Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.6 LAccepted-AOC | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹22.4 L+₹3.9 L (20.7%)Rejected-AOC | L-2 | Rejected-AOC Not Lowest |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
11 Aug 2022, 6:00 pmClosed
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
PROVISION OF 01 X TOILET BLOCK AT NO 1 TRG BN (AT) OF ASC CENTRE (NORTH)-1 ATC UNDER GE (CENTRAL) BANGALORE
2022_MES_519237_3
86121/E8
Open Tender
Construction Works
Item Rate
180 days
BANGALORE
ENLISTMENT CLASS E and Category a (i) or b (i). Other details as per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (CENTRAL) BANGALORE
₹38,000
Yes
HQ CWE ARMY BANGALORE
17 Sept 2022
6 Jul 2022
13 Aug 2022
6 Jul 2022
11 Aug 2022
21 Jul 2022
6 Jul 2022 - 13 Jul 2022
14 Jul 2022
Amount
Excavation in trenches not exc 1.5mtr deep and not exc 1.5mtr wide for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as directed.
Earth filling under floor spreading and levelling in layers n.exc 25 cm thick incl well ramming and watering as required complete all as directed.
Returning, filling in soil including ramming, consolidating etc of each layer n.exc 25cm thick complete all as directed.
Removing excavated meterial to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as directed.
Hardcore of broken stone or boulders of gauge n. exc. 63 mm deposited, spread and levelled in layers N. exc. 15 cm thick watered and rammed to a true surface complete all as directed.
75 mm thick plain cement concrete, (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base of floors complete all as directed.
PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as directed.
25mm thick PCC 1:2:4 type BO (using 12.50mm graded stone aggregate) as in floors finishing complete all as directed.
75mm thick, PCC 1:3:6 type CI (using 20mm graded stone aggregate), finished even and smooth without using extra cement as in plinth protection incl joints filling complete all as directed.
RCC M-25 design mix as in foundation, incl rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete complete all as directed.
RCC M25 Design mix as in columns, pillars, piers, post and struts complete all as directed
RCC M25 Design mix as in beams, cantilevers, bressumers, lintal over 1.5 M span complete all as directed
RCC M-25 Design Mix in slab supported on walls, beams and columns in floors roofs landings balconies canoipes, deck slabs and in shelves complete all as directed.
RCC M-25 Design Mix as in chajjas, complete all as directed.
Form work to sides of flat concrete foundatins, footings, based of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as directed.
Form work to sides of pillars, posts, struts, piers columns complete all as directed.
Form work to sides and soffits of floor or roof beam, beam haunching, girders bressumers, lintels cantilevers shelves incl supports, overhangs etc also spalys between floors and beams etc complete all as directed.
Form work to chullah hoods, chajjas and similar items incl edges complete all as directed.
Form work to soffits of suspended slab such as roof slabs floor slabs etc including fair finished surfaces complete all as directed.
Form work to edges of concrete flat, traeads, breaks in floor window cills concrete railing exc 10cm but n.exc 20cm wide rough finished surfaces of concrete complete all as directed.
TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending etc and securing with including Mild steel wire (annealed) not less than 0.9mm dia complete all as directed.
TMT bars 6 to 8 mm dia and over for roof slab, cut to length, bent to shape required, including cranking, bending etc and securing with including mild steel wire (annealed) not less than 0.9mm dia complete all as directed.
TMT bars 5mm dia and over upto 10mm as in stirrups,cut to length, bent to shape required, including cranking, bending etc and securing with including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as directed.
M & L for ATT treatment to the top surface of filled earth at the rate of 5 litres of emulsion per sqm of surface complete all as directed.
M & L for ATT treatment to the soil under plinth protection at the rate of 5 litres of emulsion per sqm of surface complete all as directed.
M & L for ATT treatment to the soil alongwith external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as directed.
Precast cement block masonry with solid blocks type C-1 1:3:6 20mm graded aggregate ,exc 10cm in width and setting in mortar 1:6 complete all as directed.
Precast cement block masonry with solid blocks grade C-5 n,exc 10cm in width and setting in mortar 1:6 complete all as directed.
Rendering 10mm thick in cement mortor 1:6 on fair faces of brick or concrete block masonry surfaces including finished even and smooth without using extra cement on internal surfaces of wall complete all as directed.
Rendering 15mm thick on fair faces of brick works or concrete surface in cement mortor 1:4 (in two layers 5mm thick setting coat mixed with WPC as per manufacturer instrction over 10 mm thick backing coat) including finished even and smooth, without using extra cement complete all as directed. Note:- WPC will be measure and paid saperately
Rendering 5mm thick in CM 1:3 finished even and smooth without using extra cement as in ceiling complete all as directed
Supply only water profing compound complete all as directed.
Preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as directed.
Preparation of new plastered surfaces of wall and applying two coats of apex weather coat incl priming coat of exterior primer complete all as directed.
M&L Non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15 mm thick screed bed in CM 1:6 complete all as directed.
Glazed ceramic coloured tiles 350x250x7mm/ 450x350x7mm thick on vertical surfaces such as dados and risers to step etc, set and jointed in neat cement slurry and pointed in coloured cement to match the tiles including 10mm thick rendering in CM 1:4 complete all as directed.
Factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed to wall complete all as directed.
Factory made solid PVC moulded door shutter , 30mm thick (stiles) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for tip rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame wedded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing complete all as directed.
Butt hinges MS 100 mm, medium weight, cold rolled complete all as directed
Aluminium handle 150 mm cast type anodized complete all as directed.
Aluminium anodized tower bolt 150 mm size complete all as directed.
S&F 300mm aluminium alloy, anodized, sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as directed.
Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layer, hoisted and fixed in position all as specified in SSR part- I capacity of tank 1000 ltrs complete all as directed.
Vitreous China squatting pan, ‘Orissa’ pattern,WC of size 580 x 440 mm white, with integral foot rests, trap, flush pipe including connection to trap and flushing pipe, antisyphonage pipe etc. complete all as directed.
Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; supply and fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as directed.
PVC flushing cistern low level of 10 liter capacity white with inlet ball valve float and handle including bracket. PVC connections 15 mm size with PTMT nut of length 450 mm etc. complete all as directed (Make Slimline / Commander / Hindware)
Vitreous china wash hand basin white flat back size 550x400mm including chromium plated fancy type long neck pillar tap capstain head suitable for 15mm bore of pipe, CI bracket. CP waste coupling and PVC waste pipe 75 cm long and 15mm dia and 450mm long PVC connection pipe complete all as directed.
Looking mirror 600x450mm beveled edge with PVC sheet frame and back supported with 6mm thick AC building board or plywood sheet complete all as directed.
PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as directed
S/ F 20 mm bore ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule and fixed for following bore of pipe including taking out old unserviceable float valves complete all as directed.
M&L for Applying oil bound bitumen primer @ 1.50 Kg/Sqm and providing 3 mm thick APP modified water proofing membrane weighing 3.0 kg/sqm reinforced with non woven polyester matt weighing not less than 150 gm /sqm having softening point not less than 140 centigrate, having tensile strength of 650N/sqm and 350 N/sqm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /Sqm top of membrane surface shall then be finished with solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm including taking down existing roof treatment and removing from MD land all as directed. (WPC measured and paid seprately) complete all as directed.
S&F Box type Steel Windows/Ventilators double side shutters (Windows side hung type , Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet of 40x20x1.0mm , windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose . (Note : All Windows/Vent design as per CECZ TD drg No 539)
4.0 mm thick figured glass pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples complete all as directed.
M&L for preparation of new steel surface over 10cm with or girth. applying two coats of synthetic enemal paint over a coat of red oxide primer including complete all as directed.
110 mm bore PVC SWR pipe single socketed in any length with rubber ring joint laid in trenches or floor complete all as directed.
75 mm bore PVC SWR pipe single socketed in any length with rubber ring joint laid in trenches or floor complete all as directed.
PVC (SWR) floor trap 75 mm dia with grating including joint with solvent cement complete all as directed.
S&F PVC (SWR) bends 110mm dia any radius with access door complete all as directed.
S&F PVC (SWR) bends 75 mm dia any radius with access door complete all as directed.
S&F PVC (SWR) junction single,(Single T) 110mm dia equal or unequal with access door complete all as directed.
S&F PVC (SWR) junction single,(Single T) 75mm dia equal or unequal with access door complete all as directed.
S&F PVC (SWR)vent cowl 110/75mm bore complete all as directed.
S&F in Repair Chromium Plated Steel Grating of 100mm size With or Without Waste Hole complete all as directed.
S&F 16 mm outer dia CPVC Pipe (ISI Marked) SDR 11 & plain CPVC SDR 11 fittings fixed on wall, celing or floors complete all as directed..
S&F 20m outer dia CPVC Pipe (ISI Marked) SDR 11 & plain CPVC SDR 11 fittings fixed on wall, celing or floors complete all as directed.
25mm medium grade galvanised iron pipe with all fitting and fixed to walls and ceilings or laid in floors complete all as directed.
15mm bore stop valves fancy type chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as directed.
15mm bore fancy type Bib taps cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as directed.
15mm bore pillar taps cast copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lattered 'Hot' or 'Cold' with long screwed for iron pipe and fixed complete all as directed.
M & L for reinforced concrete pipes 150mm dia class NP3 laid and jointed with collars complete all as directed.
PCC 1:4:8 type D-2, (using 40mm graded stone aggregate) as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as directed
Removing excavated surplus material to a distance exc 250m but n exc 500m and depositing where directed at a level not exc 1.5 above the starting point complete all as directed.
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in benching, haunching of man holes, coping, including necessary form work and finished exposed surface of concrete all as specified in Para 4.11.16 of SSR Part I.
Providing pre cast reinforced concrete type B-1, 1:2:4 mix (using 20 mm graded stone aggregate) for man holes cover slab, set in CM 1:4 including necessary form work. Note:- Reinforcement steel shall be measured and paid separatly)
TMT bars 6 to 8 mm dia and over for cover slab, cut to length, bent to shape required, including cranking, bending etc and securing with including mild steel wire (annealed) not less than 0.9mm dia complete all as directed.
Rendering 15mm thick on fair faces of brick works or concrete surface in cement mortor 1:4 including finished even and smooth, without using extra cement complete all as directed. Note:- WPC will be measure and paid saperately
Septic tanks, excavation in any type of soil, foundation In PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc., complete for 150 users. (Drg No CECZ TD-556 Sheet No 1/3 to 3/3)
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth. (Drg No CECZ TD/57/746 Sheet No 1/1)
Extra for forming fair finished to channel or drain 30 cm inner girth in cement concrete using extra cement including mitred/stopped ends, forms moulds etc; complete all as directed.
Surface excavation n exc. 30 cm Depth and average 15 cm deep in soft/loose soil complete all as directed.
M&L for hard core using broken/crushed stone aggregate of guage not exc 63mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surfaces complete all as directed.
M&L 75 mm thick cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate), as in sub base of floors complete all as directed.
Sand filling under floors or in foundation incl watering and consolidation complete all as directed.
M & L machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS15658-2006 of 60mm thickness M-35 grade complete all as directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as in parabolic semi -segment benching, roof Kerbs ,coping ,bed plate & similar work, complete all as directed.
Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic grey conduit on surface conforming to IS-9537 with all accessories including PVC/MS terminal boxes fixed on wall with 3mm thick masonite laminated sheet top cover fixed with steel screws for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor as earth continuity conductor to common earth and connecting to earth dolly all as specified for :-
(a) One lightpoint /fan point controlled for one switch complete all as directed.
Switch piano, flush button single pole 6 Amps one way complete all as directed.
Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC square blocks complete all as directed
Supply and fixing exhaust fan, heavy duty single phase 230 volts AC of 300mm sweep with louvers and connecting up with provision of porociline connector and flexible three core copper conductor of 0.5 sqmm size from terminal point complete all as directed by Engineer-in-Charge.
S&F in replacement LED tube light fitting of 20 watts 6000K,230 volts, with long lasting aluminium body with slim & sleek looks all pre-wired fixed on walls/ ceiling with all fixing accessories such as 2 Nos of PVC square/ round boxes, screws etc and connecting up with three core flexible copper conductor cable size 24/0.20 sqmm complete all as durected by Engineer-in-Charge.
S&F in replacement LED tube light fitting of 10/09 watts ,230 volts, with long lasting aluminium body with slim & sleek looks all pre-wired fixed on walls/ ceiling with all fixing accessories such as 2 Nos of PVC square/ round boxes, screws etc and connecting up with three core flexible copper conductor cable size 24/0.20 sqmm complete all as durected by Engineer-in-Charge.
Supply & Fix DB 2way without Bus bar complete all as directed
MCB Singlepole & neutral 5Amps 240 volts, 10 KA rupturing capacity providing in DB complete all as directed.
S&F OF 01 x 40 watts, 230 volts, Endura Pearl Neo, New generation energy saving and environment friendly long lefe LED Bldg security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as directed by Engineer-in-Charge
M & L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level conneting with steel GI earth wire 4mm dia by means of bolt nut olts,nuts,check nuts and washers including PCC pit with 1:2:4 type B-1 using 20mm graded stone aggregate and frame cover of angle iron 25x25x6mm, MS sheet 3mm thick, and handle of 6mm dia MS bar made to shape , GI medium grade 20mm bore pipe for watering comman salt charcoal funnel wiremesh, eartwork in any type of soil returning filling in and removal of soft/loose soil to a distance n.exc 5 mtr including earth test point and making connections, testing on completion all as per electric plate No 5 of SSR Part-I and all as directed by Engineer-in-Charge at site.
Chandana Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .