| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹8.3 L+₹1.5 L (21.9%)Rejected-Finance 499 A VIDHYUT NAGAR A AJMER ROAD JAIPUR 302021 | JAIPUR | JAIPUR | RAJASTHAN | 302021 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹8.3 L+₹1.5 L (22.0%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹9.1 L+₹2.2 L (32.8%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹9.1 L+₹2.3 L (33.5%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
11 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jaipur
HQ CWE Kalyan Marg Jaipur
REPAIR AND MAINT TO SECURITY LIGHTS AT MUNDOTA AND NIWARU MIL STN
2021_MES_466939_1
CWE/82084/JPRN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I)(P) Niwaru Jaipur
Enlisted with MES in Class E and above and category b (I)
7 documents required · 7 mandatory
₹500
Yes
AGE(I)(P) Niwaru Jaipur
₹26,000
Yes
24 Sept 2021
10 Aug 2021
14 Sept 2021
10 Aug 2021
11 Sept 2021
30 Aug 2021
60 days
Amount
Fixing only in repair and replacement of street light fitting LED type/ Flood light of any type capacity to existing poles/bldgs/High mast light and connecting with existing cable, including nuts, bolts and washer etc complete all as specified & as directed. Note: - (i) LED street light/flood light will be issued under Sch ‘B’ free for fixing only. (ii) Disconnecting of old existing non functional street light/flood lights fitting of any type from poles/High Mast/Bldgs shall become property of contractor vide Sch of Credit. (iii) T&P required for above work such as ladder, Crane vehicle, manpower etc, are deemed to be included in quoted rate (iv) Rate of necessary arrangement for fixing LED light on existing bracket like reducer or extension of pipe by suitable size of GI pipe as per dia of LED light/Flood lights by welding etc are deemed to be included in quoted rate.
Supply and fix in replacement, PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable, 1100 volt, confirming to IS :694 and size of cable 1.5 Sqmm 2 core complete all as specified & as directed. Note- (i) Cable is reqd to be connected from street light to junction box with proper lugs.
S& F in replacement cable junction box of size 350x250x150 for outdoor installation IP-65 protected made of polycarbonate with necessary clamps (2 Nos) for mounting on poles, comprising with copper bus bar for 3 phases and neutral of required amps capacity for cable size 16 to 35 sqmm 4 core, phase and neutral fixed on porcelain insulator and MCB, SP 0.5 to 6 amps, 10 KA - 01 Nos complete all as specified and directed.
S & F in replacement of timer switch for street light three phase 110- 240 V AC 1 C/O Base /DIN 25 ON/OFF complete all as specified and directed.
S & F in replacement of contactor 22 Amp for street light timer, three phase 415 V AC 50 Hz as per existing complete all as specified and directed.
S & F contactor 40 Amp for street light timer, three phase 415 V AC 50 Hz as per existing complete all as specified and directed.
Supply and fix in repairs MCB’s single pole with neutral, 6 Amps,10KA, 250 volts with ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and directed.
Taking out & rewinding the existing unserviceable burnt induction motor 1.5 HP, three phase, 50 cycles by disconnecting electrically, mechanically and transporting to the locally contractors workshop. Dismantling the motor and removing the old burnt copper winding & de-moisturised, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings, re-metaling of armature shaft and turning on lathe to give proper size for bearing fittings, replacement of terminal plate and installed with all connection electrical and mechanically, testing, commissioning etc complete all as specified and directed.
Supply & laying in replacement LT cable XLPE insulated screened PVC bedded galvanised steel strips or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade ISI marked, laid in trenches/under road/floor or on wall complete all as specified and directed of following Size of cable:-
(a) 10 Sqmm, 2 core cable
(b) 16 Sqmm, 4 core cable
(c) 25 Sqmm, 4 core cable
(d) 35 Sqmm, 3.5 core cable
Laying only in repair and replacement of cable XLPE insulated armoured cables with stranded aluminium conductor, 1100 volts grade including connecting and testing laid in trench/floors/ roads or on walls/poles complete all as specified and directed of following size of cable:- Note:- (i) Earth work, excavation shall be measured & paid separately under respective item of Schedule). (ii) Cables will be issued under Sch ‘B’ free for fixing only.
(a) 6 Sqmm, 2 core cable
(a) 50 Sqmm, 3.5 core cable
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
M&L for sand cushioning to PVC underground cable with crush stone sand and punning to provide a required cover complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supply and laying old size bricks, common burnt clay building bricks sub class ‘B’ designation 75 laid in trenches over sand for cable protection etc complete all as specified & directed.
Supply & fixing or laying in repair galvanised steel tubing light grade (ISI marked) 40mm bore for protection of underground cable on poles / walls under road crossing etc complete all as specified & directed.
Supply & fixing or laying in repair galvanised steel tubing light grade (ISI marked) 50mm bore for protection of underground cable on poles / walls under road crossing etc complete all as specified & directed.
Schedule of Credit
DIVYA ASSOCIATES
Choudhary Traders and Engineers
GLOBAL ENGINEERS AND INNOVATORS
M/S M P SHARMA
AARTI ENTERPRISES
Bhawani Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .