Loading…
Loading…
Tender Value
₹2.5 Cr
EMD Value
₹1.5 L
Closing Date
23 Apr 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
CE(Baster)
CONSTRUCTION OF DIGITAL PLANETARIUM (CAT-III) BUILDING AT KARLI BLOCK-GEEDAM DISTT. DANTEWADA.
188295
NIT NO: 007/TC/2026-27
RESTRICTED TENDER
WORKS
7 days
CE(Baster)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Baster)
PWD Bastar Circle, Jagdalpur
Dakchhin Baster Div. dantewada
120
07
No
0
188295
23 Apr, 2026 5:00:00 PM IST
28 Apr, 2026 10:00:00 AM IST
2 Apr, 2026 5:00:00 PM IST
NIT NO: 007/TC/2026-27
CONSTRUCTION OF DIGITAL PLANETARIUM (CAT-III) BUILDING AT KARLI BLOCK-GEEDAM DISTT. DANTEWADA.
150000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
24528000.00
2
27 Apr, 2026 5:00:00 PM IST
24528000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 0h 24m
6 documents required · 5 mandatory · 1 optional
₹0
₹1.5 L
2 Apr 2026
2 Apr 2026
28 Apr 2026
2 Apr 2026
23 Apr 2026
2 Apr 2026
27 Apr 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Boring, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete M-35 grade, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto complete. (Length of pile for payment shall be measured upto bottom of pile cap): (15.3.2) 400 mm dia piles
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. (1.1.1) In all types of soils.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits (1.1.2) In ordinary rocks.
Extra for every additional lift of 1.5 m or part thereof. (1.6.1) All types of soils
Extra for every additional lift of 1.5 m or part thereof. (1.6.2) Ordinary or hard rocks
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc complete.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work (3.1.3) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work (3.1.4) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work (3.1.2) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. (3.3.2) M-25 Grade
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.1) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.2) Wall of any thickness including attached pilasters, buttresses etc. in superstructure.
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.7) Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Extra for additional height every 1m or part thereof where height of for form work exceeds 4.0 metre with adequate bracing, propping etc at allstaging levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.8) Beams, lintels, cantilevers & walls
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for (2.1.5) Columns, Pillars, Piers and likes- rectangular or square in shape
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.13) Weather shade, chhajja, Cornices and mouldings
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.3) Window sills, anchor blocks, string course, bends, copings, bed plates and like.
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.15) Stair cases of all types excluding spiral and folded plate type, including risers and landings
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.11) Arches, domes and likes, upto 6 M. Span.
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.12) Arches, domes and likes, exceeding 6 M. span Steel Reinforcements:
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: (3.12.1) Thermo-Mechanically treated bars FE 415
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Providing and fixing M.S. fan clamp/hook for ceiling fan made out of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop.
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. MASONRY WORKS.
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: (7.5.2) Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and laying AAC Autoclaved aerated concrete block confirming to IS: 2185 (Part-3)-1984) in block masonry with AAC blocks of width 100/ 200mm height 200/250/300mm, length 400/500/600 mm (approved sizes) with cement mortar 1 :6 (1 Cement :6 coarse sand) in superstructure. AACblocks should have specific gravity 0.6 to 0.65 and crushing strength should not be less than 3 N/ sqmm (testing as per IS: 6441 - 1972).
Half brick thick (9cm) brick masonry with modular well burnt clay bricks of crushing strength not less than 35 kg/sqcm and water absorption not more than 20% upto plinth level: (7.9.1) Cement Mortar 1:3 (1 cement : 3 coarse sand)
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry. PLASTER, PAINTING & FINISHING WORKS.
Providing and making 6mm thick cement plaster of mix: (11.1.1) In Cement mortar 1:3 (1 cement : 3 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: (11.3.3) In Cement Mortar 1:5 (1 cement : 5 fine sand)
Providing and making 20mm thick cement plaster on stone masonry of mix: (11.4.4) In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
Providing and making 18mm thick cement plaster in two coats with under layer of 12mm thick plaster 1:5 (1 cement : 5 fine sand) and top layer of 6mm thick with cement plaster 1:3 (1 cement : 3 fine sand) finished rough with sponge.
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.
Extra for plastering on circular work not exceeding 6.0 meters in radius.
Extra for plastering done on mouldings, cornices or architraves including neat finish to line and level.
Providing and making 18 mm thick moulded cement mortar band in two coats under layer of 12mm thick with cement mortar 1:5 (1 cement : 5 fine sand) and top layer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
White washing/ Colour washing with lime to give an evenshade in Three or more Coats for New surface as per relevant IS code 6278:1971 Consumption of lime 3.50kg /10 Sqm with all tools tackles and labour etc. complete for the work.
Providing and applying 2mm thick white cement based Acrylic grade putty with minimum 3 coats applied @ 4.0 kg/ l0Sqm as per relevant IS code 17545:2021 Acrylic grade putty with minimum 3 coats applied @ 4.0 kg/ l0Sqm as per relevant IS code 17545:2021(Product such as Asian trucare, _Berger Happy walls Putty , Birla Opus One pro smooth) to make the surface smooth and even with all tools tackles and labour etc. complete for the work . (This Item to be use in heigher grade painting works Item No. 14.65)
Providing and applying water proofing cement paint mimimum 2 coats applied @ 3.84 kg/10 sqm up to required finish as per relevant I.S. code 5410:2013 of required shade (product such as Snowcem plus, J.K. Shri Cement paints , century Cement Paints, Apex paints ,Maxcoat cement paint ) with all tool tackles and labour etc. complete for the work
Providing and applying satin/ matt finish Enamel paint minimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian satin Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Providing and applying Synthatic oil bound washable Distemper having VOC content less than 50gms/ lit. Minimum two coats up to final finish to give an even shade applied 1.25 kg/ I0Sqm as per relevant LS. Code 428:2000 (product such as Asian Tractor synthatic distemper , Berger Bison Lite , Dulux Magik , Birla Opus Style super smart) inclusive of providing abro tape on edges and article and cleaning of door, windows, flobr and surface as requiredwith all tools tackles and labour etc. complete for the work.
Providing and applying Luxury plastic emulsion paint with roller application mm1mum three coats applied @ 1.25 lit / 10Sqm up to final finish as per relevant Type - 1 Class D , C , B & A (Glossy /Semi Glossy and Matt , Egg Shell or Satin finish ) of required shade (Product such as Asian Royale Shyne,Dulux Velvet· Touch, Berger Silk Luxury Emulsion ,Nippon Impression Pearl , Opus Pure Elegance) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc, complete for the work. (with 4 Years Warranty)
Providing and applying FRENCH SPRIT POLISH on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if visible, applying a coat of wood filler, cleaning the surface, applying various (minimum 4 coats) of French spirit polish @0.35 lit/Sqm till the surface gives high gloss. inclusive of providing a.bro tape on edges and article and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work.
Providing and applying acrylic modified resin EXTERfOR TEXTURED with special quality silica quartz plaster as an intcnnediate coating on external surface giving rrotcctive layer and decorative finish on plastered surface in approved design and shade (product such as Asian Apex Series Duracast Dulux wcathershcald sandtax creation) as per m:rnufacturer's specifications inclusive of providing abro tape on edges and anicle and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc.complete for the work. (14.70.1) 2.0mm thickness (average) having design scratched with leveled & smooth surface.
Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final' finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex ,Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.) FLOORING & STONE WORKS.
Providing and Laying Matt/Glazed finish HOMOGENEOUS ACROSS FULL BODY VITRIFIED floor tiles (heavy duty) with water absorption less than 0.05% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. (12.78.1) Size 600x600mm thickness 9 to 10mm
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
Neat Cement punning.
Providing and Laying DOUBLE/ MULTI CHARGE (minimum 2.0mm thick layer) vitrified floor tiles with water absorption less than 0.05% and conforming to IS : 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. (12.79.1) Size 600x600mm thickness 9 to 10mm
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) (12.45.2) Granite stone black
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). (12.46.2) Granite stone black
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours shades over 20mm thick bed of cement Mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. (12.74.3) Size 600x600mm thickness 8 to 9mm
Providing and fixing rectified glazed ceramic wall/dado tiles of 1st quality conforming to IS : 15622-2017 of approved make, in all colours shades on wall and dados over 12mm thick bed of cement Mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm including pointing in white cement mixed with matching pigment complete. (12.75.2) Size 300x600mm thickness 7 to 8mm DOORS, WINDOWS, ROLLING SHUTTERS.
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring. (9.27.1) 80x1.25mm M.S. Laths
Providing and fixing M.S. sheet top cover for rolling shutter (9.29.1) 1.25mm thick
Providing and fixing 27.5cm long wire spring for rolling shutters.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. (9.57.2) SS Grade 304
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position (8.1.1) Teak wood
Providing and fixing antique/ SS finished brass butt hinges with antique/ SS polished MS screw complete: (8.77.1) 125x85x5.50mm (Heavy Type)
Providing and fixing factory made Pre-laminated particle board flat pressed three layer or graded wood particle board shutter (25 mm thick) with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all-round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws including fixing of stainless steel hinges 100x1.7mm etc complete as per direction of Engineer-in-Charge
Providing and fixing commercial grade water proof ply for wall paneling on wooden frame with necessary nails complete as required. (8.36.1) 19mm
Providing and fixing approved shade veneering on wood wall paneling complete as required
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. (8.18.1) 25 x 6 mm size
Extra for providing vision panel not exceeding 0.10 sqm in all type of flush shutters (excluding cost of glass) (8.19.1) Rectangular or square
Providing and fixing teak wood moulded beading to doors windows frames including necessary screws and primary coat on exposed surface. (8.39.4) 50x12mm
Providing and fixing stainless steel fixed stopper with necessary stainless steel screws complete. (8.144.1) 100 mm long
Providing and fixing IS: 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc complete.
Providing and fixing of six/seven levers branded and approved mortise lock.
Providing and fixing of floor spring IS: marked (Everite, Door link or any equivalent make) with stainless steel cover plate
Providing and fixing antique/ SS finished brass handles with antique/ SS polished MS screw complete: (8.84.1) 125 mm
Providing and fixing Acoustical Suspended ceiling System made of GRG Glass fiber reinforced gypsum tiles with Micro look edge and size 595x595x12mm as approved by Engineer-In-charge, in true Horizontal Level Suspended on inter locking metal grid of hot dipped galvanised steel section (galvanised @120 gsm/sqm, both side inclusive) consisting of main "T" Runner with suitably spaced joints to gen requird length and of size 15x32mm made from 0.30 thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 15x32mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T" at 600mm center to center from grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 15x32mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to from grids of 600x600 mm and wall angle of size 14x20 and laying false ceiling tiles of approved texture in the grid, cutting/making opening for services like diffusers, grills, light fitting, fixtures smoke detectors etc. wherever required. Main "T" runner to be suspended from ceiling using GI slotted cleats of size 27x37x25x1,6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm dia GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along main "T". bottom exposed width of 15mm of all "T" sections shall be pre-painted with polyester paint, all complete for all heights as per specification crawings of as directed by Engineer-In-Charge. The tiles should have Humidity resistance (RH) of 99% Light Reflectance >83%, Thermal Conductivity K=0..52-0.57w/mk, colour white, fire performance UK class 0/ class 1(BS 476 pt-6 and 7) in module size of 600x600x16 mm with Bio Block coating on th face of the tile, suibale of green building application with recyeled content of 38-41% Ceiling height up 3.5 mt from adjacent floor level extra height to be paid separately (10.66.2) With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) exturded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), uPVC extruded glazing beads of approrpriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy ( white powder coated ) casement handles, G.I fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screw etc. Profile of frame & sash shall be mired cut and fusion welded at all corners, mullion (if required ) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gab between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-charge. (Single/double glass panes and silicon sealant shall be paid separately vide chapter no. 9.51 ,9.58, 9.59 respectively) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimesion i.e in depth & width of profile shall be acceptable. (8.163A.2) Casement window single panels with S.S friction hinges (300 x 19 x 1.9 mm), made of (small series ) frame 47 x 50 mm, sash 47 x 68 mm & mullior. 47 x 68 mm all having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. ( Area of window above 0.75 spm upto 1.50 sqm)
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pipe, zinc alloy (white powder coated) touch lock with hook, zinc/alloy body with single nylon rollers (weight bearing capacity to be 40 kg.) G.I fasteners 100 x 8mm size for fixing frame to finished wall and neccessary stainless steel screws etc. Profile of frame & sash shall be mired cut and fusion welded at all corners, mullion (if required ) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gab between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-charge. (Single/double glass panes, wire mesh and silicon sealant shall be paid separately vide chapter no. 9.51 ,9.58, 9.59 respectively) (8.166D.2) Note: For uPVC frame & sash extruded profiles minus 5% tolerance in dimesion i.e in depth & width of profile shall be acceptable.
Providing and fixing Plain frosted glass film over glazed doors windows & partition etc. complete
Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete. MISCELLANEOUS ITEM OF WORKS.
Providing and fixing Suspended Ceiling system made of following tiles of specified thickness as approved by Engineer-In-charge, in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @ 120 gsm both side inclusive) consisting of main 'T' runner with suitably spaced at joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced 1200mm centre to centre and cross "T" of size 24x38 mm made of 0.30mm ( Minimum ) sheet, 1200 mm long spaced between main "T" at 600mm center to center form grid of 1200x600 mm and secondary cross "T" of length 600 mm and size size 24x38mm made from 0.30 mm thick (minimum) sheet, to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600mm and wall angle of size 24x24mm and laying false ceiling tiles of approved texture in the grid, cutting/making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc. wherever required. Main "T" runner to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm dia GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at 1200mm center to center along main "T" Bottom exposed width of 24mm of all "T" sections shall be pre-painted with polyester paint, all complete for all heights as per specification drawing or as directed by Engineer -In -charge. The tiles should have Humidity resistance (RH) OF 99% Light Reflectance> 83% Thermal conductivity K=0.052-0.57 w/mk,colour white, fire performance UK class 0/class 1(BS476Vpt-6 and 7) in module size of 600x600x16 mm with bio Block coating of the face of the tiles suitable for green building application. with recycled content of of 38-41% ceiling height up 3.5 mt. from adjacent floor level extra height to be paid separately (10.68.1) With Perforated Vinyl laminated gypsum panels of size 595x595x9mm thick, having 3x3mm square perforations @ 8.33mm pitch-10.2% open area tapered edge having density 800 Kgs/cum, weight 7.2 Kg/sqm, NRC upto 0.75
Providing and fixing of aluminium panel false ceiling of approved colour consisting of panels 300mm wide x 30 mm deep x 0.7mm thick with bevel edge and length up to 6.0 metre. The panels are made from corrosion resistance aluminium alloy AA 3005 (Al. Mg) (for higher strength and good roll forming characteristics) sheet chromatised for maximum bond between metal and paint, enamel painted twice under high temperature, one side with a full primer and finish coat and the other side (inner side) with a primer coating and Skin Coat on a Continuous Paint Line. Panel shall be fixed by clipping to panel carrier of size 41.5mm wide x 62mm deep x 0.95mm thick in standard length of upto 5 metre made of doubled baked black enamelled aluminium alloy AA 5050 (Al. Mg) with cut outs to hold the 300mm wide panels fixed at a distance of 0.3 m from wall and 2.4 m from centre to center. Panel carrier shall be suspended by means of G.I. suspension rod 4mm dia and a Galvanised suspension spring clip at a distance of 1.7 m centre to center. Wall trim box of size 15x30x15mm made from 0.4mm thick aluminium alloy sheet to be provided all along the wall to hold panels (only surface area of false ceiling is to be measured and no deductions for lights, diffusers, columns etc shall be made) (10.64.2) With long perforated panels having perforation with 2.0mm dia and 5mm center to center and pasted with non woven tissue on the back side.
Providing Water proofing treatment over Roof, Wall, Chhajjas, Balcony with Diamond Shield and Sealer coat or equivalent at leakage/ seepage area consisting of the operation: (i) Surface preparation roughening of surface, opening of cracks in 'V' groove in size of 5mm x 10m (WxD), filling of cracks with putty of Diamond shield with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/ Nylon brush. Removing all dust particles and washing with adequate water to clean completely (ii) Providing and applying 1st coat of diamond shield or equivalent compound (having two component dry powder 80% Chemical 20% (chemical having 30% solid contents) making flexible waterproof and protective modified mortar with minimum thickness 70-80 micron after proper mixing of both the parts of compound along with laying of fiber glass mesh (of weaving size of 10x10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd coat with minimum thickness 100 micron of the same compound. Allow the 2 coat to set in natural air for minimum 4 Hrs. Total consumption of the diamond shield or equivalent in both coat should be @ 17.90 kg for 10sqm area. iii) Over the above layers providing and applying 1st coat of sealer compound (Single component High Build elastomeric, flexible, pure acrylic waterproofing membranes having solid content of 65%) minimum 50-60 micron and allow it to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd and final coat 120-140 micron of sealer compound and allow it to set in natural air for minimum 4 Hrs. Consumption of Sealer compound should be @ 5.40 kg per 10 sqm area. The final area appearance of the coating will be milky white (iv) The treated area should be cure with water for 48 hrs by flooding the surface. All above operations to be done in order
Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same :
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
Grading roof for water proofing treatment with: (4.13.1) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : (12.37.1) Light shade using white cement
Providing post water proofing treatment against dampness & Seepage in roof, terraces, sunken floor of toilets with reinforced acrylic breathable (polymer content 35%, elongation at break at > 100%) coating consisting of following operations: i) Removing loose material and cleaning the surface. ii) Priming in one coat with water based acrylic emulsion. iii) Three coats with reinforced acrylic breathable polymer.
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) (1.25.1) Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) (1.25.2) Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) (1.25.3) Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Diluting chemical emulsion (chlorpyrifos/ lindane) in oil or kerosene based solution as per manufacturers recommendation and injecting the diluted chemical emulsion for post - constructional anti-termite treatment of wood work at points of contact @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Diluting chemical emulsion (chlorpyrifos/ lindane) in oil or kerosene based solution as per manufacturers recommendation and injecting the diluted chemical emulsion for post - constructional anti-termite treatment of wood work at points of contact @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smooth.
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (19.5.2) 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (19.5.3) 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (19.5.4) 32 mm nominal outer dia .Pipes. Section - B, Sanitary, Plumbing & Draiange Installation works:
Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with ISI marked white plastic seat and lid, 10 litre PVC low level flushing cistern with fitting and brackets, 40mm flush bend, mosquito proof coupling complete, including painting of brackets, cutting and making good the walls and floors wherever required (18.5.1) White:
Providing and fixing vitreous china pedestal type water closet (European type) with inbuilt 10 litre low level vitreous china flushing cistern, ISI marked plastic seat and lid (same colour), mosquito proof coupling complete: (18.12.1) White
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: (19.14.19) Health foscet (hand jet) with flexible connection pipe (for WC)
CP brass water jet to be fixed in seat cover of WC with flexible connection pipe
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: (18.13.1) Flat back half stall urinal of size 460x380x250mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : (18.17.1) White Size 550x450 mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : (18.17.5) White Oval or round size 550x400mm.
Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: (18.10.2) 45 CM length
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: (19.14.6) Stop cock (concealed) (600 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: (19.14.7) Angle valve for basin mixer and geyser points (450 grams)
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600x120x5mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (18.30.1) 5mm thick mirror
Toilet paper holder
Towel rail (600mm long x 20mm dia)
Soap dish plate
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., (19.5.1) 15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., (19.5.2) 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., (19.5.3) 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., (19.5.4) 32 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK (19.6.4) 32 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK (19.6.5) 40 mm nominal outer dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK (19.6.6) 50 mm nominal outer dia pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (19.17.1) 15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (19.17.2) 20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (19.17.3) 25 mm nominal bore
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): (19.16.3) 40 mm nominal bore
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): (19.16.4) 50 mm nominal bore Drainage & Sewerage
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. (18.76.1) 75 mm dia pipe.
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. (18.76.2) 110 mm dia pipe.
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. (18.76.3) 150 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (18.77.1) Tee/ Tee with door/ Bend 45°/ Bend 90° (18.77.1.1) 75 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (18.77.1.2) 110 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (18.77.1.3) 150 mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (18.78.1) 75 mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (18.78.2) 110 mm
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : (20.7.1) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Providing and constructing brick masonry road gully chamber 50x45x60 cm with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard design.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. (1.1.1) In all types of soils.
Extra for every additional lift of 1.5 m or part thereof. (1.6.1) All types of soils
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work. (3.1.3) 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (3.2.1) 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:Cement Mortar 1:5 (1 cement : 5 coarse sand)
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: (3.12.2) Thermo-Mechanically treated bars FE 500D
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: (2.1.7) Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Providing and making 12mm thick cement plaster of mix: (11.2.1) In cement Mortar 1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.
Neat Cement punning.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. (9.6.2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Supplying,assembling,lowering and fixing in vertical position in bore well ISI marked G.I. Casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS:1239 (Part-1& Part-2)1992 with Ivth revision (Up-to-date amendments) of reputed & approved make including required hire & labour charges fittings & accessories all complete for all depths as per direction of Engineer-in-charge. (21.5.3) 150 mm nominal dia
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (part 1) including collecting samples from different strata preparing and submitting strata chart/bore log including hire & running charges of all eqipments tools plants & machineries required for the job all complete as per direction of Engineer-in-charge upto 90 metre depth below ground level. All types of soil. 150 mm dia
Rocky strata with boulder 150 mm dia
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS:2800 (part 1) including collecting samples from different strata preparing and submitting strata chart/bore log including hire & running charges of all eqipments tools plants & machineries required for the job all complete as per direction of Engineer-in-charge beyond 90 metre & upto 150 metre depth below ground level. Rocky strata includings boulder 150 mm dia
Providing and fixing suitable size threaded mild steel l cap or spot welded plate to the top of bore well housing/casing pipe removal as per requirement all complete for bore well of: (21.11.3) 150mm dia
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: (19.7.5) 40 mm dia. nominal bore Section - C, Fire Detection & Fire Fighting works:
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. (23.1.2) 65mm dia.
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. (23.1.3) 80mm dia.
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. (23.1.4) 100mm dia.
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. (23.1.5) 150mm dia.
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. (23.2.2) 65mm dia.
(Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 23.2.3) 80mm dia.
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. (23.2.4) 100mm dia.
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. (23.2.5) 150mm dia.
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. (23.4.2) 100mm dia
Supplying, fixing, testing and commissioning of flanged butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS: 13095 of following sizes as required. (23.5.2) 100mm dia
Providing and fixing C.I. double flanged sluice valves rated to PN 1.6 with C.I. Wheel bolts, nuts, washers 3mm thick insertion rubber gasket including matching flanges table E, complete. (23.6.1) 100mm dia
Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia and with necessary G.I. coupling, valve to be fitted on top of Air vessel or on wet riser as per specification.
Providing and fixing Flow switches suitable for fixing in 50mm to 150mm dia pipe line, complete with all accessories to provide indication in annunciator panel.
Providing and fixing pressure switch with suitable for 1-10 Kg/cm2 including 12/15 mm Ø isolation valve, G.I. nipple, elbow, electrical connections setting of Cut-In and cut-Off pressure complete in all respects and in an approved manner
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner.
Providing and fixing 15 mm dia, Quartzoid bulb type G.M. Sprinkler Head set to operate at 680C of approved make chrome plated complete in all respect as required.
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. (9.1.5) 3 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 25KA
Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. (10.9.4) 400 amps
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). (15.1.13) 3.5 x 50 sq. mm.
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification and IS: 694 (2010). Note: submersible Cable should be rust proof, safe from oil / Grease and under water Chemical / abrasion Resistant. (23.3.4) 3.0 HP, three phase
Suppying , installation , testing and commissioning of Fire alarm Control panel (UL Listed) suitable for 50 addressable points (Detector & Devices). Comprising of the following system components: Operating units, Periphery boards, Power supplies,System enclosures, with battery backup 24hours and 30minutes,
UOM Code
1000 piece
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7193847464162118741_188295_Form A.doc
NIT • 0.18 MB
7810482238914859187_188295_NIT.doc
NIT • 0.31 MB
4798150189136350746_188295_LIST OF APPROVED of all.pdf
NIT • 0.13 MB
7815456237824267849_188295_ANNEXURE-E NEW.doc
NIT • 0.03 MB
4028679285460637370_188295_Notice planatorium.docx
NIT • 0.04 MB
7581604488437809440_188295_BOQ.xlsx
BOQ • 0.08 MB
Download all tender documents and submit your bid