| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.2 LAdmitted-Finance | -0.11% | ₹10.2 L | L1 | Admitted-Finance |
| 2 | L2₹10.2 LAdmitted-Finance 75 1 A B T ROAD KOLKATA 700002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | +0.00% | ₹10.2 L | L2 | Admitted-Finance |
| 3 | L3₹10.3 LAdmitted-Finance GANESH NAGAR BARUIPARA HARIHAR PARA MURSHIDABAD WB 742165 | HARIHAR PARA | MURSHIDABAD | WEST BENGAL | 742165 | +1.00% | ₹10.3 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical 81 7A RAJA S C MALLICK ROAD KOLKATA 700047 | KOLKATA | KOLKATA | WEST BENGAL | 700047 | - | - | - | Rejected-Technical Required document not submitted as per NIT |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical Required document not submitted as per NIT |
Tender Value
₹10.2 L
EMD Value
₹20,405
Closing Date
9 Feb 2026, 11:30 amClosed
Sri. Sukdeb Halder Executive Enginer KCD PWD
45 Ganesh Chandra Avenue Kolkata 13
Emergent restoration of the Godown of West Bengal State Book Board within the premises of The Sanskrit College and University, 1 Bankim Chatterjee Street, Kolkata - 700073 during the year 2025-2026.
2026_WBPWD_991636_1
WBPWD/EE/KCD/NIeT24/2025-26
Open Tender
CIVIL WORKS
45 days
45 Ganesh Chandra Avenue
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,405
Yes
12 Mar 2026
20 Jan 2026
11 Feb 2026
23 Jan 2026
9 Feb 2026
23 Jan 2026
Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed.
Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed.
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m
Welding in M.S. structural work with gas or electric: (a) Tack weld
b) Continuous weld
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping)B) 450 mm lapping each way (a) With 0.60 mm sheet
Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping)
Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor)(ii) In wall:-b) With 0.63 mm thick sheet
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
(A) Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.)(ii) Sal : Local.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Mazdoor (Male)
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
Renewing X.P.M. including taking out and refixing with new battens made of local wood of size 50mmx25mm and new screws etc. complete. (a) 25mm x 75mm strand 3.25mm x 1.6mm.
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 20 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (iii) 160 mm. Dia.
d) shoe iii) 160mm dia
Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). (a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr
(b) Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr.
Supply fitting and fixing ISI marked CO2 type fire extinguisher 4.5 kg capacity conforming to IS : 15683 : 2006 made from seamless cylinder conforming to IS : 7285 duly approved by the Chief Controller of Explosive, Nagpur, fitted with ISI marked controlled value conforming to IS : 3224 high pressure 1 metre long discharge hose and horn complete with initial gas charged with carrying handle wall mounting bracket, suitable for operating between +30 C to 55 C, Fire rating Class - 34B complete in all respect including all taxes and in all floors.
stage.html
html • 0.13 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_2424510.xls
BOQ • 0.27 MB
2911.pdf
Tender Documents • 1.86 MB
Download all tender documents and submit your bid