Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC GAUSHALA MARKET OPP BUS STADND NARNAUL 123001 | MAHENDRAGARH | HARYANA | 123001 | ₹1.0 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹1.1 Cr+₹5.8 L (5.79%)Rejected-AOC JIND JIND HARYANA | JIND | HARYANA | 126101 | ₹1.1 Cr+₹5.8 L (5.79%) | L2 | Rejected-AOC Reject |
| 3 | L3₹1.1 Cr+₹8.6 L (8.59%)Rejected-AOC | ₹1.1 Cr+₹8.6 L (8.59%) | L3 | Rejected-AOC Reject |
| 4 | Not Admitted-Fee/PreQual/Technical VPO NEEMAR BADESRA TEHSIL BADHRA AND DISTT CHARKHI DADRI 127308 | CHARKI DADRI | HARYANA | 127308 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹88.8 L
EMD Value
₹1.8 L
Closing Date
1 Jun 2021, 2:00 pmClosed
Executive Engineer, M/Garh Canal W/S Division, NNL
Executive Engineer, M/Garh Canal W/S Division, Narnaul
Laying pressurized pipeline for filling village pond of Nayan at Km 19.750 i.e. PH NLD-6 of Nolpur Disty.
2021_HRY_172111_6
No. 1662-74/6A Dated 10/05/2021
Open Tender
Civil Works
Item-rate/Agreement basic
90 days
NARNAUL
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
₹1.8 L
Yes
12 Jul 2021
20 May 2021
2 Jun 2021
20 May 2021
1 Jun 2021
20 May 2021
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 meters (HSR item no. 6.6)
CC 1:3:6 with stone aggregate 20 mm nominal size foundation & plinth (HSR 10.40)
CC 1:4:8 with stone aggregate 20 mm nominal size foundation & plinth (HSR 10.38)
CC 1:2:4 with stone aggregate 20 mm nominal size for RCC work but excluding steel reinforcement centering shuttering in foundation and plinth (HSR 10.79)
Centering and shuttering for flat surface such as suspended floors roofs, landing etc. (HSR 9.5)
B/W 1:4 Cement sand mortar (HSR 11.4)
DPC 1:2:4 at plinth level 25mm thick (HSR 10.115)
Cement Plaster 1:4 12mm thick (HSR 15.5)
Conglomerate flooring 40mm thick C.C. 1:2:4 on 100mm CC 1:8:16 and 100mm sand or stone filling (HSR 14.12)
Tile terracing with one layer of tiles 22.86 x 11.43x3.81cm laid dry over a layer of mud mortar with cement sand mortar 1:3 & top surface to be left clean (HSR 13.14)
Steel Reinforcement in Covers. (HSR item No. 18.22)
Door and window pressed steel sheet frame consisting 2 mm thick steel sheet of specified section including iron lugs, iron hinges. conforming to PWD specifications including bolts for fixing stops lock notch provision for receiving tower bolts and finished with all feting (HSR 18.34-A).
Wrought iron & mild steel for door & window /ventilator etc. (HSR 18.12)
Providing laying cutting joining the HDPE Pipe 200 mm PE 100PN6 including nut & bolts including carriage, loading & unloading handling re-handling etc. complete in all respect to be satisfaction to the Engineer-In-Charge(29.98)
Providing & fixing C.I kinetic air wall size given below including carriage, loading & unloading handling re-handling etc. complete in all respect to the satisfaction to the Engineer-In-Charge (HSR 28.13a) 80mm dia
Providing & fixing cast iron Double Flanged Sluice Valve PN-1.6 marked with IS:114846 including nuts & bolts marked with IS:1363 Rubber sheet marked with IS:638 etc. carriage, loading & unloading, handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-In-Charge (HSR 28.10e)200mm dia
Providing and fixing C. I. Double Flanged Swing Check type Reflux(Non Return) Valves PN -1.6 Marked with IS: 5312 including nuts & bolts marked with IS: 1363 , Ruber sheet marked with IS: 638 etc. carriage , loading unloading, stacking handling, Re- handling etc. Complete in all respect to the satisfaction of Engineer - in - Charge (Make. AARKO, VENUS, LEADER, SI,PANJA, UPADHAY.) Complete in all respects. (HSR item No. 28.10-A) 200mm dia
Providing & fixing C.I specials tee, bend, reducer etc. including carriage, loading & unloading handling re-handling etc. complete in all respect to the satisfaction to the Engineer-In-Charge
Supply erection testing and commissioning on one electric pumping set with motor suitable capacity of 1620 LPM with 20 HP with 60 mtr Head Squirrel cage induction motor 1440 RPM 3 Phase complete in all respect.
Supply erection testing and commissioner of wall mounted electrical panel board started fabricated from 16 SWG CRCA sheet duly scouted with suited angle iron frame worked of size 1200x900x40mm having following items (A) Main switch 63 Amp.=1No.,100 Amp.=1 No. L&T ,Slermens,ABB (B) Volt meter 100x100mm (AC/KAPPA/L&T) (C) Amp. meter 100x100mm (AC/KAPPA/L&T) (D) CT 1001 (AC/KAPPA/L&T) (E) VSS &ASS AC/KAPPA/L&T) (F) SPP 01 No. of approved make (i) Motor starter star delta for 1620 LPM 40 Mtr. head & boosting station. (G) Capacity KVAR at per site requirement including lamp set.
Supply and erection of PVC sheathed Copper conductor cable single core 1100 volts grade in pipe etc., of suitable size excluding cost and erection or pipe (HSR item No. 31.11(v))
Providing Fixing GI pipe 80mm Class-C for air valves.
White washing 3 coat for new work (HSR 16.48).
Writing letter on top of pump chamber
jaipal singh s/o sardara singh
AJIT SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .