directed by Engineer-in-charge.
Taking down Chowkhats or frames n.exc 1.5 Sqm but with shutters of any description ( without taking off shutters from the frames), complete all as per specified and as directed by Engineer-in-charge.
M&L for steel windows with side hung shuttres including projecting type hinges with steel handle and steel peg stay ,complete with glazing bars,dovetailed or welded, complete all as per specified and as directed by Engineer-in-charge.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc. 0.50 Sqm in each pane, complete all as per specified and as directed by Engineer-in-charge.
S&F 300 mm long mild steel Helical door Spring of approved quality, complete all as per specified and as directed by Engineer-in-charge.
S&F PVC 10 ltr capacity low level flushing cistern white with inlet ball valve float and braket and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair PVC 10 ltr capacity low level flushing cistern white with inlet ball valve float and braket and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm bore CP angle stop cock with fitting sleeve, operating lever & adjustable wall flange with seal screwed down high pressure with crutch or butter fly handle screwed both end for iron pipe, complete all as per specified and as directed by Engineer-in-charge.
S & F Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand and waste coupling of size 32 mm and waste pipe 32 mm, etc., complete all as per specified and as directed by Engineer-in-charge.
S & F in repair 15 mm bore stop cock, fancy type, chromium plated screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions, complete all as per specified and as directed by Engineer-in-charge.
S & F 15 mm bore stop cock, fancy type, chromium plated screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions, complete all as per specified and as directed by Engineer-in-charge.
S&F 20 mm dia ball valve, PTMT high pressure of epoxy coated Aluminium rod and high density plastic ball (200 gms), screwed for iron pipes or brasas ferrule, complete all as per specified and as directed by Engineer-in-charge.
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe, complete all as per specified and as directed by Engineer-in-charge.
S & F chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
S & F fancy type 15 mm bore chromium plated bib tap cast copper alloy, screwed for iron pipe or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm dia PVC connection pipe with PTMT nuts of length 450mm, complete all as per specified and as directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F 110 mm dia bore PVC (SWR) bends, complete all as per specified and as directed by Engineer-in-charge.
S&F 110 mm dia bore PVC (SWR) junction (single T) equal or un-equal, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surfaces of any description, not exc.10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as per specified and as directed by Engineer-in-charge.
S & F Soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm palin colour PVC sheet reinforced with MS square tube, suppling and fixing in opening as per specification and drawing including taking down old unserviceable PVC frame with shutter, complete all as per specified and as directed by Engineer-in-charge.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing, complete all as per specified and as directed by Engineer-in-charge.
S&F flat iron fillets ( for securing wire mesh etc), wind ties etc including all necessary drilling bolting or riveting, etc, and similar work confirming to Fe-290 Gde E-165, complete all as per specified and as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position, complete all as per specified and as directed by Engineer-in-charge.
S&F Vitreous china urinals, bowl type flat back size 465 x 355x 265 mm whiten minimum with grating and union for discharge pipe , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal pot backing with cement complete.
M&L precast Coloured cement concrete chequered tiles 300x300x25mm thick set jointed and pointed in with grey cement and pigment laid over and including 20mm thick screed bed in CM 1:6 in floorings, complete all as per specified and as directed by Engineer-in-charge.
Surface dressing not exc. 15 cm deep in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, in CM 1:6 straight or curved on plan exc. 6m mean radius, complete all as per specified and as directed by Engineer-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) as in beams, lintels etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M & L for 100 mm thick cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of flooring/hard standing, complete all as specified and as directed by Engineer-in-charge.
M&L, 100 mm thick cement concrete type B-1, 1:2:4 type (using 20 mm graded crushed stone aggregate) as in pavement/ hard-standing surface finished fair and even, complete all as per specified and as directed by Engineer-in-charge.
M&L for Machine cut kota stone slab flooring 20 - 25 mm thick over 20 mm thick cement screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing complete all as per specified and as directed by Engineer-in-charge.
M&L for rolled mild steel as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15 mm thick in cement mortar (1:6) finished even and smooth without using extra cement on wall surfaces, complete all as per specified and as directed by Engineer-in-charge.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) as in columns, pillars, piers, posts and struts etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel ventilators with top hung shutter including hinges, steel peg stay, complete all as per specified and as directed by Engineer-in-charge.
M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade set jointed and pointed with grey cement and no pigment, complete all as per specified and as directed by Engineer-in-charge.
M&L for construction of soakage wells including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM 1:4, RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M Dia X 3.00 M effective depth, complete all as per specified and as directed by Engineer-in-charge.
M&L for concrete bed 1:3:6 type C2 (40 mm graded stone aggregate) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as per specified and as directed by Engineer-in-charge.
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) as in precast slabs, etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for Loose filling with aggregates (broken bricks) of gauge 80 to 150 mm in soakage pits, soakage wells, complete all as per specified and as directed by Engineer-in-charge.
M&L for construction of manholes with 150 mm dia bore for connecting new drains making good to pipe, rendering, benching, forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished as required as per Drawing No.- CESZ/TD/40, complete all as per specified and as directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc. 50 m and making good surfsce in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
M&L for rolled mild steel Fe-410-W(Gde-E-250) quality-B for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for plastic dividing strip, 38 x 1.5 mm thick and inserted in position to confirm to design, complete all as per specified and as directed by Engineer-in-charge.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 18 sqm but not exceeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6, complete all as per specified and as directed by Engineer-in-charge.
All as per serial item no. 139 above but on vertical surfaces such as skirting, dado, etc. over 10 mm thick rendering in CM 1:4.
M & L for 75 mm thick cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base, complete all as specified and as directed by Engineer-in-charge.
M&L, 100 mm thick cement concrete type B-2, 1:2:4 type (using 40 mm graded crushed stone aggregate) as in pavement/ hard-standing surface finished fair and even, complete all as per specified and as directed by Engineer-in-charge.
M&L, 100 mm thick cement concrete type B-2, 1:2:4 type (using 40 mm graded crushed stone aggregate) as in pavement/ hard-standing surface finished fair and even using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for 25 mm thick cement concrete type B0, 1:2:4 (using 12.50 mm graded stone aggregate) as in floors, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
S&F Coloured Glazed ceramic tiles 300 x 450 x 7 mm thick on vertical surfaces such as skirting, dado, etc. and jointed in neat cement slurry and pointed in white or Coloured cement to match with the shades of tiles over 15 mm thick screed bedding layer in CM 1:4, complete all as per specified and as directed by Engineer-in-charge.
S & F 100 mm long excruded aluminium alloy anodised butt hinges with galvanised mild steel hinge pin type C-21, complete all as per specified and as directed by Engineer-in-charge.
Supply & laying GI pipe 15 mm bore medium grade fixed on wall/floor/trenches, complete all as specified and as directed by Engineer-in-charge.
S&F 15mm dia bore pillar tap cast copper alloy with capston heads chroumium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge.
S&F 75 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
M&L for erection of two staging walls with double stable of standard size of height upto 3m all as per SSR specifications and drawing NO RNG/ TD/ 37 sheet NO 1/1 for PVC tank complete all as per specified and as directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length, with rubber ring joints fixed to walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as per specified and as directed by Engineer-in-charge.
Removing excvated materials (soils) exceeding 250m but not exc. 500.00 m and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
M&L for rolled mild steel sections Fe 410-W (Gde-E- 250) quality - A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick Cement concrete type C1, 1:3:6 (using 20 mm graded stone aggregate) in footpath/ hard-standing / pavings / plinth protections, finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
Cutting into existing steel tubing for alterations or additions of 20mm dia bore of pipes (Each cut measured) complete all as per specified and as directed by Engineer-in-charge.
S&F 32 mm size waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly- nuts, flange end bedded in red lead cement and other end fixed complete all as per specified and as directed by Engineer-in-charge.
S&F 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore chromium plated bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as per specified and as directed by Engineer-in-charge.
S & F 15 mm bore stop cock, screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions, complete all as per specified and as directed by Engineer-in-charge.
S&F grating round 125 mm dia with waste hole of PTMT (minimum weight 40 grams), complete all as per specified and as directed by Engineer-in-charge.
S & F sink with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 bowl size 410 mm x 330 mm x 160 mm, complete all as per specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S Rajkamal Enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .