Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.4 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹77.0 L+₹60,499 (0.79%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹86.9 L+₹10.5 L (13.7%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹90.8 L+₹14.4 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Firm is not enlisted in b ii category |
| Sl No | Description | Qty | Unit | M/S Anil Enterprises L4 | KEWAL SONS L1 | MAHESH KUMAR SINGLA CONTRACTOR L2 | Roy and Sons Infrastructures L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for disconnecting, lifting, loading and transportation of unserviceable transformer indoor/outdoor type 11000/433 Volts of capacity 63 KVA to 400 KVA from site to MES yard complete, all as specified and directed by Engineer-in-Charge. Note :- (i) The quoted rates shall deemed to include for the transportation, T&P, Labours from site to yard. | 11 | Each Job | 3,000 ₹33,000 Lowest | 5,000 ₹55,000 | 5,000 ₹55,000 | 8,000 ₹88,000 |
| 2.00 | Supply and Installation, Testing & Commissioning of Transformer, Step-down, 11/0.433 volts, outdoor type, AC 3 Phase, 50 Hz, double copper wound, oil immersed,naturally cooled (ON AN) with external cooling tubes/fins, vector group DYN-11 with neutral brought out on (LV side) to vary secondary voltage within limit at ± 2.5% to be changed by means of hand operated off load tappings on HT side, all as per IS:1180 Part-III (2021) of capacity 100 KVA capacity along with all standerd fittings shall comprise of the following:-
(a) One cable box on HT side (Primary side) consisting of 3 Nos porcelin bushings with copper rods complete with nuts & bolts along with washer including gasket.
(b) One cable box on LT side (secondry side) consisting of 4 Nos porcelin bushings with copper rods complete with nuts & bolts along with washer including gasket.
(c) Oil conservator with oil level guge. (d) Dehydating breather with first fill of dehydrating agent (Silica gel) (e) Explosion vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs, oil filling hole with cap/plug, air release valve plug & 4 Nos plain solid cast steel detachable rollers. (f) One 100 mm dia dial type thermometer, vapour pressure type, having range 0-120°c having maximum temparature reading indicator with resetting. (g) Two earthing terminals on tnk cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body. (h) Rating plate & terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First filling of new & unused transformer oil, IS-335 marked (Make-Power oil) & tested upto 40 KV di-electric strength at 2.5 mm air gap between testing electrodes.
Note : (i) The rates include for supplying transformers with all standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning.
(ii) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in quoted rates)
(iii) Transformer shall be fitted with MS channel of size 100x50mm below the transformer wheel complete set painted with two coats of cement base paint over a primer complete as per specified and directed by the Engr-in- charge. | 4 | Each | 5,28,500 ₹21,14,000 | 3,83,000 ₹15,32,000 Lowest | 5,65,000 ₹22,60,000 | 5,80,000 ₹23,20,000 |
| 3.00 | All as per item No-02 but of capacity 160 KVA capacity. | 1 | Each | 7,43,000 ₹7,43,000 | 6,69,000 ₹6,69,000 | 6,13,999 ₹6,13,999 Lowest | 6,65,000 ₹6,65,000 |
| 4.00 | All as per item No-02 of capacity 200 KVA capacity. | 4 | Each | 9,51,900 ₹38,07,600 | 7,99,000 ₹31,96,000 | 7,00,000 ₹28,00,000 Lowest | 7,80,000 ₹31,20,000 |
| 5.00 | All as per item No-02 of capacity 250 KVA capacity. | 2 | Each | 9,81,100 ₹19,62,200 | 8,69,000 ₹17,38,000 | 7,50,000 ₹15,00,000 Lowest | 8,60,000 ₹17,20,000 |
| 6.00 | Demolition of plain cement concrete of any description and in any position of plinth of transformer all as specified and directed. | 7 | Cum | 200 ₹1,400 Lowest | 1,000 ₹7,000 | 500 ₹3,500 | 3,000 ₹21,000 |
| 7.00 | M&L PCC 1:3:6, type C1, (using 20mm graded crushed stone aggregate) as in coping/pedestal/foundation for transformer/ of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed. | 35 | Cum | 2,900 ₹1,01,500 | 4,000 ₹1,40,000 | 2,500 ₹87,500 Lowest | 6,000 ₹2,10,000 |
| 8.00 | M&L PCC 1:3:6, type C2, (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete. | 7 | Cum | 2,800 ₹19,600 | 4,500 ₹31,500 | 2,500 ₹17,500 Lowest | 7,000 ₹49,000 |
| 9.00 | Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core cable laid in trenches/passing through pipe under road crossing etc all as specified and directed. | 30 | Rm | 1,325 ₹39,750 | 1,300 ₹39,000 | 1,200 ₹36,000 | 1,175 ₹35,250 Lowest |
| 10.00 | All as per item No 09 but size 150 Sqmm 3.5 Core. | 50 | Rm | 1,045 ₹52,250 | 1,000 ₹50,000 | 1,050 ₹52,500 | 930 ₹46,500 Lowest |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
4 Mar 2026, 6:00 pmClosed
COMMANDER WORKS ENGINEER
HQ CWE HISAR HISAR MIL STN HISAR
SPL REPAIR FOR REPLACEMENT OF TRANSFORMERS AGAINST BER AND ALLIED WORKS UNDER GE ALWAR
2026_MES_751275_1
CWE/HSR/ALW-79 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
ALWAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE ALWAR
₹1.4 L
11 Apr 2026
4 Feb 2026
6 Mar 2026
4 Feb 2026
4 Mar 2026
25 Feb 2026
5 Feb 2026 - 12 Feb 2026
M&L for disconnecting, lifting, loading and transportation of unserviceable transformer indoor/outdoor type 11000/433 Volts of capacity 63 KVA to 400 KVA from site to MES yard complete, all as specified and directed by Engineer-in-Charge. Note :- (i) The quoted rates shall deemed to include for the transportation, T&P, Labours from site to yard.
Supply and Installation, Testing & Commissioning of Transformer, Step-down, 11/0.433 volts, outdoor type, AC 3 Phase, 50 Hz, double copper wound, oil immersed,naturally cooled (ON AN) with external cooling tubes/fins, vector group DYN-11 with neutral brought out on (LV side) to vary secondary voltage within limit at ± 2.5% to be changed by means of hand operated off load tappings on HT side, all as per IS:1180 Part-III (2021) of capacity 100 KVA capacity along with all standerd fittings shall comprise of the following:- (a) One cable box on HT side (Primary side) consisting of 3 Nos porcelin bushings with copper rods complete with nuts & bolts along with washer including gasket. (b) One cable box on LT side (secondry side) consisting of 4 Nos porcelin bushings with copper rods complete with nuts & bolts along with washer including gasket. (c) Oil conservator with oil level guge. (d) Dehydating breather with first fill of dehydrating agent (Silica gel) (e) Explosion vent, thermometer pocket on tank cover, oil drain filter valve, lifting lugs, oil filling hole with cap/plug, air release valve plug & 4 Nos plain solid cast steel detachable rollers. (f) One 100 mm dia dial type thermometer, vapour pressure type, having range 0-120°c having maximum temparature reading indicator with resetting. (g) Two earthing terminals on tnk cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body. (h) Rating plate & terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First filling of new & unused transformer oil, IS-335 marked (Make-Power oil) & tested upto 40 KV di-electric strength at 2.5 mm air gap between testing electrodes. Note : (i) The rates include for supplying transformers with all standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (ii) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in quoted rates) (iii) Transformer shall be fitted with MS channel of size 100x50mm below the transformer wheel complete set painted with two coats of cement base paint over a primer complete as per specified and directed by the Engr-in- charge.
All as per item No-02 but of capacity 160 KVA capacity.
All as per item No-02 of capacity 200 KVA capacity.
All as per item No-02 of capacity 250 KVA capacity.
Demolition of plain cement concrete of any description and in any position of plinth of transformer all as specified and directed.
M&L PCC 1:3:6, type C1, (using 20mm graded crushed stone aggregate) as in coping/pedestal/foundation for transformer/ of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
M&L PCC 1:3:6, type C2, (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete.
Supply, lay, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core cable laid in trenches/passing through pipe under road crossing etc all as specified and directed.
All as per item No 09 but size 150 Sqmm 3.5 Core.
All as per item No 09 but size 120 Sqmm 3.5 Core.
M&L for earthing to electric equipments / panels etc with and including galvanized MS earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5m below ground level as shown in electrical plate No 3 of SSR Part I, the earth plate surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all sides, excavation & earth work in any type of soil and removal of surplus soil upto 50m including galvanized mild steel strip 32mm x 6mm as earth lead, welding at top of electrode and other end of strip connected to equipment body/panel/test point with two Nos nuts bolts or welding with steel structure,GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 3.00 metre above ground level fixed along equipment body/panel with and including 25x3mm FI clamps, bolts, nuts and washers, PCC chamber (1:3:6) type C1, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering, 75 mm thick RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling, taking out old existing unserviceable earthing & depositing to MES store.
stage.html
html • 0.05 MB
technical_841423.pdf
techsummary_841423.pdf
finance_841423.pdf
BOQ Comparative Chart
xlsx
finsummary_841423.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
8868tender.pdf
Tender Documents • 1.03 MB
BOQ_841423.xls
BOQ • 7.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .