| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.4 L+₹49,116.32 (3.30%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹16.6 L+₹1.8 L (11.9%)Rejected-Finance | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹28.7 L+₹13.8 L (92.6%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
5 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR MAINT TO EM NATURE OF WORKS AT HAZIPIR LINE SHEKHAWATI LINE OLD NEW NPG LINE UNDER GE WEST DELHI CANTT 10
2021_MES_434726_1
GE/DW-48/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹95,000
26 Jul 2021
9 Jun 2021
12 Jul 2021
10 Jun 2021
5 Jul 2021
23 Jun 2021
90 days
Amount
Checking and attending complaints by experience tradesman means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 2. Complaints noted'' NO Light,Short circuit,Sparking,Burning etc issues in electric circuits shall be attended imediately up to 2200 hrs on same day without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 3. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape,screws,nut & bolts,washers,fan holding bushes, etc shall deemed to be included in the quoted rate of this item. 4.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 5. Contracror shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed. 6. Contractor or his rep will report daily at complaint cell at SHEKHAWATI LINE area for collection of complaints from the concerned JE in charge . 7 Job slip as per sample shall be provided by the contractor free of cost. 8. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account. 9.All Items Required to replace such as switches,sockets,call bells,Bell push,Capacitors,Plug Tops,Metal clad sockets,ceiling roses,light fittings,fan regulators,MCBs,MCB DB's,MCCB's,security lights,all materials except fixing accessories etc any capacityshall be issued by the department free for fixing and labour shall be paid unde respect items of this BOQ 10.Item required to replace in repairs based on Day to Day complaints by the users as when as required as site. 11.Old unserviceable material obtained from site against issued by the department to be deposited to MES store Yard.
S&F MS down rod 300 mm for fixing of ceiling fan all as specified and directed
S&F Ceiling fan blade 1200mm sweep for fixing of ceiling fan all as specified and directed.
S&F hot press moulded SMC meter box of inside dimensions 250x150x155mm with hinged doors fixed on new plywood to wall size of 500x450x10mm complete all as specified and directed. Make: Sintex or equivalent
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
All as per item No. 7 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
M&L for concealed point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in and including PVC concealed conduit ISI marked of suitable size medium grade with PVC conduit fittings such as tees, bends, elbow, reducers including cutting, chasing and making good to the disturbed surface, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing moduler switches/sockets etc with cover plate/3mm thick plastic laminated sheet for one light / fan / exhaust fan / circulator fan / bell/ buzzer controlled by one 1-way switch complete all as specified and directed .
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
All as per item No. 13 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S & F in Repair of socket 6 A 250V AC universal polycarbonate complete all as specified and directed.
S & F in Repair of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S & F in Repair of Bell push single pole one way complete all as specified and directed.
S & F in Repair of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S & F in Repair of Socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S & F in Repair of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
S&F of switch piano flush button type 5 amps single pole two way complete all as specified and directed.
Supply, laying and drawing submain wiring in existing concealed PVC rigid conduit on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
M&L for rewinding exhaust fan of 300mm/450mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
M&L in repair lower shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 99640.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/s Adhikari construction co.
SETHI ENTERPRISES
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .