Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.0 Cr | L1 | Accepted-AOC Bidder is L1 |
| 2 | L2₹1.1 Cr+₹5.2 L (4.99%)Rejected-AOC | ₹1.1 Cr+₹5.2 L (4.99%) | L2 | Rejected-AOC Bidder is L2 |
| 3 | L3₹1.1 Cr+₹8.1 L (7.71%)Rejected-AOC | ₹1.1 Cr+₹8.1 L (7.71%) | L3 | Rejected-AOC Bidder is L3 |
| 4 | L4₹1.1 Cr+₹8.1 L (7.72%)Rejected-AOC | ₹1.1 Cr+₹8.1 L (7.72%) | L4 | Rejected-AOC Bidder is L4 |
| 5 | L5₹1.1 Cr+₹8.2 L (7.81%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.1 Cr+₹8.2 L (7.81%) | L5 | Rejected-AOC Bidder is L5 |
| Sl No | Description | Qty | Unit | R. P. Suppliers and Construction Co. L3 | KULBHUSHAN AGGARWAL L7 | JAI DURGA CONSTRUCTION CO L4 | kailu construction co L5 | R D Bansal L1 | BHARAT ENGINEERS L2 | CHOUDHARY AND SONS L6 | Standard engineers L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface, complete, all as directed | 34 | Each | 50 ₹1,700 Lowest | 200 ₹6,800 | 100 ₹3,400 | 100 ₹3,400 | 200 ₹6,800 | 50 ₹1,700 Lowest | 500 ₹17,000 | 202 ₹6,868 |
| 2.00 | Dismantling of existing old ACSR conductors, any size, from existing LT poles at area where UG cables are to be laid, by unwinding the binding wire from insulators including disconnecting from the existing system, keep in safe custody for reuse, complete all as specified and directed by Engr-in-Charge. | 12 | Qtl | 50 ₹600 Lowest | 500 ₹6,000 | 100 ₹1,200 | 100 ₹1,200 | 100 ₹1,200 | 100 ₹1,200 | 3,300 ₹39,600 | 502 ₹6,024 |
| 3.00 | Dismantling of existing old cross arms etc made of mild steel channel, angle iron, flat iron, back plates, nuts, bolts, washers etc complete all as directed . | 2 | Qtl | 50 ₹100 Lowest | 500 ₹1,000 | 100 ₹200 | 100 ₹200 | 100 ₹200 | 100 ₹200 | 400 ₹800 | 502 ₹1,004 |
| 4.00 | Dismantling/taking down of insulators of any type/size from LT poles complete all as directed. | 400 | Each | 1 ₹400 Lowest | 5 ₹2,000 | 5 ₹2,000 | 1 ₹400 Lowest | 1 ₹400 Lowest | 2 ₹800 | 10 ₹4,000 | 2 ₹800 |
| 5.00 | Dismantling of existing old earth wire/guard wire service feeder or distributor span complete all as directed. | 2 | Qtl | 200 ₹400 | 500 ₹1,000 | 100 ₹200 | 100 ₹200 | 100 ₹200 | 50 ₹100 Lowest | 500 ₹1,000 | 502 ₹1,004 |
| 6.00 | Supply, fabrication, installation, testing & commissioning of factory made LT panel, outdoor type, CPRI approved, double door, totally enclosed, weather and vermin proof, suitably ventilated, 415 Volts, 50 cycles, AC supply, fully compart mentalized, made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support, required civil works, excavation & earth work, PCC foundation etc, complete, all as specified & directed with including the following :-
(a) Aluminium bus bar of capacity 1200 Amps for phase and 600 Amps for Neutral.
(b) Ammeter 0 to 800 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
(c) Voltmeter 0 to 500 volts digital type
Incoming : (i) MCCB TPN 630 Amps, 36 KA 415 Volts 4 pole (Adjustable )- 01 No
Outgoing : (i) MCCB 4 pole 320 Amps 35 KA 415 Volts (adjustable ) - 02 No .
(ii) MCCB 4 pole 250 Amps 16 KA 415 Volts (adjustable ) - 02 No
(iii) MCCB 4 pole125 Amps 16 KA, 415 Volts (adjustable )- 02 No
(Iv) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current capacity 16 Amps. | 4 | Each | 1,90,000 ₹7,60,000 Lowest | 2,10,000 ₹8,40,000 | 2,20,000 ₹8,80,000 | 1,95,000 ₹7,80,000 | 1,93,000 ₹7,72,000 | 1,98,650 ₹7,94,600 | 2,10,000 ₹8,40,000 | 2,10,009 ₹8,40,036 |
| 7.00 | Supply, fabrication, installation, testing & commissioning of factory made LT panel, outdoor type, CPRI approved, double door, totally enclosed, weather and vermin proof, suitably ventilated, 415 Volts, 50 cycles, AC supply, fully compart mentalized, made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support, required civil works, excavation & earth work, PCC foundation etc, complete, all as specified & directed with including the following :- -
(a) Aluminium bus bar of capacity 800 Amps for phase and 400 Amps for Neutral.
(b) Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
(c) Voltmeter 0 to 500 volts digital type
Incoming : (i) MCCB, TPN, 400 Amps, 36 KA, 415 Volts 4 pole (Adjustable)- 01 No
Outgoing : (i) MCCB, 4 pole, 250 Amps, 36 KA, 415 Volts (adjustable ) - 01 No .
(ii) MCCB, 4 pole, 125 Amps, 16 KA ,415 Volts (adjustable) - 02 No
(iii) MCCB, 4 pole ,100 Amps, 16 KA, 415 Volts (adjustable )- 02 No
(iv) MCB, TPN, 63 Amps - 02 Nos
(Iv) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current capacity 16 Amps. | 6 | Each | 1,45,000 ₹8,70,000 | 1,40,000 ₹8,40,000 | 1,45,000 ₹8,70,000 | 1,33,000 ₹7,98,000 | 1,19,000 ₹7,14,000 Lowest | 1,35,500 ₹8,13,000 | 1,40,000 ₹8,40,000 | 1,40,009 ₹8,40,054 |
| 8.00 | Supply, fabrication, installation, testing & commissioning of factory made LT panel, outdoor type, CPRI approved, double door, totally enclosed, weather and vermin proof, suitably ventilated, 415 Volts, 50 cycles, AC supply, fully compart mentalized, made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support, required civil works, excavation & earth work, PCC foundation etc, complete, all as specified & directed with including the following :-
(a) Aluminium bus bar of capacity 300 Amps for phase and 200 Amps for Neutral.
(b) Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
(c) Voltmeter 0 to 500 volts digital type
Incoming : (i) MCCB, FP, 250 Amps, 36 KA, 415 Volts 4 pole (Adjustable )- 01 No
Outgoing : (i) MCCB, FP, 200 Amps, 36 KA, 415 Volts (adjustable ) - 01 No .
(ii) MCCB, FP,125 Amps, 16 KA, 415 Volts (adjustable )- 02 No
(III) MCB, TPN,63 Amps, 16 KA - 02 Nos
(Iv) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current capacity 16 Amps. | 8 | Each | 90,000 ₹7,20,000 Lowest | 1,00,000 ₹8,00,000 | 1,10,000 ₹8,80,000 | 93,000 ₹7,44,000 | 94,000 ₹7,52,000 | 1,04,990 ₹8,39,920 | 1,15,000 ₹9,20,000 | 1,00,009 ₹8,00,072 |
| 9.00 | Supply, fabrication, installation, testing & commissioning of factory made LT panel, outdoor type, CPRI approved, double door, totally enclosed, weather and vermin proof, suitably ventilated, 415 Volts, 50 cycles, AC supply, fully compart mentalized, made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support, required civil works, excavation & earth work, PCC foundation etc, complete, all as specified & directed with including the following :-
(a) Aluminium bus bar of capacity 200 Amps for phase and 100 Amps for Neutral.
(b) Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
(c) Voltmeter 0 to 500 volts digital type
Incoming : (i) MCCB, 4P, 125 Amps, 16 KA 415 Volts 4 pole (Adjustable )- 01 No
Outgoing : (i) MCCB, 4 pole, 100 Amps, 16 KA, 415 Volts (adjustable ) - 02 No .
(ii) MCCB, 4 pole, 63 Amps, 16 KA, 415 Volts (adjustable )- 02 No
(III) MCB, TPN 63 Amps - 02 Nos
(Iv) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder current capacity 16 Amps | 8 | Each | 85,000 ₹6,80,000 | 79,500 ₹6,36,000 | 80,000 ₹6,40,000 | 70,000 ₹5,60,000 Lowest | 85,000 ₹6,80,000 | 81,000 ₹6,48,000 | 85,000 ₹6,80,000 | 79,509 ₹6,36,072 |
| 10.00 | Supply, fabrication, installation, testing and commissioning, CPRI approved manufacturer, LT Junction Box, out door, cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 60mm x 60mm x 40 mm with front side hinged door, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal & external surface) with heat shrinkable sleeves on AIuminim bus bar 500 Amp capacity - 04 Nos providing holes (not less than ten nos of 3Ph distributions) for the connection of outgoing cables, complete wiring with thimbles and other accessories using crimping tool including fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation including taking down existing old unserviceable LT Junction Box , complete all specified and directed comprising the following :-
(i) MCCB 4 pole, 415 volts of Capacity 250 Amps - 01 No.
(ii) Indicating lamps, LED type, 230 V AC - 03 Nos.
(iii) Digital Voltmeter, 3 Phase - 01 No.
(iv) Digital Ammeter 3 Phase - 01 No.
(v) CT coils -03 Nos. | 8 | Each | 35,000 ₹2,80,000 | 41,000 ₹3,28,000 | 35,000 ₹2,80,000 | 37,000 ₹2,96,000 | 35,500 ₹2,84,000 | 34,800 ₹2,78,400 Lowest | 37,000 ₹2,96,000 | 41,009 ₹3,28,072 |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
22 Jul 2025, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Jalandhar Cantt PIN 144005
Upgradation of electric infrastructure at MIL station Beas
2025_MES_709987_1
8325/16/E8
Open Tender
Civil Works
Item Rate
180 days
HQ CWE Jalandhar Cantt
Class B Category b(i) for contractors enlisted with MES
9 documents required · 9 mandatory
₹1,000
Yes
GE Kapurthala
₹2.1 L
Yes
12 Sept 2025
24 Jun 2025
25 Jul 2025
24 Jun 2025
22 Jul 2025
16 Jul 2025
Amount
Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface, complete, all as directed
Dismantling of existing old ACSR conductors, any size, from existing LT poles at area where UG cables are to be laid, by unwinding the binding wire from insulators including disconnecting from the existing system, keep in safe custody for reuse, complete all as specified and directed by Engr-in-Charge.
Dismantling of existing old cross arms etc made of mild steel channel, angle iron, flat iron, back plates, nuts, bolts, washers etc complete all as directed .
Dismantling/taking down of insulators of any type/size from LT poles complete all as directed.
Dismantling of existing old earth wire/guard wire service feeder or distributor span complete all as directed.
Supply, fabrication, installation, testing and commissioning, CPRI approved manufacturer, LT Junction Box, out door, cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 60mm x 60mm x 40 mm with front side hinged door, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal & external surface) with heat shrinkable sleeves on AIuminim bus bar 500 Amp capacity - 04 Nos providing holes (not less than ten nos of 3Ph distributions) for the connection of outgoing cables, complete wiring with thimbles and other accessories using crimping tool including fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation including taking down existing old unserviceable LT Junction Box , complete all specified and directed comprising the following :- (i) MCCB 4 pole, 415 volts of Capacity 250 Amps - 01 No. (ii) Indicating lamps, LED type, 230 V AC - 03 Nos. (iii) Digital Voltmeter, 3 Phase - 01 No. (iv) Digital Ammeter 3 Phase - 01 No. (v) CT coils -03 Nos.
S&F in replacement of factory made powder coated Vertical DBs, TPN ,440 V, 4 Way, in double door suitable for flush mounting and surface mounting with 250 A copper busbar for each phase with 2 neutral bar, 2 earth bar and cable ties for cable management and fully insulated busbar and shrouded neutral bars with MCCB as Incomer and SP, 6 to 32 Amps and 40 to 63 Amps for out going total 16 Nos including taking down old UNSV DBs complete all as specified and directed.
S&F in replacement of factory made powder coated Vertical DBs, TPN ,440 V,6 Way, in double door suitable for flush mounting and surface mounting with 250 A copper busbar for each phase with 2 neutral bar,2 earthbar and cable ties for cable management and fully insulated busbar and shrouded neutral bars with MCCB 250 Amp, 16 KA as Incomer and SP 6 to 32 Amps and 40 to 63 Amps total 16 Nos for out going including taking down old UNSV DBs, complete all as specified and directed.
Supply, Laying, jointing and testing XLPE insulated, screened & PVC bedded, galavised steel strip or wire armoured, LT cable, 1100 volts grade (heavy duty ) with stranded aluminium conductor, cross sectional area 10 Sqmm, 2 core fixed along the poles or passing through pipes or laid under floors or through walls, laid in trenches, complete all as specified & directed. Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
All as per description of serial item No.13 here in before but cross sectional area 16 Sqmm, 2 core .
All as per description of serial item No.13 here in before but cross sectional area 16 Sqmm, 4 core complete all specified.
All as per description of serial item No.13 here in before but cross sectional area 25 Sqmm, 2 core complete all specified.
All as per description of serial item no.13 here in before but cross sectional area 35 Sqmm, 3½ core complete all specified.
All as per description of serial item no.13 here in before but cross sectional area 50 Sqmm 3½ core complete all specified.
All as per description of serial item No. 13 here in before but cross sectional area 70 Sqmm 3½ core .
All as per description of serial item No. 13 here in before but cross sectional area 95 Sqmm 3½ core.
All as per description of serial item No. 13 here in before but cross sectional area 120 Sqmm 3½ core.
All as per description of serial item No. 13 here in before but cross sectional area 150 Sqmm 3½ core.
All as per description of serial item No. 13 here in before but cross sectional area 185 Sqmm 3½ core.
All as per description of serial item No. 13 here in before but cross sectional area 240 Sqmm 3½ core .
All as per description of serial item No. 13 here in before but cross sectional area 300 Sqmm 3½ core.
Supply and fixing in replacement for GI protection pipe light grade for cable protection incl all fittings laid in trenches or fixed on pole all as specified for 50mm dia
Supply and fixing in replacement for GI protection pipe light grade for cable protection incl all fittings laid in trenches or fixed on pole all as specified for 80mm dia
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed .
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed.
M&L for Earthing complete for transformer/VCB/ panels with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meters below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32 mm x 6 mm in and including GI pipe 50 mm bore light grade as protection pipe (from top earth plate up to the test point) by means of GI bolts, nuts, check nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15 cm thick, all around including top and bottom and watering pipe 20 mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 mm x 300 mm x 300mm (top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20 mm graded stone aggregate and RCC cover ( 1:2:4) type B-1 using 20 mm graded crushed stone aggregate of 25 mm thick with 2 Nos MS handles of 12 mm dia including necessary excavation /earth work in any type of soil/rock and as shown in Electrical plate no 3 of SSR Part-I (2009) testing on completion complete all as specified. Note:-Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. Note:-Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.
S&F 32 mm x 6 mm galavanised iron strip as earth continuity conductor including fixing from test point to equipment complete all as specified and directed.
S&F 4 mm dia galavanised iron wire as earth continuity conductor including fixing from test point to equipment complete all as specified and directed .
BHARAT ENGINEERS (BID ID -3367508)
R. P. Suppliers and Construction Co. (BID ID -3362773)
JAI DURGA CONSTRUCTION CO (BID ID -3367123)
kailu construction co (BID ID -3367413)
CHOUDHARY AND SONS (BID ID -3367531)
KULBHUSHAN AGGARWAL (BID ID -3366765)
Standard engineers (BID ID -3366792)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .