Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.6 L+₹1.9 L (5.53%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹36.9 L+₹2.2 L (6.36%)Rejected-AOC | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹41.8 L+₹7.1 L (20.5%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹42.9 L+₹8.2 L (23.7%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Nov 2022, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/REPLACEMENT OF PUMP CONTROL PANEL,EARTHINGS,COPPER CABLE,AVIATION LIGHTENING,PROTECTION, WATERLEVEL INDICATORS, ALLIED WORKS AT GRPH,MCEME,DEPOT BN,EME RECORDS,NML,OHL, ECO,FALAKNAMA,AGAMAN AND ADJOINING AREA UNDER AGEE/M-II OF GE(U)SECBAD
2022_MES_558126_1
GE(U)/SEC/TOKEN/43 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER UTILITY SECUNDERABAD
₹96,000
Yes
15 Jun 2023
17 Oct 2022
19 Nov 2022
17 Oct 2022
12 Nov 2022
31 Oct 2022
Amount
S&F for power contactor with coil voltage of 440 volts, 50 cycle confirming to IS, 300 Amps, 3 pole, type MNX-225 with necessary inter connections suitable for 150 to 180 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T cat No : CS94141 or equivalent in IndoAsian/Leagrand as approved by GE.
S&F for spare contact kit of voltage of 440 volts, 50 cycle conforming to IS, 200 to 250 Amps, 3 pole, type mnx 225 OF l&t with kit necessary inter connections suitable for200 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T cat No : CS90310 or equivalent in Siemens /Leagrand as approved by GE.
S&F for power contactor with coil voltage of 440 volts, 50 cycle confirming to IS, 300 Amps, 3 pole, type MNX-250 with necessary inter connections suitable for 150 to 180 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T cat No : CS94141 or equivalent in IndoAsian/Leagrand as approved by GE
S&F for spare contact kit of voltage of 440 volts, 50 cycle conforming to IS, 200 to 250 Amps, 3 pole, type mnx 250 OF l&t with kit necessary inter connections suitable for200 HP electric motor, testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T cat No : CS90310 or equivalent in Siemens /Leagrand as approved by GE
S&F for spare coil for power contactor of 440 volts, 50 cycle confirming to IS, 200 to 250 Amps rating suitable for 40 HP to 220 HP electric motor, type MNX 250/MNX300/MNX225 testing and commissioning including removing the old existing one complete all as specified and directed. Make : L&T or equivalent as approved by GE
Supply and fix thermal overload relay with built in single phase prevention (CT Operated), 3 phase of capacity 180-300 Amps suitable for 3 phase star delta starter, type MN12, 440 volts with necessary fixing materials including disconnecting and removing the old existing one complete all as specified and directed. Make :- L&T Cat No : SS94139OOQO or equivalent make in Siemens /Leagrand
Supply and fix electronic timer switch ST 100, 240/360/415 volts, Range 3 to 30 sec with mounting kit suitable for old existing ET 100 replacement complete all as specified and directed. Make :- L&T Cat No : ST80328OOOO or equivalent in Siemens /Leagrand as approved by GE
supply and replace heavyduty GI suction pipe of size 50 mm with all arrangements including o1 Nos long bends complete all as directed. Note : Quoted rates are deemed to be inclusive of all arrangement required for replacement of unserviceable suction pipe including taking down, disconnecting and refixing of Foot valve, testing complete
supply and replace heavyduty GI suction pipe of size 65 mm with all arrangements including o1 Nos long bends complete all as directed . Note : Quoted rates are deemed to be inclusive of all arrangement required for replacement of unserviceable suction pipe including taking down, disconnecting and refixing of Foot valve, testing complete
supply and replace heavyduty GI suction pipe of size80 mm with all arrangements including o1 Nos long bends complete all as directed . Note : Quoted rates are deemed to be inclusive of all arrangement required for replacement of unserviceable suction pipe including taking down, disconnecting and refixing of Foot valve, testing complete
Supply and fix in replacement of Copper cable lugs of following sizes complete all as specified and directed :-
120 to 150 sq mm
185 to 400 sq mm
S&F for replacement of carbon brush suitable for Electric motor for the following capacities complete all as specified and directed :-
Motor 200 - 220 HP capacity
Motor 150 - 180 HP capacity
M&L for replacement of brass slip ring, 3 phase, 415 Volts suitable for up to 220 HP capacity slip ring motor complete all as specified and directed.
Dismantling and strip opening the centrifugal/ monoblock pump including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refixing the same after repairs including overhauling the pump set, renewal of gasket to pump suction and delivery lines, gland packing, greasing nuts, bolts and washers,Metal Sleeves, painting ,all kind of grinding & welding work , replacement of bearing, etc as required for arresting any kind of water leakages including testing and commissioning complete all as specified and directed for the following capacities as mentioned below :
Pump 3 phase 200 to 220 HP capacity.
Pump 3 phase 10 to 40 HP capacity.
Pump 3 phase 7.5 HP capacity.
Pump 3 phase 3 to 5 HP capacity.
Pump set 3 phase/ Single Phase 1 HP upto 2 HP capacity.
Notes for item Nos 14.01 to 14.05:- (i) The rate quoted is deemed to be inclusive of tools and plants including transportation of pump set from site to workshop and back required for carrying out the repairs. (ii) The rate quoted is deemed to be inclusive of cost towards miscellaneous items such as cotton waste, grease, Gland packing, nut bolts , all kind of grinding, welding work , gasket and other minor consumables. The cost of other spares for pump measured and paid separately under appropriate items. (iii) The rate quoted is deemed to be inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for pump not mentioned above will be considered separately under appropriate items.
Dismantling and strip opening the centrifugal/ INDUCTION motor including disconnecting the cable connections and coupling of the motor, removing the starter and rotor units, bearings, servicing the motor assembly including cleaning the corbon deposits with corbon tetra chloride, greasing the bearings etc, heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the mositure evoporates completely at authorized workshop and refixing the same after repairs including connecting up of the electric connections including testing and commissioning complete all as specified for the following capacities :-
Motor 3 Phase 200 to 220HP capacity.
Motor 3 Phase 20 to 40 HP capacity.
Motor 3 Phase 10 to 15 HP capacity.
Motor 3 Phase 5 HP to 7.5 HP capacity.
Motor 3 Phase / 1 Phase 1 HP To 3 HP capacity
Notes for item Nos 15.01 to 15.06:- (i) The rate quoted is deemed to be inclusive of tools and plants including transportation of motor from site to workshop and back required for carrying out the repairs. (ii) The rate quoted is deemed to be inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii) The rate quoted is deemed to be inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The cost of spares for motor shall be paid separately under appropriate items.
M&L for rewinding the centifugal/ Monoblock electric motor stator or rotor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed of following capacities :-
Stator winding of Electric motor, 3 phase, 200 to 220 HP capacity.
Stator winding of Electric motor, 3 phase,20 to 40 HP capacity.
Stator winding of Electric motor, 3 phase, 10 to 15 HP capacity.
Startor Winding of Electric Motor, 7.5 HP capacity.
Startor Winding of Electric Motor, 5 HP capacity.
Winding of Electric Motor 1 HP to 3 HP capacity.
Supply only the spare part of Non Drive End Bearing suitable for make of motor existing at site as in repairs for the following capacities of motors complete all as specified and directed :-
Motor, 3 phase, capacity 200 to 220 HP.
Motor, 3 phase, capacity 20 to 40 HP .
Motor, 3 phase, capacity 10 to 15 HP .
Motor, 3 phase, capacity 7.5 HP.
Motor, 3 phase, capacity 5 HP.
Motor, 3 / 1 phase up to 3 HP capacity
Supply only the spare part of Drive End Bearing suitable for make of motor existing at site for repairs of the following capacities of motors complete all as specified and directed :-
Motor, 3 phase, capacity 200 to 220 HP.
Motor, 3 phase, capacity 20 to 40 HP .
Motor, 3 phase, capacity 10 to 15 HP .
Motor, 3 phase, capacity 7.5 HP.
Motor, 3 phase, capacity 5 HP.
Motor, 3 / 1 phase up to 3 HP capacity
Supply only the ball bearing/roller bearing (For Non-Drive End) suitable for make of pump existing at site for repairs of the following capacities of pumps complete all as specified and directed :-
Pump, fitted with 3 phase motor of capacity 200 to 220 HP.
Pump, fitted with 3 phase motor of capacity 20 to 40 HP .
Pump, fitted with 3 phase motor of capacity 10 to 15 HP.
Pump, fitted with 3 phase motor of capacity 7.5 HP.
Pump, fitted with 3 phase motor of capacity 5 HP.
Pump fitted with 3 /1 phase motor of capacity up to 3 HP capacity
Supply only the ball bearing/roller bearing (For Drive End) suitable for make of pump existing at site for repairs of the following capacities of pumps complete all as specified and directed :-
Pump, fitted with 3 phase motor of capacity 200 to 220 HP.
Pump, fitted with 3 phase motor of capacity 20 to 40 HP .
Pump, fitted with 3 phase motor of capacity 10 to 15 HP.
Pump, fitted with 3 phase motor of capacity 7.5 HP.
Pump, fitted with 3 phase motor of capacity 5 HP.
Pump fitted with 3 /1 phase motor of capacity up to 3 HP capacity
Supply only the following spares suitable for make existing at site of pump 2 stage 70 LPS capacity for repairs complete all as specified and directed :-
Pump shaft suitable for 2 stage impeller of capacity 70 LPS.
Cast Iron impeller Ist stage suitable for 70 LPS pump
Cast Iron impeller IInd stage suitable for 70 LPS pump.
Cast Iron bearing cover for drive and non drive end for pump of capacity 70 LPS
Cast iron inter stage ring for pump of capacity 70 LPS.
Rubber for water reflector for pump
Cast Iron shaft sleeve for drive end for pump of capacity 70 LPS.
Cast Iron shaft sleeve for non drive end for pump of capacity 70 LPS..
Cast Iron spacer sleeve for drive end for pump of capacity 70 LPS.
Cast Iron spacer sleeve for non drive end for pump of capacity 70 LPS..
Lock nut round type for pump of capacity 70 LPS.
Bronze nut for shaft sleeve for pump
Stuffing box bush cast Iron for pump
Gland packing for pump of capacity 70 LPS.
Set of key for pump set
Set of ‘O’ ring for pumps
Set of gaskets 3.0mm thick as per sample set of ‘O’ ring for pumps.
Cast iron gland set of 2 halves for pump of capacity 70 LPS Make of Pumps & Motors for item Nos: 21.01 to 21.18:- KIRLOSKAR/BEACON WEIR/DECON AIRCON/CG
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well upto 450 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely.
Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 5 HP to 10 HP and taking out the pump set alongwith pipes and fittings for flushing the bore well above 450 feet and upto 750 feet depth or repair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely.
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Submersible Motor upto and including 5 HP.
Submersible Motor above 5 HP up to 10 HP.
Supply only the following spares suitable for existing make of submersible/centrifugal pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed :-
Gun metal Impeller.
Stage casing.
SS Sleeves.
Middle bush.(LB)
Middle sleeve.
Discharge outlet.(LB)
Pump coupling.
DOL SS Sleeve.
Suction bush.
Pump Shaft
Supply only the following spares for repairs of centrifugal / monoblock pump set of up to 10 HP capacity complete all as specified and directed :-
Ball bearing suitable for induction motor.
Ball bearing for non drive end suitable for pump.
GM bush.
CI impeller.
MS pump shaft.
Gland cover.
Supply only the following spares for repairs of centrifugal / monoblock pump set of above 10 HP and up to 40 hp capacity complete all as specified and directed :-
Ball bearing suitable for induction motor.
Ball bearing for non drive end suitable for pump.
GM bush.
CI impeller.
MS pump shaft.
Gland cover.
Complete removal of existing treatment including preparation of old painted surfaces by washing, rubbing down and stopping of painted surfaces, painting with one coat of synthetic enamel paint of approved colour on centrifugal pump set of 180 HP to 220 HP capacity including inlet, outlet mains, couplings, sluice valve, non return valve, base plate, pulley with safe gaurd, vacuum pipe line, LT panel board and writting the MES / SM number with black paint of suitable size of letters complete all as specified and directed.
All as per item No-28 here-in-before but for 10 HP to 40 HP centrifugal pump set.
All as per item No-28 here-in-before but for up to 7.5 HP centrifugal pump set.
Supply and installation CPRI approved Pump Starter electric control panel board, for In door use, single door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size 50mmx50mmx6mm, having electrolytic high conductivity insulated bus bar made but of aluminium strips of rating 200 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level including disconnecting / taking out old existing unsv pump panel complete all as specified and directed of the following :-
INCOMMING : (a) MCCB, 4 pole, 415 Volt, 100 Amps, 25 kA - 01 No. Make :- Havells/ Benlo or equivalent as approved by GE (b) 3 Phase LED Voltmeter, Class-0.5 - 01 No. Make :- L&T or equivalent as approved by GE. (c) 3 Phase LED Ammeter, Class-0.5 - 01 No. Make :- L&T or equivalent as approved by GE (d) LED Indicator lamp in three colour RYB - 01 Set. OUTGOING : (a) MCB Isolator, 3 pole, 415 Volt, 63 Amps - 03 No's. Make :- Benlo/Havells or equivalent as approved by GE (b) DOL Starter in sheet enclosure type MK-1, Motor rating AC-3 Duty, 415 Volt, 50 Hz of 10 HP/7.5 KW, relay max range 15-25 Amps - 02 No's. Make :- L&T or equivalent as approved by GE (c) Single Phase Preventer Relay type Sz5 (6 Wire), 415 Volt - 02 No's. Make :- L&T or equivalent as approved by GE.
Supply and replace heavy duty long socket suitable for 50 mm dia heavy duty GI pipe complete all as specified and directed
Supply and fix on wallmounted name plate of motors by using acrylic sheet 3 mm thick of size 45 CM X30 CM mentioning Office name , capacity of motors, Sl Number , mes No, date of installation etc by using colour strip complete all as directed by engineer -in -Charge
S&F PVC insulated, unarmoured, heavy duty electric cables of 150 Sqmm single core with stranded copper conductor, 1100 volts laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors / equipment etc cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
S&F PVC insulated Copper conductor, sheathed, Submersible flat cables of size 4 Sqmm, 3 core, for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
S&F PVC insulated Copper conductor, sheathed, Submersible flat cables of size 2.5 Sqmm, 3 core, for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed.
Supply and fixing of DOL Starter suitable for upto 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp as in repairs complete all as specified and as directed. Makes : L&T cat part No CS90947 or equivalent of Havells/CG as approved as approved by GE.
Supply and fixing of single phase preventer suitable for upto 7.5 HP motor as in repairs complete all as specified and as directed. Make : L&T cat part No CS94824DOOO or equivalent of Havell/MINILAC as approved by GE.
Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLE door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size 50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)) :-
INCOMMING :- (a) MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 Set OUTGOING :- (a) MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No (b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No. (c) Single hase preventor realy type Sz5 (6wire), 415 volts -01 No
Supply and fix BRASS non return (reflux) valve screwed end with gun metal seat type of size 80 mm. Make : Kartar/kirloskar/durga/zoloto
Supply and fix BRASS non return (reflux) valve screwed end with gun metal seat type of size 65 mm. Make : Kartar/kirloskar/durga/zoloto
Supply and fix BRASS non return (reflux) valve screwed end with gun metal seat type of size 50 mm. Make : Kartar/kirloskar/durga/zoloto
Supply and fix BRASS non return (reflux) valve screwed end with gun metal seat type of size 40 mm. Make : Kartar/kirloskar/durga/zoloto
Supply and fix Cast iron foot valve swing type flanged of size 50 mm as per IS 4038 . Make : Kartar/kirloskar/durga
Supply and fix Cast iron foot valve swing type flanged of size 65 mm as per IS 4038 . Make : Kartar/kirloskar/durga
Supply and fix Cast iron foot valve swing type flanged of size 80 mm as per IS 4038. Make : Kartar/kirloskar/durga
Supply and fix Cast iron foot valve swing type flanged of size 100 mm as per IS 4038. Make : Kartar/kirloskar/durga
Note for item number 41 to 48 : Quoted rates are deemed to be inclusive of all arrangements required for replacement of unserviceable Foot valve / NRV including removing and refixing of suction pipe from sump as required on ground
Supply and fix Contactor 40 amps 3 phase coil operating operating voltage 230 volt. Make : L&T model cs94190
Supply and fix Contactor 25 amps 3 phase coil operating operating voltage 230 volt. Make : L&T model cs94110
Supply and fix MCB SP&N 32 Amps 10 KA C Curve . Make : L&T model BB20320C /Legrand/havells
Supply and fix MCB SP&N 25 Amps 10 KA C Curve . Make : L&T model BB20325C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB SP&N 20 Amps 10 KA C Curve. Make : L&T model BB20200C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP&N 20 Amps 10 KA C Curve. Make : L&T model BB40200C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP&N 32 Amps 10 KA C Curve. Make : L&T model BB40320C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP&N 63 Amps 10 KA C Curve. Make : L&T model BB406300C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP 20 Amps 10 KA C Curve. Make : L&T model BB30200C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP 32 Amps 10 KA C Curve. Make : L&t model BB30320C or equivalent in Legrand/havells as approved by GE.
Supply and fix MCB TP 63 Amps 10 KA C Curve . Make L&T model BB306300C v
Supply only Calcium Hypochlorite calcium based high strength granular chlorine having 55 % - 65 % chlorine content packed in 45 Kgs PVC sealed container, superior quality suitable for treatment of drinking water (Much more stable than chlorine gas, bleaching power and sodium hypochlorite) all as specified and directed. Note :- Approval of chemical (calcium hypochlorite) shall be given after verifaction of test certificates of chemical of various manufactures and other factores like chemical and safety and health hazard aspects of usage of chlorination . Make of the chlorination of chemical must be stated in production of certificate duly certified by govt laboratory conforming compliance of specification suitable for drinking water with a declartion from the laboratory that from the technical strengh stability health safety and operation point of view , this product is used for drinking water applications for consumption by humans and the brand/make of calcium hypochlorite is suitable for drinking water chlorination and its sample has been tested by Govt Laboratory. Traditional means of chemical shall be used subject to fulfil the parameters specified in the manual on water supply and treatment (Third edition May 1999) issued by Central Public Health and Environmental Engineering Organisation (CPHEEO), Ministry of Urban Development New Delhi. The contractor shall produce manufacturers "Certificate of Compliance" indicating date of manufacturer in original alongwith every consignment of supply. Test certificate from Govt approved Test Laboratory shall accompany with every consignment of supply to ensure that the materials supplied are in with conformity with relevant IS.
Supply only Bleaching powder Grade-I, IS 1065:1989(used in drinking water), stable dry free flowing white in appearance without hard lumps and visible impurities in laminated high density polythene bags of 25 Kgs capacityof each bags. Make : ADITYA BIRLA CHEMICALS LTD (DC) /RAMCO/GRASIM/DCM
Notes for item No 60 to 61 :- (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed by Engr-in-Charge at various installation of AGE E/M No-II. (ii) The quoted rate is deemed to be included complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost.
Supply and fix Submersible pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 6 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make L&T model number ss97756 or equivalent from siemens /abb/schneider as approved by GE.
Supply and fix Submersible pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 13-21 Amps complete all including necessary connections complete all as directed. Make L&T model number ss95983 or equivalent from siemens /abb/schneider as approved by GE.
Supply and fix DOL starter AC 3 duty 415 volt suitable for 10 HP motor relay range 09-15 Amps with single phase protection complete all including necessary connections complete all as directed. Make : L&T model number ss94351 or equivalent from siemens /abb/schneider as approved by GE.
Supply and fix Submersible pump controller fully automatic DOL starter AC 3 duty 415 volt suitable for 7.5 HP motor relay range 9-14 Amps complete all including necessary connections complete all as directed. Make : L&T model number SS96210 or equivalent from siemens /abb/schneider as approved by GE.
Supply and replace thermal over load relay in existing DOL starter of capacity 5hp/7.5 HP as per existing relay range complete all as directed.
Supply and replace thermal over load relay in existing DOL starter of capacity 10 HP as per existing relay range complete all as directed.
M&L Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) as in foundation , PCC, protection of pipe etc , etc., complete all as specified and as directed.
Disconnecting, dismantling and taking aside the Pump set of 150 to 220 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 180 / 220 HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump set testing and commissioning all as specified and directed. Note:The quoted rate is deemed to be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation.
Disconnecting, dismantling and taking aside the Pump set of 10 to 25 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 10 / 25 HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump set testing and commissioning all as specified and directed. Note:The quoted rate is deemed to be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation.
Disconnecting, dismantling and taking aside the Pump set of 05 to 7.5 HP capacity for replacement of existing base frame with new one from the installed position and dismantling of existing PCC / RCC foundation and refixing the same motor by preparing sufficient PCC foundation and base frame reqiured for 5hp/7.5 hp HP pump including connecting items like nuts, bolts and setting the alignemnt of motor and pump set testing and commissioning all as specified and directed. Note:The quoted rate is deemed to be inclusive of required replacement of baseframe/MS channel and PCC / RCC for foundation.
Material labour for removing Submersible pump motor set of capacity up to 7.5 HP stuck in side the borewell of depth up to 100 meter by flushing the existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and column pipe, necessary electric connection and testing complete all as specified and directed . Note; Quoted rate is deemed to be inclusive of Flushing by using suitable compressure, rod drilling for clearing of bore well, Removing the submersible pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of column pipe, electrical connections, testing etc as required .
Arresting lekages from pumps of motor capacity 150 to 220 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Quoted rate is deemed to be inclusive of all items as requiree to arrest the leakages from pumps
Arresting lekages from pumps of motor capacity 05 HP to 25 HP by replacing gasket, nutbolts, gland packing etc as required complete all as directed Note: Quoted rate is deemed to be inclusive of all items as requiree to arrest the leakages from pumps
M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) as in Side Wall of Cable Duct, etc., complete all as specified and as directed.
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for Single Side Painted flex gloss sign board fabrication with 20mm dia mild steel SQ hallow pipe frame and four side and back side in covered with 23mm gauge plain galvanized sheets incl wiring latter diagram photography and making design covering the front surface as directed by Engr-in-Charge including necessary electrical connection complete and dismantling existing old one
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. The earting pit cover should be factorty built (size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed.
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
M&L cross arm bracing supports, clamp and back plate from structural steel section including nuts & bolts washer, welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated or as directed and including of one coat primer, one under coat and one finishing coat of aluminium paint for making clamp to be used for fixing of flood light /street light on pole..
Material and labour for Rubber mat of size 1mX2mX20mm ISI marked
Material and labour for Rubber mat of size 1mX2mX10mm ISI marked
Supply and fix aluminium strip 25 x 4 mm including replacement of insulating blocks complete all as specified and directed.
Supply and replace thermal overload relay 405 a to 7.5amp in existing starter panel board of 180 /220 hp motor including its connector base complete all as directed. Make : L&T model MN2 cat number SS9414100U0 and connector suitable for the relay
Supply and lay pipe galvanized, "Heavy class"' including fittings(long socket) 50mm dia in replacement at borewell
Attending Breakdown of any capacity any type ( Submersible , Monoblock, Cetrifugal etc) of PUMP SETS , Starter panel by Technitian and Helper for checking all parts and rectify the faults and give reports to concern JE as directed by Engr-In-Charge Note : All spare parts to be replaced and paid against respective items.
Supply & lowering HDPE heavy duty column pipe in bore well af ter fixing with submersible pupmsets of internal dia 50mm PN 16kq/Sqmm including necessary fixing arrangement with Submersible motor, and necessary clamp for supporting at the top portion of bore well complete all as d specified and directed. Make : Sudhakar Note: Quoted rate is deemed to be inclusive of lowering of pipe in bore well, necessary connection with MOTOR by using GI fittings, clamps , nutbolts etc as required of heavy duty, 2 sets of clamps for supporting of pipes at the TOP
M&L for flushing of existing borewells of any size upto 150 Mtrs depth with drilling compressor mounted on truck including surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of water samples for chemical and bacteriological tests and complete all as specified and directed .
Taking up or down steel tubing laid in trenches, on wall/in floor, in plinth protection of Bldg including segregation of serviceable pipes and keep in safe custody for reuse, complete with all fittings and connections of the following sizes:-
25 mm dia
40 mm dia
50 mm dia
Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in wall , trenches and testing for leakages complete all as specified and directed for the following sizes:- NOTE : Quoted rate is deemed to be inclusive of all kind of fittings, bends, flenge , thread cutting etc as required for proper fixing of pipe
25 mm dia
40 mm dia
50 mm dia
Supply and replace coupling including rubber / belt , Nut bolts , gaskets etc of 150 HP to 220 Hp motor including necessary arrangements complete all as specifed and directed. Note : Quoted rate is deemed to be inclusive of all arrangements required for replacement of Coupling
Supply and replace coupling rubber / belt of 10 HP to 40 Hp motor including necessary arrangements complete all as specifed and directed . Note : Quoted rate is deemed to be inclusive of all arrangements required for replacement of Coupling
Material and labour for detachable Coupling cover fo safety of operator fof 180 HP to 220 HP motor madeout of 2 MM thick CRCA sheet duly painted og length 1.1 m and width 30 CM including necessary arrangeme for fixing at Base frame by using Nut and Bolts . Note : Quoted rate is deemed to be inclusive of all arrangements required for fixing the protection cover
Supply and replace Unserviceable pressure guage stainless steel of pressure range 100 PSI Suitable for 70 LPS Pumps complete including necessary arrangements including supporting pipes complete all as directed Note : Quoted rate is deemed to be inclusive of all arrangements required for replacement of Pressure Guage
M & L for shifting of cetrifugal monoblock Motor of capacity 5 HP to 10 HP to a new location as directed after disconnecting from existing position including making base by using PCC (!:2:4 by using 20 mm gravel of size not less than 1 M X0.75 X0.75 M and base by using C Channel of suitable size and making electric and water connection complete all as specified and directed. Note : Quoted rate is deemed to be inclusive of all arrangements required for Shifting of Pumpset
Serviceaning / periodical checking of Starter panel board suitable for 180 HP to 220 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Serviceaning / periodical checking of Starter panel board suitable for 15 HP to 40 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Serviceaning / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items.
Servicing of Submersible pump motor set of capacity up to 10 HP complete all as directed
Design, Fabricate, supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system In-door type, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 300 Sqmm 3.5 core in and out , incoming and and copper cable 150 sqmm 6 nos for out going to motors duly marked on revited plates etc complete CPRI approved factory made fabricated out of 2 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement , and all pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs , Panel mounted on suitable MS Chanel frame and grouted in PCC 1:3:6 45 CM including taking down Old LT Panel board of any size after disconnection of all LT UG Cables and stacking carefully at site for re-connection (Location : Gouph Line Pump House) and and consisting the folowing provisions including takingdown old panel :-
(a) Bus bar copper duly insulated with colour coded heat shrinkable sleeves and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 500 Amps for phases and neutral set of 04 for RYB &N - 01 set (c) MCCB 4 Pole 415 Volts 50 Hz 400 Amps, adjustable type of 50 KA repturing capacity - 01 Make: Legrand/Schneider Electric/L&T/SIEMENS/havells
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out in hard/dense soil for removing/laying of pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical DOL starter panel board of size not less than 75cmx75xcmx30cm, 3 Phase 4 wire system indoor type 2mm ,double door front openeing type suitable for wall mounting on top extended , cable alley, provision of knock out type plates for various sizes of cable up to 25Sqmm Sqmm 4 Core in and out, CPRI approved factory made fabricated out of 2.0 mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls , Panel mounted on suitable size of support including taking down old unserviceable and consisting the following provisions:- Make : MCB: L&T/Havells/Siemens. DOL Starter : L&T/BCH or equivalent as approved by GE. Single Phase Preventor: Minilec/GIC or equivalent as approved by GE.
Cleaning, desalting of open well at various locations of AGE E/M No II Sub Station , max dia up to 8 Mtr and max depth upto 15 Mtr (approx) from solid/liquid/mud and vegetation etc by the following procedure: - (a) Dewatering the well with necessary desludge pump for handling heavily contaminated water with solids up to 50 mm and using compressor arrangement incl necessary safety precautions of workers. (b) Repair of head walls, drainage curtain, sanitary seal, cover and lifting mechanisms and removal of vegetation. (c) Empty the contents of the well- water, sludge and debris. (d) Repair damage to the inside of the well and carryout repair to well lining as required at site incl necessary cement and masonry work. (e) Clean the wall of the well using 200mg/l chlorine solution with long handled broom. (f) Disinfect the water in the well with a 50-100 mg/l chlorine dosage (depending on the level of contamination) and leave for a minimum of 30 minutes. (g) Dewater the well and allow it to fully recharge. (h) After recharge chlorine residual in the water, where necessary repeat the process of dewatering and recharge the well until , the chlorine level has reduced to 0.5mg/l or below. (j) Make the final repair to the well cover and water lifting mechanism all as specified and as directed by Engineer-in-Charge. Note : -1. The work shall also include all needed equipment like well dewatering pump of sludge removal upto 50mm, Air compressor , Crane/winch/manual chain pulley, hoist, tripod, electric generator... etc.. 2. Manpower involved in well repair, cleaning and disinfection should be fully trained on the risk and good health and safety practice. The working area should be fenced, a kerb constructed (of there is no head well) and at least 2 m around the well should be kept clear of objects which could fall in.
Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:-
25mm dia bore
40mm dia bore
50mm dia bore
M&L for replacement of existing water level indicator in OHT of any size , capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support, PCC, display board, indicator/pointer, necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed.
M&L for replacement of existing water level indicator in UG Sump of any size, capacity and height by by Float and board types levelGuage using rope, ball valve, pully, necessary support, PCC, display board, indicator/pointer, necessary painting and numbering complete all as required for proper functioning of level indicator complete all as specified and directed.
M&L for painting of water distribution header including all control valves and all exposed pipe of any size by using synthetic enamelled spray painting after scrapping /cleaning complete all as directed at GRPH/MURCURY.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc not exc 10 kg each bracket, conforming to Fe.290, Gde-E-165 in repairs complete all as specified and directed. Note: Item to be used for replacement of base frame of centrifugal / monoblock motor.
Supply Only Water treatment chemical Bio Clean Septic Powder available complete all as specified and directed
Supply only Water treatment chemical sodium hypo Chloride consisting 10 % chlorine content diluted ClNao, complete all as specified and directed. Note : Items to be supplied in 5 liter container)
Supply only Water treatment chemical enzyme-2 (DAP consisting 18:46:0, 18% Nitrogen and water soluble phosphates 46% by minimum weight, packed in 50 Kg Polythene bag complete all as specified and directed. Makes for item Nos 112 to 114 : Akron India Pvt Ltd/Andhra Sugar Pvt Ltd/Aquafit India Pvt Ltd/IIFCO India Ltd/Rayalaseema or equivalent make as approved by GE.
Supply only Activated Carbon Filter media (ACF), Grade IV-900, size of layer 4'(Feet)X2.6'(Feet) as complete all as specified and directed. Make :Granular/Norit or equivalent as approved by GE. Note: ACF Media combination quality & quantity shall be as directed & recommended by OEM only.
Supply only Activated sand Filter media (ASF), size of layer 4'(Feet)X2.6'(Feet) complete all as specified and directed. Note: ASF Media combination quality & quantity shall be as directed & recommended by OEM only. Notes : (a) Daily consumption quantity of each item viz, Chemical Bio Culture Bacteria solution, Sodium Hypochloride etc shall be submitted.Also daily consumption of all chemicals shall be recorded in register and maintained at site. (b) The manufacturer shall comply and guarantee the authenticity of the product by providing Test Certificate with Hologram which will be provided by the Authrorised Distributor at the distribution point for each Batch of Product delivered on their letter head. (c) The manufacturer will affix its hologram on each and every drum/container/bag. If the said product is delivered without the said hologram and/or it is seen to be tampered, then the product can be discarded as spurious.
Material and labour for MBBR fludised bio-media of vergin PPUV stablized material,cylindrical with external fins structure,black colour,22mm dia x 16mm height ,specific gravity 0.9 to 0.95 gms/sqcm all as specififed and as directed . Make: TP Aqua/Cool tech/Hydrotech as approved by GE.
Material and labour Bactria culture for STP for developing MLSS and control odor complete all as directed by Engr-in-Charge. Make: Organic plus or its techno commercial equivalent make as aproved by GE.
M&L for rewinding of the electric motor of above 5Hp upto 10 HP capacity INSTALLED AT FAE STP duly disconnecting (elctric/water connection) and taking down electric motor (mono block/centrifugal) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.
M&L for rewinding of the electric motor of upto 5 HP capacity duly disconnecting INSTALLED AT FAE STP (elctric/water connection) and taking down electric motor (mono block/centrifugal) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.
M&L for rewinding of the electric motor of upto 5 HP capacity duly disconnecting INSTALLED AT FAE STP (elctric/water connection) and taking down electric motor submersible open well type from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical and water line connection system, testing and commissioning complete all as directed.
Opeining of the unserviceable bearing from the centrifugal pump set INSTALLED AT FAE STP replacing the same with the new bearing set sutiable for motor/ pump set 7.5/10HP capacity including re-aliging the pump and motor complete all as directed.
Opeining of the unserviceable bearing from the centrifugal pump set INSTALLED AT FAE STP renewindig the same with the new bearing set sutiable for motor/ pump set 1/2/3/5hp capacity including re-aliging the pump and motor complete all as directed.
Repairs to sewage pump including replacing the impeller upto 5 HP mud pump Kirloskar and unserviceable parts viz bushes, gland cover with nut bolts gland rope etc complete all as directed by Engr-in-Charge.
Repairs to sewage pump including replacing the impeller above 5 upto 10 HP mud pump INSTALLED AT FAE STP of Kirloskar and unserviceable parts viz bushes, gland cover with nut bolts gland rope etc complete all as directed by Engr-in-Charge.
Reconditioning of shaft by metal filling and machining as required and replacement of shaft sleeves with new one of capacity rating up to 5 hp pump set INSTALLED AT FAE STP Note :- Without causing any interruption of regular water supply and complete all as directed by Engineer-in-Charge.
Reconditioning of shaft by metal filling and machining as required and replacement of shaft sleeves with new one of capacity above 5hp up to 10hp pump set INSTALLED AT FAE STP Note :- Without causing any interruption of regular water supply and complete all as directed by Engineer-in-Charge.
Taking out old unserviceable pressure gauge of pump set and supply and fix new pressure gauge INSTALLED AT FAE STP of existing make size including testing and commissioning complete all as directed by Engr-in-Charge.
Taking out old unserviceable and S&F of PPR gate valve (with brass insert) of outer dia of pipe 63mm complete all as specified and directed
Taking out old unserviceable and S&F of PPR gate valve (with brass insert) of outer dia of pipe 50mm complete all as specified and directed
Taking out old unserviceable and S&F of PPR gate valve (with brass insert) of outer dia of pipe 40mm complete all as specified and directed
Taking out old unserviceable and S&F of PPR gate valve (with brass insert) of outer dia of pipe 32mm complete all as specified and directed
Taking out old unserviceable and S&F of PPR gate valve (with brass insert) of outer dia of pipe 25 mm complete all as specified and directed
Taking out old unserviceable and S&F of non return valve flanged end ISI marked suitable for 110mm dia bore including neceesary cutting and marking flange arrangments for fixing complete all as specified and directed. Make: Durga/Kirloskar/Kartar.
Repairs/replacent of wornout spares of Air blower 3-ph,415volts,50hz of capacity 130cum/hr @0.4KSC,twin loop type INSTALLED AT FAE STP including suction filter,motor pully & replacement of unservceable spares such as 'V' belt,bearings, shaft,suction filter,motor pulley & blower motor oil with new one including all nessary misc items for satisafactory completion of job complete all as Specififed & directed by Engr-in-Charge
M&L cleaning the all/any type of tanks(Bar screen chamber/Oil and grease chamber/grit trap chamber/Equalization tank/Aeration tank/Clarifier tank/Anoxic tank/sludge holding tank/traeted water tank etc) pertains to sewage treatment plant 80KLD including receiving sump(collection tank) with suiatble chemeicals, drying the tanks and disposal of Dry sludge minmum distance of 1km raduis from STP location & maintain high level hygiene in STP permises complete all as specified and as directed by Engr-in-Charge. Note: For disposal of dry sludge contactor shall make arrange transport sysytem quoted rate shall be inclusive in unit rate.
Taking out water sample from collection/recieving sump of STP in clean container and getting the same tested from the “any central/state govt approved labs ” for Ph/COD/BOD & other parameters as mentioned in standard proforma of TS pollution control board complete all as directed by Engr-in-Charge. Note: Contractor shall make arrangments for taking out the sample & deemed to be inclusive in quoted rate.
Taking out water sample from treated water sump of STP in clean container and getting the same tested from the “any central/state govt approved labs ” for Ph/COD/BOD & other parameters as mentioned in standard proforma of TS pollution control board complete all as directed by Engr-in-Charge. Note : Contractor shall make arrangments for taking out the sample & deemed to be inclusive in quoted rate.
Mavee Syndicate
sandhya enterprises
Haasith constructions
L and S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .