Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Aug 2026, 6:00 pmDue today
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS AND REPLACEMENT OF CONTROL SWITCH GEAR ELECTRIC CONTROL VFD AUTOMATION SYSTEM SCALE PREVENTOR AT RCI UNDER GE I RND RCI HYDERABAD
2026_MES_782423_1
8464
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹90,000
Yes
3 Aug 2026
3 Aug 2026
26 Aug 2026
3 Aug 2026
24 Aug 2026
17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Draining out the old existing unserviceable compressor oil from the AC plant compressor of any capacity and type, supply and Charging of suitable/ same as existing make Compressor Oil complete all as directed by Engineer-in-Charge. | 50 | Ltr | - | - |
| 2 | Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed.
Make : Refron/Mefron/Freon | 305 | KG | - | - |
| 3 | Descaling of condenser any capacity by circulating descaling agent (DC-96) through condensers by forced feed method by removing the end covers of the condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing the end covers with new rubber gasket, nuts bolts, washers and testing complete all as directed. | 20 | Each Job | - | - |
| 4 | Opening covers of AHU, descaling of the AHU coil/ Condensor coil to bring down the high pressure, cleaning of the dust particles formed on the coil system with diluted 'ASFOCLEAN' chemical or Caustic Soda by pouring on the coil with leg pump or mechanical system till the clearing of the dust on the coil as primary wash and using detergent powder or surf water as final wash, testing complete all as directed. | 20 | Each Job | - | - |
| 5 | Disconnecting the unserviceable VFD Drive from the existing position and repair,fix, connecting & testing VFD drive complete all as specified and directed by the Engr-in-Charge. | 2 | Each Job | - | - |
| 6 | Disconnecting and removing the unserviceable Main Controller / PCB from existing AC Plant of capacity 50 to 75 TR and replace with new main Controller / PCB in repairs all as specified and directed | 1 | Each Job | - | - |
| 7 | Disconnecting and removing the un-serviceable TCPM board of chiller unit of 50 TO 75 TR chiller in AC plant of Any Model,Type and Make, from the existing position, supply and fixing in repairs new TCPM Board all as specified and directed by Engr-in-Charge. | 1 | Each Job | - | - |
| 8 | Disconnecting and removing the un-serviceable TCPM board of chiller unit of 90 TO 125 TR chiller in AC plant of Any Model,Type and Make, from the existing position, supply and fixing in repairs new TCPM Board all as specified and directed by Engr-in-Charge. | 1 | Each Job | - | - |
| 9 | Disconnecting and removing the unserviceable EXV Module from existing 90 TO 125 TR AC plant of Any Model,Type and Make and replace with new EXV Module in repairs all as specified and directed | 1 | Each Job | - | - |
| 10 | Disconnecting and removing the unserviceable RTAA Display Board from existing 90 TO 125 TR chiller in AC plant of Any Model,Type and Make, replace with new RTAA Display Board in repairs all as specified and directed | 1 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_876578.xls
BOQ • 0.30 MB
8464PS.pdf
Tender Documents • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].