Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹1.6 L (7.05%)Rejected-Finance | L2 | Rejected-Finance Other then L1 | |
| 3 | L3₹27.1 L+₹4.5 L (19.7%)Rejected-Finance BYE PASS DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other then L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SATWARI
GE SATWARI PIN 180003
REPAIR MAINT OF SUMMER COOLING AND HEATING APPLIANCE UNDER AGE EM OF GE SATWARI
2024_MES_666896_1
GEJM-41/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
Yes
GE SATWARI
₹60,000
Yes
28 Oct 2024
19 Jul 2024
14 Sept 2024
20 Jul 2024
12 Sept 2024
3 Aug 2024
20 Jul 2024 - 3 Aug 2024
Amount
Attending of day to day complaints 7x24 Hrs for summer and cooling appliances system all type nature of complaints for ACs, Refrigerator/Water cooler/Desert cooler and Geyser etc and any types / nature of complains at OTM, KLP & Md accn of Defence Colony, 'Y' Station and Ridge, Raulki Area as directed by MES rep of GE Satwari. NOTE: (i) Contractor/his representative shall attend MES service centre daily rutine complains at 0900 hrs to note down the complaints from concern JE and shall submit complaince report at 1700hrs for the complaints given in the morning. (ii) Labour rates deemed to be included in the quoted rate in r/o relevant sch of items.
(iii) All type of T&P as requried at site for the work shall be arranged by the contractor under his own arrangements, cost deem to be included in quoted rates. (iv) A recovery @ of Rs. 950/- per day per complaint shall be recovered from the contractor if complaint given to the contrctor remains unattended/not rectified at the end of the day. (v) Contractor shall employee minium of one Refrigeration Mechanic and one helper or relevant technician (for complaints) having adequated expreience in the said field. (vI) Any type of complaints to be attend and record in complain slip.
Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditioner / window type AC and Inverter type Split AC of capacity 2.0 TR by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge. Note :- Spares parts replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per ser item No 03 above here-in-before Split Type AC of capacity 1.5 TR
All as per ser item No 03 above here-in-before Window type AC 2.0 TR Capacity
All as per ser item No 03 above here-in-before Window type AC 1.5 TR Capacity
Material and labour for servicing / cleaning of complete water cooler of any size and capacity by cleaning the outer unit by means adding cleaning solution with water. The cleaning of condensor and chiller tubes is done with use of nylon brushes till the scaling is removed for water cooler & deep freezer the inner tank should be cleaned using bleaching powder and keeping the inner tank clean from bacterial and descaling and ensuring its serviceability all as specified and as directed by Engineer-in-Charge. Note :- Spares parts replacement will be measured and paid separately under relevant item of Sch 'A'.
All as per ser item No 07 above here-in-before Refrigerator of any capacity, make and model
All as per ser item No 07 above here-in-before Deep freezer of any capacity, make and model
Taking out unserviceable Receprocating type compressor of window type AC 1.5/2.0 ton capacity, from site and replacement of new compressor against repair of existing make (R Compressor) and re-fixing the compressor sealed unit in position, charging of refrigerant gas R-22 /R-32/R410a any type as required at site of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-in-charge
All as per item 10 above but for Split Type AC 1.5 Ton capacity
All as per item 10 above but for Split Type AC 2 Ton capacity
Taking out unserviceable Rotary type compressor of window type AC 1.5 /2.0 ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete as directed by the Engineer-in-charge.
All as per item 13 above but for Split Type AC 1.5 Ton capacity
All as per item 13 above but for Split Type AC 2 Ton capacity
Taking down unserviceable Split/Window AC 1.5 /2TR compressor any make and model, transporting to workshop, reconditioning by cutting, removing burnt winding including insulation and rewinding with suitable size super enameled copper wire of same gauge and size, over hauling of compressor including replacement of worn-out spares, compressor oil etc, re-assembling, welding, pressure testing, refixing, leakage testing and gas charging and refixing at the same location to the unit all as directed by Engr-in-charge.
All as per item 16 above but for Water cooler of any make and capacity
All as per item 16 above but for Refrigerator of any make and capacity
All as per item 16 above but for Deep freezer of any make and capacity.
Pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers and capillary tubes all as required testing complete for Air conditioner window type/Split type and Split AC Inverter technology of capacity 1.5 / 2 TR capacity including transportation to workshop complete all as specified and directed by Engineer-in-charge. Note:- Charging of gas any type will be measured and paid separatly.
All as per item 20 above but for Water cooler of any make and capacity
All as per item 20 above but for Refrigerator of any make and capacity
All as per item 20 above but for Deep Freezer of any make and capacity
M & L of Gas charging with R-134a/410/22A for Refrigerator and Water coolers in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also) complete all as specified and directed.
M & L of Gas charging with R-32 for split / windows AC in position including leak testing to achieve desired suction pressure and temperature (or any other cooling applainces also) complete all as specified and directed.
Supply & fixing in replacement of Condenser blower motor for Outdoor Split /Window type type AC 1.5/2 TR capacity as per existing type.
Supply & fixing in replacement of Condenser blower motor of water cooler / deep freezer/ Refgrigerator of any capacity, make and model as per existing type
Supply & fixing in replacement of Blower motor of indoor unit of split AC 1.5/2TR as per existing type
Supply & fixing in replacement of Fan Blade suitable for 1.5 / 2 Ton Split / Window Type Air conditioner as per existing type
Supply & fixing in replacement of Fan Blade suitable for Water Cooler of any capacity / Make as per existing type
Dismantling /taking down carefully of Water cooler of any capacity and make preparing the old faded surface / tinkering and applying two coats of suitable metallic paint of original colour over a coat of red oxide primer including writing MES NO./SM NO.complete all as specified and directed.
All as per item No 31 above here-in-before of Refrigeratror any size and capacity.
All as per item No 31 above here-in-before o Deepfreezer of any capacity and make
Supply & fixing in replacement of thermostat for water cooler / refrigerator / deep freezer / Window type ACs of any capacity and make.
Supply & fixing in replacement of relay for any type of AC / water cooler /refrigerator/deep freezer of any capacity & make as per existing type.
Supply & fixing in replacement of OLP for any type of A/C/water cooler /refrigerator/deep freezer of any capacity & make as per existing type.
Supply& fixing in replacement of new PCB suitable for split type A/C 2/1.5 TR of any make as per existing type.
Supply & fixing in replacement of new PCB card for complete burnt or unserviceable PCB card of inverter technology split AC 1.5/2.0 TR of any make & type .
Repairing of defective PCB card indoor/out door for unserviceable PCB card of inverter technology split AC 1.5/2.0 TR of any make & type as per existing type .
Repairing defective PCB window/split type AC 1.5/2.0 Ton any type and refixing after repair.
Supply & fixing in replacement of wiring kit suitable for split type A/C 2/1.5 TR of any make as per existing type.
Supply & fixing in replacement of wiring kit suitable for water cooler/refrigerator/deepfreezer /Window type ACs of any capacity and make as per existing type.
Supply & fixing in replacement of starting capacitor 80/ 100 mfd for airconditioner as per existing type.
Supply & fixing in replacement of starting capacitor 120 mfd for airconditioner as per existing type .
Supply & fixing in replacement of Running capacitor 45 mfd for Air condition Window / Split AC 1.5 Ton Capacity as per existing type.
Supply & fixing in replacement of Running Capacitor capacitor 60 mfd for Air conditioner 2 Ton Capacity as per existing type.
Supply & fixing in replacement of Running capacitor 36 mfd for air conditioner of any capacity & water cooler of any capacity as per existing type
Supply & fixing in replacement of auto swing motor for inside unit of split A/C of capacity 2/1.5 TR of any make as per existing type
Supply & fixing in replacement of PCB suitable for remote control system of split / window type A/C of capacity 2/1.5 TR as per existing type .
Supply & fixing in replacement of PVC air filter for split /window type A/C of any capacity & make as per existing type.
Supply & fixing in replacement of contactor suitable for 2/1.5 TR of any make as per existing type
Supply & fixing in replacement of front Grill suitable for 1.5/2.0 TR window AC as per existing Make/Model complete as per existing type.
Supply & fixing in replacement of new display unit for complete burnt/unserviceable display of AC any type and make/model as per existing type.
Supply & fixing in replacement of reversible valve in window/split AC 1.5/2.0TR including making bypass system with copper tubes/brazing works etc. complete as per existing type.
Supply & fixing in replacement of outdoor type unit split Air conditioner electric driven single phase 220 volts of cap 1.5 TR Hot & Cold type complete with all accessories as per existing make and model.
Supply & fixing in replacement of motor three speed single phase , double shaft suitable for window type AC 1.5/2 ton capacity of existing rating/make & type.
Supply & fixing in replacement of motor single speed, single phase suitable for condensing unit ( outer unit ) of split type AC 1.5/2 ton of existing rating/make & type.
Supply & fixing in replacement of motor three speed single phase suitable for cooling unit (inner unit) of split type AC 1.5/2 ton of existing rating/make & type.
Supply & fixing in replacement of Brass angle valve 5/8 inch for split AC 1.5/2TR capacity as per existing type.
Supply & fixing in replacement of Brass angle valve 3/8 inch for split AC 1.5/2TR capacity as per existing type.
Supply & fixing in replacement of Copper tubing 5/8" dia for extending refrigerant piping including brazing/adopter and accessories.
Supply & fixing in replacement of Copper tubing 3/8" dia for extending refrigerant piping including brazing/adopter and accessories as per existing type.
Supply & fixing in replacement of Puff insulation to suction pipe of split AC.
Supply & fixing in replacement of Door lock for refrigerator /Deep freezers any capacity as per existing type
Supply & fixing in replacement of Baffle tray for refrigerator any type as per existing type as per existing type
Supply & fixing in replacement of Crisper tray for refrigerator any type as per existing type
Supply & fixing in replacement of Bi-metal for refrigerator as per existing make and model.
Supply & fixing in replacement of de-frost timer for refrigerator as per existing make /model.
Supply & fixing in replacement of PVC ball valves, float valve for water cooler of any capacity & make as per existing type.
Supply & fixing in replacement of brass chromium plated push button tap outer/Inner thread suitable for water cooler of any type of size 15 mm as per existing type.
Supply & fixing in replacement of drain pipe as per existing size suitable for water cooler.
Supply & fixing in replacement of PCB suitable for capacity upto 5 KVA Voltage stabiliser as per existing type.
Supply& fixing in replacement of Transformer Suitable capacity for 4 KVA to 5 KVA Voltage stabiliser as per existing type.
M&L for plug top 15 Amp, 3 pin conforming to IS. Make - Anchor/Crompton/Legrand/Havells.
M&L for plug top 5 Amp, 3 Pin conforming to IS.
Supply & fixing in replacement of indoor type unit split Air conditioner electric driven single phase 220 volts of cap 1.5 TR Hot & Cold type complete with all accessories as per existing make and model.
S&F in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN 20 Amps, 240 Volts, AC, 50 HZ, completete all as specified and directed, including taking down old unserviceable plug socket and offering for credit.
Supply and fixing MS clamps, bracket, supports, bolts, nuts & washers for stand/supporting Window/split AC & desert cooler including necessary fixing on wall and making good to match with surrounding as per existing complete all as specified and directed.
Taking down existing window / split type AC of any make / capacity after disconnecting all connects and Refixing in same / another location including fixing arrangement, after carrying out necessary maintenance / servicing including testing on load at site complete all as specified and directed by Engineer - in- charge.
Supply & fixing in replacement of Fan Motor with blade heavy duty for desert cooler 220/240Volts, 50 HZ, single phase 180Watt and testing complete all as specified and directed. Make Crompton greaves/Havells/Bajaj.
Supply & fixing in replacement of submersible pump 50 Watts for desert cooler operational on 230 Volts AC, 50 HZ complete all as specified. Make - Crompton Greaves/Khaitan/Bajaj.
Supply & fixing in replacement of desert cooler steel body of size 26x26x34 and tank height 7" made out out of heavy gauge galvanised iron sheets and fitted with heavy duty 3 speed 18" exhaust fan and pump complete all as specified and directed. Make of exhaust fan and pump Crompton/ Havells/Usha/Khaitan.
Supply & fixing in replacement of Capacitor 3.15 to 4 MFD complete all as specified. Make- Usha/tesla/Asian/suncap.
Supply & fixing in replacement of indication lamp 230 volts 50 HZ suitable forexisting desert cooler complete.
Supply & fixing in replacement of PVC water connection pipe incl PVC elbow & Stop cock as per existing size complete.
Supply & fixing in replacement of floot valve with rod complete set of desert cooler as per existing size & make complete.
Supply & fixing in replacement of thick wood wool pads suitable for desert cooler as per existing size/type all as specified.
Supply & fixing in replacement of PVC water distribution pipe incl PVC elbow /Tee for distributor suitable for desert cooler as per existing size/type complete all as specified and directed by Engineer -in-charge.
Supply & fixing in replacement of aluminium plate for mounting controls switch and regulator etc suitable for desert cooler as per existing size/type all as specified and directed.
Material and labour for applying synthetic enamel paint with Two coat of spray painting of approved colour to the body of desert cooler of inner & outer side and writing MES No etc with marking as per instruction complete including prepration of old painted surface complete all as specified.
Taking down & Re-Fixing in same / other location of Geyser capacity 25 / 50 Ltr any type, make and mounting on Wall including provision of 4 Nos of anchor bolts of suitable size, PVC connection for inlet and cromium plated copper connection for outlet (HOT WATER SIDE) connection making the electric connections, testing and commissionning complete all as directed by Engineer in charge.
Material & Labour for servicing, cleaning with castic soda solution including trouble shooting /repair rectifying leakage by braising assembly of geyser 25 Ltrs to 50Ltrs capacity checking of serviceability of individual parts such as thermostat, heating element, pressure release valve, inlet/outlet connections etc, replacing worn-out nut bolt, washers, fasteners and defective components and testing including taking down the geysers and refixing the same after repairs complete all as specified. Note : U/S replacement spare parts will be measured and paid separately under relevant item. Rate quoted shall include replacement of worn-out fasteners.
Supply & fixing in replacement of copper heater coil of geyser cap 1.5 KW any type i.e Circular, spring single/double rounded, tringle single/double all as per existing make / model / size conforming to relevant IS. Make - Eterno/Crompton/Havells/Airex/Swastik.
All as per ser item No 95 above of cap 2 KW any type
Supply & fixing in replacement of copper heater coil of geyser cap 1.5 /2.0 KW any type i.e in built of thermostate Circular, spring single/double rounded, tringle single/double all as per existing make / model / size conforming to relevant IS. Make - Eterno/Crompton/Havells/Airex/Swastik.
Supply & fixing in replacement of thermostat for any type /make/capacity of geyser .
Supply & fixing in replacement of copper assembly of size not less than 15mm bore (water inlet & outlet) of cap 50 Ltrs complete of any type /make of geyser complete all as specified and directed.
All as per ser item No 99 above of cap 25 Ltrs any type
Supply & fixing in replacement of Glasslined double ceramic Element 2 KW (Two year Guarantee) all as per existing make / model / size conforming to relevant IS.
Supply & fixing in replacement of drain plug suitable for 25/50 litre capacity storage type water heater including rubber washer etc.
Supply & fixing in replacement of pressure release valve 15mm dia with new one for any type /make/capacity of geyser complate.
Supply & fixing in replacement of heavy duty PVC flexible steel wire laminated 450mm connection pipe of 15mm dia with check nuts with new one suitable for cold/hot water connection of geysers complete all as specified.
Supply & fixing in replacement of heavy duty PVC flexible steel wire laminated 600mm connection pipe of 15mm dia with check nuts with new one suitable for cold/hot water connection of geysers complete all as specified.
S&F in replacement copper cable flexible 3 core of size 4 sq mm .PVC insulated complete all as specified.
Supply & fixing in replacement of metal Plug Top industrial type of size 15 Amps complete all as specified.
Supply & fixing in replacement of anchor bolt/fastner of size 4" for fixing of Geyser any type complete all as specified.
M&L in replacement GI tubing 15mm dia medium grade in short length with all fittings complete to walls, or laid on roofs including taking down existing unserviceable pipes.
S&F in replacement stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends with iron pipes of 15mm bore including taking down existing unserviceable stop valves.
Supply and Fix in replacement 20 mm Non return valves, cast copper alloy, for GI Pipes pipe all as directed.
M & L for cleaning the surface of geysers 25 / 50 Ltrs capacity to free from dust, grease and preparing surfaces for painting and spray painting with synthetic enamel paint of existing colour including writing MES No. complete all as specified and directed.
Taking down the copper or steel container carefully from the geyser, descaling, rectifying leakage by braising, resetting the insulating (glass wool), testing for the required pressure replacing rubber gaskets, worn-out fasteners etc, with new ones complete all as directed by Engineer in charge.
S&F in replacement MCB Single pole, 240 volts 5 to 30 Amps 10 KA rupturing capacity for Acs and Geysers of various ratings.
Supply and Fix in replacement Base plate of Water Heater of 25 / 50 Ltrs Capacity all as directed.
Supply & fixing in replacement of in replacement Indicator Lamp of RED / GREEN Suitable for Water Heater
Supply & fixing in replacement of water storage inner tank of steel body porcelain enameled glass lined tank (five year guarantee) Pressure minimum 8 bar of capacity 25 Ltrs inc 15mm dai galvanised air release valve as per existing size and model complete all as specified. Make- Venus/Recold/Havells/Bajaj/AO-smith.
Supply & fixing in replacement of water storage inner tank of steel body porcelain enameled glass lined tank (five year guarantee) pressure minimum 8 bar of capacity 50 Ltrs inc 15mm dai galvanised air release valve as per existing make and model complete all as specified. Make- Venus/Recold/Havells/Bajaj/AO-smith.
Supply & fixing in replacement of water storage inner tank of steel body of capacity 25 Ltrs inc 15mm dai galvanised air release valve as per existing make and model complete.
Supply & fixing in replacement of water storage inner tank of steel body of capacity 50 Ltrs inc 15mm dai galvanised air release valve as per existing make and model complete.
Supply and fixing in replacement of thermal cut out Bi-metallic disc type with snap action switch, with operator below the boiling point i.e 90º+ 6ºC with manual reset-knob for Geyser. Make Alcon/Shemaro.
Supply & fixing in replacement of Glass wool suitable for water staorage Geyser of any cap complete all as specified.
M & L in replacement of sub main wiring with single core copper cable 2x4 sqmm FRLS insulated unsheathed starndard copper conductor cable 1100 volts grade in rigit PVC conduit (Concealed) medium grade alongwith 1x4 sqmm as earth wire connected with main earth dully inc chesing cutting & making good to match with existing surface complete all as specified.
Supply & fixing in replacement of heating element 2.0 KW in built in assembly as per existing make and model incl connection and re-fixing the same complete all as specified.
Supply & fixing in replacement of heating element 1.5 KW in built in assembly as per existing make and model incl connection and re-fixing the same complete all as specified.
S&F in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, completete all as directed and specified, including taking down old unserviceable plug socket and offering for credit.
M & L in replacement of Hot water pipe duly insulated with glass wool and aluminium cladding 25 mm bore complete all as specified and directed.
M & L in replacement of Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete all as specified and directed.
Cleaning of solar water heaters panels of any capacity in position with liquid soap solution, flushing with fresh potable water, sweeping with clean dry cloth and resetting of float valve to maintain the correct level of water in the tank incl cleaning and writting the date of tank cleaning clearly in white letters all as specified by Engineer in charge.
M & L in replacement of insulated steel Tank as per Existing make and size of solar water heater of Cap 100 to 400 ltr as directed by Engineer-in-Charge
M & L in replacement of solar glass tubes as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M & L for replacement of tube holder as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M & L for replacement of copper solar heat pipe as per Existing make and size of solar water heater of Cap 100 to 400 LPD as directed by Engineer-in-Charge
M & L in replacement of Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 25mm bore complete all as specified and directed.
BMMJ TRADERS AND ENGINEERS (BID ID -3086122)
M/S GULATI ENGINEERING WORKS (BID ID -3086120)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .