Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | ₹20.8 L Quoted ₹21.3 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹23.9 L+₹2.5 L (11.8%)Rejected-Finance VILL JAMALPUR P O NAYA MAHMMADPUR DISTT BHOJPUR ARA PIN 802163 | ARA | BHOJPUR | BIHAR | 802163 | ₹23.9 L+₹2.5 L (11.8%) | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹24.3 L+₹2.9 L (13.8%)Rejected-Finance W D BUILDING JP ROAD BHARALUMUKH GUWAHATI 781009 ASSAM | KAMRUP METRO | ASSAM | 781009 | ₹24.3 L+₹2.9 L (13.8%) | L3 | Rejected-Finance Other than Lowest Bidder |
| 4 | L4₹24.4 L+₹3.1 L (14.3%)Rejected-Finance | ₹24.4 L+₹3.1 L (14.3%) | L4 | Rejected-Finance Other than Lowest Bidder |
| 5 | L5₹26.0 L+₹4.6 L (21.8%)Rejected-Finance 0 BINOVA NAGAR KAMRUP ASSAM 781018 UDYAM AS 03 0029196 | KAMRUP METRO | ASSAM | 781018 | ₹26.0 L+₹4.6 L (21.8%) | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Aug 2021, 6:00 pmClosed
GE NARANGI
GE Narangi C/O 99 APO Guwahati
CERTAIN B R REPAIR AND INTERNAL ELECTRIFICATION WORKS AT VARIOUS ACCN AT THIMMAYA MARG UNDER GE NARANGI.
2021_MES_463697_1
8663/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE NARANGI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NARANGI
₹60,000
Yes
27 Nov 2021
29 Jul 2021
28 Aug 2021
29 Jul 2021
25 Aug 2021
12 Aug 2021
Amount
SCHEDULE 'A' PART-I
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed.
S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' type or 'J' type or cranked hook bolts and washers, in roof covering, walls cladding etc, with grade of zinc coating 275 complete all as specified and as directed.
Refixing only galvanised corrugated mild steel sheeting as obtained from dismantling of old sheets here in before with two corrugation side lap, fixed with & including 'L' type or 'J' type or cranked hook bolts in roof covering, wall cladding etc., complete all as specified and as directed.
S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of colour as approved by GE having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by GE having tensile strength of 550 Mpa as in ridges,valley complete all as specified and as directed.
Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed.
S&F 6 mm thick asbestos cement corrugated or semi corrugated sheet with side lap, fixed with 'L' or 'J' type or cranked hook bolts, nuts & washers etc.complete all as specified and as directed.
Refixing only asbestos cement corrugated or semi corrugated sheet as obtained from dismantling of old sheets with side lap, fixed with 'L' or 'J' type or cranked hook bolts, nuts and washers complete all as specified and as directed.
S&F 6 mm thick asbestos cement two piece adjustable serrated ridge, corrugated or semi corrugated sheet fixed with 'L' or 'J' type or cranked hook bolts, nuts & washers complete all as specified and directed.
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing in positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid including dismantling of old existing ceiling of any description and type complete all as specified and as directed.
Demolition of plain cement concrete (Un-reinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M & L for 75 mm thick PCC 1:2:4, type B2 (using 40 mm graded stone aggregates) as in path / paving / hard standing / floor and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per item No 15 here in before but except bricks. Note: Old serviceable bricks as obtained from demolition here-in-before shall be reused under this item complete all as specified and as directed.
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer including a coat of 1.00 mm thick (average) wall care putty complete all as specified and as directed.
M&L for complete removal of old treated surfaces on walls and applying one coat of alkali resistant primer and a coat of wall care putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of cement base paint complete all as specified and as directed.
Dismantling timber scantling 40Sqcm and over in section as in framed work in any position complete all as specified and as directed.
M&L for 2nd class hard wood, in scantlings, clean sawn timber as in framed work complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each including builders hardware complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 Sqm but not exceeding 4 Sqm each including builders hardware complete all as specified and as directed.
Taking down shutter of any description n exc 1 Sqm each complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
M&L for 1.25mm thick mild steel pressed steel frames of size 105x60mm for doors with single rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M&L for PCC 1:3:6 type C0 (using 12.5mm graded stone aggregate) as in filling the hollow portion of steel frame, hold fast etc complete all as specified and directed.
S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S & F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specfication, drawing and complete all as specified and as directed.
M&L for anodized aluminium push pull type partly panelled and partly glazed door shutter (single leaf / double leaf) having top rail of section 85.00mm×44.45mm×2.00mm, bottom rail of section 85.00mm×44.45mm×2.00mm thick, door verticals of section 44.45mm×44.45mm×2.00mm thick and lock rail of section 85.00 mm× 44.45mmx2.00mm thick with aluminium anodized frame of section 63.50mm x 33.10mmx2.50mm thick including necessary jointing cleats, glazing clips, rubber packing snap beading, screws, handle and locking arrangements etc, including 12mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick float glass tinted quality on top panel and including 1 No of aluminium door closer per leaf (Diecast) body hydraulically regulated designation No 3 universal type complete all as specified and as directed.
M & L for Anodized aluminium sliding glazed window shutter (double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) without sash bars with anodized aluminium shutter of section 40.00 mm x 20.00 mm x 1.10 mm thick and window chowkat of section 92.00 mm x 29.50 mm x 1.20 mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, tower bolts and locking arrangement etc. and 4 mm thick sheet glass, tinted quality on panel and aluminium anodized wire cloth for mosquito proofing, 0.45 mm nominal dia and average width of aperture 1.40 mm fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed.
S & F steel windows with side hung shutters glazed shutter including both side openable (out side glazed window and inside fly proof window) including projecting type hinges with steel handle and steel peg stay complete with glazing bars and 12 mm square bar or round bar of approved design welded to steel window frame dovetailed or welded complete all as specified and directed . Note: Guard bar or square bar shall be measure and paid separately.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed.
S & F in repairs, aluminium door closer (Diecast) body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and complete all as specified and as directed.
S & F in repairs, double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F in repairs, brass Mortice lock, Vertical type of size 100mm 2 levers complete all as specified and as directed..
S & F stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F 3 mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed.
M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles 300mmx200mmx7mm thick, set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match including 10 mm thick screed bed or bedding layers in CM (1:4) complete all as specified and directed.
Taking up or down 15 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed.
S & F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing old serviceable 15 mm bore steel tubing and connections as obtained from taking down including provision of new fittings, in new or old position of walls, ceiling, floor etc. complete all as specified and as directed.
Taking up or down 20 mm bore GI tubing from trenches / wall including all fittings segregated, cleaning and stacking the pipe for reuse at site if required complete all as specified and as directed. Note : Excavation and earthwork if any shall be included in the quoted rate.
S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Refixing old serviceable 20 mm bore steel tubing and connections as obtained from taking down including provision of new fittings, in new or old position of walls, ceiling, floor etc. complete all as specified and as directed.
S & F 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc including dismantling of old tank of any description complete all as specified and as directed.
S & F 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including dismantling of old tank of any description complete all as specified and as directed.
S&F in repair 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and as directed.
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 72 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board
All as per item serial No 72 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item serial No 72 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC rigid conduit on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 76 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 76 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item serial No 76 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, modular switch , flush type single pole one way 6 Amps 240 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
S&F in repairs, modular switch , flush type single pole one way 16 Amps 240 volt complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp flush type 240 volts complete all as specified and as directed.
S&F in repairs, socket outlet 3 Pin 15 Amp 240 volts complete all as specified and as directed.
S&F in repairs, modular Socket outlet 2 in 1, 3 Pin 6 Amp/16Amp flush type 240 volts complete all as specified and as directed.
S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S & F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F in repairs, lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S&F in repairs, ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S & F stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
S&F in repairs, stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
S&F in repairs, modular stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed.
Dressing of pre-wired casing caping /PVC conduit of One light /fan/ exhaust fan point controlled by one number one way 5 Amp switch by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit , screws etc) complete all as specified and directed.
Taking out existing unserviceable switch board plates any type, dismantling switches carefully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6 inch x 10 inch MS box with brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper multistranded cable complete all as specified and as directed. (Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items).
All as per item No102 here-in-above but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 8 inch MS box.
Taking down carefully by unscrewing from board/outlet boxes, fitting and fixturessuch as switches, sockets,ceiling rose, lamp holders, brackets ceiling fitting ,bulkhead fitting, tube light fitting and regulator etc for reuse at site or carring to the store ( To be measured only when found in all respect complete for reuse) and making good disturbed surface of wall, flooretc complete all as directed by Engineer-in-Charge.
Refixing serviceable fittings/ fixtures as obtained from serial item no 104 here in before and connecting up with suitable size cable in location as directed by the Eng In charge .
S&F in repairs, LED box type fitting of regal batten pre-wired including LED tube 1x20W ,fixed on PVC block connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed. Make:- Havells Model-REGALBATTENT8UPTO1X22WDSBSWH +CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Philips /GE/Crompton
S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Crompton
S&F in repairs LED (double sided connection) ) ultra bright polycarbonate tube light 18/20 watt retrofit in existing flourescent tube light . Make Havells/crompton/Bajaj/Jaquar or euivalent.
S&F in repairs, 34 watt LED recessed mounted luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling and fixture size in mm (LxWxH) 595x595x70mm complete all as specified and as directed. Make : Havells Model-PLUTONEO2x2PLR34WLED840S/ PLUTONEO2x2PLR34WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
S&F in repairs, 18w recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and integrated driver complete all as specified and as directed. Make: Havells Model : EDGEPRORDDLR18WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
S&F in repairs,15 watt LED recessed mounted luminaire with high brightness LED for glare-free homogenous illumination suitable for Armstrong/grid ceiling and fixture size in mm (LxWxH) 295x295x70 complete all as specified and as directed. Make : Havells Model- PLUTO1x1PLR15WLED840S/PLUTO1x1PLR15WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
S&F in repairs,15 watt LED recessed mounted luminaire edgepro round with high brightness LED for glare-free homogenous illumination suitable for ceiling and cutout Ø 180 mm, height 16 mm complete all as specified and as directed.a Make- Havells EDGEPRO, Cat Part No-EDGEPRORDDLR15WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
S&F in repairs, LED recess mount downlighter 15 W with pressure die-cast aluminium heat sink and PC diffuser in white powder coated finish with integrated driver complete all as specified and as directed. Make- Havells Cat Part No-ENDURANEOHESURFACEDLS15WLED857S or equivalent model of make Philips /GE/Crompton.
S&F in repairs, of LED PL-L/Bi Pin lamp 18W/20W of any type/size of downlighter complete all as specified and as directed.
S&F in repairs wall mounted decorative luminaire in design mesh suitable for 9W LED lamp B22 base ,including lamp 15watt complete all as specified and as directed. Make -Havells, cat no-LHDL07150099 or equivalent in crompton, Bajaj, Jaquar
S&F in repairs Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips / Crompton /GE.
S&F in repairs LED building security luminaries 35 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: Havells CAT No. ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC or equivalent of Philips/Wipro/CG
S & F in repairs, LED 40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and as directed .Make -Bajaj ,cat no-BGCL 40W LED WH or equivalent model of make Philips /GE/Crompton.
S&F in repairs, constant current LED driver suitable for LED luminaries downlighter of 12 to 36 watt complete all as specified and as directed .
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 2.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
S&F in repairs, cable junction box of size 130x130x77mm , IP66 with metric knockout for cable entry (Dust and power jet proof according to IEC 60529), shock proof, rust free ,corrosion free acid and chemical resistant ,fire retardant having high impact (IK08) totally insulated (class II) made of halogen and silica free recyclable material UV resistant having high grade gasket made of polyurethane ,one no MCB DP 6 Amps with locking arrangement and M40 size cable gland and one M32 size gland suitable for 2.5-6.0 sqmm cable complete as directed. Make : HENSEL cat no-DK 0600 G or equivalent.
S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or equivalent. model in Siemens / Schneider
S&F in repairs, MCCB DB IP-43 of sheet metal enclosure double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed. Make- Legrand cat No-5077 45. or equivalent. model in Siemens / Schnider
S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or equivalent model in Siemens / Schneider/L&T
S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F in repairs, MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F in repairs, MCB TPN 40 to 63Amps, 415V,50 HZ,C series breaking capacity 10KA complete all as specified and as directed. Make- Legrand ,cat part no-4086 81 to 83 equivalent model of make Siemens/Schnider.
S&F in repair for MCCBs 415 V, 16 KA, 4P, 63 Amps complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F in repairs, MCCB 100 Amps, 415V , 16 KA 4 pole complete all as specified and as directed. Make :- Legrand Cat No 4200 15 or equivalent model of make Siemens/Schnider.
Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of pre-connected MCBs by changing screw of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 1.5 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.5 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 1.5 Sqmm cable and 1 run of 1.5 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.)
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting to MES E/M store yard, and refixing on same location or other location complete all as specified and as directed.( Cost of repairing including replacement of spares if any will be measured and paiid seperately under relevent items of this schedule.
Strip opening of ceiling fan 1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC ceiling fan 1200 mm//1400mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan. (Make : Usha/Asian/EPCOS/Universal).
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed.
Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
Taking down exhaust fan of size 200mm to 300mm sweep of any make and transporting from any location to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note:- Cutting the existing copper winding, rewinding, Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items .
Cutting the existing copper winding of AC exhaust fan 200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing suitable for exhaust fan 300 mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI
Supply only condenser ISI marked 230/240/250 volts AC 4.0 Mfd suitable for exhaust Fans complete all as specified and as directed. (Make : Usha/Asian/EPCOS/Universal).
M & L for painting of ceiling/exhaust fan complete with blades ,in situ with synthetic enamel paint Duco by spraying including filling cavities with filler ,ones coat after cleaning all dust etc.complete all as specified and as directed.
S&F in repairs, Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic light duty body of size 230 mm sweep,anti dust with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm and making good surface complete all as specified and directed. Make-Havells, Model-Ventil Air - DS or equivalent model of make Bajaj /Crompton. Note:- Old Fan to be deposited in MES store yard.
S&F in repairs, ventilating fans AC single phase 230/ 240 V of size 250 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint 2 cm high in letter complete with necessary connection up including provision of three core copper flexible cable with flexible wire cover of plastic white in colour and connection from ceiling rose to exhaust fan terminal etc complete all as specified and as directed. Note:- Old Fan to be deposited in MES store yard. Make-Usha, Model-CRISP AIR LX EXHAUST FAN or equivalent make in Crompton, Bajaj
S&F in repairs, wall fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 400 mm sweep,and necessary connecting items with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm and making good surface complete all as specified and as directed. Make-USHA, Model-400 MM MIST AIR Duos or equivalent model of make Havells/Bajaj /Crompton. Note:- old fan deposited to MES Store.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed.
J K CONSTRUCTION
PK ENGINEERING
M/s KRISHNA CONSTRUCTIONS
KAMAKHYA CONSTRUCTION & BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .