Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹40.0 L+₹5.8 L (16.8%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹48.3 L+₹14.1 L (41.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance HIGHER RATE | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not submit copy of valid competency cert of 2 AC machenics issued by the OEM only | |
| 5 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Rejected due to required category i.e c (i) not found in enlistment. |
Tender Value
Refer Docs
EMD Value
₹99,940
Closing Date
26 Oct 2024, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF COOLING APPLIANCES, WINDOW/ SPLIT/ CASSETTEE/ TOWER/ PACKAGE TYPE ACs, DEEP FREEZERS, RO, WATER COOLERS AN DESERT COOLERS IN NAVY AREA AND REPAIR/ MAINT OF INTERNAL E/M FITTINGS/ FIXTURES, INTERNAL WIRING, SUBMAIN WIRING AND VTPN DBs
2024_MES_677541_1
NIT No GE/ND-82/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹99,940
Yes
10 Jan 2025
1 Oct 2024
28 Oct 2024
1 Oct 2024
26 Oct 2024
12 Oct 2024
Amount
Labour for checking and attending complaints of ACs, water coolers, deep freezer, RO, Desert cooler,Refrigerators etc. of any capacity, including rectification of minor defects and making the equipment functional complete all as specified and directed. Note : (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints and he must submit copy of valid competency certificate of two(2) AC mechanics each having minium working experience of two years in the field of air conditioning & refrigeration. The certificate should be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, faling which the bid of the contractor is liable to be rejected. (b) Any parts required for replacement shall be measured and paid separately under respective items (c) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Navy Areas (d) The minor complaint should be attended within 2 hours. (e) If the complaint will not attended/not completed within 2 hrs, recovery will be done as follows:- (i) Attending between 2-4 Hours @ Rs 100 (ii) between 4-12 hrs @ Rs.200/- (iii) For next every 12 hrs @ Rs.500/-
Servicing of Split type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items.
S&F in repair starting capacitor 80-100 Mfd suitable for AC 1.5 Ton complete all as specified and directed. Make: Usha/Epcos/Havells/Tesla
S&F in repair starting capacitor 100-120 Mfd suitable for AC upto 2.0 Ton complete all as specified and directed. Make: Arcos/Epcos/Tesla
S&F in repair Running capacitor 36 mfd 230 volt suitable for AC 1.5 Ton complete all as specified and directed. Make : Arcos/Epcos/Tesla
S&F in repair Running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 2.0 Ton complete all as specified and directed. Make : Arcos/Epcos/Tesla
S&F in repair Running capacitor 6 mfd 230 volt complete all as specified and directed. Make : Arcos/Epcos/Tesla
S&F in repair Running capacitor 4 mfd 230 volt complete all as specified and directed. Make :- Arcos/Epcos/Tesla
Supply & charging gas refrigerant R-22/R 410 A/ R-32 or as existing to split type AC up to 2 Ton capacity and testing complete all as specified and directed by Engineer-in-charge. Make- Mafron/Refron/Refromax
S&F in repair starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
S&F in repair over load protector suitable for 1.5/2.0 Ton capacity AC complete all as specified and directed.
S & F in replacement of defective /unserviceable reciprocating compressor of split type AC capacity 1.5 TR, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make : Kirloskar/Carrier/Tecumseh/Copeland/ existing make
All as per item No 12.00 above but rotary compressor of Split type Acs 1.5 TR complete all as specified and directed.
All as per item No 12.00 above but rotary compressor of Split type Acs 2.0 TR complete all as specified and directed.
Supply & fix in replacement air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type ACs complete all as specified and directed.
Material and labour for taking down existing unserviceable blower motor (Indoor) capacity 1/4,1/5 HP single/double shaft as per existing and refixing with new blower motor in replacement as per existing model on site suitable for Split type ACs 1.5/2 Ton complete all as specified and directed.
Material and labour for taking down existing unserviceable outdoor fan motor and fixing of new fan motor capacity 1/4,1/5 HP single/double shaft as per existing model on site suitable for Split type ACs 1.5/2 Ton complete all as specified and directed.
Material and labour for taking down existing unserviceable outdoor fan motor capacity upto 2 Ton and taking the unserviceable fan motor outdoor type to authorized workshop for rewinding of fan motor suitable for ACs capacity up to 2 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and directed.
All as per item No 19.00 above but 4.0 sqmm complete all as specified and directed.
S&F in replacement condensor fan blade suitable for 1.5/ 2.0 Ton capacity split type AC's complete all as specified and directed.
S&F in replacement of evaporating air blower made out of aluminium suitable for 1.5/2.0 Ton capacity for split type AC complete all as specified and directed.
S&F in replacement of synthetic rubber tube insulation of thickness internal diameter (1/4") for refrigerant copper piping of split AC units complete all as specified and directed.
All as per item No 23.00 above but internal dia (1/2") complete all as specified and directed.
All as per item No 23.00 above but internal dia (3/8") complete all as specified and directed.
All as per item No 23.00 above but internal dia (6/8") complete all as specified and directed.
S&F in replacement copper tubing heavy duty inner dia (1/4") for refrigerant for Split type ACs capacity upto 2 Ton complete all as specified and directed.
All as per item No 27.00 above but internal dia (1/2") complete all as specified and directed.
All as per item No 27.00 above but internal dia (3/8") complete all as specified and directed.
All as per item No 27.00 above but internal dia (6/8") complete all as specified and directed.
Material and labour for taking down existing condensing coil by removing it from existing outdoor unit by using LPG blower and fixing of new condensing coil of suitable size/capacity for 1.5/2 Ton split type ACs complete all as specified and directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil
Material and labour for taking down existing evaporating coil by removing it from existing indoor unit by using LPG blower and fixing of new evaporating coil of suitable size of existing make, capacity for 1.5/2 Ton split type ACs complete all as specified and as directed by Engr-in-Charge. Note: Work includes brazing work as required for fixing of condensing coil.
Material and labour for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a or existing type gas for water cooler, Split type/Window type/tower/ductable AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
S&F in replacement brass flare nut/connector heavy duty of size (1/4", 1/2",3/8",6/8) as per existing make complete all as specified and directed.
M&L for Repair of processing control board including replacement of current transformer, ICs, diodes, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
S&F in replacement of unserviceable PCB suitable for Split type 1.5/2.0 Tr complete all as specified and directed. Make: Hitachi/Voltas/Carrier/Daikin
S&F in replacement of unserviceable PCB unit and fixing of new PCB unit suitable for Indoor unit of capacity1.5/2 Ton inverter split type AC complete all as specified and directed by Engr-in-Charge.
S&F in replacement of unserviceable PCB and fixing of new PCB suitable for Outdoor unit of 1.5/2 Ton inverter split type AC complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down unserviceable condensor fan motor of outdoor unit inverter type and supply and fix new DC motor of existing capacity suitable for outdoor unit of Inverter type AC of capacity 1.5/2.0 Ton complete all as specified and as directed by engr-in-Charge
Material and labour for taking down existing unserviceable compressor of Inverter type AC 1.5/2 TR and replacement of same by new hermetically sealed rotary compressor of capacity suitable for Inverter type AC 1.5/2 Ton refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge
S&F in replacement split type AC indoor unit kit 4 star of capacity 1.5 TR complete with cooling coil, blower with motor, PCB and remote complete with fixing plate suitable to existing model and make AC complete all as specified and directed. Make: Hitachi/Daikin/LG
All as per item No 41.00 above split type AC indoor unit capacity 2.0 TR complete all as specified and directed.
S&F in replacement split type AC outdoor kit 4 star of capacity 1.5 TR complete with compressor,copper tubing,insulation,condensing coil, condensor fan motor suitable to existing model and make iron grill, suitable for outdoor unit and flair nuts for connection of Copper pipe complete all as specified and directed. Make: Hitachi/Daikin/LG
All as per item No 42.00 above split type AC outdoor unit capacity 2.0 TR complete all as specified and directed.
S&F in replacement direction changer louver motor (swing motor) suitable for split type ACs 1.5/2 capacity as per existing make and model complete all as specified and directed.
S&F in replacement cordless Remote for split inverter type ACs suitable for 1.5/2 Ton AC as per sample complete all as specified and directed. Make: Hitachi/Voltas/Carrier/LG
S&F in replacement cordless Remote for split ACs suitable for 1.5/2 Ton AC as per sample complete all as specified and directed. Make: Hitachi/Daikin/LG/Carrier
Material and labour for Shifting of Split type Acs 1.5 /2.0 TR capacity to new location including wooden frame, ply of required size removing of indoor unit, out door unit and connected accessories complete all as specified and directed by Engr -in- charge
Material & labour for servicing of ductable AC 8.5 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.
S&F in replacement defective /unserviceable scroll compressor of capacity 8.5 TR ductable AC, refixing new compressor of 8.5 Ton including brazing work etc, pressure testing & establishing vacuum for dehydration of three phase compressor complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs
Supply & charging the gas refrigerant R-22/R 410 A or as existing to Ductable type AC's of capacity 8.5 Ton capacity including removing of leakage if any and testing complete all as specified and directed.
S&F in replacement of LP cut-out suitable for ductable type ACs of capacity 8.5 Ton complete all as specified and directed.
S&F in replacement of HP cut-out suitable for Ductable type ACs of capacity 8.5 Ton complete all as specified and directed.
S&F in replacement of expansion valve suitable for Ductable type ACs of capacity 8.5 Ton complete all as specified and directed.
S&F in replacement of old U/S indoor motor 370 watt 220 volt 50 HZ, single/ double shaft as per existing model suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of old U/S outdoor motor 150 watt 220 volt 50 HZ, single/ double shaft as per existing model suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of air filter synthetic / nylon type as per existing size and shape suitable for ductable AC's of capacity 8.5 Ton complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of unserviceable PCB unit and fixing of new PCB unit suitable for ductable AC of capacity 8.5 Ton complete all as specified and directed by Engr-in-Charge.
Material & labour for servicing of tower type AC 4.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.
S&F in replacement of defective /unserviceable scroll compressor of capacity 4.0 TR tower AC, including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs
Supply & charging the gas refrigerant R-22/R 410 A or as existing to Tower AC's of capacity 4.0 Ton capacity including removing of leakage if any and testing complete all as specified and directed.
S&F in replacement of LP cut-out suitable for tower type ACs of capacity 4.0 Ton complete all as specified and directed.
S&F in replacement of HP cut-out suitable for Tower type ACs of capacity 4.0 Ton complete all as specified and directed.
S&F in replacement of expansion valve suitable for Tower type ACs of capacity 4.0 Ton complete all as specified and directed.
S&F in replacement of old U/S PCB suitable for 4.0 Ton tower AC complete all as specified and directed by Engr-in-Charge.
S&F in replacement of old U/S evaporating air blower made out of aluminium/ plastic suitable for tower AC's of capacity 4.0 Ton complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of old U/S fan motor single/double shaft as per existing model suitable for tower AC's of capacity 4.0 Ton complete all as specified and as directed by Engr-in-Charge.
Material & labour for servicing of VRV/VRF AC 3.0 Ton capacity complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed.
S&F in replacement of defective /unserviceable scroll compressor of capacity 3.0 TR VRV AC, including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Emerson/Hitachi/existing make ACs
Supply & charging the gas refrigerant R-22/R 410 A or as existing to VRV AC's of capacity 3.0 Ton capacity including removing of leakage if any and testing complete all as specified and directed.
S&F in replacement of old U/S PCB suitable for 3.0 Ton VRV AC complete all as specified and directed by Engr-in-Charge.
Material & labour for servicing of VRV/VRF modular type hot & cold inverter type cassette air conditioner with inbuilt stabilizer complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed. outdoor unit - 06 HP-09 Indoor unit - 04 TR-09
Supply & charging the gas refrigerant R-22/R 410 A or as existing to VRV system hot and cold inverter type including removing of leakage if any and testing complete all as specified and directed.
Material & labour for servicing of VRV/VRF modular type hot & cold inverter type air conditioner with inbuilt stabilizer complete with blower motor dismantling all parts carefully and carryout servicing, cleaning the external surface (both side) and fan of the unit out side of the equipment like base plate runner fan blade thoroughly with the help of descaling chemical, brush, water, air blower and dry properly complete all as specified and directed. outdoor unit - 26 HP-03 Nos Indoor unit - 7.8 TR-09 Nos
Supply & charging the gas refrigerant R-22/R 410 A or as existing to VRV system hot and cold inverter type including removing of leakage if any and testing complete all as specified and directed.
Material and labour for Servicing of Water cooler of 40,120,150 ltr capacity of any make / model by cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning, greasing, oiling of fan motor and checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134 or as existing to water coolers up to 150 ltr capacity including removing of leakage if any and testing complete all as specified and directed.
S & F in replacement of defective /unserviceable reciprocating compressor of Water Cooler 120-150 L & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Tecumseh/Copeland/Emersons
S & F in replacement of old U/S condensing coil of water cooler any capacity including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of old U/S fan motor of water cooler capacity upto 150 Litres along with fan blade complete all as specified and directed by Engr-in-Charge.
Material and labour for Servicing of Refrigerators of 195 to 310 ltr capacity single door of any make / model by cleaning of condensing coil with wire & brush to remove dust including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge.
S & F in replacement of old U/S condensing coil of refrigerator of capacity upto 310 Ltr including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of old U/S fan motor of refrigerator capacity upto 310 Litres along with fan blade complete all as specified and directed.
S & F in replacement of defective /unserviceable reciprocating compressor of refrigerator 310 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Tecumseh/Copeland/Emersons
Supply & charging the gas refrigerant R-134a or as existing to Refrigerators up to 310 ltr capacity including removing of leakage if any and testing complete all as specified and directed.
S&F in replacement of unserviceable starting relay suitable for 195 to 310 ltr capacity Refrigerator complete all as specified and directed.
S&F in replacement of unserviceable over load protector suitable for Refrigerator capacity upto 310 ltrs complete all as specified and directed.
S&F in replacement thermostat switch suitable for Refrigerator capacity upto 310 L complete all as specified and directed.
Material and labour for Servicing of Deep freezer upto capacity 1300 Ltr 2/3/ 4 door of any make / model by cleaning of condensing coil with wire & brush to remove dust ,oiling and greasing as required including checking of electric circuit for smooth functioning complete all as specified and directed by Engr-in-Charge
Supply & charging the gas refrigerant R-134a or as existing to Deep Freezers up to 1300 ltr capacity including removing of leakage if any and testing complete all as specified and directed.
S & F in replacement of old U/S condensing coil of deep freezer of capacity 1300 Ltr including brazing and dehydration by creating vacuum for more than 24 Hrs so that no oil/sludge remains in the cooling coil/system complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of old U/S condensor fan motor of deep freezer capacity 1300 Ltr along with fan blade complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of old U/S condensor fan motor of deep freezer capacity 492 Ltr along with fan blade complete all as specified and as directed by Engr-in-Charge.
S & F in replacement of defective /unserviceable reciprocating compressor of deep freezer of capacity 492 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons
S & F in replacement of defective /unserviceable reciprocating compressor of deep freezer of capacity 1300 Ltr & refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed by Engr-in-Charge. Make:- Kirloskar/Tecumseh/Copeland/Emersons
S&F in replacement of unserviceable starting relay suitable for 165 to 1300 ltr capacity Deep freezer complete all as specified and directed.
S&F in replacement of unserviceable over load protector suitable for Deep freezer capacity upto 1300 L complete all as specified and directed.
S&F in replacement thermostat switch suitable for Deep Freezer upto 1300 L complete all as specified and directed.
S&F in replacement of old U/S single phase voltager stabilizer floor mounting type of capacity 01 KVA,Minimum input voltage 90-130V,minimum output voltage130V, maximum output voltage 290-300 Volts including digital display,digital indicators,over volt protection and overload protection complete all as specified and directed by Engr- In- Charge.
S&F in replacement of old U/S single phase voltager stabilizer floor mounting type of capacity 02 KVA,Minimum input voltage 90-130V,minimum output voltage130V, maximum output voltage 290-300 Volts including digital display,digital indicators,over volt protection and overload protection complete all as specified and directed by Engr- In- Charge.
S&F in replacement of old U/S single phase voltager stabilizer floor mounting type of capacity 04 KVA,Minimum input voltage 90-130V,minimum output voltage130V, maximum output voltage 290-300 Volts including digital display,digital indicators,over volt protection and overload protection complete all as specified and directed by Engr- In- Charge.
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
S&F in replacement Metal Clad Plug & socket enclosure with with MCB SP 20-32 Amps complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of PVC insulated and PVC sheathed, flexible copper conductor cable 3 core, 1100 volts grade, multi stranded type of size 6.0 sqmm complete all as specified and directed.
Material and labour for taking down of desert cooler and Servicing of Desert cooler of any type/ capacity, cleaning of tank including checking of electric circuit for smooth functioning of desert cooler complete all as specified and directed.
S&F in replacement of desert cooler pad for desert cooler (PVC Body type) complete (in set of three) as per sample suitable for cooler of Size as required at site complete all as specified and directed.
S&F in replacement ON/OFF switch of desert cooler complete all as specified and directed.
S&F in replacement of step type regulator with switch complete plate for desert cooler complete all as specified and directed.
S&F in replacement of drain pipe PVC flexible, spring type of size 15 mm dia as per site requirement complete all as specified and directed.
S&F in replacement of water lifting pump for desert cooler of any capacity as per sample complete all as specified and directed by Engr-In-Charge.
S&F in replacement of desert cooler fan motor with supper enameled copper winding wire of same gauge (as per sample) complete all as specified and directed.
M & L for servicing of RO Plant of capacity upto150 LPH including replacement of minor spares,cleaning of filters/membranes and refixing the RO after repair, testing complete all as specified and directed of entire satisfactory level by Engr-in charge. Note: Spares required shall be measured and paid under relevant items
S&F in repair Membrane suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair Membrane housing suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair Filter heavy Grade suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair Solenoid valve suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair activated carbon Filter heavy Grade for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair HDPE pipe 3/8"dia suitable for inlet & outlet of RO plant complete all as specified and directed.
S&F in repair booster pump for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair CTO Filter suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair SMPS suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair UV tube suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair UV barrel housing suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair high pressure switch suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
S&F in repair replacement of low pressure switch suitable for 50 to 150 LPH RO Plant complete all as specified and directed.
Comprehensive maintenance and servicing of water treatment plant (INDROMATIC-402, sand filter, Antiscalent doser) including through checking of all parts,additional visit of engineer /supervisor to ensure that system work smoothly during entire contract period. Comprehensive maintenance also include chemical cleaning of plant and replacement of all parts such as filter media,carbon media,cartridge,RO Membrane,Antiscalent chemical,repair high pressure and raw water pump etc complete all as specified and directed. Note: Chemical cleaning of plant should be done on quarterly basic.
M&L for comprehensive maintenance of Servo Voltage Stabilizer/ Servo Voltage Regulator, 10/20 KVA, comprising of following jobs complete all as specified and as directed:- (a) Taking out of electric connection of defective voltage stabilizer and transport it to workshop for repair, opening up and taking out coil, core and core assembly for repair including cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's, Regulators, Condensers, Triac, Transistors etc. respective cards nuts and bolts, transport to site including installation,connecting the electric connection and testing on full load. Note:- (i) The rates quoted by the contractor shall deemed to be inclusive of T&P and minor sundries items etc as required. (ii) Major Spares Part shall be measured and paid for separately under respective item of this Schedule. The parts which are not These shall be identical to those specified by the original manufacturer. (iii) Any items not covered under as supply & Fix/M&L shall be deemed to be included in this section for the smooth functioning of voltage stabliser and the contractor may quote the rate accordingly. Contractor is expected to inspect the stabliser before quoting the rate.
M&L for repair and rewinding dimmer suitable for 10 KVA voltage stabilizer including taking out old winding complete all as specified and directed.
M&L for repair and rewinding buck/boost loading transformer complete suitable for 10KVA voltage stabilizer including taking out old winding complete all as specified and directed.
S&F in repair cut off circuit with contactor suitable for 10 KVA voltage stabilizer complete all as specified and directed.
S&F in replacement control wiring of Servo Voltage Stabilizer/ Servo Voltage Regulator, 10/20 KVA complete all as specified and directed.
S&F in replacement electronic control card, suitable for 10 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed.
S&F in repair Synchronus motor 10kg torque, suitable for 10 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed.
S&F in replacement RC network, suitable for 10 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed.
S&F in replacement DPDT switch, suitable for 10 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed.
S&F in replacement sensing transformer, (16V/1Amp, 12V/1 Amp), suitable for 10 KVA Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed.
S&F in replacement of switch piano flush type 6 Amp, SP, one way 230 volts AC complete all as specified and directed.
S&F in replacement of switch piano flush type 6 Amp SP two way 230 volts AC complete all as specified and directed.
S&F in replacement of bell push switch piano flush type 6 Amps, SP, 230 Volts AC complete all as specified and directed.
S&F in replacement of switch piano flush type 16 Amp, SP, one way 230 volts AC complete all as specified and directed.
S&F in replacement of piano flush type socket out let 5 pin 6 Amp, 230 volts AC complete all as specified and directed.
S&F in replacement of piano flush type socket out let 6 pin 16 Amp, 230 volts AC complete all as specified and directed.
S&F in replacement of piano type electronic fan regulator suitable for 1200/1400 mm ceiling fan complete all as specified and directed.
S&F in replacement of call bell suitable for 230 volts AC complete all as specified and directed.
S&F in replacement of ceiling rose 3 terminal / PVC / Polycarbonate, insulated body complete all as specified and directed.
S&F in replacement of decorative lamninated sheer 3 mm thick of size 9"x13" including necessary cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in replacement of decorative lamninated sheet 3 mm thick of size 9"x11" including necessary cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in replacement of decorative lamninated sheet 3 mm thick of size 8"x5" including necessary cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in replacement of decorative lamninated sheet 3 mm thick of size 5"x5" including necessary cutting of sheet for fixing switch/socket complete all as specified and directed.
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1.5 Sqmm complete all as specified and directed.
S&F in replacement of single core,FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 2.5 Sqmm complete all as specified and directed.
S&F in replacement for MCB SP 06 to 32 Amps 240 Volts, 10 KA, `B/C' curve, all as per site requirement complete all as specified and directed.
S&F in replacement for MCB SPN 32 Amps, 240 Volts, 10 KA, `B/C' curve, all as per site requirement complete all as specified and directed.
S&F in replacement MCB TPN/ Isolator 4P ,63 Amps 415 volts, 'B/C' Series 10 KA as per site requirement complete all as specified and directed.
S&F in replacement of MCCB TP 63 Amp, 415 Volts,36kA thermal type complete all as specified and directed.
S&F in replacement of MCCB TP 125 Amp, 415 Volts , 36kA adjustable type complete all as specified and directed.
S&F in replacement of metal clad plug top 20 Amp, 230 volts AC complete all as specified and directed.
S&F in replacement of metal clad socket outlet 20 Amps, 230 volts AC complete all as specified and directed.
S&F in replacement of LED Batten fitting 10 watt - 2FT White, indoor decorative aluminium extruded complete all as specified and directed.
S&F in replacement of LED Batten fitting 20 watt LED White, indoor decorative aluminum extruded complete all as specified and directed.
S&F in replacement Decorative wall light made up of high grade engineering plastic material suitable for 9 W LED lamp B22 base complete all as specified and directed. Make: Havells Cat Part No LHFHCHE1TL1W020 or equivlent of make as specified in PS.
S&F in replacement of LED Building security light fitting 25W energy saving and environmental friendly made up of pressure diecast aluminium housing with high power LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection complete all as specified and directed.
S&F in replacement of B-22 holder suitable for Led bulb 9-15 watts complete all as specified and directed.
S&F in replacement of fan capacitor 2.5 Mfd complete all as specified and directed.
S&F in replacement of fan capacitor 3.15 Mfd complete all as specified and directed.
S&F in replacement remote controlled Ceiling fan complete with blades,down rods and all connected accessories operating at 230 V with 1200 mm sweep, rated 5 star with brushless direct curent (BLDC) motor,color as per site requirement.Making arrangement for hanging fans to ceiling with proper hook,nut,bolt with twin core twisted flexible copper conductor complete all as specified and directed by Engineer-In-Charge Note:-The old U/S 1200/1400mm sweep ceiling fan to be deposited to MES store yard in safe custody.
S&F in replacement of ceiling fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed.
S&F in replacement of 'U' clamps with rubber reel, bolts, nuts, washers and safety pin ceiling fan of any size/ make complete all as specified and directed.
S&F in replacement of Down rod of 1' height fabricated out of MS pipe 12mm dia heavy duty duly painted with one coat of white paint complete all as specified and directed.
S&F in replacement of Canopy of Celing fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint complete all as specified and directed.
S&F in replacement of blade (set of three) of Celing fans of 1200/1400mm swipe size heavy duty duly painted with one coat of white paint (As per sample) complete all as specified and directed.
S&F in replacement of blade (set of three) of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour (As per sample) complete all as specified and directed.
S&F in replacement of metal frame of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour (As per sample) complete all as specified and directed.
S&F in replacement of motor with copper winding of exhaust fans metal body of 300 mm swipe size heavy duty duly painted with one coat of paint of suitable colour (As per sample) complete all as specified and directed.
M&L for spray painting two coat (white colour) with synthetic enamel paint to Ceiling fans/Exahust fan of any capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
M&L for spray painting two coat (white colour) with synthetic enamel paint to Geysers 25/50 Liters capacity to reach upto satisfied finish of painting after cleaning and preparation of surface complete all as specified and directed by Engineer-in-charge.
S&F in replacement of heating element of 1.5 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc (As per sample) complete all as specified and directed.
S&F in replacement of heating element of 2.0 KW (triangular/circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed.
S&F in replacement of storage tank made out of stainless steel sheet of appropriate thickness for 25 litre capacity geysers with collar complete duly tested at required pressure complete all as specified and directed.
S&F in replacement of insulating material (Glass wool) for 25 litre capacity Geysers complete all as specified and directed.
S&F in replacement of base plate assembly 20 SWG heavy duty suitable for 25 litre capacity stainless steel tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site (As per sample) complete all as specified and directed.
S&F in replacement of chromium plated connection pipe 600mm long with two brass adopters washers and connecting up complete all as specified and directed.
S&F in replacement of PVC connection pipe 450mm long with two brass adopters washers and connecting up complete ISI mark complete all as specified and directed.
S&F in replacement of safety nut for high pressure release (As per sample) complete all as specified and directed.
S&F in replacement of non return valves 15mm dia and connecting up complete (ISI marked) complete all as specified and directed.
S&F in replacement of top cover for geysers of 25 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and directed.
S&F in replacement of bottom cover for geysers of 25 ltr any make required at site duly painted with synthetic enamel spray paint (first quality) with inspection plate in two pieces complete all as specified and directed.
S&F in replacement of outer cover for geyser made out of MS sheet suitable for 25 ltrs capacity geyser vertical/horigontal type complete all as specified and directed.
S&F in replacement of thermostat (ISI Marked) for 25 Liters capacity Geyser complete all as specified and directed.
S&F in replacement of indicator lamp (Red & Green) 230 volts suitable for Geyser (as per sample) complete all as specified and directed.
S&F in replacement of of mild steel hole fastner 10mm dia, 100mm long including nut and washer complete all as specified and directed.
S&F in replacement of 15 mm gun metal valve complete all as specified and directed.
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket and making good the disturbed surface of wall/ floor complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switches, sockets & fan regulators for one light/ fan point controlled by one No, 6 Amp one way switch complete all as specified and directed. Note : In existing conduit wiring (new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes
All as per item No 194.00 above but 6 Amp socket outlet point controlled by one No, one way switch on same board complete all as specified and directed.
All as per item No 194.00 above but 6 Amp socket outlet point controlled by one No, one way switch on independent board complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS type, copper conductor cable of size 2.5 sqmm as earth continuity conductor connected to common earth dolly, in and including PVC concealed rigid non-metallic conduit medium grade and its accessories including provn of new galvanised sunken box including decorative sheets for housing the piano type switces and sockets on independent board complete all as specified and directed. Note : In existing conduit wiring (new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes Note for item No 194 to 197- (i) Cutting chases for concealed conduit and making good in cement mortar is deemed included in unit rate. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required. (iii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
S&F in replacement of PVC Casing Caping of size 1" complete all as specified and directed.
S&F in replacement of PVC conduit 20mm dia, rigid, complete all as specified and directed.
S&F in replacement of flexible PVC pipe of 20mm dia complete all as specified and directed.
S&F in replacement of LED Glass Bulb 10 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/wall light fittings complete all as specified and directed.
S&F in replacement of single core, FRLS cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 4 Sqmm complete all as specified and directed.
S&F in replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in existing conduit along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly complete all as specified and directed.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 4 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 8 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
S&F in replacement of factory made concealed sheet steel distribution boards, double door, SPN, 12 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 4 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified and directed.
S&F in replacement of factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified and directed.
S&F in replacement Rugby Bulk head 9 watt in die cast aluminium housing & frosted glass complete all as specified and directed by Engineer-In-Charge. Make: Havells Cat Part No LHKL01160099 or equivalent of make as specified in PS.
S&F in replacement of Exhaust fan Louvers 300 mm Size of iron upto forth floor including taking out old louvers complete all as specified and directed. Note:-ladder arrangement for fixing louvers will be made by contractor.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing and taking down of old unsv earthing any type complete all as specified and directed.
S&F in replacement of two core flexible cable, PVC insulated, unsheathed, multi stranded copper conductor cable of size 1 Sqmm complete all as specified and directed.
S&F in replacement of aesthetically designed ceiling/surface mounting circular shaped decorative green perform sleek LED downlighter of 09 W fixture with opal diffuser to give glare free light including suitable LED lamp complete all as specified and directed.
S&F in replacement of aesthetically designed ceiling/surface mounting circular shaped decorative green perform sleek LED downlighter of 15 W fixture with opal diffuser to give glare free light including suitable LED lamp complete all as specified and directed.
Supply & Laying in replacement of XLPE LT cable 25 sqmm 3.5 core1100 volts grade heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC Tape armoured with galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendments laid in tranches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling also including necessary excavation, returning filling, removal, sand cushioning and brick layering etc as required complete all as specified and directed.
All as per item No 215.00 above but for size 50 sqmm 3.5 core complete all as specified and directed.
SNOWY ENGINEERING INC (BID ID -3150768)
Verma Enterprises (BID ID -3147968)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .