| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.9 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | 2₹10.2 L+₹33,806 (3.42%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST BIDDER | |
| 3 | Rejected-Technical RIO RANGRAT OLD AIR FIELD ROAD BUDAM KASHMIR PIN 190007 J K | BUDGAM | JAMMU AND KASHMIR | 190007 | - | Rejected-Technical DD not found in order. | |
| 4 | Rejected-Technical SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | - | Rejected-Technical GST copy not uplaoded. | |
| 5 | Rejected-Technical | - | Rejected-Technical DD not found in order. |
| Sl No | Description | Qty | Unit | osho traders L2 | CHHIRPON BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | S& F in repairs for insulation for GI/PP-R pipe of dia from 15 mm to 25 mm with resin bonded fibre glass wool roll and aluminium cladding of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:-
(a)Consist of Natral Foam tube 19 mm,rockwool 50 mm thich, Plastic wrap,Chicken Mesh wire Packing Tape and aluminum Sheet of 28 Gauge.
(b) M&L for cleaning the pipe surface to make the surface completely free of millscale, dirt, dust and other foreign materials, taking special care so that all pipe joints are sealed against any leakage.
(c) M&L for clamping of pipe after insulations by U type clamp and scrws of requred lenth and scerued properly .
Note :- (i) Rates of U type clamps and screws are demade in this quoted rate.
(ii) Rates of Natral Foam tube 19 mm,rockwool 50 mm thich, Plastic wrap,Chicken Mesh wire Packing Tape and aluminum Sheet of 28 Gauge are demade in this quoted rate. | 260 | RM | 1,450 ₹3,77,000 | 1,290 ₹3,35,400 Lowest |
| 2.00 | Taking down old existing PVC water tank of capacity 500/1000 ltrs and installation/fixed on same location after insulatins of any height , testing compleate (Cylindrical, vertical ) including all accessories (i.e GI nipples etc) complete all as specified and directed. | 9 | Each | 120 ₹1,080 | 100 ₹900 Lowest |
| 3.00 | S& F in repairs for water tank insulation of 1000 ltrs capacity, insulated with 50mm thick PUF insulation of density not less than 48 Kg/Cum for PVC tank of capacity 1000 ltrs each complete all as specified anddirected. | 6 | Each Job | 32,000 ₹1,92,000 Lowest | 33,000 ₹1,98,000 |
| 4.00 | S& F in repairs for water tank insulation of 500 ltrs capacity, insulated with 50mm thick PUF insulation of density not less than 48 Kg/Cum for PVC tank of capacity 500 ltrs each complete all as specified anddirected. | 3 | Each Job | 28,000 ₹84,000 Lowest | 28,300 ₹84,900 |
| 5.00 | S& F in repairs ,testing and commissioning self limiting self regulating heat tracer 60-HTS, operated ( heat Cable Elthern ) on 240 Volt AC supply suitable for Gi pipe from 15 mm to 80mm dia complete all as specified and directed. | 280 | RM | 900 ₹2,52,000 Lowest | 940 ₹2,63,200 |
| 6.00 | M&L for replacement of Thermostat for heat Cable Elthern of 0 to 80˚ C complete all as specified and directed. | 9 | Each | 2,100 ₹18,900 | 1,800 ₹16,200 Lowest |
| 7.00Taking up/ down old GI tubing connection including clearing (from trenches) complete as directed by Engr-in-Charge of following sizes :- | |||||
| 7.01 | (a) 20mm bore | 35 | RM | 38 ₹1,330 | 35 ₹1,225 Lowest |
| 7.02 | (b) 25mm bore | 48 | RM | 42 ₹2,016 | 40 ₹1,920 Lowest |
| 8.00S& F in repairs for GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, Washing out complete including dismantling, taking out old corroded pipe complete all as specified and directed for the following sizes:- | |||||
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
12 Nov 2025, 6:35 pmClosed
AGE (I) NIMU
AGE (I) NIMU PIN 901312 C/O 56 APO
REPAIR/REPLACEMENT OF OVER HEAD TANK AND PIPE LINE INSULATION OF UPPER AREA AT NIMU MIL STN UNDER AGE (I) NIMU
2025_MES_736361_1
AGE(I)/NIT-44/2025-26
Open Tender
Miscellaneous Works
Item Rate
270 days
AGE (I) NIMU
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) NIMU
₹20,000
8 Jan 2026
22 Oct 2025
19 Nov 2025
22 Oct 2025
12 Nov 2025
5 Nov 2025
Amount
S& F in repairs for insulation for GI/PP-R pipe of dia from 15 mm to 25 mm with resin bonded fibre glass wool roll and aluminium cladding of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following:- (a)Consist of Natral Foam tube 19 mm,rockwool 50 mm thich, Plastic wrap,Chicken Mesh wire Packing Tape and aluminum Sheet of 28 Gauge. (b) M&L for cleaning the pipe surface to make the surface completely free of millscale, dirt, dust and other foreign materials, taking special care so that all pipe joints are sealed against any leakage. (c) M&L for clamping of pipe after insulations by U type clamp and scrws of requred lenth and scerued properly . Note :- (i) Rates of U type clamps and screws are demade in this quoted rate. (ii) Rates of Natral Foam tube 19 mm,rockwool 50 mm thich, Plastic wrap,Chicken Mesh wire Packing Tape and aluminum Sheet of 28 Gauge are demade in this quoted rate.
Taking down old existing PVC water tank of capacity 500/1000 ltrs and installation/fixed on same location after insulatins of any height , testing compleate (Cylindrical, vertical ) including all accessories (i.e GI nipples etc) complete all as specified and directed.
S& F in repairs for water tank insulation of 1000 ltrs capacity, insulated with 50mm thick PUF insulation of density not less than 48 Kg/Cum for PVC tank of capacity 1000 ltrs each complete all as specified anddirected.
S& F in repairs for water tank insulation of 500 ltrs capacity, insulated with 50mm thick PUF insulation of density not less than 48 Kg/Cum for PVC tank of capacity 500 ltrs each complete all as specified anddirected.
S& F in repairs ,testing and commissioning self limiting self regulating heat tracer 60-HTS, operated ( heat Cable Elthern ) on 240 Volt AC supply suitable for Gi pipe from 15 mm to 80mm dia complete all as specified and directed.
M&L for replacement of Thermostat for heat Cable Elthern of 0 to 80˚ C complete all as specified and directed.
Taking up/ down old GI tubing connection including clearing (from trenches) complete as directed by Engr-in-Charge of following sizes :-
(a) 20mm bore
(b) 25mm bore
S& F in repairs for GI tubing medium grade laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, Washing out complete including dismantling, taking out old corroded pipe complete all as specified and directed for the following sizes:-
(a) 20mm bore
(b) 25mm bore
Taking up/ down old PP-R tubing connection including clearing (from trenches) complete as directed by Engr-in-Charge of following sizes :-
(a) PP-R pipe 20 mm bore
(b) PP-R pipe 25 mm bore
S& F in repairs of 3- Layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as specified and directed by Engr-in-charge.
(a) PP-R pipe 20 mm bore
(b) PP-R pipe 25 mm bore
Taking down old unserviceable gate valve/ ball valve of any size type.
S& F in repairs PP-R ball valves(brass insert) for 25 mm dia pipe as per requirement of the site all as specified and directed .
S& F in repairs PP-R ball valves(brass insert) for 20 mm dia pipe as per requirement of the site all as specified and directed .
S& F in repairs for Gun metal or Bronze globe / ball valve, ISI Marked, screwed both ends suitable for GI tubing with side way operating GI lever handle including taking down old u/s valve of any type / make complete all as specified and directed for the following sizes:-
Taking Down old Unserviceable DBs with MCB of any capacity all as specified and as directed by Engineer-in-Charge.
S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 04 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as specified and directed.
M&L in repair for MCB SPN 32 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
S&F in repairs to MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Taking down carefully circuit/ submain wiring for any description including DBs complete and all as specified and as directed by Engineer-in-Charge.
Supply and laying in replacement of existing circuit/submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws and including single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 4 sq mm as earth wire complete all as specified & directed.
osho traders (BID ID -3477184)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_824499.xls
BOQ • 0.36 MB
Tender44.pdf
Tender Documents • 2.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .