Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹49.3 L+₹3.1 L (6.62%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹60.3 L+₹14.0 L (30.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
27 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
Garrison Engineer NW Kunjali Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 400005
8346 REPAIR MAINTENANCE OF LT DISTRIBUTION NETWORK INCLUDING FEEDER PILLARS LT CABLES LT SWITCHGEARS AND COPE POINTS AT NAVAL DOCKYARD UNDER GE NW KUNJALI
2021_MES_416921_2
8346/E8
Open Tender
Civil Works
Item Rate
186 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
20 Mar 2021
5 Feb 2021
1 Mar 2021
9 Feb 2021
27 Feb 2021
13 Feb 2021
5 Feb 2021 - 9 Feb 2021
60 days
Amount
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 1000 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at MWC including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 630Amps 4pole,36 KA,Thermal magnetic - 2 Nos (Incomer) ii) Autochangeover 630 amps 4 pole OUTGOING i) MCCB, 4 pole 200 Amps,25KA,Thermal magnetic - 2Nos (Out going) ii) MCCB, 4 pole 100 Amps,18KA,Thermal magnetic - 3Nos (Out going) iii) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 5 Nos (Out going) iv) VAF meter class 1with CT's - 1 No v) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 630 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at TPW (NAD) including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 400Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 10 Nos (Out going) ii) VAF meter class 1with CT's - 1 No iii) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 1600 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at NAD AC PLANT including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) ACB 1000 Amps 4pole,50 KA,drawnout type - 2 Nos (Incomer) ii) On load changeover 1600 amps 4 pole open execution OUTGOING i)MCCB, 4 pole 400 Amps,25KA,Thermal magnetic - 1Nos (Out going) ii) MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 2Nos (Out going) iii) MCCB, 4 pole 100 Amps,18KA,Thermal magnetic - 5Nos (Out going) iv) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 1 Nos (Out going) v) VAF meter class 1with CT's - 1 No vi) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 1000 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at FMU First Floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 630Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i) MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 2Nos (Out going) ii) MCCB, 4 pole 100 Amps,18KA,Thermal magnetic - 1Nos (Out going) iii) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 4 Nos (Out going) iv) VAF meter class 1with CT's - 1 No v) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 630 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at FTTT First floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 400Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 10 Nos (Out going) ii) VAF meter class 1with CT's - 1 No iii) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 630 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at FTTT First floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 400Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i)MCCB, 4 pole 200 Amps,25KA,Thermal magnetic - 1 Nos (Out going) ii)MCCB, 4 pole 100 Amps,16KA,Thermal magnetic - 3 Nos (Out going) iii) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 2 Nos (Out going) iv) VAF meter class 1with CT's - 1 No v) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 800 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at WRSTG Second floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 500Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i)MCCB, 4 pole 100 Amps,16KA,Thermal magnetic - 4 Nos (Out going) ii) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 4 Nos (Out going) iii) VAF meter class 1with CT's - 1 No iv) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 800 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at MTU Second floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 500Amps 4pole,36 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i)MCCB, 4 pole 100 Amps,16KA,Thermal magnetic - 4 Nos (Out going) ii) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 4 Nos (Out going) iii) VAF meter class 1with CT's - 1 No iv) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 800 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at FSTC Top floor including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) MCCB 250Amps 4pole,25 KA,Thermal magnetic - 1 Nos (Incomer) OUTGOING i) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 4 Nos (Out going) ii) Three phase 4 wire meter - 02 nos. iii) VAF meter class 1with CT's - 1 No iv) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having vertical Copper bus bar of capacity 1600 amps for phases and for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at C-28 MAIN Panel including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- INCOMER i) ACB 1000 Amps 4pole,50 KA,drawnout type - 2 Nos (Incomer) ii) On load changeover 1600 amps 4 pole open execution OUTGOING i)MCCB, 4 pole 400 Amps,25KA,Thermal magnetic - 1Nos (Out going) ii) MCCB, 4 pole 250 Amps,25KA,Thermal magnetic - 2Nos (Out going) iii) MCCB, 4 pole 100 Amps,18KA,Thermal magnetic - 5Nos (Out going) iv) MCCB, 4 pole 63 Amps,16KA,Thermal magnetic - 1 Nos (Out going) v) VAF meter class 1with CT's - 1 No vi) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/ Legrand/Seimens/L & T
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables , in door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 2500 amps for phases and for neutral including powder coated painting, PCC foundation, supporting channels,cable termination,cable gland etc complete at jetty/casin including taking down old panel all as directed.
Supply, fabrication, installation, testing & commissioning of Feeder piller box for looping of cables, in door type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having vertical copper bus bar of capacity 800 amps for phases and for neutral including 400Amps, 4 pole, 36 KA AC/DC MCCB powder coated painting, PCC foundation, supporting channels,cable termination, cable gland etc complete at jetty/casin including taking down old panel all as directed.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting TPN 8 way, 440 volts with copper bus bar rating 100 Amps for each phase with 2 neutral bar, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make - Legrand cat part no 5077 82 or equivalent in Siemens /GE/ C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 41 or equivalent in Siemens /GE/ C&S
S & F MCCB, 415 volts, Four pole, 125 Amps capacity, 16 KA, ICS = 100% ICU, with fixed Thermal- Magnetic setting including spreader terminal/ thimble of suitable size and making connections and taking down the existing unsrviceable MCCB from the panel complete all as directed. Make - Legrand cat No 4200 16 or equivalent in siemens/GE/ C&S
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make - Legrand cat No 4085 87-95 or equivalent in Siemens /GE/ C&S
S & F in replacement of MCB, SPN 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make - Legrand cat No 4086 20 or equivalent in Siemens /GE/ C&S
S & F in replacement of MCB, SPN 40 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make - Legrand cat No 4086 18 or equivalent in Siemens /GE/ C&S
S&F in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed.
S &F in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCPL-36-CDL(2X2) / C&S cat No LTCRSLM36WATT2X2 or equivalent Cat part in Surya / Philips
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3.5 cre complete all as specified and directed. Make : Rychem/3M
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3.5 cre complete all as specified and directed. Make :Rychem/3M
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3.5 core complete all as specified and directed. Make :Rychem/3M
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as specified and directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil compete all as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm compete all as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point compete all as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
Supply and layingreinforceced precast concrete cable cover, class LV type , I, flat size 250mmx150mmx40mm laid across the cable complete all as specified and directed.
M&L for GI pipe light grade 100mm dia for protection of UG cable crossing of nalha/bgrdge/road etc complete all as directed.
M&L cement concrete in 1:2:4 type B1 using 20mm grade stone aggregate for road cutting/pole couping exposed surfaced and fair and even finishing with out using any extra cement etc complete all as specified and directed
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 185sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S&F in repair of double door type vertical type TPN DB 6 Way ,240V with 100A copper busbar , double door type IK 09 protection suitable for housing MCCB's all as specified and directed by EIC.Make: Legrand cat No 507781/Seimens/C&S. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note - Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
S&F galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed.
Shree Ayyappa Engineering
ELECTRO ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .