| 1 | L1₹24.9 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹24.9 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹26.3 L+₹1.5 L (5.96%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹26.3 L+₹1.5 L (5.96%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹26.4 L+₹1.5 L (6.14%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | ₹26.4 L+₹1.5 L (6.14%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹26.6 L+₹1.7 L (7.04%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹26.6 L+₹1.7 L (7.04%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹27.2 L+₹2.3 L (9.34%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | ₹27.2 L+₹2.3 L (9.34%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Aug 2023, 6:00 pmClosed
GE (AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR / MAINTENANCE OF EXTERNAL ELECTRIFICATION SYSTEM AND ALLIED WORKS AT AF STN UNDER GE (AF) CHABUA
2023_MES_612280_1
495/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUG
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(AF) CHABUA
₹50,000
Yes
9 Sept 2023
5 Aug 2023
2 Sept 2023
5 Aug 2023
26 Aug 2023
19 Aug 2023
5 Aug 2023 - 12 Aug 2023
Amount
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) including taking down old unserviceable pole complete all as specified and directed. Note:- Earthwork and PCC shall be measured and paid separately under respective items.
Supply and fixing in repairs mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 2009 complete all as specified and directed.
M&L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminum paint over a coat of red oxide primer, complete all as specified and as directed.
Supply and stringing in repair ACSR conductor of any size for LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and as directed.
All as per item No. 4 here-in-before but GI wire 4 mm dia complete all as specified and as directed.
Cleaning around any E/M installations/ pole structures including removing all grass, creepers and other vegetations with roots on soil, hard standing and on chain link fencing complete all as directed and removing the rubbish to a distance not exceeding 50 mtr and depositing where directed.
Cutting and trimming of branches n.exc 50 mm dia in size obstructing lumination of street light and touching line of LT and HT line complete all as specified and as directed.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as specified and as directed.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as specified and as directed.
S&F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as specified and as directed.
M&L for dehydration & filtration of voltage stabilizer/isolation transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filtration to achieve 40 KV at 2.5 mm gap complete all as specified and directed. Note:- (i) The filtration of the voltage stabilizer/isolation transformer oil shall be carried out at different locations of the AF Stn Chabua. (ii) The report before filtration & after filtration to be submitted by contractor. (iii) Oil for topping up will be measured and paid separately. (iv) Centrifuging Machine with all T&P & testing equipment required for dehydration to be arranged by contractor.
Supply & toping up of new voltage stabilizer/isolation transformer oil (in sealed barrel) conforming to IS 335 std having dielectric strength 40 KV at 2.5 mm gap after initial dehydration complete all as specified.
Dismantling and taking out old worn out reversible synchronous motor ( servo motor) from the voltage stabilizer and supply and fix reversible servo motor single phase 230 Volts capacity and testing all as specified and directed.
Dismantling and taking out old worn out I C electronic control card from the voltage stabilizer up to 250 KVA and supply and fix I C electronic control card and testing all as specified and directed.
Dismantling and taking out defected PCB from the voltage stabilizer and reinstalling the I C electronic control card after repair complete and testing all as specified and directed.
S&F in repairs control wiring of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs 12 pin connector of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs RC network of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs main big gear of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs small gear of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs high low voltage cut off circuit of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
S&F in repairs bush of voltage stabilizer, 3 phase upto 300kVA complete all as specified and directed.
Rectifying the any leakage in neutral/EN voltage by checking overhead line, jumpers, under ground cable, MCB, MCCB with required manpower to reducing the leakage in permissible limit and balancing the three phase supply complete all as directed.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire complete all as specified and directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs including taking down of old unserviceable cable complete of size 240 Sqmm nominal cross section 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 185 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 150 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 120 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 95 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 70 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 50 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 35 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 25 Sqmm X 3.5 core complete all as specified and as directed.
All as per ser item No 25 above but Size of cable 16 Sqmm X 4.0 core complete all as specified and as directed.
Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and directed.
Excavation in trenches in soft/loose soil, n.exc 1.5 m wide and exc 1.50m but n.exc 3.0 m in depth for foundation or shafts, wells cesspit, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers nexc 25cm complete all as specified and directed.
Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) up to 180mm thickness complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
Materials and labour for brick work with Sub Class 'B' bricks well burnt laid breadth wise along the length or cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 50mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete all as specified and directed.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreting with PCC 1:3:6 to match with the adjacent surfaces complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings to poles & the like etc including weathering, slightly rounded or chamfered angles and throating as complete all as specified and directed.
M&L for rewinding 433 Volts LV coils of voltage stabilizer/isolation transformer of using proper size super enameled copper wire suitable for working voltage 1.1 KV/11 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed. Note:- (i). Oil filtration, supply of new oil will be measured separately. (ii). All petty parts including nut, bolts, gasket minor welding are deemed to be included the rate quoted. (iii). The rate for taking out, refixing after repair, both side transportation, lifting /unloading of voltage stabilizer/ isolation transformer by crane/manual should be deemed to include in the rate quoted.
S&F in replacement Pin Type Porcelain, Vitreous, Brown Insulator including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and one Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade complete all as specified and directed.
S&F in replacement shackle type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 50x65mm, clearance of hole 9mm complete all as specified and as directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unserviceable earthing complete all as specified and as directed. NOTES:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for earthing complete with copper earth plate electrode 60 x 60 cm x 3.15 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including copper earth strip of size 20 x 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unserviceable one complete all as specified and as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for dismantling the cable connections of four pole/three pole Air circuit breaker of capacity 630 to 1250 Amps, 415 V 50 HZ of any make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance:- (a) Cleaning the insulation parts including bushings with CTC solution. (b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. (c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. (d) Check arching for damage . (e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . (f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. (g) Checking control device free for operation. (h) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note:- (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/pins etc. (ii) Major spares like Shunt release & trip coil etc will be measured & paid separately under relevant schedule items shall be OEM makes.
Supply only fixed arching contacts suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply only moving arching contacts suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply only draw out breaker suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply only under-voltage release 240 V AC suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply only shunt release (240 V AC) suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply and fix motor 240 V AC suitable for air circuit breakers of 630 Amps to 1250 Amps complete all as specified and directed.
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension GI wire, one twin core cable flat or circular with size 16 sqmm x 2 core complete all as specified and directed.
M&L for painting of LT tubular poles up to 9 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos complete all as specified and directed.
M&L for recharging of earthing by filling of magnesium sulphate, 100% water soluble fertilizer type in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pits after mixing in water in appropriate quantity.
M&L for recharging of earthing by filling of common salt in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pits after mixing in water in appropriate quantity.
M&L in repair LT cable Heat shrinkable straight through jointing kit with jointing material and accessories suitable for 1100 volts grade LT XLPE armoured aluminium conductor of size 25 sqmm to 50 sqmm complete all as specified and directed.
All as per ser item No 65 here in before above but suitable for 70 sqmm to 120 sqmm complete all as specified and directed.
All as per ser item No 65 here in before above but suitable for 150 sqmm to 185 sqmm complete all as specified and directed.
All as per ser item No 65 here in before above but suitable for 240 sqmm to 300 sqmm complete all as specified and directed.
Disconnecting electrically switch boards/electric panels/distribution boards of any size by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/overheated cable ends/ thimbles etc and M&L for fixing of new aluminium lugs/copper lugs of any size up to 630 sqmm as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing system. Note:- (i) Any addition/alteration required for fixing parts included in the quoted rate in the items. (ii) All consumable items such as thimbles, lugs, control wire up to 10 mtr is deemed to be included in the quoted rate.
Schedule of Credit
STANDARD ELECTRIC WINDERS
M/s Sashi Enterprise
MAA COMMUNICATION
M/S S. P. ENTERPRISE
FREEZCON
M/s HALDER ENTERPRISE
NChetia and Sons Trading
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .