Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.9 L+₹2.4 L (5.46%)Rejected-Finance OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹46.0 L+₹2.5 L (5.69%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹46.2 L+₹2.7 L (6.11%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹46.8 L+₹3.3 L (7.60%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
25 Mar 2024, 6:00 pmClosed
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDN ALTN AND SPECIAL REPAIRS TO ELECTRICAL CABLES AND PIPE LINES FROM CG POWER HOUSE TO RETREAT OFFICERS ACCOMODATION AND SHIFTING OF STREET POLES CABLES PANELS AND PIPE LINE ALONG THE CGRHQ ROAD UNDER AOR OF GE HADDO PORT BLAIR
2024_MES_645222_1
8826/E8/A
Open Tender
Civil Works
Item Rate
180 days
PORT BLAIR
As per tender details
9 documents required · 9 mandatory
₹500
GE Haddo
₹87,400
Yes
7 Jun 2024
5 Mar 2024
28 Mar 2024
5 Mar 2024
25 Mar 2024
20 Mar 2024
6 Mar 2024 - 14 Mar 2024
Amount
Supply & fixed to wall, laid under floor and trenches, wall ceiling GI tubing medium grade ISI marked complete with all necessary fittings, accessories all as specified and directed of the following sizes :- Make :- Tata / Jindal / Surya
100 mm dia
80 mm dia
50 mm dia
S & F Gunmetal/brass gate valve, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like,flang, unions, check nuts, etc and any addition / alteration required for fixing, as fixed in repairs complete all as specified and as directed of the following sizes:- Make :- Leader / Zoloto / Sant // Quinn
50 mm dia
80 mm dia
Material,labour and laying of ductile iron pipe of size 100 dia flanged type (both end flanged) centrifugally cast (spun) including suitable specials class A, K-9, PN 16 in any length, laid in trenches/floors or on supporting pillar of size 100 dia as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour complete all as specified and as directed. Note : cost includes the suitable GI nuts and bolts. Make:- TATA/Electro steel/Jindal/Kirloskar/Rashmi/ Jai Balaji
M & L for Ductile iron pipe socket spigot centrifugally cast (spun) including suitable specials class A,K-9, in any length, laid in trenches/floors or on supporting pillar of size 150 mm dia as per IS-8239/2000 and with inside cement mortar lining and out side with blue in colour complete all as specified and as directed.Note : cost includes the suitable GI nuts and bolts. Make:-TATA/Electro steel/Jindal/Kirloskar/Rashmi/ Jai Balaji
Supply and fix sluice valve, class PN-1.6 flanged and drilled at both ends confirming to IS:14846 with ISI mak, having SS spindle, Brass check nuts and gun metal rings including wheel for operation all as specified including all joints with rubber gasket and jointing materials, bolts, nuts, washers etc with the following sizes complete all as specified and as directed. Note :- cost includes the suitable GI nuts and bolts. Make:- Leader/Kirloskar/Zoloto/Upadhyay/Venus
150 mm bore
100 mm bore
80 mm bore
Material and labour for construction of Brick Masonary valve chamber of size 1000x1000x1000 mm (internal dimensions) with PCC 1:4:8 foundation 100mm thick, brick work using PCC block masonary 200 thick wall built in CM 1:6,PCC 1:3:6 coping 50mm thick, plastering 15mm thick in CM 1:6 to all internal wall including floor,and exeternal wall upto 150mm below ground level, including excavtion earth work in hard/dense soil, MS sheet cover 4mm thick with locking arrangement with ISA 50x50x6 mm frame embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed
Taking down the existing pipe line of any size and any type of CG jetty fresh water line all as specified and as directed
Taking out old serviceable 100 mm dia Sluice valves care fully and refacing, regrinding and refixing the same at site as per requirement as directed by Engr-In-Charge. Note : fitting CI/DI specials measured and paid separately
Material and labour for Run lead joints (good quality) as per SSR Part-I suitable for 150 mm bore complete all as specified and as directed.
Material and labour for Run lead joints (good quality) as per SSR Part-I suitable for 100 mm bore complete all as specified and as directed.
Material and labour for rubber gasket (Tyton joints) for 150 mm bore DI pipe complete all as specified and as directed.
Material and labour for flanged joints (ISI Mark) including leather of minimum thickness 6mm and suitable size of MS nuts bolts and washers complete for 100 mm bore complete all as specified and as directed.
Taking up 100/150mm dia ductile iron pipe spigot and scoketed type from existing line and relaying the same at site as specified and as directed by Engr-In-Charge. Note : cost includes the suitable GI nuts and bolts.
Material and Labour for ductile iron fittings size upto 150 mm such as, bends,tapers,tee,pieces(single and double branch) any type/angle/radius and straight connecting pieces but all ends flanged/spigot and socketed type upto 400mm dia bore complete including nuts,bolts and washers complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation of poles, stays and struts and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for plain cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete including use and waste of from work complete all as specified and directed.
Material and labour for supporting pillar constructed of masonry of dimensions as required on site with precast cement concrete solid block masonry in PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) 20 mm thick in CM (1:6) complete all as specified and directed.
M & Labour for cutting the existing bitumen road at a width of 0.6 to 1 meter in width,1 to 1.3 meter in depth and after laying the water pipe the disturbed soil is should be return and refilling it and well ramming the surface and make the disturbed surface with PCC(1:2:4) type B1 mass concrete (using 20mm graded stone aggregate) complete all as specified and as directed
Supply and fixing 150 mm dia new CI Double out let Air Release Valve as per IS:14845 for fixing up in CI/DI water supply mains complete all as specified and as directed. Make :- Leader/Venus/BIR/Kirloskar/L&T/Upadhyay
Supply, laying, testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3½ core x 500 sq mm (laid in trenches, ducts, pole, wall etc.) complete all as specified and as as directed by engineer in charge.
Supply, laying, testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3½ core x 35sq.mm (laid in trenches, ducts, pole, wall etc.) including taking out old unserviceable LT cable from trenches/pole/ducts etc. complete all as specified and as as directed by engineer in charge.
All as per Item No.23 herein before but cable of size 4 core x 25sq.mm
All as per Item No.23 herein before but cable of size 4 core x 16sq.mm
All as per Item No.23 herein before but cable of size 2 core x 10 sq.mm
All as per Item No.23 herein before but cable of size 2 core x 6 sq.mm
Note: For Item Sr No 22 to 27 Excavation earth work will be measured and paid separately.
Dismantling existing PCC Pole/Steel tubular pole along with all light fittings & accessories of any type and height by disconnecting all electrical connections & light fittings including taking out old materials from the site and breaking of PCC foundation and refixing the same pole complete along with electrical connections along with same light fittings & accessories including making new PCC foundation and making connections as required including complete with cast iron base plate, finial taper plug, bolts, nuts & screws a at desired location at site all as specified and directed.
Dismantling existing garden lights/ path way lights including GI pipe & light fitting of any type and height by disconnecting the electrical connections & light fittings including taking out old materials from the site and breaking of PCC foundation and refixing the same garden lights/ path way lights complete along with electrical connections & same light fittings including making new PCC foundation and making connections as required and testing after making it fully serviceable by checking the condition and replacing the lamps only if required complete all as specified and as directed. NOTES : (i) Lamps, if required to be replaced shall be measured and paid separately as under relevant items as SUPPLY ONLY (ii) Necessary arrangements for carrying out dismantle and refix shall be under taken by the contractor.
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for mass filling of poles etc complete all as specified & directed.
M&L for cement concrete as in coping including necessary form work type B1 (1:2:4) using 20mm graded stone aggregate all as directed by Engr-in-Charge
Disconnecting old serviceable LT UG cables of size 2 core 6 sqmm to 4 core 16 sqmm and draw out from the pipe/pole or in under ground including re laying the same in trenches or in walls or poles with necessary clamping all as specified and as directed by Engineer-in-Charge. Note:Necessary excavation will be measured and paid seperately.
Disconnecting old serviceable LT UG cables of size 3.5 core 25 sqmm 50 sqmm and draw out from the pipe/pole or in under ground including re laying the same in trenches or in walls or poles with necessary clamping all as specified and as directed by Engineer-in-Charge. Note:Necessary excavation will be measured and paid seperately.
Disconnecting old serviceable LT UG cables of size 3.5 core 70 sqmm 120 sqmm and draw out from the pipe/pole or in under ground including re laying the same in trenches or in walls or poles with necessary clamping all as specified and as directed by Engineer-in-Charge. Note:Necessary excavation will be measured and paid seperately.
Taking out LT panel of any size by disconnecting all incoming and outgoing cables including breaking of PCC foundation for transporting and fixing in other place safely as directed including re-fixing of LT panel board with new PCC foundation, angle supports, nuts, bolts and washers including transportation like crane, truck etc without disturbing existing electrical system complete all as specified and as directed. Note: cost of necessary PCC, excavation and earth work is deemed to be included in Quoted rate.
Supply & fix FRP pole box 170 x 170 x 105 mm consisting of 1 No 50 A 4 pole connector and 1 No 16 A MCB SP including taking down the old/unserviceable junction boxes all as specified and directed.
Supply and fixing of LED street light fixture IP 66 with high power LED and unique power lens to ensure uniform light distribution, higher spacing between poles and maintenance free system of capacity 70 watts, 220 volts, 50Hz including removing of the old unserviceable halogen/any type of light fittings all as specified and directed.
M&L for street light mounting bracket made up of 32 mm dia galvanised steel tubing, medium grade, 1.50 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for steel tubular swaged poles 410 SP-31 (9.0 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable pole complete all as specified and directed.
Supply and fixing of out door type Street light timer Panel/Distribution Boards with 110A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 125A MCCB, Manual and Auto Mode Toggle switch cable connectors all as specified and directed.
Preparation of old painted surfaces RCC / steel tubular poles of street lights upto 10.0 metre height by scraping with emery paper and making free from rust, dust and any foreign material and applying one coat of synthetic enamel paint of tint as directed including letter writing such as pole number and source point of electric supply with black paint and fluorescent paint in circumference of poles /mast towers of various heights complete all as specified and as directed.
S&F cable jointing kits for joining LT cables for 4 core 16 to 25 sqmm / 3½ core x 25 to 120sqmm size cable complete all as specified and as as directed by engineer in charge.
Supply and fixing against repairs LED bulb, holder type, 7 watts capacity MAKE: PHILIPS WW/NW/CG/Havells/C&S
Supply and fixing against repairs LED bulb, holder type, 9 watts capacity. MAKE: WW/NW. PHILIPS/CG/Havells/C&S
Supply and fixing against repairs LED bulb, holder type, 12 watts capacity.MAKE: PHILIPS WW/NW./CG/Havells/C&S
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick,40mm bore medium grade (steel pipe) buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of the plate not less than 1.5m below normal GI, connected to galvanised earth strip 32 x 6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion. Note : Rate shall be deemed to be inclusive of necessary excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50 M RCC covers slab and PCC chamber etc.
Excavation in tranches n.exc 1.5 mtrs wide and not exv 1.5 M deep in soft/loose soil and getting out all as specified and directed.
Returning, filling in incl spreading, levelling and well ramming in layers not exc 25 cm in soft / loose soil all as specified and directed.
Removing excavated soil to a distance not exc 50M and depositing where directed at level not exc 1.5 m above starting point all as specified and directed.
Supply, install, testing and commissioning of factory made outdoor type sheet metal enclosure LT cable jointing box of minimum dimensions 90cm length x 75cm width x 70cm height size, CPRI approved of 3 way suitable for LT 1.1KV grade 3 phase 3 wire system with 09 Nos epoxy insulators with bus bar sizes for phase 40mmx20mm aluminium flat (03Nos) and neutral 40mmx10mm aluminium flat and bus bar support of epoxy type and made out of 3.15mm powder coated CRCA sheet having gasketed front hinged split doors with bottom detachable gland plate for upto 3 cable entry and exit of size 500 sqmm with suitable size of cadmium plated and nuts, bolts and wshers and incl weatherproof, bottom hole, outdoor triple key weather proof pad lockings. The panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided. The panel shall be of powder coated colour red complete all as specified and directed
Supply and laying HDPE DWC pipe of size 40mm (OD) x 32mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT cable protection complete all as specified and as directed by engineer in charge.
Supply and laying HDPE DWC pipe of size 50mm (OD) x 38mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed by engineer in charge.
Supply and laying HDPE DWC pipe of size 120 mm(OD) x 103mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed by engineer in charge.
CHANDER SEKER ENTERPRISE
Bismi Builders & Enterprises
SHUSHANT ASSOCIATES
M/s K Moorthi
LOOK UP ENTERPRISES
NAVJEEVAN ENTERPRISES
M/s Ramesh Lal
ICON AGENCIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .