| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | ₹30.7 L Quoted ₹31.7 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹32.5 LRejected-Finance | ₹32.5 L | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹33.0 LRejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | ₹33.0 L | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹47.0 LRejected-Finance OIL INDIA LTD GATE NO 02 PO UDAYAN VIHAR GUWAHATI ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹47.0 L | L4 | Rejected-Finance Other than L1 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Category not as per NIT |
| Sl No | Description | Qty | Unit | KAKWANI BUILDERS L2 | M/S VSL INFRA & TRADE L1 | A K ENTERPRISE L3 | S. R. TRADING L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Annual comprehensive Maintenance for a period of 06 Months and servicing of DG Set of capacity 380 KVA Make Cummins comprising Diesel Engine , AMF Panel & Control panel for the following job by carrying out the following jobs as given below:-
(a) Draining out engine oil from the chamber cleaning the chamber thoroughly and refilling the oil pan with new engine oil to it’s required level,
(b) Draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel
(c) Supply and replacment of fuel filter set
(d) Supply and replcement of lubricating oil filter set
(e) Supply and replacement By pass filter set
(f) Checking & cleaning air cleaner
(g) Check and topping up coolant level
(h) Checking the starting batteries and filling with electrolyte/Distilled water to maintain the required specific gravity. Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors
(j) Checking and clearning exhaust system including removing of deposited carbon in exhuast pipe.
(k) Adjustment /setting of V Belt and fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer
(l) Checking, cleaning and servicing of self starter, Alternator, sensors etc.
(m) Testing of DG set at connected load all as directed by the Engr in charge.
(n) Replacement of burnout Copper/aluminium thimbles existing size by crimping with crimping tool properly completely. | 2 | Each job | 8,000 ₹16,000 | 17,425 ₹34,850 | 20,000 ₹40,000 | 21,000.5 ₹42,001 |
| 2.00Note (a) Petroleum jelly, waste cloth, seal, gaskets etc are to be provided by the contractor and the cost is deemed to be included in quoted rate. (b) Coolent for topping up and Engine oil, Fuel filter, oil filter, bypass filter, water filter wii be measured and paid saparetly under relevant items. (c) Engine oil /Spares/filters of make reccomended by OEM will only be used for servicing of DG set. Material and Labour for ‘B’ check servicing of all as per manufacturer instructions, including cost of following ‘B’ check spares and minor spares required for carrying out the check like nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolant in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolant from engine and near by spare parts of engine of make Cummins and Alternator make-Stamford and capacity 380 KVA, installed at CZW, complete including testing after repair for its smooth functioning :- (a) Lubricating oil filter - 01 No (b) Filter for Coolant - 01 No (c) Fuel filter - 02 Nos (d) Water Filter - 01 No (e) Minor spares and waste cotton for cleaning - 01 Kit Note : 1. Quoted rate deemed to be included fuel filter kits and lubricating oil filter kits and minor spares required for check. 2. Engine oil, Coolant for radiator, distilled water and new air filter element shall be measured and paid separately under relevant items of this schedule. | |||||||
| 3.00 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 200 KVA, installed at ABOD Adm - 01 Set.
(a) Lubricating oil filter - 02 Nos
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,500 ₹6,500 | 13,260 ₹13,260 | 14,000 ₹14,000 | 15,000.6 ₹15,000.60 |
| 4.00 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 160 KVA installed at FAD Adm Area/Security lights-01 Set and at ABOD NBC Shed-01 Set.
(a) Lubricating oil filter - 02 Nos
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit | 2 | Each job | 6,000 ₹12,000 | 11,390 ₹22,780 | 12,000 ₹24,000 | 13,000.7 ₹26,001.40 |
| 5.00 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed at Filteration plant near 'D' Block-01 Set.
(a) Lubricating oil filter - 02 Nos
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,000 ₹6,000 | 10,965 ₹10,965 | 13,000 ₹13,000 | 13,00,041 ₹13.0 L |
| 6.00 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Bliss and capacity, 125 KVA installed at CPWD PH-01 Set.
(a) Lubricating oil filter- 01 No
(b) Fuel filter - 01 No
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,000 ₹6,000 | 10,800 ₹10,800 | 11,000 ₹11,000 | 11,000 ₹11,000 |
| 7.00 | All as per item No 01 here-in- above but make of alternator and Engine is Crompton Greves and capacity, 125 KVA installed at AC Plant FAD Depot Area.
(a) Lubricating oil filter - 01 No
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,000 ₹6,000 | 9,690 ₹9,690 | 11,000 ₹11,000 | 11,000.56 ₹11,000.56 |
| 8.00 | All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Green and capacity 100 KVA, installed at FAD-01 Set and 41 Veh -01 Set. .
(a) lubricating oil filter - 02 Nos
(b) Fuel filter kit Secondary Element - 01 No
(c) Fuel filter kit primary Element - 01 No.
(d) Minor spares and waste cotton for cleaning - 01 Kit | 2 | Each job | 6,000 ₹12,000 | 11,500 ₹23,000 | 10,500 ₹21,000 | 10,500 ₹21,000 |
| 9.00 | All as per item No 01 here-in- above but make of Engine & Alternator is Kirloskar Bliss and and capacity 100 KVA, installed at Signal Centre Server room - 01 Set.
(a) Lubricating oil filter - 01 No
(b) Fuel filter - 01 No
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,000 ₹6,000 | 9,690 ₹9,690 | 12,000 ₹12,000 | 12,000 ₹12,000 |
| 10.00 | All as per item No 01 here-in- above but make of Engine is Kirloskar and Alternator make-Jyoti and capacity, 75 KVA installed at 51 Sub Area-01 Set.
(a) Lubricating oil filter - 01 No
(b) Fuel filter - 02 Nos
(c) Minor spares and waste cotton for cleaning - 01 Kit | 1 | Each job | 6,000 ₹6,000 | 8,400 ₹8,400 | 10,500 ₹10,500 | 10,500 ₹10,500 |
Updated dates
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
12 Jan 2026, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99APO
REPAIR MAINTENACE OF SEWAGE PUMPS STPS AND CONNECTED WORKS AT VARIOUS LOCATION AND COMPREHENSIVE REPAIR MAINTENANCE OF DG SETS AMF PANELS AND CONNECTED WORKS UNDER GE NARANGI
2025_MES_744636_1
8156/B/E8
Open Tender
Civil Works
180 days
Guwahati
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Narangi
₹74,000
Yes
11 Mar 2026
16 Dec 2025
14 Jan 2026
16 Dec 2025
12 Jan 2026
29 Dec 2025
Material and labour for Annual comprehensive Maintenance for a period of 06 Months and servicing of DG Set of capacity 380 KVA Make Cummins comprising Diesel Engine , AMF Panel & Control panel for the following job by carrying out the following jobs as given below:- (a) Draining out engine oil from the chamber cleaning the chamber thoroughly and refilling the oil pan with new engine oil to it’s required level, (b) Draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel (c) Supply and replacment of fuel filter set (d) Supply and replcement of lubricating oil filter set (e) Supply and replacement By pass filter set (f) Checking & cleaning air cleaner (g) Check and topping up coolant level (h) Checking the starting batteries and filling with electrolyte/Distilled water to maintain the required specific gravity. Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors (j) Checking and clearning exhaust system including removing of deposited carbon in exhuast pipe. (k) Adjustment /setting of V Belt and fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescri
bed by the manufacturer (l) Checking, cleaning and servicing of self starter, Alternator, sensors etc. (m) Testing of DG set at connected load all as directed by the Engr in charge. (n) Replacement of burnout Copper/aluminium thimbles existing size by crimping with crimping tool properly completely.
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 200 KVA, installed at ABOD Adm - 01 Set. (a) Lubricating oil filter - 02 Nos (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 160 KVA installed at FAD Adm Area/Security lights-01 Set and at ABOD NBC Shed-01 Set. (a) Lubricating oil filter - 02 Nos (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 125 KVA installed at Filteration plant near 'D' Block-01 Set. (a) Lubricating oil filter - 02 Nos (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Bliss and capacity, 125 KVA installed at CPWD PH-01 Set. (a) Lubricating oil filter- 01 No (b) Fuel filter - 01 No (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Crompton Greves and capacity, 125 KVA installed at AC Plant FAD Depot Area. (a) Lubricating oil filter - 01 No (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar Green and capacity 100 KVA, installed at FAD-01 Set and 41 Veh -01 Set. . (a) lubricating oil filter - 02 Nos (b) Fuel filter kit Secondary Element - 01 No (c) Fuel filter kit primary Element - 01 No. (d) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of Engine & Alternator is Kirloskar Bliss and and capacity 100 KVA, installed at Signal Centre Server room - 01 Set. (a) Lubricating oil filter - 01 No (b) Fuel filter - 01 No (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of Engine is Kirloskar and Alternator make-Jyoti and capacity, 75 KVA installed at 51 Sub Area-01 Set. (a) Lubricating oil filter - 01 No (b) Fuel filter - 02 Nos (c) Minor spares and waste cotton for cleaning - 01 Kit
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 62.5 KVA installed at 222 ABOD- 01 Set. (a) Filter for lubricating oil - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 here-in- above but make of alternator and Engine (4R1040) is Kirloskar and capacity 50 KVA, installed at Office Area - 01 set. (a) Lubricating oil filter - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 40 KVA installed at MAP CPWD Pump House-01 set. (a) Filter for lubricating oil - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 20 KVA installed at NOI- 01 set. (a) Filter for lubricating oil - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 here-in- above but make of alternator and Engine is Kirloskar and capacity, 15 KVA installed at ADG NEI- 01 set. (a) Filter for lubricating oil - 01 No (b) Fuel filter kit - 01 No
All as per item No 01 here-in- above but Diesel Fire Pump of 105HP/76BHP any make : Kirloskar and capacity, installed at 222 ABOD/14 FAD Fire Pump House-01 set. (a) Filter for lubricating oil - 01 No (b) Fuel filter kit - 01 No (Note : Job Include servicing of Pump complete testing and commissioning all as specified and directed.
Supply only engine oil grade 20W40 against 'B' check servicing and as per the capacity of engine model and as per manufacturers recommendation complete all as directed.
Supply only coolant against 'B' check servicing for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation complete all as directed.
Supply and top up / replace distilled water for battery or radiator of engine used complete all as directed.
Removing existing unserviceble battery and supply and fix lead acid battery maintenance free 12 volts 180AH of make : EXIDE Xpress/SF/LUMINIOUS fully charged complete all as directed.
Material and labour for replacement of unserviceable tachometer with electronic type tachometer of any capacity complete all as directed.
Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifiers, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine including testing/commissioning complete for DG set having any capacity complete all as directed. Note : Replacement of rotor armature coil if required shall be measured and paid seperately.
Replacement of rotor armature coil suitable for battery charging dynamo of DG set complete all as directed.
Supply only solenoid coil suitable for DG set self starter
Supply only armeture coil complete with shaft suitable for DG set self starter
Supply only pinion gear suitable for DG set self starter
Removing existing unserviceble battery and supplied and fixed lead acid battery maintenance free 12 volts 130 AH as per cat part No FXPO-MHD1300 of make EXIDE Xpress fully charged complete all as directed.
Dismantling old unserviceable battery charging dynamo of rating 12 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpm including testing after installation complete all as directed.
Dismantling old unserviceable Self starter of Diesel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing after installation complete all as directed.
Dismantling old unserviceable battery charging dynamo of rating 24 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 rpm including testing after installation complete all as directed.
Supply only power contactor 4 pole, 415 volt, AC1 rating160 Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed.
Supply only power contactor 4 pole, 415 volt, AC1 rating 100Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed.
Supply only power contactor 4 pole, 415 volt, AC1 rating 16 Amp to 40 Amps suitable for AMF panel board complete all as per existing make & model complete all as specified and directed.
Supply only EC2 AMF logic relays, suitable for DG set AMF panel board.
Supply only overload relay suitable for AMF/LT panel board all as per existing make & model complete all as specified and directed.
Supply only SMPS automatic battery charger 12 volt suitable for DG set AMF panel board.
Supply only SMPS automatic battery charger 24 volt suitable for DG set AMF panel board.
Supply only multifunction meter flush mounting accuracy class 1.0 in AMF panel .
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 200 KVA installed at ABOD.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 160 KVA installed at ABOD NBC Shed and at FAD Adm DG Set.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 125 KVA installed at Filteration plant-01 Set
Supply only Air filter element inner and outer suitable for DG set Engine of make Crompton Greaves and capacity 125 KVA installed at AC Plant FAD Depot 01 Set.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at Singal Centre-01 Set
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 100 KVA installed at FAD depo-01 Set & Veh-01 Set
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 75 KVA installed at Sub Area-01 Set and New Filter plant-01 Set.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 62.5 KVA installed at Sewage Treatment plant
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 62.5 KVA installed at ABOD Depot Area.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 50 KVA installed at Office.
Supply only Air filter element suitable for DG set Engine of make Kirloskar and capacity 40 KVA installed at CPWD Pump House.
Supply and fix in repair 'V' belt ribbed of radiator fan belt suitable for DG Set 62.5 KVA to 380 KVA complete all as specified and directed.
Supply and fix in repair 'V' belt ribbed of battery charging dynomo belt, suitable for DG set 62.5 KVA to 380 KVA complete all as specified and directed.
Supply and fix in repair 'V' belt ribbed of water pump belt all suitable for DG set 62.5 KVA to 380KVA complete all as specified and directed.
Supply and fix in repair 'V' belt ribbed of radiator fan belt/ battery charging dynomo belt/water pump belt suitable for DG set 15 KVA to 20 KVA any type complete all as specified and directed.
Supply only Air filter element suitable for DG set Engine of make Cummins and capacity 380 KVA installed at ABW.
Material and labour for draining out coolant water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute Hydro Chloric Acid, kerosene, fresh water and refixing the same with new rubber hose with clamps filling with coolant with distilled water and checking for its proper function on DG set all as directed and specified. Note : Coolant and distilled water shall be measured and paid separately under relavant items.
Taking down old UNSV and Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 sqmm complete all as specified and directed.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 40 KVA to 75 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 100 KVA to 200 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity 380 KVA and above all as per existing sample with GI clamps and Nut bolt, washers for DG set complete all as directed.
Supply and fix MCCB with Thermal - magnetic release of 80-100 Amps, 3 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one. Note:- Any modifications for fixing the MCCB's in the existing AMF Panel or LT Panel reqd, the cost for this modifications along with cable lugs or thimbles & spreader.
Supply and fix MCCB with Thermal - magnetic release of 250 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one.
Supply and fix in repair ON LOAD change over switch, 4 pole, 415 Volts, 200 Amps capacity open execution type complete all as directed.
Supply and fix MCCB with Thermal - magnetic release of 125-160 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icu with adjustable over load setting and adjustable short circuit setting including all accessories and taking down old unserviceable one.
Repairs to turbo charger complete all as directed.
Cleaning of DG set fuel tank of capacity upto 100 KVA by draining out residual oil and removal of sludge from bottom of the tank complete all as directed.
All as per Item No. 69 but capacity exceeding100 KVA but not exceeding 200 KVA
Repairs to automatic voltage regulator (AVR) including replacement of electronic printed circuit board (PCB) and wire connections of alternator of any capacity complete all as specified and directed.
All as per Item No. 69 but capacity exceeding 200 KVA but not exceeding 380 KVA
Supply and fix repair/ replacment of battery charger fixed on panel board o
f 12V/24V DC from 230V AC as existing complete all as including replacement of electronic printed circuit board (PCB) and wire connections complete all as specified and directed.
Supply and fix in repairs solenoid switch with fuel shut off valve compatible to auto mains failure panel for remote operation complete all as specified and directed.
Supply and fix in repairs battery terminal leads of 2AWG (35sqmm) copper wire single core PVC insulated 1.5m long of colour coding red or black complete with brass terminals fixed at site with petroleum jelly complete all as specified and directed.
Supply and fix in repair MCB TP 25 to 63 A, 415V,50Hz, C series breaking capacity 10kA all as specified and directed.
Supply and fix centrifugal gear driven,Cast iron body water pump assembly suiatable for 62.5 KVA to 200 KVA Kirloskar Diesel Engine Cooling system complete all as specified and directed.
Supply and fix Cast iron body pressure fuel pump assembly suiatable for 62.5 KVA to 200 KVA of existing make and model complete all as specified and directed.
Material and labour for servicing of Newely installed Diesel Engine Generator set of 100 KVA by taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages complete all as specified and directed. Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM & Engine oil shall be measured and paid separately under relevant item of this schedule.
Material and labour for servicing of Newely installed Diesel Engine Generator set of 15 KVA by taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages complete all as specified and directed. Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM & Engine oil shall be measured and paid separately under relevant item of this schedule
Material and labour for servicing of Newely installed Diesel Engine Generator set of 250 KVA make Greaves CPCB IV+ by taking down oil sump after draining unserviceable enigne oil from drain plug and storing in a container, cleaning the sump and refilling Engine oil, running testing and refilling as top up for proper level, greasing the movable parts and cleaning complete body after repairing all oil / fuel leakages, include all type of filters and topping up urea tank complete all as specified and directed. Note:- Servicing to be carried out by service engineer of OEM/auth rep of OEM & Engine oil, filters any type shall be measured and paid separately under relevant item of this schedule
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
Supply and fixing in repairs battery charger for 12 V battery in sheet metal enclosure having voltmeter and ammeter of capacity 10 Amps with two Nos lead with terminal clamps complete all as specified and directed. of AMF panel of make as per existing complete all as specified and directed.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 70 Sq mm 3.5 core including taking down complete all as specified and directed
Material and labour sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Supply and fix bricks using sub class ‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cable perpendicular to direction of cable, complete all as specified and directed.
Supply only super enameled copper conductor wire suitable gauge and size as per requirement for rewinding of Alternator of capacity 62.5 KVA to 200 KVA complete all as specified and directed.
Supply and fixing as in repair metal fuel injector pipe of make Lucas TVS / Mico suitable for DG Set of make Kirloskar / Mahindra / Ashok Leyland of capacity 62.5 KVA to 380 KVA complete all as specified and directed
Supply and fixing as in repair metal flexible fuel pipe having both end benjo nuts or as per sample complete all as specified and directed
Material and labour for repairing, welding doors to main body include AMF Panel board, hinges fitting, replacement of lock, handle and making good for the canopy of DG set /panel baord off capacity including painting with exixting colour after surface preparation complete all as specified and directed by Engineer in charge
Supply and topping up of coolent for DG set in sealed container Make as recommended by OEM of DG Set complete all as specified and directed .
Repair to alternator of DG set 20 KVA to 100 KVA, servicing, greasing of alternator, cleaning the dust including replacement of defective rectifier of suitable capacity, testing complete of alternator for out put voltage and load etc complete all as specified and directed .
Repair to alternator of DG set 125 KVA to 380 KVA, servicing, alternator, cleaning the dust including replacement of defective rectifier of suitable capacity, testing complete of alternator for out put voltage and load etc complete all as specified and directed .
Material and labour for servicing of self starter 12/24V of DG Set any make and capacit
y include cleaning and replacement of bushes complete all as specified and directed.
Supply and fix Fuel filter assembly of make LUCAS/TVS suitable for DG Set of any make of rating 62.5 KVA to 125 KVA complete all as specified and directed.
Supply and fix Fuel filter assembly of make LUCAS/TVS suitable for DG Set of any make of rating 200 KVA to 380 KVA complete all as specified and directed.
Supply and fix Radiator Cap of DG Set include chain complete all as specified and directed.
Supply and fix Micor processor based controller fixed in DG of capacity 62.5 to 125 KVA of make as existing include testing and commissioning complete all as specified and directed.
Taking down old and Supply and fix Micro processor based controller fixed in DG of capacity 200 KVA of make & Model as existing include testing and commissioning complete all as specified and directed.
Taking down old and Supply and fix Micro processor based ECPG controller fixed in DG of capacity 380 KVA of make & Model as existing include testing and commissioning complete all as specified and directed.
Supply and fix Micor processor based Relay card fixed in DG of capacity 62.5 to 125 KVA of make as existing include testing and commissioning complete all as specified and directed.
Supply and fix Brass Battery terminal Heavy duty having nuts & bolts complete all as specified and directed .
Supply only Cylinder Linear (6 Nos)
Supply only Piston Assy
Supply only Piston Ring
Supply only C R Bearing
Supply only Head Gasket
Supply only Gasket Kit
Supply only Engine Valve
Supply only Valve Valve Guide
Supply only Valve Seat
Supply only Valve oil Seal
Supply only Lube oil filter
Supply only Fuel Filter
Supply only Lube oil 15W40
Supply only Copper washer
Supply only Hose Pipe
Supply only U Ring Kit
Supply only Air Filter
Supply only Cylinder Linear (6 Nos)
Supply only Piston Assy
Supply only Piston Assy
Supply only C R Bearing
Supply only Piston Ring
Supply only C R Bearing
Supply only Gasket Kit
Supply only Valve Valve Guide
Supply only Valve Guide
Supply only Valve oil Seal
Supply only Lube oil filter
Supply only Valve Seat
Supply only Valve oil Seal
Supply only Fuel Filter
Supply only Coolant
Supply only Linear O Ring
Supply only Air Filter
Material and labour for filling Diseal Exhaust fluid (Urea) required for DG Sets having CPCB IV+ catagory.
Material and lanour for Strip opening of 12.5 HP to 15HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works.
Replacement of tungstun mechanical shaft seal for sewage pump application as per OEM .
Replacement of oil seal in non clog submersible sewage motor pump set of any rating as per OEM .
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
Replacement of DE roller bearing as per OEM .
Replacement of NDE ball bearingas per OEM .
Material and labour for filling Diseal Exhaust fluid (Urea) required for DG Sets having CPCB IV+ catagory.
Material and lanour for Strip opening of 12.5 HP to 15HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works.
Replacement of tungstun mechanical shaft seal for sewage pump application as per OEM .
Replacement of set of O rings .
Reparing of impeller shaft in non clog submersible sewage pump set of any capacity by metal filling, machining, turning and lathe work in wksp complete include testing and ciommissioning.
Supply and filling insulation oil as per OEM .
Material and lanour for Strip opening of 25 HP 3 phase AC Non clog submersible pumpset any type taking out burnt winding coil complete and re-winding with PVC insulated super quality water proof winding wire including seal PVC (water proof compound) and jointing new submersible cable at least 6m long with water proof tape all as specified and directed and re-assembling the motor and testing compelete of the following rating:- Note : Rates include all required T&P shall be supplied by the contractor include transportation of motor from site to workshop and back to site after necessary repair works.
Replacement of set of O rings.
Supply and fix CI/GI bend of suitable size including suitable for non clog pump complete including nuts & bolts, rubber gasket complete.
Supply and fix MS chain closed type of size 12mm including round ring insert on every mtr include chain lock, Nuts & Bolts fixed on non clog sewage submersible pump complete all as specified and directed .
Repairing of existing starter/panel by disconnecting existing burn out cable/ wiring and replaced with 1.5 Sqmm single core copper conductor or suitable size as per existing cable include replacement of Digital Volt meter, Digital Amp Meter alongwith CTs, relays, making connection, replacement of cable lugs of suitable size, repair/replacement of locking arrangement include painting with two coat of synthetic enamel paint complete all as specified and directed. Note : Repalcement of contractor, relay, MCCBs, Volt Meter & Amp Meter will be measured & paid seperately.
Supply and fix in replacement of Voltmeters having LED display, accuracy class 1.0,0.5, Input voltage measurement rane 50-520VAC, Au supply 80-300 VAC/DC, flush mounting type 96x96mm complete including fixing in panel board complete all as specified and directed.
Supply and fix Copper Spreaders link Terminals (set of 8) of voltage upto 690V AC, suitbale for 250 Amps MCCBs complete all as specified and dir
ected.
Supply and fixing in repair Star Delta Starter in sheet metal enclosure suitable for 15 HP motor, 3 Phase, 415 Volt. complete all as specified and directed.
Supply only single phase preventer to protect motor for phase failure complete all as specified and direced.
Supply and fixing in repair DOL Starter suitable for 1 to 5 HP 440 Volt. complete all as specified and directed.
Supply only Contactor ML/MNX or equivalent of 16/25Amps, 415 volts complete all as specified and directed.
Supply only Contactor ML/MNX or equivalent of 32/40Amps, 415 volts complete all as specified and directed.
Supply only delay timer relay suitable for starter up to 25HP complete all as specified and directed.
Supply and fix Indicator lamp LED type of RYB colour , 230 Volts.complete all as specified and directed.
Material and lanour for MCCB TP NL LT 415 volt 50 Hz, AC 125 amps 25 KA with thermal magnetic release for OL & SC protectioncomplete all as specified and directed.
Material and lanour for MCCB TP NL LT 415 volt 50 Hz, AC 250 amps 25 KA with thermal magnetic release for OL & SC protection complete all as specified and directed
Supply only Thermal Over load relay of rating 6- 10 Amps, 3Ph, 415 Volts, as existing complete all as specified and directed .
Supply only Thermal Over load relay of rating 20- 33 Amps, 3Ph, 415 Volts, as existing complete all as specified and directed .
Supply only Electronic timer switch 3 to 120 Sec of 240/415V, 50 Hz , as existing complete all as specified and directed
Material and labour for replacement of timer switch as existing for running air compressor alternately include electric connections complete all as specified and directed.
Each Job
Supply and fix in replacement of cast iron suice valve 100 mm dia both side flanged PN-1.6 conforming to IS 14846 (ISI marked) with stainless steel spindle and iron wheel non raising type including, nuts and bolts. complete all as specified and directed.
Supply and fix in replacement of cast iron non return valve 100 mm dia both side flanged (ISI Marked) confirming to IS 5312 (Pt-I) including nut & bolts. complete all as specified and directed.
Supply and fix in replacement of stainer valve 100 mm dia both side flanged (ISI Marked) confirming to IS 5312 (Pt-I) including nut & bolts. complete all as specified and directed.
Material and labour for taking out compost /manure from drying filter beds of size 4000X4000X1800mm (04 Nos) by digging / sraping the all material manually and loading the material into civil truck and sprayed / dumped the manure outside of MOD land where no disturbance to human beings will occur and make manure free up to the filter media of drying bed complete all as specified and directed.
Material and labour for Cement concrete in 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in foundation filling and mass concrete including dismantling of existing concrete complete all as specified and directed.
Taking out the sewage water sample from Raw sewage water/Treated sewage water from STP and carry out the test for 12 parameters as per indian standard specifications (IS-3025 (Part- 1, 17, 16, 58, 44, 35, 39, 34, 31) & (IS- 1622) from Govt approved lab or NABL accreded lab complete all as specified and directed.
Taking down old UNSV pipe and Supply and fix PVC pipe (SWR pipe) of pressure rating 6 kgf/cm2 laid in trenches with all fittings laid in trenches/fixed to walls complete of size 75mm dia. complete all as specified and directed.
Taking down old UNSV pipe and Supply and fix PVC pipe (SWR pipe) of pressure rating 6 kgf/cm2 laid in trenches with all fittings laid in trenches/fixed to walls complete of size 150mm dia.
Taking down old valve and Supply & fixing Butterfly valve flanged type, confirming to IS 14846 suitable for 150 mm bore pipe complete all as specified.
Material and lanour for cleaning/lifting of sludge by taking out submersible non clogging pump sets from sewage well including dismantling all connections and keeping aside for reinstalling after comprehensive cleaning of sewage treatment plant reservoirs at Phase-II area such as collection cum equalization tank, CC tank, tube settler tank and clear water sump by dewatering and removal of existing sludge from various chambers and scrapping off after draining out waste/sludge and depositing to a suitable location as directed at site, cleaning of all reservoirs mentioned above using bleaching powder and wire brush and wiping off properly including sun drying before re commissioning at site complete all as specified and as directed. Note: Proper shut down shall be taken before commencement of subject work
Material and lanour for lifting of submersible non clogging pump set of capacity upto 12.5 HP from sewage well including dismantling all connections and keeping aside for reinstalling after comprehensive cleaning of sewage well by extracting complete sewage settlements/sludge/mud/waste particles and disposal at a distance not exceeding 50 metre from the sewage pump house complete to the entire satisfaction of Engr-in-charge complete all as specified and as directed.
Taking out old UNSV MS Angle/ channel/ Sheet from Open well & Jack well sumps and supply & fabricated MS Covers from 50x50x6mm thck MS Angle Iron frame, MS sheet of size 3mm thick, MS rods, (Fe.290.Gde-E-165) include handle for lifting complete include painting with one coat of Red oxide paint and two coat of synthetic enamel paint as per existing size complete all as specified and directed. (Note : Job include cutting corroded structure by welding, fabrication of new structure by welding, cutting and fixing with suitable arrangements).
Material and lanour for Scrubbing cleaning the exterior surface of OH sewage pump house at STP, 0.9 MLD outer surface complete as existing colour and applying two coats of cement base paint on the outer surfaces and two coats of synthetic enamel paint on electric panel and MS structure , pipe line, air lines etc as per existing colour code include marking with white colour include DI/MS sewage line etc complete all as specified and directed
Material and lanour for Scrubbing cleaning the exterior surface of UG sump and applying two coats of cement base paint on the outer surface and two coats of synthetic enamel paint on ladder fitted from ground to reservoir or MS structure & applying two coat of lime on inner surface of walls complete all as specified and directed. (Sewage Sump at D & E block)
Supply and fixing in replacement of ribbed V Belt of existing size for air blowers complete all as specified and directed.
Taking down existing 2 to 4 core UG cable disconnect from panel board, proper dressing, replacement of cable lugs of appropriate size and refixing the same in porperly complete all as specified and directed.
Taking down old UNSV light fittings and Supply and fixing LED flood light 100watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant include MS bracket , nuts & bolts fixed on wall or OHT pillar, or MS Structure complete with driver and lamp include pipe bracket and MS frame complete all as specified and directed.
Taking down old UNSV fittings and Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Taking down / up unserviceable XLPE LT cable of size up to 16 Sqmm to 50Sqmm 3-1//4core complete all as specified and directed by Engineer-in-charge. (Note: Earth work to be measured and paid under relavent item of this schedule)
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade corss-sectional area 50 Sq mm 3.5core complete all as specified and directed by Engineer-in-charge. (Note: Excavation & Thimbles to be measured and paid under relavent items of this schedule)
Material and labour for PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) as in foundation filling
and mass concrete including dismantling of existing concrete complete all as specified and directed.
Material and lanour for taking out existing filter media from Iron removal plant or Pressure fillter of cap 6000 GPH of any description carefully and removing out to distance 50 Mtrs away from pump house, including cleaning, washing inside of filter including painting Inside & Outside, replacement of UNSV PVC threaded hose pipe, rubber washers, Nuts & Bolts , testing and comissioning complete all as specified and directed.
Supply and fix and leveling gravel of size 20 x 12mm thickness as per OEM design complete all as specified and directed.
Supply and fix and leveling gravel of size 12 x 6mm thickness as per OEM design complete all as specified and directed.
Supply and fix and leveling gravel of size 6 x 3mm thickness as per OEM design complete all as specified and directed.
Supply and fix and leveling gravel of size 3 x 1.5mm thickness as per OEM design complete all as specified and directed.
Supply, laying and and levelling Activated carbon (Arthritic coal) as per OEM design for forming media filter of filter complete all as specified and as directed .
Supply and fix and leveling fine sand of size 0.45mm to 1mm as per OEM design complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8156Tender.pdf
Tender Documents • 0.66 MB
BOQ_833788.xls
BOQ • 13.48 MB
Download all tender documents and submit your bid