Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.2 CrAccepted-AOC C O APERNA TRADERS COURT ROAD UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.2 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.3 Cr+₹3.9 L (3.14%)Rejected-Finance VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.3 Cr+₹3.9 L (3.14%) | L-2 | Rejected-Finance other than L-1 |
| 3 | L-3₹1.6 Cr+₹35.5 L (28.6%)Rejected-Finance | ₹1.6 Cr+₹35.5 L (28.6%) | L-3 | Rejected-Finance other than L-1 |
| 4 | L-4₹1.6 Cr+₹37.4 L (30.1%)Rejected-Finance | ₹1.6 Cr+₹37.4 L (30.1%) | L-4 | Rejected-Finance other than L-1 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
17 Sept 2020, 6:00 pmClosed
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-11 and P-13 AT PB ENCLAVE UNDER GE (NORTH) UDHAMPUR
2020_MES_355096_1
CWE/U(N)-49/2020-21
Open Tender
Civil Works
Item Rate
300 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹1,000
GE (North) Udhampur
₹2.2 L
Yes
2 Nov 2020
23 Jun 2020
19 Sept 2020
23 Jun 2020
17 Sept 2020
5 Sept 2020
Amount
Providing and maintaining Barricading on the site 2.5 m high by using MS Pipes or angle iron frame work of verticals at 3 m c/c and horizontals at 0.90 m c/c, Galvalume sheets, Struts, MS Clamps, etc. The rate to include fabricating, cutting and fixing in position MS frame work , painting the same with wto coats of approved anti rust paint etc complete, the contractor to get structural design approved by the Engr-in-Charge. Contractor shall remove and take away the barricading at his own cost on completion of the works.
Chipping /removing loose concrete up to reinforcement bars, without damaging the reinforcement, removing all the loose materials and to make all the exposed surfaces free from oil, dust and all impurities etc., complete all as specidied and as directed.
Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying polymer bond to the old concrete surface before applying Polymer mortar, complete all as specified and as directed. Make : “SIKA - SIKA Rust off 100 or SIKA S.B.R or Latex power” ” FOSROCK – Reebaklens RR or Nitobond AR”
Application of Corrosion Inhibitor: Providing & applying One coat of Concrete Penetrating Corrosion Inhibitor (Surface applied) which works on Bipolar Inhibition Mechanism on entire concrete surface to be repaired by using brush or spray at 250 ml per Sq.Mt./Coat or as per manufacturer’s specification and prior to application of first coat of anti corrosive coating to reinforcement, complete all as specified and as directed. Make : "SIKA – Feroguard 903” or "FOSROCK – Auramix BCI”
Providing Micro Concrete jacketing to walls or beams of thickness upto 75 mm using Polymer modified cement premixed quartz sand aggregate packed in bags of standard manufacture, for high early strength of 40 N/mm sq.cm of approved brand. The dry product is to be mixed with 12.5% water by weight, along with washed and poured into rigid form work moulds & tamped properly, & cured for 3 days. [Payment is to be made by weight premixed of micro concrete product consumed as per site register records. No extra payment shall be made for shuttering or any other material, complete all as specified and as directed. SIKA – Sika Rep microconcrete - 4” ” FOSROCK – Renderoc RG”
Providing and applying Polymer modified cement mortar of average thickness 15-20mm using Polymer in one or more layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster, complete all as specified and as directed. Make : "SIKA – Sika 122 WL” or "FOSROCK – Renderoc S2”
Providing and applying Polymer modified cement mortar of average thickness 30-40mm using Polymer in two layers in proportion 1:5:15 of Polymer Cement Quartz Sand as manufacturer’s specifications in specific layers, curing the surface after 72 hours of application with wet gunny bags etc and by finishing the surface with 12mm thick (1:3) Cement sand plaster, complete all as specified and as directed. Make : "SIKA – Sika 122 HS” or "FOSROCK – Renderoc HS xtra”
Shear Connectors: Making 10/12 mm dia holes using heavy duty electrically operated hammer drills in the concrete of RCC members to a depth of about 75 mm at 500 mm c/c or at suitable grid in zig-zag fashion, clean the holes using air jet and fix pre-fabricated 100 x 50 mm L-shape 8 mm dia rebar using Anti Corrosive protective coating so that 75 mm out of 100 mm is inserted inside the concrete and 25 mm remain outside along with 50 mm bend. The shear connectors are used to tie the additional reinforcement bars, complete all as specified and as directed. Make : FOSROCK – HILTI, Fischer”
Mid steel TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500D, complete all as specified & directed.
Bond Coat : Providing & applying one coat of structural grade epoxy bond coat by brush conforming to ASTM-C-882-87 to the prepared concrete surface to be repaired / strengthened. This is applied prior to the application of polymer repair mortar / epoxy mortar / Microconcrete to have monolithic action between old concrete surface and new concrete surface, complete all as specified and as directed. SIKA – SIKADUR 32 LP, HIBOND”
Providing and applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc., complete all as specified and as directed. Make : "SIKA – SIKA Latex or SRB” or "FOSROCK – Nitobond EP”
Providing precast cement concrete louvres and jallies of 35 mm thick, (measured solid), including all mouldings but excluding frame in Nominal Mix 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:4 (1 cement: 4 fine sand) etc. complete excluding plastering of the jambs, sills and soffits, complete all as specified and as directed.
Demolition of cement concrete (un reinforced) as in roofs of existing water proofing treatment of any type and any thickness, complete all as specified and as directed by Engr-in-Charge.
Roughing surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc for local depressions RCC surfacewill be finished and rendered with 10mm thick cement plaster in CM (1:4) using water proofing compound over and including Brushing neat cement slurry with 3.0kg of cement per sq. metre finished even and smooth without using extra cement and the sand used for the same will be clean and free from any silt, organic matter and impurities. RCC and plastered surface will be wet cured for minimum period laid down in IS 456 & then allowed to dry and leakage checked by pointed test atleast 72 hrs. After checking of leakages on dry plaster surfaces apply bituminous primer conforming to IS 3384 @ 0.40 Kgs/sqm on plastered surface on sunny day. After the primed surface has dried and apply a coat of hot blown VG-20 penetration grade blown bituben, confiming to IS-702 @ 1.20 kg/sqm on the surfaces provide APP (Atactic Polyoropylene) modified polymeric five layered membrane with central core 100 micron high molecular high density firm. Minimum weight of mambrance will be 3Kg/Sqm . APP membrane will be laid across the slope from lowest line sloping roof towards ridge with minimum end lap of 150mm & side lap of 75mm bonded with hot blown bitumen. Over the APP membrane apply semi hot blown VG-20 penetration grade bitumen " 1.2Kg/Sqm and blinded with fine sand in dry condition " 0.50 Kg/Sqm dusted over the bitumen coat. Note :- 1. The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer. 2. Edges of membrance shall also be inserted into groove made in Parapet wall up to a height of 100mm above.
20mm thick precast machine pressed factory made PCC tiles as in 1:2:4, type B-0, 250 x 250mm size and 22mm thickness with grey cement and no pigment on and including bedding layer of 15mm thick cement mortar 1: 4 mixed laid with 5 mm wide spaces and joint filled with 5% creosote oil, jointed & pointed flush in cement mortar 1: 1 complete all as directed. (Make: Modern/ Hindustan / SS Tiles/ Ruchi)
Providing and laying water proofing treatment to sunken portion of WCs, bathrooms, etc by applying first layer of slurry of cement @ 0.488kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253kg/sqm this layer allowed to air cure for 4 hrs then applying slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg/sqm and allowed to aircure for 4 hrs and joints seal with sealing compound as approved by GE. Note: (i) Before laying of lime concrete contractor shall carried out at least 8 hrs ponding test for any leakage in each sunken portion and joints of trap/WC/Soil pipes shall be properly sealed with sealing compound of Roofex/Forre/FOSROC and provn of P or S trap & Nahani /Floor traps with long arm and also provn of spout of 40 mm dia.
15mm thick plastering in cement mortar 1:3 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified.
PCC 1:5:10 type E-2 using 40mm graded crushed stone aggregate as in as in sunken portion treatment, complete all as specified and as directed.
Water proofing treatment to the chajja after removing old plaster and roughening the surface and finishing the top surface with 20mm thick 1:3 cement mortar plaster with approved water proofing compounds including rounding portion in between wall & chajja top and neat cement finish, the rate also includes for 1:3 cement mortar facia of chajja to match the new surface (actual area treated will be paid), complete all as specified and as directed.
15 mm thick rendering in two layers (10+5mm) on fair faces of brick /concrete including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and fair without using extra cement complete all as specified and as directed by Engr-in-Charge.
12mm thick plastering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and fair without using extra cement, complete all as specified.
Applying 1 to 1.2mm thick wall care putty on plastered surfaces of wall, complete all as specified.
Removing any kind of debris/Demolished building material outside A-1 def land including loading in truck and conveying day to day basis to beyond the lead included in the rates, including loading, unloading and stacking at the destination approved dumping point etc. complete with all lifts and lead of 5 Km out side MD land, complete all as specified and directed by Engr-in-Charge. Note: 1.The contractor shall take necessary permission of Civil Auth if needed for removal of Debries on out side MD land and quoted rates deemed to be inclusive. 2. The full lorry of debris having minimum size not less than 200 cubic feet shall be considered as one load for payment purpose.
Note for item No. 1 to 11, 19 & 20 : (i) Work shall be executed only through authorized applicator of manufacturer. (ii) All scaffolding work and safety measures such as provision of props and supports shall be of Steel and, extent of provision shall be to the entire satisfaction of GE. (iii) After obtaining approval of the makes of products the Contractor shall give a letter from the manufacturer regarding the details of agency and name of Person to be deployed for carry out repair & supervisor of work. (iv) The T&P shall be strictly as per manufacturer instruction. (v) Necessary Jacks shall be errected to support various floors before exposing columns/beams for repair and it shall also be ensured that no damage is made to the existing structure during repair process & all safety norms shall be followed. (vi) Contractor shall furnish a written guarantee for structure repairs carried out under above ser items of BOQ for a period of five years. An amount to the tune of 5% of total amount Quoted against ser item 01 to 11, 19 & 20 or RS.50,OOO.OO whichever is less shall be held back from' Contractors payment as security deposit against the guarantee period of 5 years from certified date of completion. Which shall be refunded to him after expiry of this period. Alternatively Contractor may give interest bearing deposit in favour of GE for five year for the Sum above which shall be refunded back after satisfactory completion of five year from date of completion. (vii) Close vigin& promptness on the progress and joint measurement has to be ensured and Photographic evidence in Soft copy for complete repair process for each structural members shall be taken by Contractor & handed over to GE. (viii) The Construal chemicall Fibers to be used shall to of following approved brands :- (a) Sika (b) Chembond (c) Hilti (d) BASF (e) Dr.Fixit (f) FOSROC (g) CICO (h) STP Limited.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
Taking down shutters of any description exceeding 1.00 square metre and not exceeding 2.00 square metre each complete, all as specified and directed by Engineer-in charge.
Taking down shutters of any description not exceeding 1.00 square metre each complete, all as specified and directed by Engineer-in charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical and make good and Provn of cement concrete (1: 3: 6) type C - 0 for fixing hold fast without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical and make good and Provn of cement concrete (1: 3: 6) type C - 0 for fixing hold fast without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Taking down and re - fixing door shutter of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each in same opening after easing and adjusting and also refixing builders hardware as required; complete all as specified and directed
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:3, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Description all as per Srl item No 40 above , but except bricks complete all as specified and as directed by Engr-in-Charge .
Brick work with old size sub class 'B' bricks, straight or curved on plan any radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate. as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exceeding 5 cm but not exceeding 10 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc, complete all as specified and directed by Engr-in- Charge.
16-18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Description all as per item No 47 but except granite stone cut into required size for Cills, riser, steps or skirting etc. complete all as specified and as directed by Engineer-in-Charge. Note : Granite retrived under Srl item No 46 above shall be reused.
Moulding/ rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engineer-in-Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters shall be as per IS:1003 ; supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
35mm thick flush shutters, solid core construction, with block board core and plywood face pannels, commercial type on both sides to match with & including 6mm thick teak wood edging all around the board, complete all as specified and directed by Engineer-in charge.
38mm thick flush shutters, solid core construction, with block board core and decorative laminates of approved colourand pattern on both faces complete all as specified and directed by Engineer-in charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including supply and fixing necessary fixing lugs, hinges, lock strike plate, hold fast etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including PCC (1: 3: 6) type C - o using 12.5mm filling in back recess profile portion complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including supply and fixing necessary fixing lugs, hinges, lock strike plate, hold fast etc. complete, of frame size 165 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including PCC (1: 3: 6) type C - o using 12.5mm filling in back recess profile portion complete all as specified and as directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or gorged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to Fe 290 Gde E-165, complete all as specified and as directed by Engr-in-Charge.
Powder coated (of approved color) aluminum sections as in frame & shutter of windows, ventilators as in sliding / openable / louvers / fixed type with and including necessary rolling for smooth moving & locking arrangement, etc. fixed to wall including, preparation of disturbed portion both sides (internal & external surfaces of wall) match with existing surface treatment and all sides of aluminum frame shall be sealed with silicon sealent (inner / outer face) complete all as specified as directed by Engr - In - Charge Make of Aluminium sections : Jindal/Hindalco/makes specified in PS.
5mm frosted / tinted sheet glass, ordinary quality and glazing with rubber neoprene packing for aluminum doors / windows / ventilator in square / rectangular not exc 0.5 sq. m in each pane, complete all as specified and as directed.
Powder coated aluminum handle with locking arrangement 100mm, complete all as specified and directed. (ISI Mark)
Powder coated aluminum hinges special type suitable for aluminium openable windows 125mm long match, complete all as specified and directed. (ISI Mark)
Powder coated aluminum handle, 100mm, complete all as specified and directed. (ISI Mark)
Powder coated aluminium anodised, barrel tower bolts 150 mm of extruded section complete all as specified and directed. (ISI Mark)
5 mm thick frosted/ tinted glass ordinary quality and glazing with rubber neoprene packing for aluminium door/ windows in squares exceeding 0.50 Sqm in each pane complete all as specified.
Non skid, light coloured, white printed ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (light shade) of 10mm thick coloured, double charged (area of each tile exceeding 0.38 sqm not exceeding 0.64 sqm & size of tile 800mm x 800mm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Description all as per serial item No. 62 here-in-before but on vertical surfaces as in skirting/dado over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in levelling course for laying of floor tiles fair finished, complete all as specified.
PCC 1:3:6, (nominal mix), type C-1, using 20mm graded crushed stone aggregate as in staging for water tank above roof, complete all as specified & directed.
Glazed ceramic tiles, coloured digital size of size 600mmx300mm in pattern as approved by GE , thickness not less than 7mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement, laid over and including 10mm thick plastering in cement mortar 1:3, complete all as specified.
50mm thick PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in plinth protection finished even & smooth with out using extra cement incl making joints 10mm wide and 30mm deep at spacing n more than 2.5m and at corners at mandatory and filled bitumen mastic (1:1) complete all as specified and directed.
18/19 mm thick PVC board one side decorated laminated wall nut color / glossy finish of approved color and pattern and other balancing side white in colour, cut to size as required and fixed in position for cabinets, etc., fixed in repairs, complete all as specified and as directed. Make- Rajshree or approved by GE.
Telescopic drawer side channel of std size and incl of roller for moving drawer, mild steel bright finish, or electrogalvanised, for modular kitchen, fixed in repairs, complete all as specified for modular kitchen.
Stainless steel multipurpose basket in wooden / PVC drawers , drawers/partitions for storing rations of various types made of 4mm dia stainless steel rods, fixed in side partitions etc, fixed in repairs for modular kitchen, complete all as specified
Stainless steel of 3 to 4 mm dia luddle-craddle hanging stand for cutlery for modular kitchens, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Stainless steel zero crank hinges (auto) fancy type (with Euro concealed hinges) fixed to shutters in cupboards of standard size and shape for modular kitchens, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Aluminum powder coated fancy type handle, cast type, anodized, 100mm long, complete all as specified.
300mm size Stainless handle fancy type as per samplekept n GE's office, complete all as specified and as directed by Engineer-in-Charge.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed by Engr in Charge.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples, fixed in repairs, complete, all as specified and directed by Engr in Charge.
200 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
125 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate in repair complete all as specified.
Floor door stopper of aluminium power coated alloy long body (as per sample kept in GE's office) and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed. (ISI Mark)
Factory Made PVC Moulded Door Shutter of wall nut colour, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, fix in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam wall nut colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
100mm long, stainless steel butt hinges for PVC door, complete all as specified and directed by Engr-in- Charge.
Continuous (piano) hinges width of flaps (when open) 30 mm, mild steel, bright finish or electrogalvanised, complete all as specified and directed.
125mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
100 mm aluminium handles, cast type anodised in repair complete all as specified and directed. (ISI Mark)
Double action spring hinges 125 mm, mild steel with steel wire spring, stove enamelled black, fixed in repairs complete all as specified and directed.
Stainless steel 25mm dia (curtain rod) with fancy type dome as approved by GE, fixing stainless steel brackets, stops,roller etc., fixed in repairs, complete all as specified and as directed.
15 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing of 15mm bore and connections with new fittings in new or old position (Walls, ceiling, floors etc.), complete all as specified .
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing of 20mm bore and connections with new fittings in new or old position (Walls, ceiling, floors etc.), complete all as specified .
25 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing of 25mm bore and connections with new fittings in new or old position (Walls, ceiling, floors etc.), complete all as specified .
Cutting of existing steel tubing 25 mm to 32 mm for alteration or addition,complete all as specified and as directed. (Each cut to be measured seperately)
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 20 cm girth, complete all as specified and as directed by Engr-in-Charge.
Vitreous china wash down water closet suitable for 'P' or 'S' trap (pedestal pattern) white complete, including connection to drain pipe and to flushing pipe antisyphonage pipe etc, fixed in repair, complete all as specified and as directed. Make-CERA cat part No. S1050101/02, Jaquar -CNS-WHT-WH 10 or equivalent of any approved make as approved by GE
Plastic water closet seat, closet pattern with flat bottom and cover and incl mild steel chromium plated or aluminum hinges device complete, fixed in repairs , all as specified. Make-CERA cat part No. B1510121, Jaquar -CNS-WHT-WCS 1 or equivalent of approved make as approved by GE
Water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified. Make :- CERA Cat Part No-2071/ Jaquar-CNS-WHT-OP01 or equivalent of approved make approved by GE.
10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, PVC 32mm dia flushing pipe etc complete all as specified and as directed by Engr-in-Charge. Make: Cat Part No. B1020101 of make Cera, Jaquar or equivalent in performance of makes as specified in PS.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelain stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes, fixed in repairs complete, all as specified and as directed by Engr-in-Charge. Make-CERA cat part No. S 2040105 for WHB & for pedestal cat part No.S2090101, Jaquar- SLS-WHT -0611 F for WHB and SLS-WHT-1510 for pedestal or equivalent of approved make as approved by GE.
Brass chromium plated towel ring round 200mm dia, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make Jaquar Cat Part No AQN-7721/ Cera Cat part No 5002105 or equivalent of makes specified in PS.
20mm dia brass chromium plated tubular towel rails, D type,60 cm long between flanges, fixed in repair, complete all as specified and as directed. Make -Jaquar cat part No. CAN-1111NM / Cera cat part No F5007103 or equivalent of makes specified in PS.
Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge. Make -Jaquar cat part No. AKP-35771P / Cera cat part No F 5001114 or equivalent of makes specified in PS.
Corner Glass self ( With CP brakets) 225 x 225 mm complete all as specified and as directed. Make-Jaquar cat part No. CAN-1173/ Cera- F 5005102 or equivalent of makes specified in PS.
Single lever wall mixer 3 in 1, with provn of over head shower & hand shower, telephonic type, brass, chromium plated, fancy type, with capstan head handles with lettered 'hot' and 'cold', screwed down high pressure, including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, with provision for both hand shower and over head shower, fixed in repair, complete all as specified and directed. Make : Jaquarcat part No. FUS-29281/ Cera- F 2007403 or equivalent of makes specified in PS.
Centre hole mixer for mixing hot & cold water for wash hand basin, cast copper alloy, with dual capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' & 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe suitable for 15mm bore, fixed in repair complete all as specified and directed. Make : Jaquar, Cat part No. SOL-6169B/Cera- QTF 2006461 or equivalent of makes specified in PS.
Hand shower 90mm round shape (telephonic shower), chromium plated, with 1500mm long 15mm bore chrome finish flexible pipe with hook, fixed in repair complete all as specified and directed. Make: Jaquar-code HSH-1727,SHA-571/ Cera-F 7030105 for hand shower & F 8070401 for flexible tube.
Shower rose, brass, chromium plated, with CP arm 120mm dia with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union as in repair complete all as specified and directed. Make : Jaquar cat part No. OHS-1719, Cera- F 7040101 for arm & F 7020305 for shower rose.
Angle valve, brass, chromium plated, fancy type, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. Make : Jaquar cat part No- CON-053KN, Cera- QTF 2006201
Bib taps, brass, chromium plated, fancy type, long nose, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repairs complete all as specified and directed. Make : Jaquar cat part No.- CON-037KN, Cera-QTF 2006152.
Health faucet, brass, chromium plated, with 1000mm long 8mm dia chrome finish flexible pipe with wall hook, fixed in repair complete all as specified and directed. Make - Jaquar cat part No- ALD-573, Cera- F 8030103 or equivalent as approved by GE
Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection; for EWC fixed complete all as specified and as directed. Make : Jaquar, Cera or equivalent as approved by GE
PVC flexible connections 450mm long 15mm dia with brass flange nuts & washers complete all as specified & directed.Make-Jaquar, cat part No. ALD-805B, Cera-CG 107.
PVC flexible connections 600mm long 15mm dia with brass flange nuts & washers complete all as specified & directed.Make-Jaquar, cat part No. ALD-801B.
Stop valves, brass, fancy type with flange, chromium plated with long shank and cup (concealed type), screwed down high pressure, with capstan head handle, screwed both ends for iron pipe or for unions and fixed. Make : Jaquar cat part No.CQT-23083, Cera- F 1014751 for exposed part & F 4060102 for consealed part or as approved by GE.
Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, fixed in repair complete all as specified and directed. Make : Jaquar, Cera- cat No. F 5007106 or equivalent as approved by GE
CP brass grating 100mm dia, centre hole, fixed in repair complete all as specified and as directed. Make- Prayag Cat No. FT-70
CP brass grating 100mm dia, fixed in repair complete all as specified and as directed. Make- Prayag Cat No. FT-03
Toilet paper holder, brass, chromium plated, heavy duty, fixed with brass screw complete all as specified and as directed.Make- Jaquar cat part No. ACN-1153N, Cera-F 5007109.
Tumbler holder, brass, chromium plated, heavy duty, having suitable recesses made for hanging necessary bath items complete fixed with brass screws as per manufacturer's instructions. Make: Jaquar Cat part No. AQN-7741, Cera- F 5002107 as approved by GE.
Sink wall mixer, brass, chromium plated, fancy type, with capstan head handles screwed down high pressure, with lettered 'hot' and 'cold', including CP brass wall flanges and necessary extension nipples screwed for 15mm bore pipe connection, fixed in repair, complete all as specified and directed. Make : Jaquar Cat part No. CON-309KN, Cera- F 2007501.
Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including waste coupling and waste pipe & bedding in CM to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 1040mmx 510mmx 203mm bowl size 510mmx405mmx203mm, fixed in repair, complete all as specified and as directed. Make: Prayag, Cat No. 1244D of prayag or equivalent
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity (Tripple layer) white in colour including water tank cover (internaly/interlocking arrangment for water tank cover), hoisted and fixed in position including tank nipple inlet & outlet and connecting up pipes and dismantling of existing water tank, complete all as specified and directed.(fixed in repair)
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity (Tripple layer) white in colour including water tank cover (internaly/interlocking arrangment for water tank cover), hoisted and fixed in position including tank nipple inlet & outlet and connecting up pipes and dismantling of existing water tank complete all as specified and directed.(fixed in repair)
PTMT ball valve 20mm dia high pressure with polythene float and fly nut complete all as specified and directed. Make Prayag cat part No -152.
Gun-metal, globe or gate valves,20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed. Make: Cat Pt No 1001 of make Zoloto valves or equivalent in approved makes.
1.60mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed.
Rolled mild steel section of angle, tee, flats,and plates as in roof trusses, purlines, rails, etc and the like fixed with angle cleats and connecting plates including welding,conforming to E-250 (Fe-410, quality 'A') complete all as specified and directed .
Nails of 50mm to 80mm in length fixed with welding to MS sheet, complete all as specified and as directed by Engr-in-charge.
Taking down eaves gutter and rain water pipes (any size and pattern), including all fittings, heads, shoes, bends swan necks, etc. including cleaning or refixing or removal of stores ( measured overall as fixed along the centre line over fitting and accessories)
110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including PVC stack clamp, complete all as specified and as directed.
Description all as per description of srl item No 134 above but except pipes, complete all as specified and as directed.
110mm bore PVC (SWR) bends any radius in repairs, complete all as specified and as directed.
Stack clamps made out of 50mm x 5mm mild steel flat iron & 15 mm dia round iron steys, including bolts and nuts and securing ends of syays to wall or roof for 110mm bore, complete all as specified and as directed.
150 mm x 150mm size Salt-glazed stoneware gully traps, square or round mouthed, type ‘P’ and jointed, ISI marked complete all as specified.
Cast iron multi floor trap with grating to 75mm bore including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 in repairs, complete all as specified
Cast iron soil, sand cast waste and vent pipes,75mm dia in any length with or without ears with cement joints, laid in trenches or in floors in repair.
Sand Cast iron soil, waste and vent pipes,100mm dia in any length with or without ears with cement joints, fixed to wall in repair.
Re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes, 100mm dia in any length with or without ears with cement joints, fixed to wall in repair.
Sand Cast iron soil, waste and vent pipes,75mm dia in any length with or without ears with cement joints, fixed to wall in repair.
Re-fixing only pipe execpet pipe Sand Cast iron soil, waste and vent pipes,75mm dia in any length with or without ears with cement joints, fixed to wall in repair.
Cast iron bends 75mm size with access door (any radius) measured larger bore in repairs, complete all as specified .
Fixing only in repairs 75mm bore cast iron bends (any radius) measured larger bore all as specified .
Cast iron bends/reducer 100mm bore with access door (any radius) diminishing pieces or tapers (larger bore measured) all as specified .
Fixing only in repairs 100mm bore cast iron bends (any radius) measured larger bore all as specified .
Branch pieces 75mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door in repairs, complete all as specified and as directed.
Branch pieces 100mm bore Cast iron, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval accessed door in repairs, complete all as specified and as directed.
Cast iron cowls of 75mm bore as in repair, complete all as specified and as directed.
Cast iron cowls of 100mm bore as in repair, complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes, any size up to 100mm bore, jointed in in cement mortor and taking out of trenches if required, complete all as specified and as directed.
Salt glazed stone ware drain pipes of 150mm dia (internal bore) grade ‘A’ laid in trenches and jointed complete all as specified and directed.
Description all as per srl item No 154 but 200mm dia complete all as specified and directed.
Cutting into existing manholes for connecting new drains of 150mm dia internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate smooth finished and reforming benching as required complete all as specified and directed.
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in concrete bed to drain pipes 150mm internal bore including packing under and hunching against the sides of pipes after they are laid and tested, in complete all as specified and directed.
Description all as per srl item No.157 above but for 200mm bore complete all as specified and directed.
Dismantling of cast iron or SGSW drains pipes jointed in cement mortar of dia 150mm and taking out of trenches/walls if required (of any bore bore) complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron or SGSW drains pipes jointed in cement mortar of dia 200mm and taking out of trenches/walls if required (of any bore bore) complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for fdn for shafts, cills, cesspits, manhole pier holes n.exc 10Sqm on plan and getting out complete in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed.
Removing of excavated soil to a distance n.exc 50m and depositing where directed by the Engr-in-Charge at a level n.exc 1.50m above the starting point complete all as directed
Complete removing existing treatment using grinding machine/ Mechanical means (as per instructions)on walls including scraping,removing all mud,cake with wire brush and gunny bags from old plastered surfaces and preparation of surfaces by applying minimum 1 to 1.2mm thickness of Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and directed.
Rubbing, stopping existing treatment on ceiling including scraping,removing all mud,cake with wire brush and gunny bags from old plastered surfaces and preparation of surfaces by applying 1 to 1.2mm thickness of Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and directed.
Preparation of new plastered surfaces of wall by applying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and directed.
Preparation of new plastered surfaces of ceiling by applying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth/even finish using sand paper and applying two coats of distemper oil emulsion over a coat of alkali resistant cement based priming paint complete all as specified and directed.
Prepration of old wall surfaces of walls by washing,rubbing down including brooming down or steel wire brushing and applying two coats of Cement base paint all as specified and directed.
Providing and applying first single coat of approved primer and two coats of anti-algal, anti-fungal, exterior paint as specified below of an approved make and colour as per manufacturers specifications to any surface, upto 12-15m height from ground level and at all locations as directed including preparing surfaces for painting by any approved means, scaffolding, cleaning and curing etc. complete as directed by Engineer-in-charge. By using acrylic based exterior paint.
Preparation of old decorated plastered surfaces and applying two coats of white wash on ceiling, complete all as specified and directed.
Preparation of old decorated plastered surfaces and applying one coat of white wash on walls, complete all as specified and directed.
Preparation of old wooden painted surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of new wood and wood based surfaces of any description exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of old steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as spd and directed.
Preparation of new or previously untreated steel and iron surface of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floor and paving exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
75mm thick PCC 1:4:8 type D1 (using 20mm graded stone aggregate) as in Sub base complete all as specified and directed.
50mm thick sand filling in floors or pavings, laid in layers, spread, levelled, and blinded with earth and rammed including watering, complete all as specified and as directed.
Machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand complete all as specified and directed.
S&F in repair 18 mm thick prelaminated medium density fibre (MDF) boards, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws as in shelves , cup board shutters etc, complete all as specified and directed.
Extra over rates of MDF board 18/19mm wide for external teak wood lipping, 6mm thick fixed with nails.
S&F plain fillets square of rectangular or triangular in section of Iind class Hard wood sectional area exc 6 Sqcm but nexc 13 Sqcm fixed with nails as fixed in repair.
S&F magnet catchers 50mm steel plate MS body and striking plate incl letting in & fixed.
M&L for providing & fixing precast cement concrete Pavor / kerb blocks in (1:2:4) type B-1 n.exc 10cm thick set in CM (1:4).
Stainless steel pipe 50mm size square / round 16 gauge and grade 304 fixed to wall or in floors including necessary cutting holes and fixed with suitable epoxy resin in vertical / horizontal position cut to length required and welded all as directed and as specified.
Stainless steel pipe 35mm size square / round 16 gauge and grade 304 fixed to wall or in floors including necessary cutting holes and fixed with suitable Epoxy resin in vertical / horizontal position cut to length required and welded all as directed and as specified.
Stainless steel pipe/square 16 mm dia 16 gauge and grade 304 fixed in vertical/Horizontal position cut to length required and welded all as directed and as specified.
Stainless steel grade 304 foot caps and top caps of 50 mm dia and 16 gauge thickness for baluster fixed to vertical pipes including necessary welding etc complete .
Stainless steel grade 304 foot caps and top caps of 35 mm dia and 16 gauge thickness for baluster fixed to vertical pipes including necessary welding etc complete .
Stainless steel grade 304 foot caps and top caps of 16 mm dia and 16 gauge thickness for baluster fixed to vertical pipes including necessary welding etc complete .
Site clearance in soft/ loose soil and dressed with proper manner upto desire satisfaction of Engr-in-Charge, Complete all as specified and as directed.
Cutting holes in brick walls/ RCC beams by using mechanical means for placing spout and making good after provision of pipe, complete all as specified and as directed.
GI pipe 40mm bore, medium grade as in spout for sunken portion, complete all as specified and as directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick including all accessories for one light / fan / bell/ exhaust fan controlled by one switch with MS boxes of suitable size for modular switch/socktes combination, including modular cover plate of suitable size,including blank plate (if required) for concealed on walls,switches, socket outlet, regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 195 above but one light contorlled by two 2-way switches.
All as per description of Serial item No 195 here-in-before but one 6 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 195 here-in-before but one 3/5 pin 5 Amp socket outlet on independent board , complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 195 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Modular metal flush box suitable for 6 module, complete all as specified and as directed by Engr-in-Charge.
Modular metal flush box suitable for 4 module, complete all as specified and as directed by Engr-in-Charge.
Modular metal flush box suitable for 3 module, complete all as specified and as directed by Engr-in-Charge.
Modular metal flush box suitable for 2 module, complete all as specified and as directed by Engr-in-Charge.
Modular metal flush box suitable for 1 module, complete all as specified and as directed by Engr-in-Charge.
Modular white cover plate with frame suitable for 6 module, complete all as specified and as directed by Engr-in-Charge.
Modular white cover plate with frame suitable for 4 module, complete all as specified and as directed by Engr-in-Charge.
Modular white cover plate with frame suitable for 3 module, complete all as specified and as directed by Engr-in-Charge.
Modular white cover plate with frame suitable for 2 module, complete all as specified and as directed by Engr-in-Charge.
Modular white cover plate with frame suitable for 1 module, complete all as specified and as directed by Engr-in-Charge.
Modular switch single pole one way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Modular switch single pole two way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Modular socket outlet, 2 in 1, 3 pin, 6 Amp flush type 2 module type, complete all as specified and as directed by Engr-in-Charge.
Modular socket outlet, 2 in 1, 6 pin, 16 Amp flush type 1 module type, complete all as specified and as directed by Engr-in-Charge.
Modular socket outlet, 2 in 1, 2/3 pin, 6/16 Amp flush type 2 module type, complete all as specified and as directed by Engr-in-Charge.
Slim linear LED lighting fixture 20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Make : Havells cat Pt No LHEXBYPNIN1W020 / Wipro Cat Pt No D532065 /SYSKA Cat Pt No- SSK-SQ-2001
Slim linear LED lighting fixture 10/12 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Make- Havells as per ordering code LHEXBTP7IN1W009 / Wipro Cat Pt No D531065 /Syska cat No SSK-T5-12W.
Slim linear LED lighting fixture 5/6 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Make- Havells as per ordering code LHEXBLP7IN1W005 / Wipro Cat Pt No D530565 /Syska cat No SSK-T5-6W.
LED bulk head luminaire, 10 watt and connecting up with flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells cat Pt No HEXAFT10WLED857SSYMBOPC, 230V or equivalent in performance of makes as specified in particular specifications.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropriate size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifications ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCB TPN, 4-pole ,40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "B" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
RCCB TPN, 4-pole ,40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "B" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of RCCB shall be as directed by Engr-in-Charge.
Modular bell switch single pole one way 6 Amps 1 module type complete all as specified and directed by Engr- in-charge
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA "C" Curve including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Taking down the existing geyser of any capacity carefully and shifting to the store abd re fixing the same after completion of civil work as directed by the Engr-in-Charge.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 16 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling/exhaust fan and cable etc. and refixing/hanging the same after repair/replacement of damaged/worn out parts like canopy 02 Nos, down rod, clamps with nuts, bolts and washers, rubber bush, greasing, oiling and provn of cable from ceiling rose to fan, etc. including painting with two coats of synthetic enamel white paint and writting Ser No/Mes No with black paint complete, all as specified.
Supply, installation, testing and commissioning of indoor type, weather proof, cubicle panel board made out of 2 mm thick CRCA steel sheet floor mounted, frame made out of 40 x 40 x 6 mm equal MS angle,front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 voilts 50 Hz, factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, The panel shall accomodate the following equiptments :- (a) Copper bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 Amps for Phases and neutral- 04 set (b) Fixing only electric three phase meter-08 Nos (c) MCCB 4 pole , lcs = 100 % icu -25 KA , 415 Volts , 200 Amps , with adjustable micro processor release with extended terminals -01 No. (d) MCB TPN 40 to 63 Amps 415 vlots -08 Nos (e) RYB indicators lamps - 01 set
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 50 sqmm 3.5 core, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. Note :- Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable complete all as specified and as directed by Engr-in-Charge.
40 mm bore GI tubing, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or fixed to pole, complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (g) Testing of earthing.
KALSOTRA CONSTRUCTION CO
SHIV CHARAN GUPTA AND SONS
JINDAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .