| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18.7 LAdmitted-Finance | -4.50% | ₹18.7 L | L1 | Admitted-Finance |
| 2 | L2₹19.4 LAdmitted-Finance | -1.00% | ₹19.4 L | L2 | Admitted-Finance |
| 3 | L3₹19.8 LAdmitted-Finance | +1.50% | ₹19.8 L | L3 | Admitted-Finance |
Tender Value
₹19.5 L
EMD Value
₹39,099
Closing Date
24 Feb 2026, 3:30 pmClosed
EXECUTIVE ENGINEER M/S
OFFICE OF THE EXECUTIVE ENGINEER M/S NDMC KIDWAI NAGAR WEST DELHI 110023
Repairing Servicing and Overhauling of 11KV VCBs Areva make installed at ESS LokNayak Bhawan and ESS National museum in Nirman Bhawan Zone
2026_NDMC_287023_1
24/EE(M/S)/2025-26
Open Tender
Electrical Works
45 days
NIRMAN BHAWAN ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹39,099
13 Mar 2026
16 Feb 2026
24 Feb 2026
16 Feb 2026
24 Feb 2026
16 Feb 2026
Rose Contact 630 Amp. Areva make (As per sample)
Bus-bar supporting insulator for Areva make (As per sample)
Spout Insulator with Metal Part R Phase Areva make VCB Bus-bar end, (As per sample).
Spout Insulator with Metal Part Y Phase Areva make VCB Bus-bar end, (As per sample)
Spout Insulator with Metal Part B Phase Areva make VCB Bus-bar end, (As per sample).
Spout Insulator with Metal Part R Phase Areva make VCB cable end, (As per sample)
Spout Insulator with Metal Part Y Phase Areva make VCB cable end, (As per sample)
Spout Insulator with Metal Part B Phase Areva make VCB cable end, (As per sample)
SITC of over current and earth fault relay, connections of CT wiring and auxiliary supply with modifications on HT panel as per requirement. (Make: Schneider/ABB/ Siemens) (As per Specified Technical Specification )
Tripping coil 30VDC , (As per sample)
Indication Lamp (As per sample)
Digital Ampere Meter (Schneider/ABB/Siemens/AE Make) suitable for 11 kV panels, as per sample
Digital Volt Meter (Schneider/ABB/Siemens/AE Make) suitable for 11 kV panels, as per sample
Cleaning of bus bars & coating with anti-oxidant, treatment on all the insulating parts/ metallic parts, tightening of all contacts in Bus Bar, Chambers, replacement of minor items/parts like nut & bolts etc. complete as required
Cleaning of CT’s chambers, PTs connections (PT Panels), replacement of PT fuses & tightening of all the contacts of 11KV cable end & coating with anti-oxidant treatment etc complete as required along with energization of P.T
Testing and Calibration of protective relay (O/C and E/F) with secondary injection set including tripping through relay closing of 11KV breaker and circuit breaker time setting test with CB timing test kit and performance should be as per IEEE C37.09, IEC 62271-100 standards. Also provide minor item like panel wiring, control wiring etc. complete job as required
ADD: GST @ 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.01 MB
BOQ_380208.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid